Search NASA⌕ Search

SEARCH · Search NASA

Results for “Test Engineering Fixture Design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Optimization of an Impedance-Matched Test Fixture with the Modal Projection Error

Across many industries and engineering disciplines, components and systems are designed and deployed into their operational environment of intended use. It is the desire of the design agency to be able to predict whether their component or system will function in its shock and vibration environments or if it will fail due to mechanical stresses. One method to determine if the component will survive the shock and vibration environments is to expose the component to the operational environment in a laboratory. One difficulty in executing a representative laboratory test is that the component may not have the same boundary condition in the laboratory as in the operational configuration. This paper examines the use of parameterized optimization to design the test fixture in order to better match the operational configuration. Several frequency and modal-based objective functions are examined for the optimization. The study shows that the Modal Projection Error objective function performs the best of the functions studied. The efficacy of the Modal Projection Error is demonstrated with respect to dynamic test fixture design on several analytical and experimental exemplars.

dynamic↗

Vibration Fixture Design and Testing for Rigid - Y Cable Mount on MMRTG F4

INL is responsible for the fueling and testing of Radioisotope Thermoelectric Generators for NASA space missions. For the upcoming NASA mission "DRAGONFLY," INL is tasked with fueling and testing the Multi-Mission Radioisotope Thermoelectric Generator F4 (MMRTG F4). This involves conducting various tests, such as vibration testing and mass properties testing. For these tests, an interface is required between the MMRTG and the testing equipment, provided by cables mounted on a legacy bracket. Due to design changes in the cooling lines, a new cable – the Rigid Y cable – is to be used. The test described in this poster was to verify if the Rigid Y cable would survive the vibration tests. The results will determine the procedure for conducting the vibration tests on the MMRTG F4.

42 - ENGINEERING↗

A simulation study of test fixture attachment points for vibration test optimization (MEEN 5440 Final Project)

The aerospace industry uses vibration shaker tables to perform component durability testing. These dynamic environments tests often have a hard time replicating the service environment of a component due to a mismatch in the applied force or the boundary condition. Figure 1 shows the desired outcome of a dynamic environments test. The measured responses in a lab test, ideally, should match the measured response of the service environment field test. One way to address the mismatch between field environment and lab environment is with test fixture design. The test fixture attaches the component under test to the shaker table. Single-axis shakers are the industry standard type of shaker table, and, therefore, test fixtures are often rigid in order to minimize cross-axis responses.

42 ENGINEERING↗

Challenges in practical button cell testing for hydrogen production from high temperature electrolysis of water

High temperature electrolysis of water using solid oxide electrochemical cells (SOEC) is a promising technology for hydrogen production with high energy efficiency and may promote decarbonization when coupled with renewable energy sources and excess heat from nuclear reactors. Over the past several decades there have been extensive scientific and engineering studies on cell materials and degradation behaviors that have greatly improved current density, decreased total resistance, and lowered degradation rates. Although the technology is now at a near-commercial level, maintaining consistency in cell testing and minimizing variance in practical testing environments is an often overlooked but crucial topic. To promote high quality data collection, testing procedures and balance of plant component details are extremely important to consider. This work discusses some key factors affecting the reproducibility of practical SOEC testing on the button cell level, namely, current collection layers, cell sealing procedures, the reliability of steam and hydrogen delivery systems, cell testing fixture design, and reduction procedures. To provide a baseline and a level of standardization for the SOEC community, this work also discloses details of the standard operating procedure and techniques adopted for o-SOEC testing at Idaho National Laboratory (INL).

08 HYDROGEN↗

Memorial Pools Energy Efficiency Retrofits

The National September 11 Memorial & Museum completed a retrofit of the submergible LED lighting fixtures in its North and South Memorial Pools, located at the World Trade Center site in New York City. The two one-acre pools are illuminated nightly by custom LED fixtures set into their base, and the original lights — in place since 2011 — had begun reaching the end of their useful life, leaving sections of the pools dim or dark. Rather than fully replacing the fixtures, the project team worked with the original manufacturer, Acuity Brands, to retrofit and reuse existing components across all eight pool walls (34 fixtures per wall), reducing cost and waste. Fixtures were shipped in custom crates to Minnesota for retrofitting, then reinstalled onsite by Memorial & Museum staff and contractor ABM. The team addressed two key technical challenges during the project: early leakage in retrofitted fixtures, resolved by introducing vacuum-sealing and nitrogen-fill testing before shipment; and chord damage during transit, resolved with custom-designed shipping crates. All eight pool walls were successfully retrofitted and reinstalled by August 27, 2025, ahead of the 25th anniversary of the September 11, 2001 attacks. Sitewide electrical consumption in September 2025 reflected an approximate 7% reduction, contributing to the institution's broader net-zero and LEED Gold sustainability goals.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Stabilizing a strongly nonlinear structure through shaker dynamics in fixed frequency voltage control tests

Bifurcations are commonly encountered during force controlled swept and stepped sine testing of nonlinear structures, which generally leads to the so-called jump-down or jump-up phenomena between stable solutions. There are various experimental closed-loop control algorithms, such as control-based continuation and phase-locked loop, to stabilize dynamical systems through these bifurcations, but they generally rely on specialized control algorithms that are not readily available with many commercial data acquisition software packages. A recent method was developed to experimentally apply sequential continuation using the shaker voltage that can be readily deployed using commercially available software. By utilizing the stabilizing effects of electrodynamic shakers and the force dropout phenomena in fixed frequency voltage control sine tests, this approach has been demonstrated to stabilize the unstable branch of a nonlinear system with three branches, allowing for three multivalued solutions to be identified within a specific frequency bandwidth near resonance. Recent testing on a strongly nonlinear system with vibro-impact nonlinearity has revealed jumping behavior when performing sequential continuation along the voltage parameter, like the jump phenomena seen during more traditional force controlled swept and stepped sine testing. Here, this paper investigates the stabilizing effects of an electrodynamic shaker on strongly nonlinear structures in fixed frequency voltage control tests using both numerical and experimental methods. The harmonic balance method is applied to the coupled shaker-structure system with an electromechanical model to simulate the fixed voltage control tests and predict the stabilization for different parameters of the model. The simulated results are leveraged to inform the design of a set of experiments to demonstrate the stabilization characteristics on a fixture-pylon assembly with a vibro-impact nonlinearity. Through numerical simulation and experimental testing on two different strongly nonlinear systems, the various parameters that influence the stability of the coupled shaker-structure are revealed to better understand the performance of fixed frequency voltage control tests.

42 ENGINEERING↗

Mu2e Target Thermal Test Project

The Mu2e experiment requires a production target capable of operating under extreme thermal conditions caused by an 8 GeV proton beam. This project’s objective supports the development of the Mu2e Production Target by testing the Stickman model’s thermal behavior. To test this, Angel Flores Luviano has assisted Jonathan Williams in progressing this project by contributing to the development of a Radiative Cooling Test Fixture (RCTF) that will be used to evaluate the thermal behavior of the new production target model. Engineering calculations were performed to analyze thermal performance and pressure drop within the cold well and water cooling circuit, and determine optimal sizing for key components of the water system. An engineering note was made to document the calculations. CAD models of the water circuit piping, thermocouple mount, and radiator chimney were developed, and prototype test rig components were fabricated using 3D printing. Future work will focus on conti nued RCTF development which includes control system integration, heater hardware design, and interfaces that can be scaled up to increase thermal capacity.

Luviano, Angel Flores [Unlisted]↗

Mu2e Production Target Thermal Test Project

The Mu2e experiment requires a production target that is capable of operating under extreme thermal conditions caused by an 8 GeV proton beam. This project’s objective supports the development of the Mu2e Pro- duction Target by testing the Stickman model’s thermal behavior. Angel Flores Luviano has assisted Jonathan Williams in progressing this project by contributing to the development of a Radiative Cooling Test Fixture (RCTF) that will be used to evaluate the thermal behavior of the new production target model. Engineering calculations were performed to an- alyze thermal performance and pressure drop within the cold well and wa- ter cooling circuit. These calculations also determined the optimal sizing for key components of the water system. An engineering note was made to document these calculations. CAD models of the water circuit piping, thermocouple mounting bars, and radiator chimney were developed, and prototype test rig components were fabricated using 3D printing. Future work will focus on continued RCTF development which includes control system integration, heater hardware design, and interfaces that can be scaled up to increase thermal capacity.

Flores Luviano, Angel Augusto [Unlisted, US]↗