Search NASASearch

SEARCH · Search NASA

Results for “Thermal Aging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Effect of long-term thermal aging on coated Celion/LARC-160 composites

Coated and uncoated unidirectional laminates of Celion (Trademark)/LARC-160 graphite/polyimide were thermally aged in air at temperatures of 204, 260, and 316 C for various times up to 15,000 hours. Selected panels were coated with a high temperature coating resin (polyphenyl quinoxaline--PPQ): 1) edges only; 2) top and bottom only; 3)completely; or 4) not at all. Periodically during aging, panels were removed from the ovens, weighed, and short beam shear (SBS) specimens cut from selected locations in the panels. The protective coating did not influence the retention of SBS strength during thermal aging but did not lessen the amount of weight-loss incurred. The integrity of the PPQ coating was completely destroyed during aging at 316 C.

Nelson, James B.

Effects of 50,000 hours of thermal aging on graphite/epoxy and graphite/polyimide composites

Thermal effects on tensile strengths of advanced composite systems have been determined for exposure times of 100 to 50,000 hours (5.7 years). Exposures were conducted at both ambient and reduced pressures at two temperatures for each composite. At the completion of the various aging periods, specimens were removed from the specially constructed aging furnaces, visually examined, and tensile tested at elevated temperature. After tensile testing, many of the thermal aging specimens were examined using a scanning electron microscope. Results of these studies are presented, and the changes in properties and the degradation mechanisms during high-temperature aging are discussed and illustrated using metallographic techniques.

Kerr, J. R.

Effect of thermal aging on the tribological properties of polyimide films and polyimide-bonded graphite fluoride films

The effect of thermal aging on the weight loss, adherence, friction and wear of polyimide films and polyimide-bonded graphite fluoride films applied to 440C-HT stainless steel disks and to 304 stainless steel thin foils was studied. The films were exposed at temperatures of 315, 345, 370 or 400 C for 100 hours or more and then evaluated at temperatures of 25, 315 or 345 C in atmospheres of dry or moist air. Polyimide films were found to be brittle after thermal exposure; but polyimide-bonded graphite fluoride films possessed good adherence and gave low friction and wear results. Thus, polyimide-bonded graphite fluoride films appear to be good candidates for solid lubrication applications where long thermal soaks are prevalent.

Fusaro, R. L.

Effects of real-time thermal aging on graphite/polyimide composites

As part of a program to evaluate high-temperature advanced composites for use on supersonic cruise transport aircraft, two graphite/polyimide composites have been aged at elevated temperatures for times up to 5.7 years. Work on the first, HT-S/710 graphite/polyimide, was started in 1974. Evaluation of the second polyimide, Celion 6000/LARC-160, began in 1980. Baseline properties are presented, including unnotched and notched tensile data as a function of temperature, compression, flexure, shear, and constant-amplitude fatigue data at R = 0.1 and R = -1. Tensile specimens were aged in ovens where pressure and aging temperatures were controlled for various times up to and including 50,000 hours. Changes in tensile strength were determined and plotted as a function of aging time. The HT-S/710 composite aged at 450 F and 550 F if compared to the Celion 6000/LARC-160 composite aged at 350 F and 450 F. After tensile testing, many of the thermal aging specimens were examined using a scanning electron microscope. Results of these studies are presented, and changes in properties and degradation mechanisms during high-temperature aging are discussed and illustrated using metallographic techniques.

Haskins, J. F.

Surface characterization and failure analysis of thermally aged, polyimide bonded titanium

This study of high temperature stable adhesive systems using 6Al-4V titanium adherends found that certain adhesive/adherends exhibit a change from cohesive to adhesive failure mode during long term 450 F thermal aging. Lap-shear specimens which exhibited adhesive failures were subjected to failure analysis using scanning transmission electron microscopy (STEM) and surface analysis techniques. Data is presented which supports the conclusion of interfacial failures for these samples.

Peters, P. D.

Damage Assessment of Creep Tested and Thermally Aged Udimet 520 Using Acousto-Ultrasonics

Due to elevated temperatures and excessive stresses, turbine components may experience creep behavior. As a result, it is desirable to monitor and assess the current condition of such components. This study employed the Acousto-Ultrasonics (AU) method in an effort to monitor the state of the material at various percentages of used up creep life in the nickel base alloy, Udimet 520. A stepped specimen (i.e., varying cross sectional area) was employed which allowed for a postmortem nondestructive evaluation (NDE) analysis of the various levels of used up life. The overall objectives here were two fold: First, a user friendly, graphical interface AU system was developed, and second the new AU system was applied as an NDE tool to assess distributed damage resulting from creep. The experimental results demonstrated that the AU method shows promise as an NDE tool capable of detecting material changes as a function of used up creep life. Furthermore, the changes in the AU parameters were mainly attributed to the case of combined load and elevated temperature (i.e., creep) and not simply because of a timed exposure at elevated temperature (i.e., heat treatment or thermal aging).

Gyekenyesi, Andrew L.

Long-term thermal aging of Celion/V378A composite materials

Celion 6000/V378A graphite/bismaleimide composite materials were aged in air at temperatures of 177, 204, 232 and 260 deg C for various times up to 15,000 hours. Three unidirectional specimen types were aged: short beam shear (SBS), flexure, and 153 mm square panels. Aged specimens of V378A laminates exhibited excellent thermal stability. Extensive cracking was observed during aging on the 0 deg edges of the unidirectional laminates. These cracks penetrated as deep as 12 mm from the edge. The cracking appeared to have little or no effect on the observed properties of the laminates. The study indicates that the useful life of unrestrained unidirectional graphite/V378A laminates is 10,000 hours or greater at 177 C to 232 C and 2,000 to 2,000 hour at 260 C.

Nelson, J. B.

Comparison of the weight loss and adherence of nine different polyimide films thermally aged at 315 C and 350 C in air

Thermal exposure experiments at 315 and 350 C were performed in air on nine different types of polyimides applied to thin 304 stainless steel foils. The tests were conducted to determine which polyimide was the most thermally stable and adherent when subjected to long exposure times at elevated temperatures. One polyimide designated PIC-7 was found to be more thermally stable than the others; however, it did not possess the adherent properties of PIC-2 and PIC-5. It was concluded that as far as thermal stability and adherence are concerned, five of the polyimides are more suitable for high temperature applications than the other four.

Fusaro, R. L.

Thermal aging of graphite/polyimide composites

Celion 6000/PMR-15, Celion 6000/LARC-160, and Celion 6000/RK-99 graphite/polyimides were aged in circulating air ovens at temperatures of 202, 232, 260, and 288 C for various times, up to 15,000 h. Three unidirectional specimens were studied: short-beam-shear (SBS), flexure, and 153-mm square panels. The interior region of the square panels exhibited little or no property degradation. Based on the individually aged SBS specimen results, the relative thermal-oxidative stability from highest to lowest is as follows: PMR-15, LARC-160, RK-99, Celion 6000/PMR-15 and Celion 6000/LARC-160 laminates retained at least 80 percent of their initial flexural strengths for the duration of aging at each temperature. Celion 6000/RK-99 laminates exhibited a 20 to 50 percent loss of flexural strength at all aging temperatures. All three graphite/polyimide laminate materials degraded preferentially at the specimen edge perpendicular to the fibers.

Nelson, J. B.

Effect of thermal aging on the tribological properties of polyimide films and polyimide-bonded graphite fluoride films

Weight loss, adherence, friction and wear of polyimide films and polyimide-bonded graphite fluoride films applied to stainless steel disks and to 304 stainless steel thin foils were studied. The films were exposed at temperatures of 315 D, 345 D, 370 D, or 400 C for 100 hours or more and then evaluated at temperatures of 25 D, 315 D, or 345 C in atmospheres of dry or moist air. Polyimide films were found to be brittle after thermal exposure; but polyimide-bonded graphite fluoride possessed good adherence and gave low friction and wear results. Polyimide-bonded graphite fluoride films appear to be good candidates for solid lubrication applications where long thermal soaks are prevalent.

Fusaro, R. L.

Edge crack growth of thermally aged graphite/polyimide composites

Laminates of Celion 6000/LARC-160 and Celion 6000/PMR-15 graphite/polyimide composite materials were aged in air at temperatures of 202, 232, 260 and 288 C for various times up to 15,000 hours. Three unidirectional specimen types were studied: short beam shear (SBS), flexure, and 153 mm square panels. The interior region of the square panels exhibited little or no property degradation, whereas both laminate materials degraded and cracked preferentially at the specimen edge perpendicular to the fibers. Using a dye penetrant, the specimens were X-rayed and the crack depth measured as a function of time and temperature. A time temperature superposition of the crack data was successfully performed using an Arrhenius form for the shift factor. A direct correlation was found for edge crack depth and SBS strength for the LARC-160 laminates but the correlation for PMR-15 laminates was more complex.

Nelson, J. B.

Long-term thermal aging of 2 graphite-polyimide composite materials

Two graphite/polyimide composite materials were aged in circulating air ovens at temperatures 204 C, 232 C, 260 C, and 288 C for various times up to 25000 hours. The composites were: (1) Celanese Celion 6000 graphite fiber and PMR-15 polyimide resin (Celion/PMR-15) and (2) Celion 6000 graphite fiber and LARC-160 polyimide resin (Celion/LARC-160). Three unidirectional specimen geometries were studied: short beam shear (SBS) specimens, flexure specimens, and 153 mm square panels. The interior regions of the square panels exhibited only minor property degradation. The individually aged SBS and flexure specimens exhibited large reductions in strengths after aging. Both laminate materials cracked and degraded preferentially at the specimen edge perpendicular to the fibers.

Nelson, J. B.

Thermal aging effects in refractory metal alloys

The alloys of niobium and tantalum are attractive from a strength and compatibility viewpoint for high operating temperatures required in materials for fuel cladding, liquid metal transfer, and heat pipe applications in space power systems that will supply from 100 kWe to multi-megawatts for advanced space systems. To meet the system requirements, operating temperatures ranging from 1100 to 1600 K have been proposed. Expected lives of these space power systems are from 7 to 10 yr. A program is conducted at NASA Lewis to determine the effects of long-term, high-temperature exposure on the microstructural stability of several commercial tantalum and niobium alloys. Variables studied in the investigation include alloy composition, pre-age annealing temperature, aging time, temperature, and environment (lithium or vacuum), welding, and hydrogen doping. Alloys are investigated by means of cryogenic bend tests and tensile tests. Results show that the combination of tungsten and hafnium or zirconium found in commercial alloys such as T-111 and Cb-752 can lead to aging embrittlement and increased susceptibility to hydrogen embrittlement of ternary and more complex alloys. Modification of alloy composition helps to eliminate the embrittlement problem.

Stephens, J. R.

Thermal aging effects in refractory metal alloys

The alloys of niobium and tantalum are attractive from a strength and compatibility viewpoint for high operating temperatures required in materials for fuel cladding, liquid metal transfer, and heat pipe applications in space power systems that will supply from 100 kWe to multi-megawatts for advanced space systems. To meet the system requirements, operating temperatures ranging from 1100 to 1600 K have been proposed. Expected lives of these space power systems are from 7 to 10 yr. A program is conducted at NASA Lewis to determine the effects of long-term, high-temperature exposure on the microstructural stability of several commercial tantalum and niobium alloys. Variables studied in the investigation include alloy composition, pre-age annealing temperature, aging time, temperature, and environment (lithium or vacuum), welding, and hydrogen doping. Alloys are investigated by means of cryogenic bend tests and tensile tests. Results show that the combination of tungsten and hafnium or zirconium found in commercial alloys such as T-111 and Cb-752 can lead to aging embrittlement and increased susceptibility to hydrogen embrittlement of ternary and more complex alloys. Modification of alloy composition helps to eliminate the embrittlement problem.

Stephens, Joseph R.

Effect of geometry on thermal aging behavior of Celion/LARC-160 composites

Laminates of Celion/LARC-160, fabricated in thicknesses from 4 to 16 ply and in unidirectional, x-ply and fabric ply configurations, were isothermally aged at temperatures of 204, 260 and 316 C for periods up to 15,000 hours. Weight-loss of the test panels was measured at selected intervals during aging. At the lower aging temperatures, it was observed that panel thickness and ply arrangement influenced the apparent stability: i.e., thicker panels degraded less than thin panels and unidirectional panels degraded less than x-ply or fabric reinforced panels. At higher aging temperatures, all panel configurations and thicknesses converged toward the same behavior.

Nelson, James B.

Penetration of carbon-fabric-reinforced composites by edge cracks during thermal aging

Thermo-oxidative stability (TOS) test results are significantly influenced by the formation and growth or presence of interlaminar and interlaminar cracks in the cut edges of all carbon-fiber-crosslinked high-temperature polymer matrix composites(exp 1-5) (i.e., unidirectional, crossplied, angle-plied, and fabric composites). The thermo-oxidative degradation of these composites is heavily dependent on the surface area that is exposed to the harmful environment and on the surface-to-volume ratio of the structure under study. Since the growth of cracks and voids on the composite surfaces significantly increases the exposed surface areas, it is imperative that the interaction between the aging process and the formation of new surface area as the aging time progresses be understood.

Bowles, Kenneth J.

The Effects of Fiber Surface Modification and Thermal Aging on Composite Toughness and Its Measurement

A detailed experimental study was conducted to establish the structure-property relationships between elevated temperature aging and fiber-matrix bonding, Mode 2 interlaminar fracture toughness, and failure modes of carbon fiber/PMR-15 composites. The fiber-matrix adhesion was varied by using carbon fibers with different surface treatments. Short beam shear tests were used to quantify the interfacial shear strength afforded by the use of the different fiber surface treatments. The results of the short beam shear tests showed that, for times up to 1000 hr, the aging process caused no changes in the bulk of the three composite materials that would degrade the shear properties of the material. Comparisons between the interlaminar shear strengths (ILSS) measured by the short beam shear tests and the GIIC test results, as measured by the ENF test, indicated that the differences in the surface treatments significantly affected the fracture properties while the effect of the aging process was probably limited to changes at the starter crack tip. The fracture properties changed due to a shift in the fracture from an interfacial failure to a failure within the matrix when the fiber was changed from AU-4 to AS-4 or AS-4G. There appears to be an effect of the fiber/matrix bonding on the thermo-oxidative stability of the composites that were tested. The low bonding afforded by the AU 1 fiber resulted in weight losses about twice those experienced by the AS 1 reinforced composites, the ones with the best TOS.

Bowles, Kenneth J.