Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thermal resilience”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Energy burden aware and thermal resilience informed thermal energy storage system planning for disadvantaged communities

Disadvantaged communities often face a disproportionate energy burden because they need to allocate a higher percentage of their income to energy costs. More importantly, climate change-induced extreme weather events, such as heat waves and severe cold snaps, exacerbate these communities’ energy burdens. As a result, low- and medium-income communities are more likely to experience energy supply disruptions, increased health risks, and elevated energy bills because of inadequate thermal insulation and airtightness in their houses. Thermal energy storage (TES) systems, such as large-scale (community-level) geothermal energy storage and small-scale (building-level) phase change material (PCM)–based storage, have a great potential to improve building energy efficiency and to enhance thermal comfort, load shifting, and integration with renewable energy. The objective of this study is to optimally allocate building level PCM-based TES systems at the community level by considering energy equity and extreme weather effects. To this end, we developed an energy burden and thermal resilience–informed TES system planning framework, which includes three modules: (1) a community-level energy burden and thermal resilience assessment module, (2) building-level a TES system integration and assessment module, and (3) a community-level optimal planning module. Case studies were conducted on four disadvantaged communities in Montgomery and Shelby Counties in Tennessee with energy burdens >10% and with high percentages of people of color. The results indicate that this comprehensive planning framework can assist disadvantaged communities in reducing their energy burden and in bolstering their resilience against the adverse effects of climate change.

Shen, Zhenglai↗

Thermal Resilience of Residential Building with Thermally Anisotropic Building Envelope Connected to Geothermal Sources

Heat waves and cold snaps have become more frequent and more intense because of climate change. A heat wave and a cold snap are a period of excessively hot and cold weather, respectively, that poses severe risks to building occupants’ health, especially for vulnerable people. They increase electrical energy consumption and put high stress on the grid which leads to potential power outages. Therefore, it is critical to assess and actively improve the thermal resilience of buildings to cope with heat waves, cold snaps, and power outages. The thermally anisotropic building envelope (TABE) is a novel active building envelope that can save energy while maintaining thermal comfort in buildings by redirecting heat and coolness from building envelopes to hydronic loops. When connecting to a ground thermal loop (GL), TABE can utilize the relatively stable temperature of the ground to protect the indoor environment during heat waves and cold snaps. This study assesses the thermal resilience of residential buildings that installed TABE and used ground thermal energy to supply the hydronic loops, abbreviated as ground thermal loop or TABE+GL. The simulation and analysis are conducted for the US Department of Energy prototype single-family detached residential building in the hot climate of Miami, Florida and Tucson, Arizona, and the cold climate of Denver, Colorado, and Rochester, Minnesota. Heat waves and cold snaps were obtained from the historical weather data of 1998-2020 for the studied regions. Three thermal resilience metrics, including the standard effective temperature (SET) degree-hours, the Heat Index, and the Hours of Safety (HOS) were used to quantify the effect of TABE+GL. The results showed that buildings installed TABE+GL could significantly reduce the average SET degree-hours above 30°C, increase HOS, and greatly improve thermal resilience.

Shen, Zhenglai↗

Nexus of thermal resilience and energy efficiency in buildings: A case study of a nursing home

Extreme weather events become more frequent and severe due to climate change. Although energy efficiency technologies can influence thermal resilience of buildings, they are traditionally studied separately, and their interconnections are rarely quantified. This study developed a methodology of modeling and analysis to provide insights into the nexus of thermal resilience and energy efficiency of buildings. In this work, we conducted a case study of a real nursing home in Florida, where 12 patients died during Hurricane Irma in 2017 due to HVAC system power loss, to understand and quantify how passive and active energy efficiency measures (EEMs) can improve thermal resilience to reduce heat-exposure risk of patients. Results show that passive measures of opening windows and doors for natural ventilation, as well as miscellaneous load reduction, are very effective in eliminating the extreme dangerous occasions. However, to maintain safe conditions, active measures such as on-site power generators and thermal storage are also needed. The nursing home was further studied by changing its location to two other cities: San Francisco (mild climate) and Chicago (cold winter and hot summer). Results revealed that the EEMs' impacts on thermal resilience vary significantly by climate and building characteristics. The study also estimated the costs of EEMs to help stakeholders prioritize the measures. Passive measures that may not save energy may greatly improve thermal resilience, and thus should be considered in building design or retrofit. Findings from this study indicate energy efficiency technologies should be evaluated not only by their energy savings performance but also by their influence on a building's resilience to extreme weather events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Defining weather scenarios for simulation-based assessment of thermal resilience of buildings under current and future climates: A case study in Brazil

In response to increasingly severe weather conditions, optimization of building performance and investment provides an opportunity to consider co-benefits of thermal resilience during energy efficiency retrofits. This work aims to assess thermal resilience of buildings using building performance simulation to evaluate the indoor overheating risk under nine weather scenarios, considering historical (2010s), mid-term future (2050s), and long-term future (2090s) typical meteorological years, and heat wave years. Such an analysis is based on resilience profiles that combine six integrated indicators. A case study with a district of 92 buildings in Brazil was conducted, and a combination of strategies to improve thermal resilience was identified. Results reflect the necessity of planning for resilience in the context of climate change. This is because strategies recommended under current conditions might not be ideal in the future. Therefore, an adaptable design should be prioritized. Cooling energy consumption could increase by 48 % by the 2050s, while excessive overheating issues could reach 37 % of the buildings. Simple passive strategies can significantly reduce the heat stress. A comprehensive thermal resilience analysis should ultimately be accompanied by a thorough reflection on the stakeholders’ objectives, available resources, and planning horizon, as well as the risks assumed for not being resilient.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal Resilience of Buildings and Communities: A Multistakeholder Review of Metrics and Approaches

Increasing temperature-related hazards require a collective effort to assess and enhance the thermal resilience of buildings and communities to protect occupants’ safety and minimize property or infrastructure damage. However, limited coordination across stakeholders and lack of standardized procedures for resilience assessment undermine the effectiveness of extreme temperature mitigation and adaptation strategies across the building life cycle. This review examines the current literature on resilience metrics to address thermal stress and risk due to extreme indoor environments. Stakeholders of thermal resilience include architects and engineers, occupants, property owners, real estate developers, urban planners, and policymakers. Additionally, motivations for measuring thermal resilience are emphasized, such as safeguarding occupant health and survivability, protecting property, and ensuring business continuity during extreme weather events. This review provides actionable insights and identifies future research needs for enhancing resilience through tailored metrics for stakeholders during the planning, design, construction, operation, and retrofitting phases of buildings and communities.

building life cycle↗

Assessing thermal resilience of an assisted living facility during heat waves and cold snaps with power outages

Extreme hot and cold weather events are becoming more frequent, intense, and longer due to climate change. When these events occur coincidentally with power outages, the resulting extreme indoor temperatures pose a severe health hazard for occupants. This study conducted a holistic modeling and analysis of an assisted living facility, where senior residents live, to assess its thermal resilience performance under a six-day heat wave in 2015 and a three-day cold snap in 2021 with power outages. Impacts of 13 energy efficiency measures on thermal resilience and backup power capacity of the facility were evaluated. Three thermal resilience metrics: the SET (standard effective temperature) degree-hours, the Heat Index, and the Hours of Safety, were used and calculated from the EnergyPlus simulation models. Furthermore, major findings are: (1) the facility would suffer from extreme temperatures during the cold and hot events without a power supply, not meeting the passive survivability requirements; (2) most passive envelope measures improve thermal resilience for both hot and cold events, but making the building envelope airtight results in conflicting performance between the hot and cold events; (3) natural ventilation is an effective measure to mitigate summer indoor overheating; and (4) the energy efficiency package can reduce backup power capacity by 19% for the three-day cold snap. It is recommended that building technologies and design strategies be evaluated to consider co-benefits of energy use, thermal resilience, and backup power needs through building energy codes or policies for existing and new buildings, which are transitioning for decarbonization and climate resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy efficiency and thermal resilience analysis for row houses using representative building energy models

Row houses, a prevalent medium-density urban archetype, were popularized during industrial era to accommodate the working class in the U.S. cities. Today, many of these structures are deteriorating, exacerbating the energy cost for residents with limited economic resources. Moreover, many households that lack Air Conditioning (AC) are vulnerable to extreme summer heat, an issue expected to worsen in the future. Energy-efficient retrofits can help mitigate these challenges. However, current literature provides limited insight into how existing building energy codes impact the energy efficiency and thermal resilience of row houses in current and future weather scenarios. This study provides a detailed method to address this gap by employing calibrated representative energy models of row houses as a baseline, and evaluating the annual energy savings and summertime thermal safety improvements from code compliant retrofits under current and future typical weather conditions. Using Baltimore City as a case study, results show that under current weather, retrofitting row houses yields significant energy savings along with notable thermal resilience improvements. The end unit row house realizes higher energy savings, whereas the interior unit experiences greater thermal resilience improvement after retrofitting. In future, retrofitted row houses can still save energy, but residents will face numerous hours of fatal indoor temperatures without AC in summer. Additionally, findings reveal stark zone-wise variations in thermal safety, and elevated humidity risks in certain zones post-retrofit, emphasizing the need for zonal retrofit strategies and better natural ventilation strategies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Multi-criteria thermal resilience certification scheme for indoor built environments during heat waves

With climate change, the indoor built environment is expected to significantly influence the occupant's safety and well-being. A novel multi-criteria thermal resilience certification scheme for indoor built environments during extreme heat events is proposed in this paper. The certification scheme considers overheating, thermal comfort, heat stress, and hygrothermal discomfort in built environments. These criteria are quantified using key performance indicators like indoor overheating degree, hours of exceedance, wet-bulb globe temperature, and heat index, respectively. This scheme is developed based on existing best practices like standards, rating systems, and literature. The scheme is implemented on a benchmark building energy performance model for detached post-World War II dwellings in Belgium as a case study using weather data measured from the City of Brussels. The indoor overheating in the reference dwelling is assessed with a static threshold of 27 °C for the bedrooms and adaptive thresholds for other areas. The analysis found that the building performance is within the defined threshold levels throughout the heat wave duration for all criteria. Therefore, the reference dwelling got a maximum attainable score of four points and is rated five-star for thermal resilience during heat waves. The proposed certification scheme is intended as a standardized framework and highlights the need for further revisions in building performance policies and guidelines.

Climate change↗

Investigation of pre-cooling as a recommended measure to improve residential buildings’ thermal resilience during heat waves

More intense heat waves are expected to occur more frequently in the twenty-first century. During severe heat waves, cooling capacity shortfall and overheating are likely to occur in residential buildings, and this will adversely affect occupant's thermal comfort and productivity. We propose a strategy of pre-cooling the house during off-peak hours to mitigate overheating during heat waves. Additionally, simulation results of a prototype single-family house show that adopting the rule-based control (RBC) of pre-cooling thermostat setpoint schedule is effective in reducing thermal discomfort, and that the efficacy of pre-cooling depends upon several building characteristics. An optimized control (OC) of the thermostat setpoint schedule was developed based on the simulation of a prototype building. A simplified yet improved RBC (IRBC) pre-cooling schedule was then extracted from the OC schedule for practical implementation at a larger scale. The effects of the RBC schedule and IRBC schedule were evaluated in the King District of Fresno, which contains 814 residential buildings. Results show that both thermostat setpoint schedules can reduce overheating effectively and that IRBC is slightly better than RBC for most buildings. The findings support the California government's recommendation on pre-cooling to mitigate overheating, which can be further improved with an optimized thermostat setpoint schedule broadcast to residents through early alert messages before a heat wave.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhancing thermal resilience of US residential homes in hot humid climates during extreme temperature events

Increasing occurrences of extreme weather events such as winter storms and heat waves due to climate change pose enormous safety and health-related risks to people, particularly in economically disadvantaged communities. In this study, we investigate some of the most promising retrofittable and weatherization methods to keep the living zone of residential buildings within an acceptable safety level. We use hours of safety as the resilience metric, which is defined as the time taken by the building's indoor environment to reach a safety threshold temperature. We first identify various passive measures, such as adding extra insulation, improving air sealing, and integrating phase-change materials, which can operate without any external power during winter-storm and heat-wave events. We then employ a whole-building simulation tool to examine the impact of various combinations of retrofit measures and conduct a parametric study to determine the optimal solutions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating indoor thermal resilience of passive and low-power cooling shelters for outdoor workers in India

India’s 231 million outdoor workers are exposed to deadly heat during heat waves. We report results from a simulation-based study that focuses on passive design of cooling shelters for the hot and dry climate zone of India. The goal is to design a cooler-than-outdoor shelter for outdoor workers’ intermittent rest and recovery from heat stress during their arduous outdoor work, to avoid heat-related morbidities and mortality. Expected indoor thermal conditions in low-cost cooling shelters deploying a range of passive designs and low-power active measures are investigated, consistent with the current Indian standards and practices, located in the city of Jodhpur in western India. Heat resilience of the shelter was measured with the predicted reduction of hazardous hours inside the shelter based on the wet-bulb globe temperature (WBGT) and extended heat index. These measures include improving the building envelope, installing cool roofs, using internal thermal mass, and natural ventilation. Additionally, a low-power active measure of using ventilation fans and ceiling fans is explored. EnergyPlus-based simulation results show that simple, commonly available measures, particularly natural ventilation and ceiling fans, achieve the most significant reductions in overheating danger hours, by 22% and 21%, respectively, while more complex or costly passive strategies yield only marginal additional benefits. Moreover, combined measure packages are identified that can reduce the indoor WBGT by 8 to 10 °C, eliminating overheating danger hours. These findings highlight the critical importance of scalable, low-cost, and easily deployable cooling solutions for developing resilient cooling shelters for vulnerable outdoor workers during heat waves in India.

building performance↗

Innovative Symmetrical Electrolyte Architecture Enables Ultra-Flat and Thermal Resilient Protonic Ceramic Electrochemical Cells

Protonic ceramic electrochemical cells (PCECs) represent a promising class of solid‐state energy conversion devices capable of high‐efficiency hydrogen production and power generation. However, the practical deployment of planar PCECs is fundamentally constrained by severe structural deformation and mechanical failure during fabrication, stemming from asymmetric shrinkage between the thin electrolyte and the thick NiO‐based support layer. Here, in this work, a functionally integrated, symmetry‐engineered double‐sided electrolyte (DE) design is unveiled, which not only suppresses thermally induced curvature but also unlocks significant gains in electrochemical performance and stability. This architecture intrinsically balances shrinkage dynamics across the cell bilaterally, enabling the fabrication of ultra‐flat 5 × 5 cm 2 cells with sub‐100 µm thickness variation. A numerical solid mechanics simulation is introduced to investigate and interpret this achievement. Beyond structural advantages, the DE configuration enhances the cell operational stability, delivering a low open‐circuit voltage degradation of 9.5 mV/100 h across 80 thermal cycles. This work establishes a compelling paradigm wherein architectural symmetry directly translates to both mechanical fidelity and functional enhancement, offering a promising route toward PCECs scale‐up.

08 - HYDROGEN↗

Engineering Thermally Resilient and Kinetically Active Reversible Protonic Ceramic Cells via Interfacial Design

Achieving concurrent fast electrode kinetics and long-term thermo-mechanical durability remains a critical challenge for reversible protonic ceramic electrochemical cells (R-PCECs). Herein, we report an interfacial engineering strategy that integrates a perovs.kite-type PrBaRu0.1Co1.9O5+δ (PBRC) nanoparticle layer onto a PrBa0.5Sr0.5Co1.5Fe0.5O5+δ (PBSCF) substrate (PBRC-PBSCF), together with a modified pellet-assisted sintering approach to fabricate dense BaZr0.4Ce0.4Y0.1Yb0.1O3-δ (BZCYYb4411) electrolytes. The in situ reconstructed heterointerface enhances oxygen reduction/evolution reaction (ORR/OER) kinetics, promotes H2O adsorption/dissociation, and improves steam tolerance, as verified by electrochemical measurements and interfacial microstructural analyses. Density functional theory reveals that Ru-induced electronic modulation at the PBRC-PBSCF interface lowers the energy of oxygen vacancy formation and optimizes the position of the O 2p band center, thereby accelerating oxygen redox kinetics and stabilizing the interface. The resulting R-PCECs deliver an excellent peak power density of 1.112 W cm−2 and an electrolysis current density of −1.257 A cm−2 at 1.3 V in 3% H2O wet air at 600°C, with a reasonable faradaic efficiency. Furthermore, the cells demonstrate excellent stability, sustaining 100 h of thermal cycling (400–600°C, 200°C h−1) in both fuel cell and electrolysis modes, with 600 h of stability in electrolysis mode (600°C, −0.5 to −2 A cm−2).

30 DIRECT ENERGY CONVERSION↗

High-performance windows improve thermal survivability of occupants during cold snaps

Exposure to low indoor air temperature is a major contributor to temperature-related mortality during extreme cold events, especially when power outages disrupt operation of space heating systems. This study explores the impact of high-performance windows on the thermal resilience of residential buildings during extreme cold weather and grid power outages, as well as their long-term benefits through energy efficiency and reduced risk of property damage. Building performance simulations were conducted for reference residential buildings in three construction vintages and two major U.S. cities located in cold climate zones, considering two types of extreme cold events: short and severe, and long and milder. Our research found that even houses compliant with current energy codes struggle to maintain safe indoor temperatures for more than a few hours during power outages, necessitating rapid evacuations. High-performance windows can extend the thermal survivability time by up to 3.8 days within a 7-day cold snap and significantly reduce risk of bursting frozen water pipes, depending on the building’s insulation and infiltration level, cold event severity, and occupant vulnerability. This extended thermal safety time is crucial in scenarios where reduced mobility complicates emergency responses in senior housing. In addition to boosting thermal resilience, upgrading older homes with high-performance windows can reduce heating energy consumption by over 18% and cooling energy by 15%. Our findings highlight the need to incorporate thermal resilience assessments into new designs or major retrofits, including the use of typical and extreme weather scenarios and advanced technologies like high-performance windows.

Krelling, Amanda F↗

Multi-scenario Extreme Weather Simulator application to heat waves: Ko’olauloa community resilience hub

Heat waves are increasing in severity, duration, and frequency. The Multi-Scenario Extreme Weather Simulator (MEWS) models this using historical data, climate model outputs, and heat wave multipliers. In this study, MEWS is applied for planning of a community resilience hub in Hau'ula, Hawaii. The hub will have normal operations and resilience operations modes. Both these modes were modeled using EnergyPlus. The resilience operations mode includes cutting off air conditioning for many spaces to decrease power requirements during emergencies. Results were simulated for 300 future weather files generated by MEWS for 2020, 2040, 2060, and 2080. Shared socioeconomic pathways 2-4.5, 3-7.0 and 5-8.5 were used. The resilience operations mode results show two to six times increase of hours of exceedance beyond 32.2 °C from present conditions, depending on climate scenario and future year. The resulting decrease in thermal resilience enables an average decrease of energy use intensity of 26% with little sensitivity to climate change. The decreased thermal resilience predicted in the future is undesirable, but was not severe enough to require a more energy-intensive resilience mode. Instead, planning is needed to assure vulnerable individuals are given prioritized access to air-conditioned parts of the hub if worst-case heat waves occur.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydronic Shell: An Affordable Solution for Multifamily Deep Energy Retrofit

Approximately 42% of multi-family buildings in the United States have do not have insulation as required by the building codes. Envelope retrofits of these buildings are needed to improve their thermal performance, provide thermal resilience, and enable a pathway to electrification of space heating systems. Hydronic shell (HS) is a retrofit technique where a stud wall layer is added to a masonry wall along with a convective coil and a fan coil unit fitted in the façade cavity which can provide both heating and cooling to the space. The HS system serves a dual purpose of 1) retrofitting the building envelope and 2) retrofitting the HVAC system and enabling electrification of space heating. The electrification of space heating is possible from the installation of a combination of hydronic system/fan coil unit system which uses a central heat pump as a source of heating water in the cavity between the existing wall and retrofit insulation layer. This study evaluates the performance of the HS system at varying outdoor conditions mimicked by a climate chamber and hot water supply temperature from a water bath. During the ramp-up period, the indoor chamber temperature could be increased from 66 ºF to 69.5 ºF within an hour using heating water at 120 ºF when the outdoor chamber temperature was at 0 ºF. When the indoor chamber temperature was maintained within a deadband, variation in cavity air temperature was mostly influenced by the duration when water was flowing through the cavity convector. It was seen from the testing that the hydronic system alone without use of fan in the system is able to maintain the space temperature at coldest outdoor condition used in the experiment (0 ºF) even at lowest hot water supply temperature chosen (90 ºF). During the ramp-down period, the fastest decline in temperature took 6.4 hours from temperature to drop from 69.6 ºF to 66 ºF which shows tremendous potential of thermal resilience and peak load shifting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗