Development of coherent Raman measurements of temperature in condensed phases

We report theoretical considerations and preliminary data on various forms of coherent Raman spectroscopy that have been considered as candidates for measurement of temperature in condensed phase experiments with picosecond time resolution. Due to the inherent broadness and congestion of vibrational features in condensed phase solids, particularly at high temperatures and pressures, only approaches that rely on the ratio of anti-Stokes to Stokes spectral features are considered. Methods that rely on resolution of vibrational progressions, calibration of frequency shifts with temperature and pressure in reference experiments, or detailed comparison to calculation are inappropriate or impossible for our applications. In particular, we consider femtosecond stimulated Raman spectroscopy (FSRS), femtosecond/picosecond hybrid coherent Raman spectroscopy (multiplex CARS), and optical heterodyne detected femtosecond Raman induced Kerr Effect spectroscopy (OHD-FRIKES). We show that only FSRS has the ability to measure temperature via an anti-Stokes to Stokes ratio of peaks.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The effect of an isotopic non-equilibrium plasma on electron temperature measurements

Electron temperatures determined by electrostatic probe, diffuse resonance, and radar backscatter techniques in an isotropic two temperature plasma are presented. Plasma models corresponding to the addition of a minor component of energetic electrons, and models corresponding to a process that cools a fraction of the ionospheric electrons are considered. The diffuse resonance temperature is found to lie between the probe and radar backscatter temperatures. The isotropic models corresponding to the addition of energetic electrons cannot support the reported discrepancies between radio wave and probe electron temperature measurements. Temperature differences similar to the observed differences can be produced by models with a fraction of the electrons at a temperature cooler than that of the main component of electrons.

Benson, R. F.↗

Temperature Measurement During Polymerization of Bone Cement in Percutaneous Vertebroplasty: An In Vivo Study in Humans

Aim of the study was to 'in vivo' measure temperature, during percutaneous vertebroplasty (PV), within a vertebral body injected with different bone cements. According to the declaration of Helsinki, 22 women (60-80 years; mean, 75 years) with painful osteoporotic vertebral collapse underwent bilateral transpedicular PV on 22 lumbar vertebrae. Two 10-G vertebroplasty needles were introduced into the vertebra under digital fluoroscopy; a 16-G radiofrequency thermoablation needle (Starburst XL; RITA Medical System Inc., USA), carrying five thermocouples, was than coaxially inserted. Eleven different bone cements were injected and temperatures were measured every 30 s until temperatures dropped under 45{sup o}C. After the thermocouple needle was withdrawn, bilateral PV was completed with cement injection through the vertebroplasty needle. Unpaired Student's t-tests, Kruskal-Wallis test, and Wilcoxon signed rank test were used to evaluate significant differences (p < 0.05) in peak temperatures, variations between cements, and clinical outcome. All procedures were completed without complications, achieving good clinical outcomes (p < 0.0001). Regarding average peak temperature, cements were divided into three groups: A (over 60{sup o}C), B (from 50{sup o} to 60{sup o}C), and C (below 50{sup o}C). Peak temperature in Group A (86.7 {+-} 10.7{sup o}C) was significantly higher (p = 0.0172) than that in Groups B (60.5 {+-} 3.7{sup o}C) and C (44.8 {+-} 2.6{sup o}C). The average of all thermocouples showed an extremely significant difference (p = 0.0002) between groups. None of the tested cements maintained a temperature {>=}45{sup o}C for more than 30 min. These data suggest that back-pain improvement is obtained not by thermal necrosis but by mechanical consolidation only. The relative necrotic thermal effect in vertebral metastases seems to confirm that analgesia must be considered the main intent of PV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A potential nuclear magnetic resonance imaging approach for noncontact temperature measurement

It is proposed that in a nuclear magnetic resonance (NMR) imaging experiment that it should be possible to measure temperature through an extended volume. The basis for such a measurement would depend upon sensing a temperature dependent on NMR parameter in an inert, volatile molecule (or fluid) filling the volume of interest. Exploratory work suggest that one suitable candidate for such a purpose might be CH3Cl. Possible parameters, other inert gases and feasible measurement schemes that might provide such temperature measurement are discussed.

Manatt, Stanley L.↗

A Simple and Portable Multi-Channel Pyrometer allowing temperature measurements down to 800 K on the microsecond scale

The measurement of transient temperatures less than 1000 K for samples in laser-heated diamond anvil cells remains a challenge. Here we present a design and performance characteristics for a multi-channel pyrometer that works in the NIR from 1200 to 2000 nm. It has a relatively small footprint, is portable, only requires low voltage power supplies and can report temperatures down to 800 K on the millisecond scale or faster. A single data point without averaging can be acquired in 14 microseconds (sampling rate of 70'000 times/s). In conjunction with a diamond anvil cell, the system still works down to about 830 K. The pyrometer has been interfaced several times with the laser heating system at the High Pressure Collaborative Access Team (HPCAT) at the Advanced Photon Source in Chicago with good results.

Montgomery, Jeffrey M.↗

Comparison of Simultaneous Shock Temperature Measurements from Three Different Pyrometry Systems

Pyrometry is one of the most prevalent techniques for measuring temperature in shock physics experiments. However, the challenges of applying pyrometry in such highly dynamic environments produces multiple sources of uncertainty that require investigation. An outstanding question is the degree of agreement between different pyrometers and different experiments. Here we report a series of novel plate impact experiments with simultaneous thermal radiance measurements using three different multi-wavelength optical pyrometry systems, each with different spatial and temporal resolutions, on samples shocked to identical states. We compare the temperatures measured by each system and their associated uncertainties using a number of emissivity assumptions. The results shown that the measurements from all three systems agree within uncertainty. Furthermore, some non-thermal light contamination was observed despite a number of prevention measures.

36 MATERIALS SCIENCE↗

Use of IR pyrometry to measure free-surface temperatures of partially melted tin as a function of shock pressure

Equilibrium equation of state theory predicts that the free-surface release temperature of shock-loaded tin will show a plateau at 505 K in the stress range from 19.5 to 33.0 GPa, corresponding to the solid-liquid, mixed-phase region of tin. In this paper we report free-surface temperature measurements on shock-loaded tin from 15 to 31 GPa using multiwavelength optical pyrometry. The shock waves were generated by direct contact of detonating high explosive with a tin sample, and the stress in the sample was determined by free-surface velocity measurements using photon Doppler velocimetry. We measured the emitted thermal radiance in the near IR region at four wavelengths from 1.5 to 5.0 mum. Above 25 GPa the measured free-surface temperatures were higher than the predicted 505 K, and they increased with increasing stress. This deviation may be explained by hot spots and/or variations in surface emissivity, and it may indicate a weakness in the use of a simple analysis of multiwavelength pyrometry data for conditions, such as above the melt threshold, where hot spots or emissivity variations may be significant. We are continuing to study the discrepancy to determine its cause.

36 MATERIALS SCIENCE↗

Investigations on atomic-vapor-filter high-spectral-resolution lidar for temperature measurements

The temperature measurement by the analysis of Rayleigh scattered laser radiation with atomic vapor filters is investigated in both theory and laboratory experiments. Synthetic air is irradiated with a cw dye laser at 283 nano-meters, and the backscattered spectrum is analyzed with two lead vapor cells in one oven. Temperature measurements are carried out, and the effect of different parameters on the accuracy is investigated. Important aspects for the realization of a lidar are given.

Voss, E.↗

Noncontact Temperature Measurement

Noncontact temperature measurement has been identified as one of the eight advanced technology development (ATD) areas to support the effort of the Microgravity Science and Applications Division in developing six Space Station flight experiment facilities. This two-day workshop was an opportunity for all six disciplines to present their requirements on noncontact temperature measurement and to discuss state-of-the-art developments. Multi-color pyrometry, laser pyrometry and radiometric imaging techniques are addressed.

Lee, Mark C.↗

Surface Temperature Measurement Using Hematite Coating

Systems and methods that are capable of measuring temperature via spectrophotometry principles are discussed herein. These systems and methods are based on the temperature dependence of the reflection spectrum of hematite. Light reflected from these sensors can be measured to determine a temperature, based on changes in the reflection spectrum discussed herein.

Bencic, Timothy J.↗

In-situ two-dimensional temperature measurements using x-ray fluorescence spectroscopy in laminar flames with high silica particle concentrations

X-ray fluorescence spectroscopy (XRF) was used to measure temperatures and study mixing, for the first time in silica particle synthesis flames. Hexamethyldisiloxane (HMDSO) and trimethylsilanol (TMSO) were the particle precursors. A multi-element diffusion burner was used to produce a flat methane flame, and the precursors, dilute in inert gas, were injected via a central jet. Krypton was the fluorescent medium at 3.2 % concentration by volume. Scans with Kr in the central flow and not in the main flow were made to assess the mixing effects between the central and main gas flows. When HMDSO or TMSO were added, a secondary diffusion flame formed between the jet and the main methane flame. The results revealed a dramatic change in the centerline temperature profile of the jet gases when HMDSO or TMSO were added. The main methane flame stoichiometry also affected the temperature profiles. The results show HMDSO and TMSO reactions are initiated in a lowtemperature and low-oxygen concentration region of the jet where thermal decomposition is not expected to be significant. Reaction of the particle precursors is therefore attributed to radical transport from the main methane flame. In the current work, particle number densities of up to 270 g/m 3 locally are estimated. Thus, the study also demonstrates the capability of the XRF technique for high spatial fidelity measurements in flames with high concentrations of condensed-phase particles, leveraging the attribute that the XRF signal is generally not impacted by condensed-phase interferences. In conclusion, the observations and data obtained in this study inform likely reaction pathways for this important class of siloxane compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gas-Temperature Measurement With Minimal Perturbation

Method for measuring temperature of hot turbulent gases uses three heatflux calorimeters. One calorimeter measures radiative heat flux, while other two measure total heat flux (convective and radiative), at two different temperatures. Adapted for commercial uses in such operations as monitoring temperatures of flue gases, piped liquid or gaseous products, internal-combustion or jet engine exhausts.

Fu, T. S.↗

High Temperature / High Frequency Temperature Measurement: Achieving MHz Response at Temperatures > 1000 Deg-F

High frequency temperature measurements are not possible with current SOA temperature measurement devices at temperatures higher than ~700 deg-F. Temperature measurements above ~1000 deg-F are typical for entry vehicle thermal protection systems (TPS), rocket engines, ram/scramjet engines, etc. A new technology capable of achieving ~1200 deg-F temperature measurements with MHz response has been achieved. Investigations are underway to extend the concept to even higher temperatures. A U.S. patent application is about to be submitted.

High Frequency↗

Non-contact temperature measurements for biotechnology discipline working group

In the biotechnology research areas, there is interest in measuring temperature changes over very small dimensions, such as the surface of a 10-micrometer diameter biological cell immersed in cell culture fluid. Non-interference measurements of other properties, such as chemical constituents and their concentrations, are also needed. Contacting probes for pH have recently been developed to penetrate a cell but questions have been raised about their accuracy and net value.

Snyder, Robert S.↗