Meshed Lunar Terrain Thermal Model Building Short Course
Explore the source record for details and available documents.
FIND YOUR NEXT DISCOVERY
Original records, connected by a shared subject.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Lithium-ion batteries are thermo-electrochemical devices, whereby nearly every facet of their functionality and performance are thermally driven. As a result, it is important to have thermal modeling techniques that effectively capture the intricacies of both the electrochemical nature of the battery and also the complex thermal network that typically results from the design of the battery thermal management system. Here we present a thermal modeling workflow and a set of general assumptions for how to construct a thermal model of a Li-ion battery pack. We use a 14-cell bank of 18650-format Li-ion cells, loosely based on a proposed alternative battery design for Orion, as the example. Although the workflow is performed with Thermal Desktop and related utilities, the focus of this presentation is less about software specific techniques, but rather is focused on the assumptions and conditions that should be used in a model (regardless of the tool used to build the model). Example cases and results will be presented for charge, discharge, and thermal runaway.
NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) thermal management system (TMS) relies on four loop heat pipes (LHPs) to transport electronic waste heat to the vehicle cooling radiative surface and avoid overheating. The TMS has also ten constant conductance heat pipes (CCHPs) dedicated to balance the thermal load within the internal environment where the avionics boxes are mounted, also called warm electronic box (WEB), and to transport the heat from two of the science payload instruments. The TMS also uses two thermal straps to thermally link the batteries to the WEB. These thermal components, in addition to heaters, thermostat, multi-layer insulation (MLIs), and isolators forms the core of the VIPER TMS. The complex heat transport balance managed by the TMS is challenging to characterize and model. The more fidelity and granularity of a model, the more costly the computational resources needed and the longer the simulation and modeling time. When the priority is to provide quick but reliable assessments of the thermal performance or real time thermal feedback for training of console operators, simplified modeling tools are needed. To satisfy that need, this paper describes the effort to develop and correlate a model of VIPER TMS based on control volume approach. The correlation effort in particular focuses on hibernation, cold thermal balance, and hot thermal balance data from the integrated vehicle thermal vacuum (TVAC) test. Thus, the correlated model captures the heat leaks during hibernations and the performance at two extremes, bounding, operating scenarios.
The National Aeronautics and Space Administration (NASA) Artemis program plans to send astronauts to the lunar south pole, a region of the moon that is colder than previous lunar missions and low earth orbit operations. The spacesuit boots that will be used on these missions will be directly impacted by these extremely cold temperatures (down to ~50 K). To assess the performance of the Exploration Extravehicular Mobility Unit (xEMU) lunar boot in these extreme temperatures, the boot was tested at the Jet Propulsion Lab (JPL) in the Cryogenic Ice Transfer, Acquisition Development, and Excavation Laboratory (CITADEL) thermal vacuum (TVAC) chamber. This data was used to correlate thermal models to predict operational performance of the boots on the lunar south pole. This paper documents the data analysis, thermal boot model correlation, and operational predictions conducted using data from the xEMU TVAC test. Data from the test series was used to determine expected thermal conductances within the boot and between the boot and environment. These conductances were used to correlate a Thermal Desktop model of the xEMU boot across 10 different test points which varied external temperature, internal boot ventilation flowrate, and contact pressure. The correlated model was then used to predict operational performance in the lunar south pole. While the predictions indicate promising evidence for performance of the boots at the 100K test point, there is still substantial uncertainty in performance, particularly at the 48K test point. The results of this test series and model correlation stress the importance of improved testing for characterizing the expected thermal resistance between the outside of the boot and the lunar surface.
NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) uses a combination of loop heat pipes (LHPs) and heaters as the primary hardware to modulate the temperature of the electronic boxes and payloads instruments. LHPs have been designed and instrumented to be capable of passive and active shutdown. The goal of the passive shutdown, using a thermal control valve (TCV) to limit the flow of the working fluid, is to preserve thermal energy and avoid unnecessary heat leaks during lunar night. The goal of the active shutdown on the other hand, is to forcefully increase the vehicle internal temperature to bakeout the payload instruments. Several numerical modeling tools are available to analyze LHP performance under the complex set of operational requirements and environments levied on the VIPER Thermal Management System (TMS). Yet, while those numerical modeling tools are capable of detailed performance analysis, they tend to take large computational resources and long computational time. In this paper, a model of a single LHP developed based on control volume approach is presented. By using the control volume approach, the complex geometry of the LHP, and the components attached to it, are reduced to thermal lump capacitances, thus reducing the computation effort. This paper also describes the effort to correlate the proposed LHP model using thermal vacuum (TVAC) test data.
Electric aviation faces a major challenge of avoiding potentially catastrophic consequences of the battery’s thermal runaway while keeping the weight of the battery low. Detection of early warning signals of battery failures requires accurate monitoring of the battery’s health throughout its lifespan. However, identifying the parameters of the battery from field data is notoriously difficult. We investigate this problem within the framework of modeling the temperature dynamics of a Li-ion cell during tests simulating loading in electric aircraft flights. It is found that the parameters of a higher-fidelity physics-based thermal model cannot be identified from the simulated flight data. To resolve this issue, we reduce the higher-fidelity thermal model to a model with fewer parameters. The resulting reduced-order model can predict temperature dynamics accurately and is identifiable throughout the cell’s lifespan which allows using the model’s parameters to monitor the state-of-health of the aging cell and detect anomalies in thermal behavior.
Under the proposed effort in partnership with Hyundai Motor Company (HMC), the National Laboratory of the Rockies (NLR) will cooperate with HMC to develop mathematical models for battery cells and modules for simulating abuse response in batteries subject to the type of mechanical crushing that can occur in a full motor vehicle crash.
Under the proposed effort in partnership with Hyundai Motor Company (HMC), the National Renewable Energy Laboratory (NLR) will host Dr. Jaeyoung Lim from HMC for a period of one year to jointly develop mathematical models for battery cells and modules subject to mechanical crush. NLR will assist with the development of mathematical models that Dr. Lim will incorporate into his research effort on new concepts of mobility with electric vehicles.
This material will be presented at the Interagency Advanced Power Group (IAPG) Chemical Working Group and Safety Panel Meeting. IAPG serves as the premier organization coordinating the collaboration and information exchange of advanced power research and development within the U.S. government.
Explore the source record for details and available documents.
The mARC II is a 30 kW arc-jet facility at NASA Ames Research Center used to generate high-enthalpy flows for low-cost thermal protection system (TPS) technology development. Sustained operation of downstream instrumentation and material samples is constrained by thermal loading transmitted through the arc-jet test environment, limiting achievable run times and experimental throughput. This work presents the design, integration, and validation of a cooling sleeve implemented on the sweep arm drive motor feedthrough to mitigate thermal accumulation during testing. The addition of the cooling sleeve is a simple, robust upgrade that translates directly into enhanced facility capability by supporting longer run durations, reduced turnaround time, and higher throughput.
Aviation fuels offer substantial heat-sink capability that can be applied to aircraft thermal-management strategies and advanced propulsion-system concepts. Accurate control of fuel temperature is critical for understanding combustion behavior and supporting high temperature fuel experimental studies. This work describes the modeling and experimental validation of a portable, high temperature fuel-conditioning system designed for multiple NASA Glenn Research Center’s combustion facilities. The system utilizes a circulating-oil heating unit and modular tube-in-tube heat exchangers capable of conditioning Jet-A to temperatures approaching 600 K. A Thermal Desktop model was created to analyze heat exchanger configurations and predict performance across a range of operating conditions. Model predictions were compared with measurements collected in the CE-13C test facility, showing good agreement across the tested flow range except at low fuel flow rate around 2 kg/hr. Results provide guidance for sizing future fuel heating system for combustion research applications.