Search NASA⌕ Search

SEARCH · Search NASA

Results for “Test program”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

EXPERT PANEL OVERSIGHT COMMITTEE ASSESSMENT OF FY2008 CORROSION AND STRESS CORROSION CRACKING SIMULANT TESTING PROGRAM

The Expert Panel Oversight Committee (EPOC) has been overseeing the implementation of selected parts of Recommendation III of the final report, Expert Panel workshop for Hanford Site Double-Shell Tank Waste Chemistry Optimization, RPP-RPT-22126. Recommendation III provided four specific requirements necessary for Panel approval of a proposal to revise the chemistry control limits for the Double-Shell Tanks (DSTs). One of the more significant requirements was successful performance of an accelerated stress corrosion cracking (SCC) experimental program. This testing program has evaluated the optimization of the chemistry controls to prevent corrosion in the interstitial liquid and supernatant regions of the DSTs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CERCA LEU fuel assemblies testing in Maria Reactor - safety analysis summary and testing program scope.

The presented paper contains neutronic and thermal-hydraulic (for steady and unsteady states) calculation results prepared to support annex to Safety Analysis Report for MARIA reactor in order to obtain approval for program of testing low-enriched uranium (LEU) lead test fuel assemblies (LTFA) manufactured by CERCA. This includes presentation of the limits and operational constraints to be in effect during the fuel testing investigations. Also, the scope of testing program (which began in August 2009), including additional measurements and monitoring procedures, is described.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hanford double-shell tank testing program - 15341

The corrosion testing program and Hanford regularly tests waste chemistries to analyze threats and develop new corrosion chemistry guidelines. Over the past few years, the focus of testing has been on the threat of leaked wastes in Tank 241-AY-102 (AY-102). From the tests conducted to date, it appears that the potential waste compositions in the annulus of tank AY-102 do not show a propensity for localized corrosion or stress corrosion cracking. The threat of exterior corrosion from the liquid and moisture in the leak detection pit (LDP) is a potential concern that will continue to be evaluated in the coming year. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimal and Nominal Nuclear Testing Programs

The intent of this paper is to encourage thought on what the Test Site Verification Team (TSVT) might encounter primarily in terms of observable infrastructure when deployed to assess and verify an explosion, and/or a nuclear-testing program, site, or facility. A primary objective is to present the concept of a continuum of nuclear-testing programs between optimal and nominal end members as defined primarily by their observable infrastructure. Key objectives are: 1. Define optimal and nominal nuclear testing programs; 2. Discuss underground development for nuclear operations; 3. Discuss underground nuclear operations, safety, and health; 4. Compare drift complexes of optimal and nominal testing programs; 5. Compare drift complexes for nuclear testing and commercial production; 6. Discuss a potential future look of underground development and operations. A secondary objective is to interpret the intent of the three TSVT verification scenarios, primarily by defining “consistent with” nuclear or non-nuclear or listing criteria that “verify” nuclear or non-nuclear. Before discussing optimal and nominal nuclear testing programs, an understanding of the three verification scenarios is deemed beneficial.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Test Site Verification Team: Optimal and Nominal Nuclear-Testing Programs [Slides]

Objectives of the Optimal and Nominal Nuclear-Testing Programs: Define optimal and nominal nuclear-testing programs; Discuss underground development for nuclear operations; Discuss underground nuclear operations, safety, and health; Compare drift complexes of optimal and nominal testing programs; Compare drift complexes for nuclear testing and commercial production; Discuss a potential future look of underground development and operations.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Comparison of Statistical Methods for Detector Testing Programs

A typical goal for any detector testing program is to ascertain not only the performance of the detector systems under test, but also the confidence that systems accepted using that testing program’s acceptance criteria will exceed a minimum acceptable performance (which is usually expressed as the minimum acceptable success probability, p). A similar problem often arises in statistics, where we would like to ascertain the fraction, p, of a population of items that possess a property that may take one of two possible values. Typically, the problem is approached by drawing a fixed sample of size n, with the number of items out of n that possess the desired property, x, being termed successes. The sample mean gives an estimate of the population mean p ≈ x/n, although usually it is desirable to accompany such an estimate with a statement concerning the range within which p may fall and the confidence associated with that range. Procedures for establishing such ranges and confidence limits are described in detail by Clopper, Brown, and Agresti for two-sided symmetric confidence intervals.

97 MATHEMATICS AND COMPUTING↗

Launching a saliva-based SARS-CoV-2 surveillance testing program on a university campus

Regular surveillance testing of asymptomatic individuals for SARS-CoV-2 has been center to SARS-CoV-2 outbreak prevention on college and university campuses. Here we describe the voluntary saliva testing program instituted at the University of California, Berkeley during an early period of the SARS-CoV-2 pandemic in 2020. The program was administered as a research study ahead of clinical implementation, enabling us to launch surveillance testing while continuing to optimize the assay. Results of both the testing protocol itself and the study participants’ experience show how the program succeeded in providing routine, robust testing capable of contributing to outbreak prevention within a campus community and offer strategies for encouraging participation and a sense of civic responsibility.

59 BASIC BIOLOGICAL SCIENCES↗

RIA Testing Program for ATF

Presentation on the RIA Testing Program for ATFs at TREAT for the 11th Annual EPRI/DOE/INL Joint Workshop on Accident Tolerant Fuel

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SAS4A/SASSYS-1 Validation with EBR-II Tests Performed During the SHRT Testing Program

The EBR-II sodium-cooled fast reactor supported a wide range of fast reactor research activities. The final fifteen years of operations at EBR-II were used for experiments and tests to demonstrate the importance of passive safety in liquid metal reactors and the capability of such systems to provide strong passive responses during off-normal conditions. The Shutdown Heat Removal Test program at EBR-II provided test data supporting the validation of computer codes for design, licensing, and operation of LMRs, among other objectives. The program included nearly sixty tests, most of which were protected and unprotected loss of flow and loss of heat sink tests run at various initial powers and flow rates. This report documents the results of modeling and simulation of tests from the Shutdown Heat Removal Test program to support validation of Argonne’s SAS4A/SASSYS-1 fast reactor safety analysis code. SHRT-17 was a protected loss of flow test where a loss of electrical power to all sodium coolant pumps was simulated to demonstrate the effectiveness of natural circulation cooling characteristics. SHRT-45R was an unprotected loss of flow test where the control rod scram function of the plant protection system was disabled to demonstrate the effectiveness of EBR-II’s passive reactivity feedbacks. BOP-301 and BOP-302R were unprotected loss of heat sink tests that demonstrated how reactivity feedback effects driven by changes to the core inlet temperature can shut down the fission process. This validation activity leverages modeling and simulation efforts that originated under an International Atomic Energy Agency Coordinated Research Project for benchmark analysis of the EBR-II Shutdown Heat Removal Tests. The SAS4A/SASSYS-1 models originally developed for the CRP have been modernized to utilize new code features and modeling practices. Differences between the predicted and measured test data were explored and the causes of these differences were identified as being due to modeling approximations, uncertainty in transient component behavior, and instrumentation uncertainties. Overall, it was concluded that for SHRT-17, SHRT-45R, BOP-301, and BOP-302R there was good agreement between the flow, power, and temperature predictions and the measured data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SAS4A/SASSYS-1 Validation with EBR-II Tests Performed During the SHRT Testing Program (Rev. 2)

The EBR-II sodium-cooled fast reactor supported a wide range of fast reactor research activities. The final fifteen years of operations at EBR-II were used for experiments and tests to demonstrate the importance of passive safety in liquid metal reactors and the capability of such systems to provide strong passive responses during off-normal conditions. The Shutdown Heat Removal Test program at EBR-II provided test data supporting the validation of computer codes for design, licensing, and operation of LMRs, among other objectives. The program included nearly sixty tests, most of which were protected and unprotected loss of flow and loss of heat sink tests run at various initial powers and flow rates. This report documents the results of modeling and simulation of tests from the Shutdown Heat Removal Test program to support validation of Argonne’s SAS4A/SASSYS-1 fast reactor safety analysis code. SHRT-17 and SHRT-6 were protected loss of flow tests where a loss of electrical power to all sodium coolant pumps was simulated to demonstrate the effectiveness of natural circulation cooling characteristics. SHRT-45R, SHRT-39, and SHRT-43R were unprotected loss of flow tests where the control rod scram function of the plant protection system was disabled to demonstrate the effectiveness of EBR-II’s passive reactivity feedbacks. BOP-301 and BOP-302R were unprotected loss of heat sink tests that demonstrated how reactivity feedback effects driven by changes to the core inlet temperature can shut down the fission process. PICT-5/6 demonstrated how core power could be increased and decreased via changes in the intermediate sodium and feedwater flow rates. This validation activity leverages modeling and simulation efforts that originated under an International Atomic Energy Agency Coordinated Research Project for benchmark analysis of the EBR-II Shutdown Heat Removal Tests. The SAS4A/SASSYS-1 models originally developed for the CRP have been modernized to utilize new code features and modeling practices. Differences between the predicted and measured test data were explored and the causes of these differences were identified as being due to modeling approximations, uncertainty in transient component behavior, and instrumentation uncertainties. Overall, it was concluded that for all tests simulated there was good agreement between the flow, power, and temperature predictions and the measured data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

CLIC RF High Power Production Testing Program

The CLIC Power Extraction and Transfer Structure (PETS) is a passive microwave device in which bunches of the drive beam interact with the impedance of the periodically loaded waveguide and generate RF power for the main linac accelerating structure. The demands on the high power production ({approx} 150 MW) and the needs to transport the 100 A drive beam for about 1 km without losses, makes the PETS design rather unique and the operation very challenging. In the coming year, an intense PETS testing program will be implemented. The target is to demonstrate the full performance of the PETS operation. The testing program overview and test results available to date are presented.

43 PARTICLE ACCELERATORS↗

ChargeX Prescribed Testing Program at CharIN June 2024 Testival: Outcomes & Future Recommendations

In June 2024, the ChargeX Consortium developed an optional prescribed testing program for electric vehicle (EV) and electric vehicle supply equipment (EVSE) manufacturers that attended the CharIN Testival as testers. There were two driving purposes of this program; to introduce a new hybrid approach to testing events with both ad-hoc and prescribed testing offered, and to demonstrate the test cases and structure effectiveness of the EV-EVSE Interoperability Test Plan (EEITP) document developed within the ChargeX Testing Task Force. This program contained eight test scenarios to be performed during the final 30-minutes of a 90-minute testing slot with details like purpose, setup, pass criteria, etc. included within a written test plan document. A $2,000 rebate was offered to those who participated, and a ChargeX moderation force was present to collect EV and EVSE meta data, testing meta data, and testing results.

33 ADVANCED PROPULSION SYSTEMS↗

Integrated test program for comparison of {sup 10}B lined proportional counting systems with {sup 3}He based counters for safeguards applications

To address the urgent need to find a viable {sup 3}He replacement technology, Los Alamos National Laboratory has developed an integrated test program for performance evaluation of {sup 3}He replacement technologies with focus on safeguards specific parameters. In addition, a dedicated experimental setup was built to support the experimental activities. Current activity focuses on evaluation of {sup 10}B lined proportional counters. This paper presents an overview of the test program as well as the first results from the GE/Reuter-Stokes {sup 10}B lined system. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress Update on the Waste Treatment and Immobilization Plant Pulse- Jet Mixed Vessel Testing Program - 16286

The Waste Treatment and Immobilization Plant (WTP) is designed to use cylindrical-shaped pulse-jet mixers in the black cell vessels to mix the radioactive waste during process operations. Pulse-jet mixers operate like large turkey basters, using air pressure to suck radioactive waste up into the mixer and eject it back into the vessel at high velocity. Using pulse-jet mixers for keeping waste in process vessels adequately mixed is one of the design features that ensures that there are no mechanical parts inside the black cells that would require maintenance. The WTP Project is conducting a testing program to ensure the pulse-jet mixed vessels can address three design and nuclear safety concerns: 1) pulse jet mixer controls, 2) hydrogen gas generation, and 3) the potential for inadvertent criticality in the vessels. The currently planned pulse-jet mixed vessel testing program is divided into three major test campaigns. The first campaign consists of testing to demonstrate pulse-jet mixed vessel control system design and operating concepts. The second test campaign consisted of informational testing of select prototypic PJM vessel features in a reduced scale facility. This testing informed decision making on selection of different mixing system configurations. This test campaign was completed in March 2015. The third test campaign is planned to test the complete functionality of a pulse-jet mixed vessel at full-scale using a prototype standardized high-solids vessel design. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Large-Grain Superconducting Gun Cavity Testing Program Phase One Closing Report

This report details the experimental configuration and RF testing results for the first phase of a large-grained niobium electron gun cavity testing program being conducted in the Small Vertical Testing Facility in the Collider-Accelerator Department. This testing is meant to explore multi-pacting in the cavity and shed light on the behavior of a counterpart cavity of identical geometry installed in the Energy Recovery LINAC being constructed in the Collider-Accelerator Department at Brookhaven National Laboratory. This test found that the Q of the large-grained cavity at 4 K reached ~6.5 × 10 8 and at 2 K reached a value of ~6 × 10 9 . Both of these values are about a factor of 10 lower than would be expected for this type of cavity given the calculated surface resistance and the estimated geometry factor for this half-cell cavity. In addition, the cavity reached a peak voltage of 0.6 MV before there was sig-nificant decline in the Q value and a substantial increase in field emission. This relatively low volt-age, coupled with the low Q and considerable field emission suggest contamination of the cavity interior, possibly during experimental assembly. The results may also suggest that additional chemical etching of the interior surface of the cavity may be beneficial. Throughout the course of testing, various challenges arose including slow helium transfer to the cryostat and cable difficulties. These difficulties and others were eventually resolved, and the re-port discusses the operating experience of the experiment thus far and the plans for future work aimed at exploring the nature of multipacting with a copper cathode inserted into the cavity.

43 PARTICLE ACCELERATORS↗

ORNL Package Testing Program Software Quality Assurance Plan

The Oak Ridge National Laboratory (ORNL) Package Testing Program (PTP) uses commercial off-the-shelf (COTS) software in performing data collection of thermal test results for package designs that contain radioactive materials. Specifically, this software is used to collect temperature data from the furnace, packages, and ambient air to prepare and execute the thermal test specified in 10 CFR 71.73, “Thermal Test.” This software quality assurance (SQA) plan sets forth the guidelines, standards, and procedures that shall be used to provide SQA for PTP software applications. This is a living document that will be maintained for the lifecycle of the PTP program. The SQA plan follows the requirements set forth in ORNL Standards Based Management System (SBMS): Information Technology; Subject Area: Software Quality Assurance. When applicable to the requirements as described in ORNL SBMS, Software Quality Assurance, the software shall be listed in the ORNL Software Registration System (SRS). Exemptions to this SBMS are COTS and firmware that are not modified; spreadsheet applications and personal productivity tools that do not have a utility or safety application, research applications, legacy software, system software, vendor-supplied software used to interface with the vendor’s services, software used within the organization to facilitate processing or management of information, and software developed for applications not specific to the US Department of Energy (DOE).

97 MATHEMATICS AND COMPUTING↗

FY19 Report for Instrumentation Development for the Transient Testing Program

This report details the technical activities and accomplishment carried out under funding from the Department of Energy (DOE) Nuclear Technology Research and Development (NTRD) program for in-pile instrumentation supporting the transient testing program in FY19. These activities were performed in support of cross-cutting transient testing experiment objectives. The purpose of this report is to provide a summary of key technical work, of particular interest to nuclear irradiation test experimenters and in-pile instrumentation engineers. During FY19, development activities are focused on deployment of devices to perform online measurement of neutron flux, temperature, and mechanical behaviors in nuclear fuels experiments. Specifically, these R&D activities include in-pile investigations at the Transient Reactor Test (TREAT) facility throughout the year. Other in-pile instrumentation R&D activities are being carried out under other DOE programs, which may be recognized but not the focus of this document. A brief summary of activities and accomplishments is first provided for each major activity. More detailed summaries are presented in appendices.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FY20 Report for Instrumentation Development for the Transient Testing Program

This yearly report provides a summary of accomplishments carried out under funding from the Department of Energy (DOE) Nuclear Technology Research and Development (NTRD) program for in-pile instrumentation supporting the transient testing program in FY20. These activities were performed in support of cross-cutting transient testing experiment objective. In this year, specific instrument R&D has been a lesser priority to years past, with complementary instrumentation R&D being ramped up under the DOE Advanced Sensors and Instrumentation Program. The primary focus of the work in FY20 pertain to defining a process and system, developed over the past several years, for developing, qualifying, and deploying instrumentation in in-pile experiments. The purpose of this report is to provide a summary of these outcomes and be a reference for researchers that are interested in developing in-pile instrumentation, with a particular emphasis on the Transient Reactor Test (TREAT) facility for deployment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗