Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thermal Neutron Spectrum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Ab initio generation of thermal neutron scattering law for uranium dioxide

Neutronic analysis of moderated nuclear fission systems, e.g. nuclear reactors, relies upon an accurate prediction of the thermal neutron spectrum. Thermal neutrons have wavelengths on the order of the interatomic spacing between atoms in matter. Consequently, the scattering cross-sections of these neutrons are affected by the scattering law of the material (i.e. S(α,β), where α and β are dimensionless momentum and energy transfer variables), which describes the atomic structure and thermodynamic motion of the atomic nuclei. Uranium-dioxide (UO{sub 2}) is the primary fuel source for nuclear power reactors moderated by light water. In such systems (e.g. nuclear power reactors, spent fuel pools, etc.) the nuclear fuel comprises a large fraction of the system volume, approximately 1/3 in light-water reactors. Therefore, the scattering law of the fuel material may impact the thermal neutron spectrum and criticality of these systems. In this work previously established ab initio lattice dynamics (AILD) methods were utilized to calculate the phonon density of states (DOS), which acts as a fundamental input to the scattering law. Subsequently, the S(α,β) of UO{sub 2} was generated for publication as an ENDF thermal scattering library (TSL), which will be available for use in standard neutronics computer applications. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

A Workflow to Optimize Fast Neutron Irradiation in A Thermal Neutron Spectrum Test Reactor Leveraging Open-Source Tools

The Advanced Test Reactor (ATR) located at Idaho National Laboratory (INL) is one of the key nuclear engineering research and testing facilities within the US Department of Energy (DOE). The ATR is one of few high-power research reactors in the world with different application including accelerated testing of nuclear fuel, materials irradiation in a very high neutron flux environment, and medical radioisotope production [1]. Also, the ATR offers opportunities for testing fast spectrum fission and fusion reactor materials. The key challenges in this area are in further detailing and optimizing a fast spectrum environment within a thermal test reactor. This challenge involves researching, developing, and testing novel concepts for the multiplying of neutron populations into ever higher energy spectra in high flux test reactors like ATR. The main objective of this work is to investigate candidate materials for establishing a fast neutron experiment irradiation in thermal neutron spectrum test reactors which can be accomplished by filtering thermal and epithermal neutrons and boosting fast neutrons at designated irradiation positions. However, adding these filters will render the neutron spectrum and the criticality of the system. The selection of the thickness and material layers should be accomplished by developing an optimization design algorithm that is applicable for ATR to enhance the fast neutron spectrum irradiation utilizing high-fidelity Monte Carlo methods along with advanced machine learning capabilities. This paper presents workflow for design optimization to enhance fast neutron irradiation in the ATR. The workflow leverages open-source tools to develop an algorithm that is viable to ATR and can be leveraged in other reactors. The following sections discuss the development of the experiment design optimization workflow and its application to ATR irradiation positions.

42 - ENGINEERING↗

Air oxidation of yttrium hydride as a high temperature moderator for thermal neutron spectrum fission reactors

Yttrium hydride (YH x ) is an attractive moderator material for thermal neutron spectrum fission reactors requiring a small reactor core volume and has been selected as the neutron moderator for the Transformational Challenge Reactor (TCR), an advanced gas-cooled microreactor. Before YH x can be used in this application, it is important to understand the material response to off-normal conditions. In the present study, 550–650 °C isothermal dry air oxidation was performed to simulate a depressurized loss of force circulation (DLOFC) event. The oxidation was performed using thermogravimetric analysis (TGA) on bulk crack-free YHx coupons. Oxidation studies were also performed on Y coupons to elucidate the impact of H on oxidation. Both the chemistry and distribution of processing impurities were found to strongly affect oxidization behavior on a batch-to-batch basis. Regardless of batch, YHx oxidized at a significantly lower rate than Y at all temperatures, and the lower rate was directly correlated with increased hydride content. Metallic Y exhibited complex exponential kinetics, whereas YH x also exhibited complex kinetics but gained considerably less mass. According to literature reports on protonic and native-ion conductivities of Y 2 O 3 and mass spectrometry analysis of gaseous reaction products formed during the oxidation of YH x , a mechanism for the reduced oxidation rate of yttrium hydride is suggested.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Study of the Thermal Neutron Spectrum of the W-Be Photoneutron Source of the INR RAS

The possibility of reconstructing the neutron flux density of a W-Be photoneutron source using neutron activation analysis of Ag, Mn, Fe, Mn, and Ti samples is considered. The use of simple functions as AE{sup –B}, describing particular regions of the spectrum, as a reconstruction option is discussed. The dependence of the deviation of the measured reaction rates on those calculated in this study on the parameters of approximating functions is investigated. The convergence of the reconstruction results is obtained by increasing the amount of experimental data. This reconstruction method can be used for the operational measurement of the thermal neutron flux density of the photoneutron source and for the optimization of the source parameters.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A317_Fast and Thermal Neutron Spectrum Dosimetry Measurements in the Advanced Test Reactor large-B and small-I Positions Following the Sixth Core Internals Change-out

The Advanced Test Reactor (ATR) has a wide variety of irradiation positions that have had experiments that were developed by users from around the world. Most experiment irradiations rely on thoroughly benchmarked numerical models. However, some irradiation positions in ATR are not as well- characterized and are complicated by spectral perturbations from control cylinder orientation. The “small I” and “large-B” irradiation positions are located nearby control cylinders and suffer from these flux perturbations from control cylinder orientations that change during an irradiation cycle to maintain the desired core power distribution. Models predicted that these types of position would exhibit both spectral shifts and amplitude changes in neutron flux, but few measurements have been conducted to benchmark these predictions. Recently, requalification testing was performed to confirm the operational readiness of the ATR following the completion of the Core Internals Change-out (CIC). These tests provided a unique opportunity to validate the analytical methods used to simulate the ATR because nearly all components in the reactor were in a clean as-built state, significantly reducing modelling uncertainties. One subset of the testing included characterization of the fast and thermal neutron flux in the “small-I” and “large-B” positions using silver, cobalt, and nickel neutron dosimetry. In contrast to typical irradiation cycles, the control cylinders were held in position during the post-CIC nuclear testing. The specific activity of these dosimeter wires was measured following two low-power tests with different control cylinder positions.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Fast and Thermal Neutron Spectrum Dosimetry Measurements in the Advanced Test Reactor large-B and small-I Positions Following the Sixth Core Internals Change-out [Slides]

The Advanced Test Reactor (ATR) has a wide variety of irradiation positions that have had experiments that were developed by users from around the world. Most experiment irradiations rely on thoroughly benchmarked numerical models. However, some irradiation positions in ATR are not as well- characterized and are complicated by spectral perturbations from control cylinder orientation. The “small I” and “large-B” irradiation positions are located nearby control cylinders and suffer from these flux perturbations from control cylinder orientations that change during an irradiation cycle to maintain the desired core power distribution. Models predicted that these types of position would exhibit both spectral shifts and amplitude changes in neutron flux, but few measurements have been conducted to benchmark these predictions. Recently, requalification testing was performed to confirm the operational readiness of the ATR following the completion of the Core Internals Change-out (CIC). These tests provided a unique opportunity to validate the analytical methods used to simulate the ATR because nearly all components in the reactor were in a clean as-built state, significantly reducing modelling uncertainties. One subset of the testing included characterization of the fast and thermal neutron flux in the “small-I” and “large-B” positions using silver, cobalt, and nickel neutron dosimetry. In contrast to typical irradiation cycles, the control cylinders were held in position during the post-CIC nuclear testing. The specific activity of these dosimeter wires was measured following two low-power tests with different control cylinder positions.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Nondestructive and destructive assay for forensics characterization of weapons-grade plutonium produced in LEU irradiated in a thermal neutron spectrum

A post-irradiation examination (PIE) of an enriched uranium sample was performed to advance a nuclear forensics methodology, based on intra-elemental nuclide ratios. The PIE was carried out on a few milligrams of low enriched uranium dioxide (LEUO 2 ) sample, irradiated to a burnup of 1 GWd/MTU. The PIE of the LEUO 2 sample provided the concentration of selected plutonium and fission product nuclides ( 239 Pu, 240 Pu, 241 Pu, 91 Y, 95 Zr, 95 Nb, 103 Ru, 133 Cs, 134 Cs, 135 Cs, 137 Cs, 136 Ba, 138 Ba, 140 Ba, 140 La, 141 Ce, 144 Ce, 149 Sm, 150 Sm, 152 Sm, 153 Eu, and 154 Eu). The PIE supported validation of the MCNP (Monte Carlo N-Particle neutronics simulation code) predicted concentration of these nuclides in the irradiated LEUO 2 sample. This study showed that most of the MCNP predicted nuclide concentrations were within 15% and several within 10% compared to the PIE results. Furthermore, gamma and mass spectrometry of nuclides in irradiated LEUO 2 enabled the determination of uranium burnup and time since irradiation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Spectral Performance of a Composite Single-Crystal Filtered Thermal Neutron Beam for BNCT Research at the University of Missouri

Parameter studies, design calculations and initial neutronic performance measurements have been completed for a new thermal neutron beamline to be used for neutron capture therapy cell and small-animal radiobiology studies at the University of Missouri Research Reactor. The beamline features the use of single-crystal silicon and bismuth sections for neutron filtering and for reduction of incident gamma radiation. The calculated and measured thermal neutron fluxes produced at the irradiation location are 9.6x108 and 8.8x108 neutrons/cm2-s, respectively. Calculated and measured cadmium ratios (Au foils) are 217 and 132. These results indicate a well-thermalized neutron spectrum with sufficient thermal neutron flux for a variety of small animal BNCT studies.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Results from Oregon State University 1 MW TRIGA reactor irradiation of uranium-238

We are studying short-lived fission product yields to improve the nuclear databases currently available to the nuclear physics community. There are three general energy groups that are cited in the nuclear databases; thermal neutron spectrum, fission neutron spectrum and mono-energetic 14 MeV. Each neutron energy spectrum produces different fission fragment distributions. The differences between thermal and fission neutron spectrum is several MeV of energy. Thermal represents neutron energies arounds 0.026 eV. Fission neutron spectrum refers to a Watt fission neutron spectrum with a mean energy of approximately 1 MeV. 14 MeV is the result mono-energetic with a small spread in energies (~0.1-0.3 MeV) usually.

42 ENGINEERING↗

Evaluating the 239 Pu prompt fission neutron spectrum induced by thermal to 30 MeV neutrons

We present a new evaluation of the 239 Pu prompt fission neutron spectrum (PFNS) induced by thermal to 30 MeV neutrons. Compared to the ENDF/B-VII.1 evaluation, this one includes recently published experimental data as well as an improved and extended model description to predict PFNS. For instance, the pre-equilibrium neutron emission component to the PFNS is considered and the incident energy dependence of model parameters is parametrized more realistically. Experimental and model parameter uncertainties and covariances are estimated in detail. Also, evaluated covariances are provided between all PFNS at different incident neutron energies. In conclusion, selected evaluation results and first benchmark calculations using this evaluation are briefly discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fission Product Data Measured at Los Alamos for Fission Spectrum and Thermal Neutrons on {sup 239}Pu, {sup 235}U, {sup 238}U

We describe measurements of fission product data at Los Alamos that are important for determining the number of fissions that have occurred when neutrons are incident on plutonium and uranium isotopes. The fission-spectrum measurements were made using a fission chamber designed by the National Institute for Standards and Technology (NIST) in the BIG TEN critical assembly, as part of the Inter-laboratory Liquid Metal Fast Breeder Reactor (LMFBR) Reaction Rate (ILRR) collaboration. The thermal measurements were made at Los Alamos' Omega West Reactor. A related set of measurements were made of fission-product ratios (so-called R-values) in neutron environments provided by a number of Los Alamos critical assemblies that range from having average energies causing fission of 400-600 keV (BIG TEN and the outer regions of the Flattop-25 assembly) to higher energies (1.4-1.9 MeV) in the Jezebel, and in the central regions of the Flattop-25 and Flattop-Pu, critical assemblies. From these data we determine ratios of fission product yields in different fuel and neutron environments (Q-values) and fission product yields in fission spectrum neutron environments for {sup 99}Mo, {sup 95}Zr, {sup 137}Cs, {sup 140}Ba, {sup 141,143}Ce, and {sup 147}Nd. Modest incident-energy dependence exists for the {sup 147}Nd fission product yield; this is discussed in the context of models for fission that include thermal and dynamical effects. The fission product data agree with measurements by Maeck and other authors using mass-spectrometry methods, and with the ILRR collaboration results that used gamma spectroscopy for quantifying fission products. We note that the measurements also contradict earlier 1950s historical Los Alamos estimates by {approx}5-7%, most likely owing to self-shielding corrections not made in the early thermal measurements. Our experimental results provide a confirmation of the England-Rider ENDF/B-VI evaluated fission-spectrum fission product yields that were carried over to the ENDF/B-VII.0 library, except for {sup 99}Mo where the present results are about 4%-relative higher for neutrons incident on {sup 239}Pu and {sup 235}U. Additionally, our results illustrate the importance of representing the incident energy dependence of fission product yields over the fast neutron energy range for high-accuracy work, for example the {sup 147}Nd from neutron reactions on plutonium. An upgrade to the ENDF library, for ENDF/B-VII.1, based on these and other data, is described in a companion paper to this work.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Preliminary conceptual design of fast neutron spectrum nuclear thermal rocket cores using monolithic uranium nitride fuel

This paper presents a few nuclear thermal rocket (NTR) reactor core preliminary conceptual designs based on the use of monolithic uranium nitride (UN) fuel plates or pins clad with tungsten (W), alloyed or unalloyed as needed. High-assay low-enriched uranium (HALEU) as well as high-enriched uranium (HEU) are considered. Nominal core thermal powers are between 300 and 1100 MW corresponding to thrusts between 66 kN and 240 kN. The estimated thrust-to-reactor-weight ratios (T/WRx) achievable with the HEU plate and pin configurations are between 3.8 and 10.9. The T/WRx achievable with the HALEU plate and pin configurations are lower, 1.9–4.0, than those achievable with HEU. It is noteworthy that even a relatively modest increase in fuel enrichment above the HALEU limit enables a significant increase in T/WRx. It must be emphasized that these results do not yet account for uncertainties and that the appropriateness of the assumed fuel thermal design limits for normal operation (i.e., peak centerline temperature of 3100 K) will need to be confirmed. Finally, just like for the other UN-based fuels currently considered for NTR applications (i.e., CERMET and CERCER), the proposed UN fuel systems need significant testing in prototypic conditions to confirm the appropriate performance for safe NTR applications. However, the monolithic fuel systems may have, overall, a higher technology readiness level (TRL), and, consequently, shorter fuel development and validation time may result.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Rhodium self-powered neutron detector as a suitable on-line thermal neutron flux monitor in BNCT treatments

Purpose: A rhodium self-powered neutron detector (Rh SPND) has been specifically developed by the Comision Nacional de Energia Atomica (CNEA) of Argentina to measure locally and in real time thermal neutron fluxes in patients treated with boron neutron capture therapy (BNCT). In this work, the thermal and epithermal neutron response of the Rh SPND was evaluated by studying the detector response to two different reactor spectra. In addition, during clinical trials of the BNCT Project of the CNEA, on-line neutron flux measurements using the specially designed detector were assessed. Methods: The first calibration of the detector was done with the well-thermalized neutron spectrum of the CNEA RA-3 reactor thermal column. For this purpose, the reactor spectrum was approximated by a Maxwell-Boltzmann distribution in the thermal energy range. The second calibration was done at different positions along the central axis of a water-filled cylindrical phantom, placed in the mixed thermal-epithermal neutron beam of CNEA RA-6 reactor. In this latter case, the RA-6 neutron spectrum had been well characterized by both calculation and measurement, and it presented some marked differences with the ideal spectrum considered for SPND calibrations at RA-3. In addition, the RA-6 neutron spectrum varied with depth in the water phantom and thus the percentage of the epithermal contribution to the total neutron flux changed at each measurement location. Local (one point-position) and global (several points-positions) and thermal and mixed-field thermal neutron sensitivities were determined from these measurements. Thermal neutron flux was also measured during BNCT clinical trials within the irradiation fields incident on the patients. In order to achieve this, the detector was placed on patient's skin at dosimetric reference points for each one of the fields. System stability was adequate for this kind of measurement. Results: Local mixed-field thermal neutron sensitivities and global thermal and mixed-field thermal neutron sensitivities derived from measurements performed at the RA-6 were compared and no significant differences were found. Global RA-6-based thermal neutron sensitivity showed agreement with pure thermal neutron sensitivity measurements performed in the RA-3 spectrum. Additionally, the detector response proved nearly unchanged by differences in neutron spectra from real (RA-6 BNCT beam) and ideal (considered for calibration calculations at RA-3) neutron source descriptions. The results confirm that the special design of the Rh SPND can be considered as having a pure thermal response for neutron spectra with epithermal-to-thermal flux ratios up to 12%. In addition, the linear response of the detector to thermal flux allows the use of a mixed-field thermal neutron sensitivity of 1.95 {+-} 0.05 x 10{sup -21} A n{sup -1}{center_dot}cm{sup 2}{center_dot}s. This sensitivity can be used in spectra with up to 21% epithermal-to-thermal flux ratio without significant error due to epithermal neutron and gamma induced effects. The values of the measured fluxes in clinical applications had discrepancies with calculated results that were in the range of -25% to +30%, which shows the importance of a local on-line independent measurement as part of a treatment planning quality control system. Conclusions: The usefulness of the CNEA Rh SPND for the on-line local measurement of thermal neutron flux on BNCT patients has been demonstrated based on an appropriate neutron spectra calibration and clinical applications.

07 ISOTOPE AND RADIATION SOURCES↗

Postirradiation Examination of FUTURIX-FTA metallic alloy experiments

Two different metallic nuclear fuel alloys intended for transmutation applications in fast neutron spectrum nuclear reactors have been irradiated, and their performance has been evaluated after irradiation. These alloys contained elevated levels of plutonium and other minor actinides (Am, Np) compared to historically irradiated fast reactor fuel to ascertain the impact of these isotopes on fuel performance. The irradiation of these alloys was performed at the Phénix fast reactor in France to facilitate comparisons between true fast spectrum irradiations and pseudo-fast spectrum irradiations performed at the thermal neutron spectrum Idaho National Laboratory Advanced Test Reactor. The irradiation tests were designated FUTURIX-FTA DOE1 which contained a low-fertile alloy and FUTURIX-FTA DOE2 which contained a non-fertile alloy. The DOE1 fuel was irradiated to a measured burnup of 9.5 % fissions per initial heavy metal atom (FIMA), and the DOE2 fuel was irradiated to a measured burnup of 12.7 % fissions per initial heavy metal atom. This work reports baseline Postirradiation Examination (PIE) results for DOE1 and DOE2. Fuel swelling, fission product distribution, cladding strain, fission gas release, fuel microstructure, fuel cladding chemical interaction and minor actinide transmutation were all evaluated. Cladding strain was negligible and fission gas release was 52% for DOE1 and 69% for DOE2. The exams show the 2 pins behaved very similar to EBR-II metallic fuel experience. Minor actinides seem to not affect the performance of this candidate transmutation fuel. As a result, performance data from these irradiations can be used to inform the feasibility of minor actinide transmutation in future reactor systems.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Rossi-α measurements on a system consisting of weapons grade plutonium moderated by polyethylene

A critical experiment was performed on the Planet critical assembly to provide nuclear data in a thermal neutron spectrum, in particular to provide experimental data to help validate thermal scattering laws for polyethylene. The fuel consisted of layers of weapons grade plutonium plates that were moderated and reflected by various thicknesses of high density polyethylene. Rossi-α measurements were performed on a slightly modified configuration from the configuration used for the critical measurements. The Rossi-α measurement techniques are discussed and results are presented. The neutron spectrum appears to be extremely thermal when compared to other thermal systems and the configuration will be able to validate thermal scattering law.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Preliminary Analysis of the Multisphere Neutron Spectrometer

Crews working on present-day jet aircraft are a large occupationally exposed group with a relatively high average effective dose from galactic cosmic radiation. Crews of future high-speed commercial aircraft flying at higher altitudes would be even more exposed. To help reduce the significant uncertainties in calculations of such exposures, the Atmospheric Ionizing Radiation (AIR) Project, an international collaboration of 15 laboratories, made simultaneous radiation measurements with 14 instruments on five flights of a NASA ER-2 high-altitude aircraft. The primary AIR instrument was a highly sensitive extended-energy multisphere neutron spectrometer with lead and steel shells placed within the moderators of two of its 14 detectors to enhance response at high energies. Detector responses were calculated for neutrons and charged hadrons at energies up to 100 GeV using MCNPX. Neutron spectra were unfolded from the measured count rates using the new MAXED code. We have measured the cosmic-ray neutron spectrum (thermal to greater than 10 GeV), total neutron fluence rate, and neutron effective dose and dose equivalent rates and their dependence on altitude and geomagnetic cutoff. The measured cosmic-ray neutron spectra have almost no thermal neutrons, a large "evaporation" peak near 1 MeV and a second broad peak near 100 MeV which contributes about 69% of the neutron effective dose. At high altitude, geomagnetic latitude has very little effect on the shape of the spectrum, but it is the dominant variable affecting neutron fluence rate, which was 8 times higher at the northernmost measurement location than it was at the southernmost. The shape of the spectrum varied only slightly with altitude from 21 km down to 12 km (56 - 201 grams per square centimeter atmospheric depth), but was significantly different on the ground. In all cases, ambient dose equivalent was greater than effective dose for cosmic-ray neutrons.

Goldhagen, P.↗