Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thermal modeling and analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Primary System Thermal Fluids Analysis Model Development for the Compact High Temperature Gas Reactor (HC-HTGR) (Final Report)

Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multi-disciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed HC-HTGR and support its commercialization as a safe, low-cost HTGR. Argonne National Laboratory (Argonne) is collaborating on the thermal hydraulic design and analysis of HC-HTGR reactor pressure vessel internals to ensure the reactor maintains sufficient safety margins during normal operation, shutdown, and accident conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal Analysis Evaluations Using the Dry Cask Simulator

Different thermal analysis models were developed to simulate the dry cask simulator (DCS). The DCS is an experiment designed to simulate dry storage of a single boiling water reactor fuel assembly under a variety of heat loads and internal pressures. The DCS was set up and tested in both a vertical and horizontal configuration to determine cladding temperatures in vertical and horizontal dry cask storage systems. The models included a detailed STAR-CCM+ model with the fuel assembly geometry explicitly modeled, a porous STAR-CCM+ model with the fuel assembly geometry modeled as porous media region with calculated effective properties, and a COBRA-SFS model. COBRA-SFS is a thermal-hydraulic code developed for steady-state and transient analysis of multi assembly spent-fuel storage and transportation systems. STAR-CCM+ is a commercial computation fluid dynamics (CFD) code. Both a detailed and porous STARCCM+ model were developed to look at the effective thermal conductivity (keff) approach to modeling a fuel assembly. A keff fuel model is typically model in CFD thermal analyses due to its significantly lower computational costs. The models were run for a combination of low and high canister pressures (100 kPa and 800 kPa) and low and high internal heat loads (0.5 kW and 5 kW). Results from all three models were compared against experimental data taken from the DCS for the peak cladding temperature (PCT) and inlet air mass flow.

Suffield, Sarah R.↗

Thermal Stress Modeling and Analysis of Packed-bed Thermocline Energy Storage Tank for INL Thermal Energy Distribution System (TEDS)

The Thermal Energy Distribution System (TEDS) at Idaho National Laboratory (INL) is a thermal-hydraulic flow loop to support the integration of co-located multiple experimental systems, where a packed-bed thermal energy storage (TES) is installed as a thermal buffer and storage unit for TEDS. The packed-bed TES is adopted in TEDS because of its benefit as a low-cost single-tank storage option compared to the traditional two-tank storage. However, thermal ratcheting is one potential design concern which is caused by the rearrangement of granular filler inside a packed-bed tank during continuous thermal cycling operation of the packed-bed TES tank. If the thermally induced stress exceeds yield strength of the tank wall, it may cause catastrophic consequences like rupture of the thermal storage tank. Thus, it is crucial to understand the phenomenon to ensure the robust operation. Based on the temperature boundary conditions given by transient thermal analyses with computational fluid dynamics (CFD) simulations, the thermal ratcheting analysis is then conducted to evaluate the hoop stress and resultant thermal ratcheting potential of the TES tanks with two different modeling approaches: (1) infinite rigidity model and (2) Drucker-Prager (DP) model. The validity of each modeling method was examined by comparing the numerical simulation with the experimental data obtained from the packed-bed TES tank for Solar One Plant and evaluate the thermal ratcheting potential of the TEDS TES tank.

25 ENERGY STORAGE↗

Ambiguities in the hadro-chemical freeze-out of Au+Au collisions at SIS18 energies and how to resolve them

The thermal fit to preliminary HADES data of Au+Au collisions at $\sqrt{s_{NN}}$=2.4 GeV shows two degenerate solutions at T≈50 MeV and T≈70 MeV. The analysis of the same particle yields in a transport simulation of the UrQMD model yields the same features, i.e. two distinct temperatures for the chemical freeze-out. While both solutions yield the same number of hadrons after resonance decays, the feeddown contribution is very different for both cases. This highlights that two systems with different chemical composition can yield the same multiplicities after resonance decays. The nature of these two minima is further investigated by studying the time-dependent particle yields and extracted thermodynamic properties of the UrQMD model. It is confirmed, that the evolution of the high temperature solution resembles cooling and expansion of a hot and dense fireball. The low temperature solution displays an unphysical evolution: heating and compression of matter with a decrease of entropy. These results imply that the thermal model analysis of systems produced in low energy nuclear collisions is ambiguous but can be interpreted by taking also the time evolution and resonance contributions into account.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermal Modeling and Simulation of the Packed-bed Thermal Energy Storage Combined with INL Thermal Energy Distribution System

Dynamic Energy Transport and Integration Lab (DETAIL) at Idaho National Laboratory is to support experimental demonstration and validation research on Nuclear-Renewable Hybrid Energy System [1]. The Thermal Energy Distribution System (TEDS) is a thermal-hydraulic flow loop in DETAIL with its own dedicated control system to support the integration of co-located multiple experimental systems, where a packed-bed thermal energy storage (TES) is installed as a thermal buffer and storage unit. Among various TES options, the packed-bed TES is adopted in TEDS because it offers a low-cost single-tank thermal storage option compared to the traditional two-tank TES. However, since the TES tank is filled with granular fillers having different thermophysical properties from those of TES tank wall, there is a potential thermo-mechanical issue to be carefully addressed like thermal ratcheting which may pose a significant design concern for the packed-bed TES tank. Thermal ratcheting is a thermomechanical process caused by the repeated rearrangement of granular filler inside a TES tank during continuous thermal cycling operation of the packed-bed TES system. If the thermally induced stress exceeds the yield strength of a TES tank wall, catastrophic consequences may happen like rupture of the TES tank. Thus, it is important to understand the phenomenon to ensure the robust operation of the packed-bed TES tank. Given that thermal ratcheting is caused by complex interaction of thermal transport in the porous bed and solid mechanics, the accurate prediction of transient thermal behavior of the packed-bed TES tank, which is the focus of this paper, is critical to the reliable thermal ratcheting analysis. This paper discusses the numerical modeling, simulation, and validation studies that are ongoing at INL to investigate the transient thermal behavior of the packed-bed TES. Of particular concern is the transient thermal process occurring in the packed-bed TES unit that is operated in conjunction with the INL TEDS. The main goal of this research is three-fold: (i) provide preliminary insights into the transient thermal behavior of the TEDS TES tank, (ii) support the thermal measurement and validation plan for TEDS experiment, and (iii) provide transient thermal boundary conditions to support the reliable thermal ratcheting analysis of the TEDS TES tank. For the transient thermal modeling and analysis, a CFD model was developed, and the validity of the modeling approach was examined via comparing the numerical simulation results with the experimental data obtained from various design characteristics of packed-bed TES tanks. Then, the present modeling method was applied for the transient thermal analysis of the TEDS TES tank, and the results are discussed along with the potential improvement of data acquisition strategy for the future TEDS experiments for more precise validation study.

25 ENERGY STORAGE↗

Retrofit Energy Analysis and Central Thermal modeling (REACT) v1.0

REACT is a website designed to simplify the analysis and decision-making process for retrofitting existing central plant heating and cooling systems with advanced heat pump technologies. The tool evaluates the technical and economic viability of replacing traditional boilers with various options including water-to-water or air-to-water heat pumps, which can provide efficient and lower-cost heating and cooling. It allows users to compare current central plant configurations with retrofit scenarios, assessing energy consumption, life-cycle costs, and environmental impact. Retrofitting traditional boiler and chiller systems with water-to-water or air-to-water heat pumps can significantly reduce energy consumption and lower lifecycle costs. The REACT provides: User-Friendly Tools: A user friendly web interface for quick, intuitive analysis accessible to non-experts. Advanced Modeling: A Python-powered engine for detailed parametric studies, optimization, and research applications. Comprehensive Analysis: Lifecycle cost evaluation, energy consumption modeling, and environmental impact assessment. Visual Insights: A variety of plots to visualize system performance and design trade-offs. The engine for the website (REACT) bases on several Python libraries, and the website will be hosted on an ETA server.

Kim, Donghun [Lawrence Berkeley National Laborator↗

CODE-TO-CODE BENCHMARK STUDY FOR THERMAL STRESS MODELING AND PRELIMINARY ANALYSIS OF THE HIGH-TEMPERATURE SINGLE HEAT PIPE EXPERIMENT

Microreactors are very small nuclear reactors with typical thermal-energy output of up to 20 MWth. The microreactor concept is gaining more and more attention for safe, robust, and reliable supply of electricity for remote locations and to meet industrial process heat needs. Heat-pipe-cooled microreactor is one of the microreactors being investigated at Idaho National Laboratory. In the heat-pipe-cooled microreactor, heat pipes remove heat from the reactor core as a passive heat-transfer device, so the fluid circulation is not required for cooling, which can substantially simplify the overall reactor design. However, given the extremely high temperatures in the core region and potentially large temperature gradients across the structure materials, thermal stresses need to be well-analyzed to ensure structural integrity during normal operations and accident scenarios for the heat-pipe-cooled microreactor designs. This paper discusses finite element method-based thermal-stress analysis for the high-temperature single heat-pipe test article in the Single Primary Heat Extraction and Removal Emulator (SPHERE) facility at Idaho National Laboratory, using two commercial software packages, Abaqus and STAR-CCM+. A code-to-code benchmark study was performed to crosscheck the model setup and capability of each code and to gain insights into the potential thermal stress concerns from the current experimental setup. It is observed the significant thermal stresses happen at the locations where the largest temperature gradients appeared between heat pipe and electric heater. The temperature fields have good agreements between Abaqus and STAR-CCM+, while the induced thermal stresses show modest deviations probably due to differences of meshing engines used in these two codes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

[Presentation Slides] Code-to-Code Benchmark Study for Thermal Stress Modeling and Preliminary Analysis of the High-temperature Single Heat-Pipe Experiment

In the heat-pipe-cooled microreactor, heat pipes remove heat from the reactor core as a passive heat-transfer device, so the fluid circulation is not required for cooling, which can substantially simplify the overall reactor design. However, given the extremely high temperatures in the core region and potentially large temperature gradients across the structure materials, thermal stresses need to be well-analyzed to ensure structural integrity during normal operations and accident scenarios. This presentation slides discuss finite element method-based thermal-stress analysis for the high-temperature single heat-pipe test article in the Single Primary Heat Extraction and Removal Emulator (SPHERE) facility at Idaho National Laboratory (INL), using two commercial software packages, Abaqus and Star-CCM+. A code-to-code benchmark study was performed to crosscheck the model setup and capability of each code and to gain preliminary insights into the potential thermal stress concerns from the current experimental setup. It is observed the significant thermal stresses happen at the inner surface of the heat pipe hole surrounded by electric heaters where the largest temperature gradients appear. The temperature fields have good agreements between Abaqus and Star-CCM+, while the induced thermal stresses show modest deviations probably due to differences of meshing engines used in these two codes. It is found that the local maximum thermal stresses may reach close to the ultimate tensile strength and yield strength of structural material depending on the heater power. Ultimately, the coupled thermal-structural analysis will help guide the current experimental plan and ensure the facility safety for future experimental study.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

$\mathrm{UPDATED}$ $\mathrm{U3SI2}$ thermal creep model and sensitivity analysis of the $\mathrm{U3SI2-SIC}$ accident tolerant $\mathrm{FUEL}$

U 3 Si 2 is a candidate accident tolerant fuel (ATF) replacement for UO 2 . U 3 Si 2 ’s high uranium density and high thermal conductivity are favorable properties in steady-state and accident conditions. Low power performance of this U3Si2-SiC concept fuel is compared to that of UO 2 -Zr4 fuels by implementing models that describe the properties of U 3 Si 2 and SiC-SiC into Idaho National Laboratory's (INL) fuel performance code, BISON. Included in these material models is a thermal creep model for U 3 Si 2 based on compressive creep data. The simulated results are in keeping with community knowledge that the U 3 Si 2 -SiC concept fuel may serve as a replacement for UO 2 -Zr4 fuels during steady-state operation, provided the mSiC layer remains under compression. Through a moderate power history and three 24-month fuel cycles, the mSiC layer remains under compressive stress through a burnup of 80 MWd/kgU. During low power operation, failure of the mSiC layer generally occurs prior to significant thermal creep in U 3 Si 2 . Generally, U 3 Si 2 creep is temperature sensitive and of little importance at the temperatures and stresses simulated during steady operation and during fuel-to-cladding contact. A parameter variation study including 11,520 individual simulations with variations in nominal fuel thermal creep rate, cladding thermal conductivity, cladding irradiation creep and swelling, cladding gap size, and cladding thickness demonstrated that research priorities for this ATF should revolve around reducing cladding thickness as a means to minimize cladding failure. Generally, despite advances in SiC-SiC compliance, the brittle nature of mSiC excludes U 3 Si 2 -SiC for use where fuel cladding contact may occur.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal Analysis of a Solid Particle Light-Trapping Planar Cavity Receiver Using Computational Fluid Dynamics

Concentrated solar power (CSP) is one of the most effective ways of harnessing solar power to create efficient, durable, and resilient energy systems. This study entails thermal modeling and analysis of a novel central tower receiver configuration. This receiver uses solid particles as the heat transfer fluid (HTF), a promising option for third-generation CSP systems. The configuration considered here is the light-trapping planar cavity receiver (LTPCR) introduced by the National Renewable Energy Laboratory. While heat transfer studies of various LTPCR subsystems have been done, system-level thermal analysis of the LTPCR receiver has not been attempted. This study also presents important sensitivity analyses of the operating parameters of the CSP system, which can help guide the design of future central tower receivers. This study employs Ansys Fluent as a computational fluid dynamics (CFD) tool to model fluid dynamics and heat transfer in the receiver, intending to quantify its thermal performance. The model seamlessly integrates Monte Carlo ray tracing data, which generates absorbed solar flux profiles from the heliostat field design, with the heat transfer characteristics of the fluidized particle bed. This unified model is designed to accurately predict the thermal behavior of the LTPCR. Analysis of preliminary results reveals that the primary loss mechanisms are radiative and natural convective losses, in that order. Based on observations from a baseline case, several strategies are suggested and numerically tested. These solutions include selective cooling of high-temperature regions and manipulation of particle bed parameters. Selective cooling of high-temperature regions reduced the peak temperature by 151 degrees C and decreased thermal losses by 0.9%. Improving the particle-wall heat transfer coefficient (P-W HTC) of the particle bed decreased the thermal losses by 1.7% and decreased the peak temperatures by 57 degrees C. Decreasing the particle inlet temperature (PIT) also reduced thermal losses by 3.5% and decreased peak temperatures by 29 degrees C. Compounding these strategies improved the thermal losses of the receiver from 13.5% in the baseline case to 7.5%. Additionally, the study explores the variation in thermal performance across different locations of the receiver, where a variation of thermal losses from 12.9% to 17.3% is found. This allows a comprehensive evaluation of potential improvements in efficiency and temperature management.

computational fluid dynamics↗

Sensitivity analysis of thermal contact conductance modeling to inform MiniFuel irradiation capsule designs

The MiniFuel irradiation platform has been developed by Oak Ridge National Laboratory as a flexible, high-throughput separate effects testing capability within the High Flux Isotope Reactor (HFIR). Finite element thermal models are relied upon to design MiniFuel experiments to achieve a specific time-averaged irradiation temperature for experimental objectives. A previous study identified that uncertainty in the component heat generation rates and thermal contact conductance (TCC) model are the most significant contributors to predicted fuel temperature variance. To address both sources of uncertainty, this work performs sensitivity analysis on the TCC model to identify high-impact, high-uncertainty parameters that contribute to fuel temperature variance. The TCC model is analyzed in increasing detail, first using a standalone Python code, then again after coupling Python to the BISON fuel performance code. Furthermore, the parameters with the largest contributions to fuel temperature variance which can be reduced through design changes are identified as the initial subcapsule gas pressure, contact pressure between the fuel and dish, and the effective surface roughness of the interface. A set of design recommendations for future capsule designs has been established and applied to reduce the previously quantified average fuel temperature uncertainty ranges of ± 40 °C in the HFIR vertical experiment facilities (VXF) and ± 80 °C in the removable beryllium (RB) reflector to approximately ± 32 °C and ± 53 °C, respectively. This equates to a 21 % and 33 % reduction in the uncertainty range of the average fuel temperature for VXF and RB, respectively.

BISON↗

GPHS Module Pre-Impact test Temperature Prediction with ANSYS [PowerPoint]

The purpose of the project was to: Develop a finite element thermal model of the General Purpose Heat Source (GPHS) Module loaded with four fueled clads; Perform steady state analysis to validate the thermal model via energy balance; Perform transient thermal analysis to predict clad temperatures at various times; and, Transient model results will be used to inform module soak time needed to reach a desired clad temperature prior to impact.

42 ENGINEERING↗

Investigation of desorption of hydrogen gas from polymer matrix using thermal desorption analysis and finite element modeling

Polymer materials are used widely as sealing materials and liners in hydrogen storage and transportation infrastructure. During operating conditions, polymers are exposed to high pressure hydrogen gas periodically. When in contact, the hydrogen gas diffuses through the polymer material with ease due to its smaller sized molecules compared to the polymer molecules. In the event of rapid decompression of outside hydrogen gas, the hydrogen molecules within the polymer diffuse out. This process is known as the desorption of polymer and can cause blisters or cracking causing permanent damage to the polymer. Here, we used a combined experimental and modeling approach to investigate the desorption of the hydrogen gas in the polymer. Thermal desorption analysis (TDA) experiments were performed on the polymer sample exposed to the high-pressure hydrogen gas to measure the diffusion coefficient and equilibrium hydrogen concentration. Experiments also provided the quantity of hydrogen within the polymer during the desorption process which followed Fick’s law. However, for higher pressurization values, some anomaly was observed in the quantity of hydrogen remaining in the polymer sample. A continuum mechanics based coupled diffusion–deformation-damage model was deployed to simulate the gas desorption process in the material using the finite element method to understand its effect on the material. It was found that the anomaly in TDA results were due to the blister formation on the polymer surface which resulted in longer hydrogen retention. Simulations also showed that blister formation can be affected by multiple parameters such as the addition of filler particles, and pre-existing cavity size.

36 MATERIALS SCIENCE↗

Geometry and size dependent microstructure and crack formation in Rene 41 superalloy fabricated by laser powder bed fusion

This study provides a systematic investigation into the size and geometry-dependent microstructural evolution and cracking susceptibility of LPBF-fabricated Rene 41. By coupling experimental microstructural analysis with thermal modeling, this research uniquely identifies the relationship between geometry-specific thermal histories, carbide coarsening, and liquation cracking. Four different geometries with varying thickness were fabricated with the identical process parameters. It was found that the grain size and morphology are not affected by the part size. However, the thinner parts exhibited coarser sub-grain structures compared to the thicker ones. The crack formation was observed for the parts with cross-sections smaller than 1 mm, whereas thicker parts had high density without any defects. Further, the cracks were observed in the interdendritic regions, suggesting that liquation cracking was the active micro-crack formation mechanism. The detailed microstructural analysis combined with a thermal finite element analysis proved that the heat extraction efficiency was lower for thinner parts causing a lower cooling rate and coarser carbides, making them more susceptible to constitutional liquation. Microhardness measurements were conducted for each geometry and correlated with the observed microstructural variations. The findings highlight the critical need for geometry-specific optimization of LPBF process parameters to mitigate cracking and achieve microstructural uniformity, offering valuable insights into the fabrication of complex, high-performance aerospace components.

36 MATERIALS SCIENCE↗

Progress Towards RF Conditioning of Low-Loss Couplers for a Conduction-Cooled Cryomodule

This work presents current progress on the conditioning of two new 25 kW couplers optimized for use in a compact, conduction-cooled SRF cryomodule. A connecting waveguide, previously used for conditioning the 805 MHz SNS couplers, was altered for use at 915 MHz. The necessary modifications were determined via RF modeling, while thermal analysis results identified additional cooling requirements during RF conditioning and provided insight about potential higher-power operation. Initial low-power conditioning will be performed with a 2.5 kW solid-state amplifier, with plans to use an industrial magnetron for RF conditioning at 25 kW in the near future.

Stilin, N. [Thomas Jefferson National Accelerator ↗

PROGRESS TOWARDS RF CONDITIONING OF LOW-LOSS COUPLERS FOR A CONDUCTION-COOLED CRYOMODULE

This work presents current progress on the conditioning of two new 25 kW couplers optimized for use in a compact, conduction-cooled SRF cryomodule. A connecting waveguide, previously used for conditioning the 805 MHz SNS couplers, was altered for use at 915 MHz. The necessary modifications were determined via RF modeling, while thermal analysis results identified additional cooling requirements during RF conditioning and provided insight about potential higher-power operation. Initial low-power conditioning will be performed with a 2.5 kW solid-state amplifier, with plans to use an industrial magnetron for RF conditioning at 25 kW in the near future.

Wilson, Christiana [Thomas Jefferson National Acce↗