A modern Monte Carlo investigation of the TG-43 dosimetry parameters for an {sup 125}I seed already having AAPM consensus data

Purpose: To investigate potential causes for differences in TG-43 brachytherapy dosimetry parameters in the existent literature for the model IAI-125A{sup 125}I seed and to propose new standard dosimetry parameters. Methods: The MCNP5 code was used for Monte Carlo (MC) simulations. Sensitivity of dose distributions, and subsequently TG-43 dosimetry parameters, was explored to reproduce historical methods upon which American Association of Physicists in Medicine (AAPM) consensus data are based. Twelve simulation conditions varying{sup 125}I coating thickness, coating mass density, photon interaction cross-section library, and photon emission spectrum were examined. Results: Varying{sup 125}I coating thickness, coating mass density, photon cross-section library, and photon emission spectrum for the model IAI-125A seed changed the dose-rate constant by up to 0.9%, about 1%, about 3%, and 3%, respectively, in comparison to the proposed standard value of 0.922 cGy h{sup −1} U{sup −1}. The dose-rate constant values by Solberg et al. [“Dosimetric parameters of three new solid core {sup 125}I brachytherapy sources,” J. Appl. Clin. Med. Phys. 3, 119–134 (2002)], Meigooni et al. [“Experimental and theoretical determination of dosimetric characteristics of IsoAid ADVANTAGE™ {sup 125}I brachytherapy source,” Med. Phys. 29, 2152–2158 (2002)], and Taylor and Rogers [“An EGSnrc Monte Carlo-calculated database of TG-43 parameters,” Med. Phys. 35, 4228–4241 (2008)] for the model IAI-125A seed and Kennedy et al. [“Experimental and Monte Carlo determination of the TG-43 dosimetric parameters for the model 9011 THINSeed™ brachytherapy source,” Med. Phys. 37, 1681–1688 (2010)] for the model 6711 seed were +4.3% (0.962 cGy h{sup −1} U{sup −1}), +6.2% (0.98 cGy h{sup −1} U{sup −1}), +0.3% (0.925 cGy h{sup −1} U{sup −1}), and −0.2% (0.921 cGy h{sup −1} U{sup −1}), respectively, in comparison to the proposed standard value. Differences in the radial dose functions between the current study and both Solberg et al. and Meigooni et al. were <10% for r ≤ 5 cm, and increased for r > 5 cm with a maximum difference of 29% at r = 9 cm. In comparison to Taylor and Rogers, these differences were lower (maximum of 2% at r = 9 cm). For the similarly designed model 6711 {sup 125}I seed, differences did not exceed 0.5% for 0.5 ≤ r ≤ 10 cm. Radial dose function values varied by 1% as coating thickness and coating density were changed. Varying the cross-section library and source spectrum altered the radial dose function by 25% and 12%, respectively, but these differences occurred at r = 10 cm where the dose rates were very low. The 2D anisotropy function results were most similar to those of Solberg et al. and most different to those of Meigooni et al. The observed order of simulation condition variables from most to least important for influencing the 2D anisotropy function was spectrum, coating thickness, coating density, and cross-section library. Conclusions: Several MC radiation transport codes are available for calculation of the TG-43 dosimetry parameters for brachytherapy seeds. The physics models in these codes and their related cross-section libraries have been updated and improved since publication of the 2007 AAPM TG-43U1S1 report. Results using modern data indicated statistically significant differences in these dosimetry parameters in comparison to data recommended in the TG-43U1S1 report. Therefore, it seems that professional societies such as the AAPM should consider reevaluating the consensus data for this and others seeds and establishing a process of regular evaluations in which consensus data are based upon methods that remain state-of-the-art.

61 RADIATION PROTECTION AND DOSIMETRY↗

Limitations of the TG-43 formalism for skin high-dose-rate brachytherapy dose calculations

Purpose: In skin high-dose-rate (HDR) brachytherapy, sources are located outside, in contact with, or implanted at some depth below the skin surface. Most treatment planning systems use the TG-43 formalism, which is based on single-source dose superposition within an infinite water medium without accounting for the true geometry in which conditions for scattered radiation are altered by the presence of air. The purpose of this study is to evaluate the dosimetric limitations of the TG-43 formalism in HDR skin brachytherapy and the potential clinical impact. Methods: Dose rate distributions of typical configurations used in skin brachytherapy were obtained: a 5 cm × 5 cm superficial mould; a source inside a catheter located at the skin surface with and without backscatter bolus; and a typical interstitial implant consisting of an HDR source in a catheter located at a depth of 0.5 cm. Commercially available HDR{sup 60}Co and {sup 192}Ir sources and a hypothetical {sup 169}Yb source were considered. The Geant4 Monte Carlo radiation transport code was used to estimate dose rate distributions for the configurations considered. These results were then compared to those obtained with the TG-43 dose calculation formalism. In particular, the influence of adding bolus material over the implant was studied. Results: For a 5 cm × 5 cm{sup 192}Ir superficial mould and 0.5 cm prescription depth, dose differences in comparison to the TG-43 method were about −3%. When the source was positioned at the skin surface, dose differences were smaller than −1% for {sup 60}Co and {sup 192}Ir, yet −3% for {sup 169}Yb. For the interstitial implant, dose differences at the skin surface were −7% for {sup 60}Co, −0.6% for {sup 192}Ir, and −2.5% for {sup 169}Yb. Conclusions: This study indicates the following: (i) for the superficial mould, no bolus is needed; (ii) when the source is in contact with the skin surface, no bolus is needed for either {sup 60}Co and {sup 192}Ir. For lower energy radionuclides like {sup 169}Yb, bolus may be needed; and (iii) for the interstitial case, at least a 0.1 cm bolus is advised for {sup 60}Co to avoid underdosing superficial target layers. For {sup 192}Ir and {sup 169}Yb, no bolus is needed. For those cases where no bolus is needed, its use might be detrimental as the lack of radiation scatter may be beneficial to the patient, although the 2% tolerance for dose calculation accuracy recommended in the AAPM TG-56 report is not fulfilled.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of TG-43 and TG-186 in breast irradiation using a low energy electronic brachytherapy source

Purpose: The recently updated guidelines for dosimetry in brachytherapy in TG-186 have recommended the use of model-based dosimetry calculations as a replacement for TG-43. TG-186 highlights shortcomings in the water-based approach in TG-43, particularly for low energy brachytherapy sources. The Xoft Axxent is a low energy (<50 kV) brachytherapy system used in accelerated partial breast irradiation (APBI). Breast tissue is a heterogeneous tissue in terms of density and composition. Dosimetric calculations of seven APBI patients treated with Axxent were made using a model-based Monte Carlo platform for a number of tissue models and dose reporting methods and compared to TG-43 based plans. Methods: A model of the Axxent source, the S700, was created and validated against experimental data. CT scans of the patients were used to create realistic multi-tissue/heterogeneous models with breast tissue segmented using a published technique. Alternative water models were used to isolate the influence of tissue heterogeneity and backscatter on the dose distribution. Dose calculations were performed using Geant4 according to the original treatment parameters. The effect of the Axxent balloon applicator used in APBI which could not be modeled in the CT-based model, was modeled using a novel technique that utilizes CAD-based geometries. These techniques were validated experimentally. Results were calculated using two dose reporting methods, dose to water (D{sub w,m}) and dose to medium (D{sub m,m}), for the heterogeneous simulations. All results were compared against TG-43-based dose distributions and evaluated using dose ratio maps and DVH metrics. Changes in skin and PTV dose were highlighted. Results: All simulated heterogeneous models showed a reduced dose to the DVH metrics that is dependent on the method of dose reporting and patient geometry. Based on a prescription dose of 34 Gy, the average D{sub 90} to PTV was reduced by between ∼4% and ∼40%, depending on the scoring method, compared to the TG-43 result. Peak skin dose is also reduced by 10%–15% due to the absence of backscatter not accounted for in TG-43. The balloon applicator also contributed to the reduced dose. Other ROIs showed a difference depending on the method of dose reporting. Conclusions: TG-186-based calculations produce results that are different from TG-43 for the Axxent source. The differences depend strongly on the method of dose reporting. This study highlights the importance of backscatter to peak skin dose. Tissue heterogeneities, applicator, and patient geometries demonstrate the need for a more robust dose calculation method for low energy brachytherapy sources.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-488: Comparison of the TG-51 and TG-51 Addendum Calibration Protocols

Purpose: To quantify differences between the TG51 and TG51 addendum calibration protocols. Methods: Beam energies of 6X, 6XSRS, 10X, 15X, 23X, 6XFFF, and 10XFFF were calibrated following both the TG51 and TG51 addendum protocols using both a Farmer and a scanning ionization chamber with traceable absorbed dose-to-water calibrations. For the TG51 addendum procedure, the collimating jaws were positioned to define a 10×10cm{sup 2} radiation field, a lead foil was only used for kQ measurements of FFF energies, and a volume-averaging correction was applied based on crossline and inline dose profiles. For the TG51 procedure, the collimating jaws were set to 10×10cm{sup 2} according to the digital readout, and a lead foil was used for kQ measurements of energies greater than 10MV. Results: For beam energies with a flattening filter, absorbed dose-to-water determined by the two protocols differed by 0.1%–0.3%. For FFF beam energies, differences between the protocols were up to 0.2% and 0.8% for the scanning and Farmer ionization chambers, respectively. Differences between the protocols were due to kQ determination, volume-averaging correction, and measurement of raw ionization. Differences in kQ values between the two protocols were up to 0.4% and 0.2% for the scanning and Farmer ionization chambers, respectively. Volume-averaging corrections were less than 0.1% for the scanning ionization chamber, and up to 0.4% and 0.6% for the Farmer ionization chamber in beams with a flattening filter and FFF beams, respectively. Raw ionization measurements differed up to 0.3%±0.07% due to differences in jaw settings. Conclusion: The TG51 and TG51 addendum calibration protocols differed less than 0.3% for the scanning ionization chamber. For the Farmer chamber in FFF energies, volume-averaging corrections of up to 0.6% contributed to calibration differences of up to 0.8%. Failure to verify the radiation field size can produce calibration differences of up to 0.3%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SST-TG-P1F4R3200: Decaying Stably-Stratified Turbulence (SST), Initialized Using Taylor-Green Vortices (TG) at Prandtl Number Pr=1, Froude Number Fr=4, Reynolds Number Re=3200

This dataset comprises direct numerical simulations (DNS) of decaying stably-stratified turbulence influenced by a linear background density gradient, initialized using an array of Taylor-Green vortices, as described in [Riley & de Bruyn Kops (2003)](https://doi.org/10.1063/1.1578077). The initial Prandtl, Froude, and Reynolds numbers are (Pr, Fr, Re) = (1, 4, 3200). A total of 15,000 snapshots are recorded at uniform time intervals, each with a spatial resolution of 512x512x256 grid points. Four flow variables are associated with each snapshot: the three velocity components (u,v,w) and the perturbed density field (rho) away from the background gradient. All fields are stored in binary format (32-bit little-endian), each with a size of 255 MB, yielding a total dataset size of 15.3 TB. Further details are referenced in the attached README file, and a current list of publications and associated analysis tools are provided at https://stratified-turbulence.github.io/web/.

42 ENGINEERING↗

SST-TG-P50F4R3200: Decaying Stably-Stratified Turbulence (SST), Initialized Using Taylor-Green Vortices (TG) at Prandtl Number Pr=50, Froude Number Fr=4, Reynolds Number Re=3200

This dataset comprises direct numerical simulations (DNS) of decaying stably-stratified turbulence influenced by a linear background density gradient, initialized using an array of Taylor-Green vortices, extending the Pr=1 simulations performed in [Riley and de Bruyn Kops (2003)](https://doi.org/10.1063/1.1578077). The initial Prandtl, Froude, and Reynolds numbers are (Pr, Fr, Re) = (50, 4, 3200). A total of 1,680 snapshots are recorded at uniform time intervals, each with a spatial resolution of 3584x3584x1792 grid points. Four flow variables are associated with each snapshot: the three velocity components (u,v,w) and the perturbed density field (rho) away from the background gradient. All fields are stored in binary format (32-bit little-endian), each with a size of 85.8 GB, yielding a total dataset size of 577 TB. Further details are referenced in the attached README file, and a current list of publications and associated analysis tools are provided at https://stratified-turbulence.github.io/web/.

42 ENGINEERING↗

SST-TG-P7F4R3200: Decaying Stably-Stratified Turbulence (SST), Initialized Using Taylor-Green Vortices (TG) at Prandtl Number Pr=7, Froude Number Fr=4, Reynolds Number Re=3200

This dataset comprises direct numerical simulations (DNS) of decaying stably-stratified turbulence influenced by a linear background density gradient, initialized using an array of Taylor-Green vortices, extending the Pr=1 simulations performed in [Riley and de Bruyn Kops (2003)](https://doi.org/10.1063/1.1578077). The initial Prandtl, Froude, and Reynolds numbers are (Pr, Fr, Re) = (7, 4, 3200). A total of 15,250 snapshots are recorded at uniform time intervals, each with a spatial resolution of 1280x1280x640 grid points. Four flow variables are associated with each snapshot: the three velocity components (u,v,w) and the perturbed density field (rho) away from the background gradient. All fields are stored in binary format (32-bit little-endian), each with a size of 4 GB, yielding a total dataset size of 244 TB. Further details are referenced in the attached README file, and a current list of publications and associated analysis tools are provided at https://stratified-turbulence.github.io/web/.

42 ENGINEERING↗

SU-E-T-204: Comparison of Absorbed-Dose to Water in High-Energy Photon Beams Based On Addendum AAPM TG-51, IAEA TRS-398, and JSMP 12

Purpose: Several clinical reference dosimetry protocols for absorbed-dose to water have recently been published: The American Association of Physicists in Medicine (AAPM) published an Addendum to the AAPM’s TG-51 (Addendum TG-51) in April 2014, and the Japan Society of Medical Physics (JSMP) published the Japan Society of Medical Physics 12 (JSMP12), a clinical reference dosimetry protocol, in September 2012. This investigation compared and evaluated the absorbed-dose to water of high-energy photon beams according to Addendum TG-51, International Atomic Energy Agency Technical Report Series No. 398 (TRS-398), and JSMP12. Methods: Differences in the respective beam quality conversion factors with Addendum TG-51, TRS-398, and JSMP12 were analyzed and the absorbed-dose to water using 6- and 10-MV photon beams was measured according to the protocols recommended in Addendum TG-51, TRS-398, and JSMP12. The measurements were conducted using two Farmer-type ionization chambers, Exradin A12 and PTW 30013. Results: The beam quality conversion factors for both the 6- and 10-MV photon beams with Addendum TG-51 were within 0.6%, in agreement with the beam quality conversion factors with TRS-398 and JSMP12. The Exradin A12 provided an absorbed-dose to water ratio from 1.003 to 1.006 with TRS-398 / Addendum TG-51 and from 1.004 to 1.005 with JSMP 12 / Addendum TG-51, whereas the PTW 30013 provided a ratio of 1.001 with TRS-398 / Addendum TG-51 and a range from 0.997 to 0.999 with JSMP 12 / Addendum TG-51. Conclusion: Despite differences in the beam quality conversion factor, no major differences were seen in the absorbed-dose to water with Addendum TG-51, TRS-398, and JSMP12. However, Addendum TG-51 provides the most recent data for beam quality conversion factors based on Monte Carlo simulation and greater detail for the measurement protocol. Therefore, the absorbed-dose to water measured with Addendum TG-51 is an estimate with less uncertainty.

60 APPLIED LIFE SCIENCES↗

Report of the Task Group 186 on model-based dose calculation methods in brachytherapy beyond the TG-43 formalism: Current status and recommendations for clinical implementation

The charge of Task Group 186 (TG-186) is to provide guidance for early adopters of model-based dose calculation algorithms (MBDCAs) for brachytherapy (BT) dose calculations to ensure practice uniformity. Contrary to external beam radiotherapy, heterogeneity correction algorithms have only recently been made available to the BT community. Yet, BT dose calculation accuracy is highly dependent on scatter conditions and photoelectric effect cross-sections relative to water. In specific situations, differences between the current water-based BT dose calculation formalism (TG-43) and MBDCAs can lead to differences in calculated doses exceeding a factor of 10. MBDCAs raise three major issues that are not addressed by current guidance documents: (1) MBDCA calculated doses are sensitive to the dose specification medium, resulting in energy-dependent differences between dose calculated to water in a homogeneous water geometry (TG-43), dose calculated to the local medium in the heterogeneous medium, and the intermediate scenario of dose calculated to a small volume of water in the heterogeneous medium. (2) MBDCA doses are sensitive to voxel-by-voxel interaction cross sections. Neither conventional single-energy CT nor ICRU/ICRP tissue composition compilations provide useful guidance for the task of assigning interaction cross sections to each voxel. (3) Since each patient-source-applicator combination is unique, having reference data for each possible combination to benchmark MBDCAs is an impractical strategy. Hence, a new commissioning process is required. TG-186 addresses in detail the above issues through the literature review and provides explicit recommendations based on the current state of knowledge. TG-43-based dose prescription and dose calculation remain in effect, with MBDCA dose reporting performed in parallel when available. In using MBDCAs, it is recommended that the radiation transport should be performed in the heterogeneous medium and, at minimum, the dose to the local medium be reported along with the TG-43 calculated doses. Assignments of voxel-by-voxel cross sections represent a particular challenge. Electron density information is readily extracted from CT imaging, but cannot be used to distinguish between different materials having the same density. Therefore, a recommendation is made to use a number of standardized materials to maintain uniformity across institutions. Sensitivity analysis shows that this recommendation offers increased accuracy over TG-43. MBDCA commissioning will share commonalities with current TG-43-based systems, but in addition there will be algorithm-specific tasks. Two levels of commissioning are recommended: reproducing TG-43 dose parameters and testing the advanced capabilities of MBDCAs. For validation of heterogeneity and scatter conditions, MBDCAs should mimic the 3D dose distributions from reference virtual geometries. Potential changes in BT dose prescriptions and MBDCA limitations are discussed. When data required for full MBDCA implementation are insufficient, interim recommendations are made and potential areas of research are identified. Application of TG-186 guidance should retain practice uniformity in transitioning from the TG-43 to the MBDCA approach.

61 RADIATION PROTECTION AND DOSIMETRY↗

TU-B-304-01: The Aftermath of TG-142

Although published in 2009, the AAPM TG-142 report on accelerator quality assurance still proves a challenge for full clinical implementation. The choice of methodologies to satisfy TG-142 requirements is critical to a successful application. Understanding the philosophy of TG-142 can help in creating an institution-specific QA practice that is both efficient and effective. The concept of maintaining commissioned beam profiles is still found confusing. The physicist must also consider technologies not covered by TG-142 (i.e. arc therapy techniques). On the horizon is TG-198 report on implementing TG-142. Although the community still lacks a final TG-100 report, performing a failure-mode -and-effects analysis and statistical process control analysis to determine the institution-specific clinical impact of each TG-142 test may be useful for identifying trends for pro-active surveillance. Learning Objectives: To better understand the confusing and controversial aspects of TG-142. To understand what is still missing from TG-142 and how to account for these tests in clinical practice To describe which QA tests in TG-142 yield the largest potential clinical result if not discovered.

60 APPLIED LIFE SCIENCES↗

TU-B-304-02: Quantitative FMEA of TG-142

Although published in 2009, the AAPM TG-142 report on accelerator quality assurance still proves a challenge for full clinical implementation. The choice of methodologies to satisfy TG-142 requirements is critical to a successful application. Understanding the philosophy of TG-142 can help in creating an institution-specific QA practice that is both efficient and effective. The concept of maintaining commissioned beam profiles is still found confusing. The physicist must also consider technologies not covered by TG-142 (i.e. arc therapy techniques). On the horizon is TG-198 report on implementing TG-142. Although the community still lacks a final TG-100 report, performing a failure-mode -and-effects analysis and statistical process control analysis to determine the institution-specific clinical impact of each TG-142 test may be useful for identifying trends for pro-active surveillance. Learning Objectives: To better understand the confusing and controversial aspects of TG-142. To understand what is still missing from TG-142 and how to account for these tests in clinical practice To describe which QA tests in TG-142 yield the largest potential clinical result if not discovered.

60 APPLIED LIFE SCIENCES↗

TU-B-304-00: The Aftermath of TG-142

Although published in 2009, the AAPM TG-142 report on accelerator quality assurance still proves a challenge for full clinical implementation. The choice of methodologies to satisfy TG-142 requirements is critical to a successful application. Understanding the philosophy of TG-142 can help in creating an institution-specific QA practice that is both efficient and effective. The concept of maintaining commissioned beam profiles is still found confusing. The physicist must also consider technologies not covered by TG-142 (i.e. arc therapy techniques). On the horizon is TG-198 report on implementing TG-142. Although the community still lacks a final TG-100 report, performing a failure-mode -and-effects analysis and statistical process control analysis to determine the institution-specific clinical impact of each TG-142 test may be useful for identifying trends for pro-active surveillance. Learning Objectives: To better understand the confusing and controversial aspects of TG-142. To understand what is still missing from TG-142 and how to account for these tests in clinical practice To describe which QA tests in TG-142 yield the largest potential clinical result if not discovered.

60 APPLIED LIFE SCIENCES↗

WE-PIS-Exhibit Hall-01: Tools for TG-142 Linac Imaging QA II

Partners in Solutions is an exciting new program in which AAPM partners with our vendors to present practical “hands-on” information about the equipment and software systems that we use in our clinics. The therapy topic this year is solutions for TG-142 recommendations for linear accelerator imaging QA. Note that the sessions are being held in a special purpose room built on the Exhibit Hall Floor, to encourage further interaction with the vendors. Using DoseLab to Perform TG-142 Imaging QA The goals of this session will be to present a clinical overview of acquiring images for TG-142 Imaging QA, as well as analyzing and evaluating results using DoseLab software. DoseLab supports planar imaging QA analysis using almost any QA phantom provided by numerous vendors. General advantages and disadvantages of selecting each of these phantoms will be briefly summarized. Best practices for selecting image acquisition parameters will be presented. A demonstration of using DoseLab software to perform a series of TG-142 tests will be performed. We will disuss why DoseLab uses its own set of imaging QA formulas, and why imaging QA measurement values of the same nominal properties will vary between TG- 142 software packages. Because TG-142 does not specify baseline and tolerance values for imaging QA, the presentation will recommend performing the manufacturer's acceptance test procedure to validate the equipment is functioning correctly. Afterwards, results can be obtained using the clinic's selected set of phantoms, image acquisition parameters, and TG-142 software to set proper baseline values. This presentation will highlight the reasons why comparing imaging QA results can be trickier than comparing linear accelerator treatment results and what physicists should keep in mind when comparing imaging QA results for different machines. Physicists are often unsure of the next step when there is an issue discovered during Imaging QA. Therefore, a few common examples of imaging issues and recommended solutions will be discussed. TG-142 Imaging QA Simplified: Lessons From Diagnostic Physics Collaboration There are many commercial options for the performance of imaging quality assurance tests for the linear accelerator imaging systems as required by the AAPM TG-142 report. Imaging quality assurance testing is largely performed by the diagnostic physicist so routine performance of these tests by the practicing oncology physicist can be complicated and confusing given all of the commercially available options. This presentation focuses on the performance of imaging quality assurance testing for linear accelerators using methods similar to that of diagnostic physicists. This presentation will address the ability to perform the required testing without complicated software and explores solutions for the performance of these tests in an efficient manner while still maintaining the ability to ascertain image quality changes that may ultimately affect clinical decisions.

60 APPLIED LIFE SCIENCES↗

SU-E-T-401: Evaluation of TG-43 Dose Calculation Accuracy for SAVI-Based Accelerated Partial Breast Irradiation (APBI) Via Monte Carlo Simulations

Purpose: The current standard TG-43 dose calculation method for SAVI-based Accelerated Partial Breast Irradiation (APBI) assumes an ideal geometry of infinite homogeneous water. However, in SAVI treatments, the air cavity inside the device and the short source-to-skin distance raise concerns about the dose accuracy of the TG-43 method. This study is to evaluate TG-43 dose calculation accuracy in SAVI treatments using Monte Carlo (MC) simulations. Methods: We recalculated the dose distributions of 15 APBI patients treated with SAVI devices, including five cases with a size of 6–1, five with 8−1 and five with 10−1, using our in-house developed fast MC dose package for HDR brachytherapy (gBMC). A phase-space file was used to model the Ir-192 HDR source. For each case, the patient CT was converted into a voxelized phantom and the dwell positions and times were extracted from treatment plans for MC dose calculations. Clinically relevant dosimetric parameters of the recalculated dose were compared to those computed via the TG-43 approach. Results: A systematic overestimation of doses was found for the 15 cases in TG-43 results, with D90, V150, and V200 for PTV-eval 2.8±1.8%, 2.0±2.2%, and 1.8±3.5% higher than MC results. TG-43 also overestimated the dose to skin with the maximum dose 4.4±8.4% higher on average. The relatively large standard deviation seen in the difference of maximum skin dose is partially ascribed to the statistical uncertainty of MC simulations when computing the maximum dose. It took gBMC ∼1 minute to compute dose for a SAVI plan. Conclusion: The high efficiency of our gBMC package facilitated the studies with a relatively large number of cases. An overestimation of TG-43 doses was found when using this MC package to recompute doses in SAVI cases. Clinical utilization of TG-43 dose calculation method in this scenario should be aware of this fact.

60 APPLIED LIFE SCIENCES↗

TH-A-BRC-01: AAPM TG-135U1 QA for Robotic Radiosurgery

AAPM TG-135U1 QA for Robotic Radiosurgery - Sonja Dieterich Since the publication of AAPM TG-135 in 2011, the technology of robotic radiosurgery has rapidly developed. AAPM TG-135U1 will provide recommendations on the clinical practice for using the IRIS collimator, fiducial-less real-time motion tracking, and Monte Carlo based treatment planning. In addition, it will summarize currently available literature about uncertainties. Learning Objectives: Understand the progression of technology since the first TG publication Learn which new QA procedures should be implemented for new technologies Be familiar with updates to clinical practice guidelines AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance - Steven Goetsch Purpose: AAPM Task Group 178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance was formed in August, 2008. The Task Group has 12 medical physicists, two physicians and two consultants. Methods: A round robin dosimetry intercomparison of proposed ionization chambers, electrometer and dosimetry phantoms was conducted over a 15 month period in 2011 and 2012 (Med Phys 42, 11, Nov, 2015). The data obtained at 9 institutions (with ten different Elekta Gamma Knife units) was analyzed by the lead author using several protocols. Results: The most consistent results were obtained using the Elekta ABS 16cm diameter phantom, with the TG-51 protocol modified as recommended by Alfonso et al (Med Phys 35, 11, Nov 2008). A key white paper (Med Phys, in press) sponsored by Elekta Corporation, was used to obtain correction factors for the ionization chambers and phantoms used in this intercomparison. Consistent results were obtained for both Elekta Gamma Knife Model 4C and Gamma Knife Perfexion units as measured with each of two miniature ionization chambers. Conclusion: The full report gives clinical history and background of gamma stereotactic radiosurgery, clinical examples and history, quality assurance recommendations and outline of possible dosimetry protocols. The report will be reviewed by the AAPM Working Group on Recommendations for Radiotherapy External Beam Quality Assurance and then by the AAPM Science Council before publication in Medical Physics Survey of possible calibration protocols for calibration of Gamma Stereotactic Radiosurgery (GSR) devices Overview of modern Quality Assurance techniques for GSR AAPM TG-218 Tolerance Levels and Methodologies for IMRT Verification QA - Moyed Miften Patient-specific IMRT QA measurement is a process designed to identify discrepancies between calculated and delivered doses. Error tolerance limits are not well-defined or consistently applied across centers. The AAPM TG-218 report has been prepared to improve the understanding and consistency of this process by providing recommendations for methodologies and tolerance limits in patient-specific IMRT QA. Learning Objectives: Review measurement methods and methodologies for absolute dose verification Provide recommendations on delivery methods, data interpretation, the use of analysis routines and choice of tolerance limits for IMRT QA Sonja Dieterich has a research agreement with Sun Nuclear Inc. Steven Goetsch is a part-time consultant for Elekta.

60 APPLIED LIFE SCIENCES↗

TH-A-BRC-02: AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance

AAPM TG-135U1 QA for Robotic Radiosurgery - Sonja Dieterich Since the publication of AAPM TG-135 in 2011, the technology of robotic radiosurgery has rapidly developed. AAPM TG-135U1 will provide recommendations on the clinical practice for using the IRIS collimator, fiducial-less real-time motion tracking, and Monte Carlo based treatment planning. In addition, it will summarize currently available literature about uncertainties. Learning Objectives: Understand the progression of technology since the first TG publication Learn which new QA procedures should be implemented for new technologies Be familiar with updates to clinical practice guidelines AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance - Steven Goetsch Purpose: AAPM Task Group 178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance was formed in August, 2008. The Task Group has 12 medical physicists, two physicians and two consultants. Methods: A round robin dosimetry intercomparison of proposed ionization chambers, electrometer and dosimetry phantoms was conducted over a 15 month period in 2011 and 2012 (Med Phys 42, 11, Nov, 2015). The data obtained at 9 institutions (with ten different Elekta Gamma Knife units) was analyzed by the lead author using several protocols. Results: The most consistent results were obtained using the Elekta ABS 16cm diameter phantom, with the TG-51 protocol modified as recommended by Alfonso et al (Med Phys 35, 11, Nov 2008). A key white paper (Med Phys, in press) sponsored by Elekta Corporation, was used to obtain correction factors for the ionization chambers and phantoms used in this intercomparison. Consistent results were obtained for both Elekta Gamma Knife Model 4C and Gamma Knife Perfexion units as measured with each of two miniature ionization chambers. Conclusion: The full report gives clinical history and background of gamma stereotactic radiosurgery, clinical examples and history, quality assurance recommendations and outline of possible dosimetry protocols. The report will be reviewed by the AAPM Working Group on Recommendations for Radiotherapy External Beam Quality Assurance and then by the AAPM Science Council before publication in Medical Physics Survey of possible calibration protocols for calibration of Gamma Stereotactic Radiosurgery (GSR) devices Overview of modern Quality Assurance techniques for GSR AAPM TG-218 Tolerance Levels and Methodologies for IMRT Verification QA - Moyed Miften Patient-specific IMRT QA measurement is a process designed to identify discrepancies between calculated and delivered doses. Error tolerance limits are not well-defined or consistently applied across centers. The AAPM TG-218 report has been prepared to improve the understanding and consistency of this process by providing recommendations for methodologies and tolerance limits in patient-specific IMRT QA. Learning Objectives: Review measurement methods and methodologies for absolute dose verification Provide recommendations on delivery methods, data interpretation, the use of analysis routines and choice of tolerance limits for IMRT QA Sonja Dieterich has a research agreement with Sun Nuclear Inc. Steven Goetsch is a part-time consultant for Elekta.

60 APPLIED LIFE SCIENCES↗

SU-E-J-110: TG 51 Dosimetry : With Or Without Lead

TG-51 Dosimetry: With or Without Lead. Purpose: In this project, an analytical method has been introduced for adjustment of the TG-51 recommended KQ in order to produce accurate dosimetric data for high energy photons without the lead foil. Methods: These investigations were performed using a 30 cm × 30 cm × 30 cm CIVCO water tank, A12 EXRADIN Water proof Farmer Chamber, a Standard Imaging MAX 4000 electrometer, and 1 mm thick lead foil from Standard Imaging. Complete TG-51 was performed every month with and without lead. The results were analyzed and an analytical model has been developed for comparing the values of KQ. TG-51 Table I was used to obtain KQ values. Results: The dosimetric evaluations were obtained for Varian Linear accelerators Model 21ix and 21ex. These results indicates that the measured data with lead foil in place as recommended by TG-51 is in excellent agreement (within 0.1%) with the calculated data obtained by the new model, from our dosimetry data without-lead. If equation 15 of the TG-51 report is used without any adjustments, it will lead to differences of about 1.6 % (on the average) in relative data which will Resultin differences of about 0.3 % (on the average) in the KQ Values. The KQ value for 18 MV obtained consistently with the equation of TG-51 “with lead” and “without lead” were 0.971 and 0.974, respectively. The 0.3 % higher results for KQ without lead eventually will lead to 0.3% larger output. However, by considering this model the KQ value was found to be 0.971 for dosimetry without lead. Conclusion: The analytical model that was introduced in this project was able to reproduce the dosimetric data of the high energy linear accelerators to within 0.1% without the use of the lead foil.

07 ISOTOPE AND RADIATION SOURCES↗