Results for “Thermal Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Life sciences passive GN2 freezer thermal performance test

Thermal performance tests that were conducted on the life sciences passive GN2 freezer project are summarized as well as the improvements to the freezers to improve the thermal performance of the containers. Procedures were developed, based upon these tests, to initially charge the freezers with LN2 and verify that the freezer performance is adequate for the mission duration. Improvements were made to the corvac sample tube to limit the amount of breakage due to thermal expansion of the liquid during freezing. A method of verifying the freezer vacuum insulative integrity was defined as well as a procedure for refurbishment of the internal vacuum level. Freezer modifications were made to ease the reevacuation of the containers. The orientation of the freezer in a 1-G environment, after being charged, had to remain in a vertical position. The LN2 boiloff rate increased significantly in a horizontal position. This resulted in a stowage definition in the spacecraft prior to launch. Functional testing, using the SL-1 mission timeline showed that the freezer will maintain samples in the frozen state for the duration of the mission.

Belshaw, G. W.

Space Shuttle Orbiter - Reusable surface insulation subsystem thermal performance

The thermal performance of the reusable surface insulation (RSI) subsystem consisting of silica tiles, silicone coated nylon felt insulation, and ceramic cloth gap fillers and thermal barriers is discussed. Thermal response predictions for the components are compared with measured flight data, which indicates that the RSI thermal performance can meet or exceed design requirements for the majority of the RSI. Visual inspections and the maximum temperature conditions observed in structural components after data acquisition suggest that the flight environment was not as severe as the worst case preflight prediction.

Dotts, R. L.

Economic trade-offs between the performance of collector thermal performance tests on a Solar Simulator as opposed to outdoor testing

In 1976 a large Solar Simulator was designed and installed at Marshall Space Flight Center. This Solar Simulator is the largest of its type in the country and has a 'working' area of 4 ft x 8 ft. Recently completed comparison tests show excellent correlation with data collected in the natural sun. The Solar Simulator has been in operation since September 1976 and the costs of operation are now determinable together with the cost of design and construction. The authors compare the total operational costs of obtaining test data using the simulator with analogous costs of testing in the natural sun. In addition, productivity is compared.

Reily, J. C.

Shuttle TPS thermal performance and analysis methodology

Thermal performance of the thermal protection system was approximately as predicted. The only extensive anomalies were filler bar scorching and over-predictions in the high Delta p gap heating regions of the orbiter. A technique to predict filler bar scorching has been developed that can aid in defining a solution. Improvement in high Delta p gap heating methodology is still under study. Minor anomalies were also examined for improvements in modeling techniques and prediction capabilities. These include improved definition of low Delta p gap heating, an analytical model for inner mode line convection heat transfer, better modeling of structure, and inclusion of sneak heating. The limited number of problems related to penetration items that presented themselves during orbital flight tests were resolved expeditiously, and designs were changed and proved successful within the time frame of that program.

Neuenschwander, W. E.

Thermal Testing of High Performance: Thermal Barrier Coatings for Turbine Blades

A 350 micron thick 7 wt.% Y 2 O 3 -ZrO 2 (7YSZ) ceramic Thermal Barrier Coating (TBC) was manufactured in an argon atmosphere and with a strictly controlled substrate temperature on flat IN 600 samples and on IN 100 aircraft turbine blades. This new atmosphere and temperature controlled spraying (ATCS) allows the reduction of the residual stresses and an improvement in the microstructure and in the mechanical properties of the coating. The good performance of these new TBC's was assessed in thermal fatigue and in thermal shock tests carried out in air at 1100°C and at 1280°C respectively. The oxidation rate of the metal-ceramic interface was measured at 1100°C. Failure of the TBC's was induced only by the deterioration (like oxidation, cracking, ...) of the uncoated parts of the samples, as testing temperature was too severe for the base metals. Spalling was thereafter driven by compressive stresses near the aluminum oxide layer at the metal-ceramic interface. The results of these tests underline the good quality of the ceramic coating manufactured by the new ATCS technology.

L Bertamini

Thermal performance of an integrated thermal protection system for long-term storage of cryogenic propellants in space

It was demonstrated that cryogenic propellants can be stored unvented in space long enough to accomplish a Saturn orbiter mission after 1,200-day coast. The thermal design of a hydrogen-fluorine rocket stage was carried out, and the hydrogen tank, its support structure, and thermal protection system were tested in a vacuum chamber. Heat transfer rates of approximately 23 W were measured in tests to simulate the near-Earth portion of the mission. Tests to simulate the majority of the time the vehicle would be in deep space and sun-oriented resulted in a heat transfer rate of 0.11 W.

Dewitt, R. L.

LARGO hot water system thermal performance test report

The thermal performance tests and results on the LARGO Solar Hot Water System under natural environmental conditions is presented. Some objectives of these evaluations are to determine the amount of energy collected, the amount of energy delivered to the household as contributed by solar power supplied to operate the system and auxiliary power to maintain tank temperature at proper level, overall system efficiency and to determine temperature distribution within the tank. The Solar Hot Water system is termed a Dump-type because of the draining system for freeze protection. The solar collector is a single glazed flat plate. An 82-gallon domestic water heater is provided as the energy storage vessel. Water is circulated through the collector and water heater by a 5.3 GPM capacity pump, and control of the pump motor is achieved by a differential temperature controller.

Source record

Thermal performance of gaseous-helium-purged tank-mounted multilayer insulation system during ground-hold and space-hold thermal cycling and exposure to water vapor

An experimental investigation was conducted to determine (1) the ground-hold and space-hold thermal performance of a multilayer insulation (MLI) system mounted on a spherical, liquid-hydrogen propellant tank and (2) the degradation to the space-hold thermal performance of the insulation system that resulted from both thermal cycling and exposure to moisture. The propellant tank had a diameter of 1.39 meters (4.57ft). The MLI consisted of two blankets of insulation; each blanket contained 15 double-aluminized Mylar radiation shields separated by double silk net spacers. Nineteen tests simulating basic cryogenic spacecraft thermal (environmental) conditions were conducted. These tests typically included initial helium purge, liquid-hydrogen fill and ground-hold, ascent, space-hold, and repressurization. No significant degradation of the space-hold thermal performance due to thermal cycling was noted.

Sumner, I. E.

Thermal performance of aircraft polyurethane seat cushions

Measurements were conducted on 7.6 x 7.6 cm samples of polyurethane seat cushion material in a modified National Bureau of Standards smoke density chamber to simulate real life conditions for an onboard aircraft fire or post-crash fire. In this study, a non-flaming heat radiation condition was simulated. Two aluminized polymeric fabrics (Norfab 11HT-26-A and Preox 1100-4) and one neoprene type material in two thicknesses (Vonar 2 and 3) were tested as heat blocking layers to protect the urethane foam from rapid heat degradation. Thermogravimetric analysis and differential scanning calorimetry were performed to characterize thermally the materials tested. It was found that Vonar 2 or 3 provided approximately equal thermal protection to F.R. urethane as the aluminized fabrics, but at a significant weight penalty. The efficiency of the foams to absorb heat per unit mass loss when protected with the heat blocking layer decreases in the heating range of 2.5-5.0 W/sq cm, but remains unchanged or slightly increases in the range of 5.0-7.5 W/sq cm. The results show that at all heat flux ranges tested the usage of a heat blocking layer in aircraft seats significantly improves their thermal performance.

Kourtides, D. A.

Thermal performance of a customized multilayer insulation (MLI)

The thermal performance of a LH2 tank on a shroudless vehicle was investigated. The 1.52 m (60 in) tank was insulated with 2 MLI blankets consisting of 18 double aluminized Mylar radiation shields and 19 silk net spacers. The temperature of outer space was simulated by using a cryoshroud which was maintained at near liquid hydrogen temperature. The heating effects of a payload were simulated by utilizing a thermal payload simulator (TPS) viewing the tank. The test program consisted of three major test categories: (1) null testing, (2) thermal performance testing of the tank installed MLI system, and (3) thermal testing of a customized MLI configuration. TPS surface temperatures during the null test were maintained at near hydrogen temperature and during test categories 2 and 3 at 289 K (520R). The heat flow rate through the tank installed MLI at a tank/TPS spacing of 0.457 m was 1.204 watts with no MLI on the TPS and 0.059 watts through the customized MLI with three blankets on the TPS. Reducing the tank/TPS spacing from 0.457 m to 0.152 m the heat flow through the customized MLI increased by 10 percent.

Leonhard, K. E.

Indoor test for thermal performance evaluation of Libbey-Owens-Ford solar collector

The thermal performance of a flat plate solar collector that uses liquid as the heat transfer medium was investigated under simulated conditions. The test conditions and thermal performance data obtained during the tests are presented in tabular form, as well as in graphs. Data obtained from a time constant test and incident angle modifier test, conducted to determine transient effect and the incident angle effect on the collector, are included.

Shih, K.

Space Shuttle Orbiter leading edge structural subsystem thermal performance

An extensive qualification test program and the STS-1 flight of the Space Shuttle Orbiter have provided the data necessary to verify the performance of the Orbiter thermal protection system. The reinforced carbon-carbon leading edge structural subsystem is used on areas of the orbiter where temperatures exceed 2300 F. The subsystem consists of the ROC nose cap and wing leading edge panels, metallic attachments, internal insulation, and interface tiles. Thermal response data from the qualification tests and the STS-1 flight, postflight inspection, and analytical predictions support the conclusion that the thermal performance of the subsystem verified the design.

Curry, D. M.

Thermal performance of MSFC hot air collectors under natural and simulated conditions

The procedures used and the results obtained from an evaluation test program conducted to determine the thermal performance and structural characteristics of selected MSFC--designed hot air collectors under both real and simulated environmental conditions are described. Five collectors were tested in the three phased program. A series of outdoor tests were conducted to determine stagnation temperatures on a typical bright day and to determine each collector's ability to withstand these temperatures. Two of the collectors experienced structural deformation sufficient to eliminate them from the remainder of the test program. A series of outdoor tests to evaluate the thermal performance of collector S/N 10 under certain test conditions were performed followed by a series of indoor tests to evaluate the thermal performance of the collector under closely controlled simulated conditions.

Shih, K., Sr.

Thermal Performance of Aircraft Polyurethane Seat Cushions

Aircraft seat materials were evaluated in terms of their thermal performance. The materials were evaluated using (a) thermogravimetric analysis, (b) differential scanning calorimetry, (c) a modified NBS smoke chamber to determine the rate of mass loss and (d) the NASA T-3 apparatus to determine the thermal efficiency. In this paper, the modified NBS smoke chamber will be described in detail since it provided the most conclusive results. The NBS smoke chamber was modified to measure the weight loss of material when exposed to a radiant heat source over the range of 2.5 to 7.5 W/sq cm. This chamber has been utilized to evaluate the thermal performance of various heat blocking layers utilized to protect the polyurethane cushioning foam used in aircraft seats. Various kinds of heat blocking layers were evaluated by monitoring the weight loss of miniature seat cushions when exposed to the radiant heat. The effectiveness of aluminized heat blocking systems was demonstrated when compared to conventional heat blocking layers such as neoprene. All heat blocking systems showed good fire protection capabilities when compared to the state-of-the-art, i.e., wool-nylon over polyurethane foam.

Kourtides, D. A.

Thermal performance of a mechanically attached ablator tile for on-orbit repair of shuttle TPS

The reusable surface insulation (RSI) material used in the shuttle thermal protection system is susceptible to damage. If any RSI tiles are damaged or lost during ascent, they must be repaired or replaced prior to entry. One approach to replacing a damaged or missing RSI tile consists of mechanically attaching a tile of ablation material in the place of the RSI tile. The thermal performance of this type of repair tile was evaluated in a simulated entry heating environment. The test specimen consisted of the ablator repair tile mechanically fastened to the strain isolation pad and surrounded by RSI tiles. The evaluation of the thermal performance was based on temperature response, surface integrity, and predicted flight performance. When the ablator tile protruded 1/8 inch above the surrounding RSI tiles, the forward facing steps caused significant inflow of hot gas down the ablator RSI joints and this inflow caused greatly increased back surface temperatures.

Thompkins, S. S.