Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tensile testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Facile Tensile Testing Platform for In Situ Transmission Electron Microscopy of Nanomaterials

In situ tensile testing using transmission electron microscopy (TEM) is a powerful technique to probe structure-property relationships of materials at the atomic scale. In this work, a facile tensile testing platform for in situ characterization of materials inside a transmission electron microscope is demonstrated. The platform consists of: 1) a commercially available, flexible, electron-transparent substrate (e.g., TEM grid) integrated with a conventional tensile testing holder, and 2) a finite element simulation providing quantification of specimen-applied strain. The flexible substrate (carbon support film of the TEM grid) mitigates strain concentrations usually found in free-standing films and enables in situ straining experiments to be performed on materials that cannot undergo localized thinning or focused ion beam lift-out. The finite element simulation enables direct correlation of holder displacement with sample strain, providing upper and lower bounds of expected strain across the substrate. The tensile testing platform is validated for three disparate material systems: sputtered gold-palladium, few-layer transferred tungsten disulfide, and electrodeposited lithium, by measuring lattice strain from experimentally recorded electron diffraction data. The results show good agreement between experiment and simulation, providing confidence in the ability to transfer strain from holder to sample and relate TEM crystal structural observations with material mechanical properties.

2D materials↗

Understanding the limitations and potential of micro tensile testing of tungsten and needs for crystal plasticity modelling

Tungsten is the leading plasma facing material candidate due to its exceptional properties. Understanding the response to neutron irradiation is crucial for the lifetime evaluation of tungsten. The limited space in nuclear reactors and the high levels of radioactivity of the specimens after irradiation are significant barriers to accurately measuring the mechanical properties after neutron irradiation. Testing of micro tensile specimens is one approach to reduce the total amount of irradiated material needed for a set of mechanical testing experiments. However, micro samples are not necessarily measuring the bulk material properties, as size effects produce higher measured mechanical properties than is observed in engineering size counterparts. Determining the minimal sample size for reliable bulk property measurement, combined with modeling efforts, is essential. We conducted room temperature tensile tests on tungsten micro tensile specimens fabricated with focused ion beam, plasma focused ion beam and femto-second laser ablation system to dimension of 2×2×7?µm³, 7×7×18?µm³, and 80×100×233?µm³ (width×thickness×gauge-length), respectively. Elevated tensile testing was performed up to 475°C on 5×5×18?µm³ specimens fabricated with focused ion beam. The smallest specimens exhibited a high degree of ductility and strength, whereas the largest specimens demonstrated behavior akin to bulk tungsten. To investigate the effects introduced by the micro specimen fabrication processes and to obtain the necessary bulk dislocation density for the crystal plasticity model, we employed X-ray diffraction depth profiling. This measurement was performed using different X-ray sources with varying penetration depths. Finally, the potential and limitations of micro mechanical tests for tungsten will be discussed.

36 - MATERIALS SCIENCE↗

Investigating the failure behavior of cast Al-11Ce-0.4Mg alloys using in-situ scanning electron microscopy tensile testing

Within the last decade, research on Al-Ce-Mg alloys has reported promising results for use in cast part applications. In this paper, the failure behavior of cast Al-11Ce-0.4Mg (wt%) was investigated experimentally with focus on the effect the matrix and intermetallic phases have on the fracture propagation behavior at failure. For the first time, in-situ SEM tensile testing was used to study the failure behavior of cast Al-Ce alloys, reporting results for uniaxial, DIC, and single edge notch tensile tests. The results of the in-situ SEM tensile testing were compared with the materials characterization experiments, which included serial sectioning, EBSD, EDS, and fractography. Analysis of EBSD and EDS mapping of cast Al-11Ce-0.4Mg showed that the cast microstructure was a hypereutectic two phase Al-Ce alloy with grains encompassing large complex colonies of laminar eutectic Al 11 Ce 3 intermetallic. The uniaxial tensile results reported the effect casting defects have on the strength and ductility of the alloy, and DIC in-situ testing showed that the eutectic colonies plastically deform less than the matrix phase. In-situ SEM single edge notch tensile testing displayed how the strength of an individual phase affected the crack propagation direction in the alloy. The results of both the materials characterization and in-situ tensile testing experiments on the failure of this alloy revealed further directions for future alloy development that can improve both the strength and fracture toughness of Al-Ce-Mg alloys.

36 MATERIALS SCIENCE↗

Length scale effects of micro- and meso-scale tensile tests of unirradiated and irradiated Zircaloy-4 cladding

Zircaloy-4 is an essential material for cladding structures within fission-based reactors. To explore the changes in properties measured on differing length scales, FIB-machined micro-scale tensile tests were performed on both irradiated and control groups of Zircaloy-4. This was correlated with tensile testing on femtosecond laser-machined meso-scale specimens. Pronounced size effects were found when varying specimen geometry. Increases in tensile geometry size were associated with a reduction in measured yield stress for both irradiated and unirradiated samples. Here, meso-scale testing found strength and strain values similar to that of bulk-scale testing.

36 MATERIALS SCIENCE↗

Toward Standardized Microscale Tensile Testing for Two‐Photon Polymerization‐Fabricated Materials in Liquid

Two-photon polymerization (TPP) enables the fabrication of intricate 3D microstructures with submicron precision, offering significant potential in biomedical applications like tissue engineering. In such applications, to print materials and structures with defined mechanics, it is crucial to understand how TPP printing parameters impact the material properties in a physiologically relevant liquid environment. Herein, an experimental approach utilizing microscale tensile testing (μTT) for the systematic measurement of TPP-fabricated microfibers submerged in liquid as a function of printing parameters is introduced. Using a diurethane dimethacrylate-based resin, the influence of printing parameters on microfiber geometry is first explored, demonstrating cross-sectional areas ranging from 1 to 36 μm 2 . Tensile testing reveals Young's moduli between 0.5 and 1.5 GPa and yield strengths from 10 to 60 MPa. The experimental data show an excellent fit with the Ogden hyperelastic polymer model, which enables a detailed analysis of how variations in writing speed, laser power, and printing path influence the mechanical properties of TPP microfibers. The μTT method is also showcased for evaluating multiple commercial resins and for performing cyclic loading experiments. Collectively, this study builds a foundation toward a standardized microscale tensile testing framework to characterize the mechanical properties of TPP printed structures.

mechanical characterization↗

Micro-tensile testing of neutron-irradiated Al/Zr and Zr/U-Mo diffusion bonds

This study focuses on micro-tensile testing of neutron-irradiated Al/Zr and Zr/U-Mo diffusion bonds, which are integral to the structure and performance of nuclear fuel plates used in the fuel being developed for U.S. high-power research reactors. During fabrication, two distinct diffusion bonds occur—one at the Zr/U-10Mo interface via roll bonding, and the Zr/Al interface via hot isostatic pressing at 833 K. This work utilizes micro-tensile testing specimens approximately 7 × 7 × 18 μm 3 , which are sufficiently large to encompass the identified diffusion zones to evaluate the failure strength and identify the failure location. For the Zr/Al interface, all failures occurred in the bulk aluminum. The average yield strength, ultimate strength, and strain at failure for the two parent samples were: 125 ± 10 MPa, 139 ± 24 MPa, 156 ± 21 MPa, 185 ± 14 MPa, 37.9 ± 5.6 %, and 29.7 ± 3.4 %, respectively. For specimens across the Zr/U-Mo interface, failures occurred either in the bulk Zr or U-Mo, with no failures observed in the diffusion region. For specimens that failed in the bulk Zr the failure strength and strain for the two parent samples were 570 MPa, 710 ± 131 MPa, and 43.3 %, 27.3 ± 6.6 % respectively. The specimens that failed in the bulk U-Mo had failure strengths and strains of 596 ± 32 MPa, 548 ± 124 MPa, and 2.2 ± 1.3 %, 1.5 ± 0.6 % respectively. In conclusion, these findings support the development of accurate thermo-mechanical models for irradiated fuel performance by identifying the mechanical limits and failure locations within the bonded regions.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Optimal Geometry for Focused Ion Beam-Milled Samples for Direct-Pull Micro-Tensile Testing Performed In Situ in a Scanning Electron Microscope

A thorough procedure was developed to efficiently manufacture dogbone samples using focused ion beam (FIB) milling for micro-tensile testing. A Bruker PI 89 PicoIndenter, Billerica, MA, USA, was used as a case study, although the analysis and results are applicable to other micro-mechanical testing systems capable of mounting a standard, Ø12.7 mm × Ø3.2 mm pin, scanning electron microscopy (SEM) pin stub (Ted Pella, Redding, CA, USA). Nine dogbones were made from an Fe-45Cu alloy additively manufactured using powder-fed laser-directed energy deposition (DED-LB). Testing showed that fracture was confined to the gauge section for all dogbones and that the fracture mode, ductile vs. brittle, was entirely dependent on the grain orientation relative to the loading direction. The analysis showed that the measured plastic strain to failure can vary from >11% (optimal geometry) to <1% (non-optimal geometry) in micro-tensile testing of high-tensile-strength (>1 GPa) metallic materials. Subsequently, a finite element analysis (FEA) was conducted to identify the improved dogbone geometries. A total of ten thousand dogbone geometries were tested, and their dimensions were defined by a set of four adjustable parameters (corner radius, load surface angle, load surface length, and dogbone head length). The gauge width and gauge length were fixed to 4 µm and 10 µm, respectively. Three-dimensional surface plots of the stress concentration as a function of two parameters were used to identify the optimal ranges of parameter values. The addition of maximum width and length constraints, measuring 25 µm and 30 µm, respectively, allowed us to identify an optimal geometry at load surface angles of 30° and 45°. Their respective dimensions (corner radius, load surface length, and dogbone head length) are, in µm, 12, 6, and 7 and 10, 7, and 7. Testing these two optimal geometries with a range of gauge lengths from 4 to 20 µm showed that smaller gauge lengths only slightly reduced the detrimental stress concentration outside the gauge section. However, smaller gauge lengths will notably improve the FIB surface polishing step as tapering is reduced with smaller dogbone lengths.

Chemistry↗

Quantification of grain boundary effects on the geometrically necessary dislocation density evolution and strain hardening of polycrystalline Mg 4Al using in situ tensile testing in scanning electron microscope and HR-EBSD

In situ tensile testing in a scanning electron microscope (SEM) in conjunction with high-resolution electron backscatter diffraction (HR-EBSD) under load was used to characterize the evolution of geometrically necessary dislocation (GND) densities at individual grain boundaries as a function of applied strain in a polycrystalline Mg—4Al alloy. The increase in GND density was investigated at plastic strains of 0 %, 0.6 %, 2.2 %, 3.3 % from the area including 76 grains and correlated with (i) geometric compatibility between slip systems across grain boundaries, and (ii) plastic incompatibility. We develop expressions for the grain boundary GND density evolution as a function of plastic strain and plastic incompatibility, from which uniaxial tensile stress-strain response of polycrystalline Mg—4Al are computed and compared with experimental measurement. The findings in this study contribute to understanding the mechanisms governing the strain hardening response of single-phase polycrystalline alloys and more reliable prediction of mechanical behaviors in diverse microstructures.

Geometrically necessary dislocations↗

Emerging hierarchical dislocation structures: Insights from scanning electron microscopy-electron backscatter diffraction in situ tensile testing and multifractal analysis

Understanding the evolution of dislocation structures during plastic deformation is critical for predicting the mechanical performance of metallic materials. In this work, we applied in situ scanning electron microscopy/electron backscatter diffraction tensile testing combined with multifractal (MF) analysis to assess deformation-induced dislocation structure evolution in solution-annealed 304 L stainless steel, both in its as-received and neutron-irradiated states (5.4 displacements per atom). The analysis of kernel average misorientation patterns revealed the formation of hierarchical dislocation arrangements that exhibit clear MF scaling behavior. Despite pronounced visual differences between nonirradiated and irradiated specimens—most notably, the appearance of dislocation channels after irradiation—the singularity spectra suggest that both conditions give rise to similar underlying hierarchical structures. MF analysis provides a quantitative measure of the spatial complexity and self-organization of dislocation patterns, highlighting the accelerated emergence and evolution of the dislocation structures in irradiated polycrystalline materials, as well as the limitation of their spatial extent. The findings indicate that irradiation not only modifies microstructure but also alters correlation-driven dislocation organization. More generally, they demonstrate that MF analysis is a powerful tool for probing mesoscale deformation mechanisms.

Dislocation structures↗

High Temperature Tensile Testing of Molybdenum Before and After Exposure in Flowing He at 600°C to 1000°C

ORNL supported NorthStar Medical Radioisotope’s accelerator-based concept to produce the medical isotope molybdenum-99 (Mo-99). The Mo targets are expected to experience in the accelerator temperature ranging from 200°C to 1000°C, and previous studies have demonstrated the embrittlement of Mo targets at room temperature when exposed to impure He at 800 to 1000°C. The goal of this project was to evaluate potential embrittlement at temperature ranging from 600°C to 1000°C for three Mo materials exposed at the same temperatures for 100h in high purity He (O 2 < 5ppm (µl/l)) with a flow rate of ~1m/s. Enriched Mo-100 (aMo) and conventional pressed and sintered Mo (UHP) disks were provided by NorthStar while low carbon arc cast rolled Mo, fabricated at ORNL, was used for comparison. The as fabricated rolled Mo exhibited superior tensile strength due to the alloy very fine grain size with limited ductility except at 1000°C with the elongation at rupture reaching 30%. The UHP Mo disks showed the lowest strength but highest ductility at 20-1000°C with significant strain hardening during tensile testing. The ductility of the aMo material was quite low at all temperatures due to a high density of voids at grain boundaries. Significant embrittlement of the aMo material was observed after exposure at 600°C to 1000°C, most likely because of oxygen diffusion and segregation at grain boundaries. No embrittlement was observed for the UHP Mo material, with excellent elongation at rupture for some of the specimens oxidized in He and tested at 600-1000°C. Significant variation in ductility from one UHP Mo specimen to another was, however, measured, both in the as fabricated and He-oxidized conditions. The rolled Mo was not affected by oxidation in He at 800°C, but a decrease in strength and increase in ductility was observed at 1000°C, likely due to the material recrystallization.

36 MATERIALS SCIENCE↗

The effect of dogbone sample size in the tensile testing of TATB-based plastic‑bonded explosive materials

Mechanical properties are of interest for many plastic‑bonded explosive (PBX) materials with tensile properties being of particular interest. Direct tensile measurements using dogbone-shaped samples are considered the gold standard, but they are fairly large, making testing more costly and less desirable from a safety perspective. We investigated whether the measured tensile strength depends on the dogbone specimen size, which to our knowledge, has not been reported in the literature for PBX materials. Understanding this should inform the feasibility of employing smaller samples and how sample size should be considered when comparing PBX dogbone values in the literature. The TATB-based PBX dogbone sample size was varied by (a) scaling all dimensions proportionally and (b) varying only the length of the samples. It was observed that the measured tensile peak stress (strength) was a function of the sample size, and was more dependent on the diameter (cross-sectional area) than the length of the samples. Since peak stress is calculated as peak force normalized to the diameter of the sample, one might not expect an explicit diameter dependence for the peak stress. Therefore, these results suggest there may be an additional strengthening effect as the sample diameter is increased.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of stacking fault energy and hydrogen on deformation mechanisms in high Mn austenitic steels during in-situ tensile testing

High Mn austenitic steels are considered an economical alloy system for hydrogen storage and transport applications. This study used stacking fault energy (SFE) as a design parameter to achieve hydrogen embrittlement (HE)-resistant high Mn austenitic alloys. The role of hydrogen on the deformation mechanisms of low (29 mJ/m 2 ) and high SFE (49 mJ/m 2 ) alloys was evaluated through in-situ neutron diffraction during tensile loading. Hydrogen-precharging increased yield strength, partly due to hydrogen-induced lattice distortion (i.e., solute strengthening). Hydrogen accelerated the increase in defect density, including dislocations and stacking faults. The formation of planar deformation structures (twins and stacking faults), relative to dislocations, plays a critical role in promoting hydrogen-assisted fracture. The stacking fault frequency parameter obtained from neutron diffraction quantifies planar deformation tendencies, correlated with HE sensitivity. The higher SFE alloy exhibited greater resistance to HE, associated with the reduced propensity to form stacking faults and twins upon deformation in the hydrogen-precharged condition.

High Mn austenitic steel↗

Unraveling the Highly Plastic Behavior of ALD-Aluminum Oxide Encapsulations by Small-Scale Tensile Testing

We present a study directly measuring the electron-beam-induced plasticity of amorphous Al 2 O 3 coatings. Core–shell nanostructures are employed as small-scale model systems for two-dimensional coatings made by atomic layer deposition (ALD). Copper nanowires (NWs) are used as substrates for ALD deposition, representing a model system for interconnects commonly found in integrated circuits. Experiments are performed in situ in a transmission electron microscope (TEM) and further analyzed with electron energy loss spectroscopy (EELS). Our in situ TEM tensile experiments reveal the highly plastic behavior of the ALD shell, which withstands a maximum strain of 188%. Comparable samples under beam-off conditions show a brittle fracture, which underlines the effect of electron irradiation. The electron-beam-activated bond switching within the amorphous network enables compensation of the applied tensile strain, leading to viscous flow. By incorporating an intermediate nanocrystalline layer within the Al 2 O 3 shell, the plasticity is suppressed and brittle fracture occurs. This work directly demonstrates the tuning of mechanical properties in amorphous ALD structures through electron irradiation.

36 MATERIALS SCIENCE↗

Small scale tensile testing technique for measuring grain boundary strength of neutron-irradiated materials in focused ion beam systems

Irradiation induced defects on grain boundaries (GBs) can lead to GB strength degradation and cause intergranular cracking in structural materials, affecting the safe operation and service life of nuclear reactors. Establishing the quantitative relationship between the strength and character/microchemistry for individual GB in an effort of integrating experimental measurements and multiscale simulations.

36 MATERIALS SCIENCE↗