Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thermoluminescent Dosimetry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Comparison of the performance of TLD, OSL and RPL personal dosimetry systems to the American National Standard Institute (ANSI) test categories

The Laboratory Accreditation Program (LAP) tests the capability and performance of the United States Department of Energy's (USDOE) facilities to accurately measure and quantify the whole-body and extremity radiation equivalent doses to the occupational workers. The dosimetry methods used in personal dosimetry can be Thermoluminescence (TL), Optically Stimulated Luminescence (OSL) and Radiophotoluminescence (RPL), among other techniques available. Currently, the TL (LiF:Mg,Ti) and OSL (Al 2 O 3 :C) dosimetry systems are DOELAP-accredited for occupational dose measurements and regulatory reporting. In this study, the performance of a beryllium oxide (BeO) OSL dosimetry system and of a silver-doped phosphate glass RPL dosimetry system is compared against the performance of an accredited LiF:Mg,Ti TL dosimetry system. The bias and standard deviation in each of the performance test categories are compared between these three systems for exposures to photons, beta, and mixed radiation fields with the criteria established by the American National Standard Institute (ANSI) and Health Physics Society (HPS) N13.11-2022 standard. The practical implementation of the dosimetry program and its equivalency to the occupational personal equivalent dose H p (0.07) and H p (10) measurements were evaluated. The TL, OSL and RPL dosimetry systems passed the ANSI performance test criteria for H p (0.07) and H p (10) occupational dose measurements and met the DOELAP accreditation requirements.

61 RADIATION PROTECTION AND DOSIMETRY↗

A neutron fluence map of the Los Alamos National Laboratory Godiva IV critical assembly

A neutron fluence map and a total ionizing dose map of the Los Alamos National Laboratory Godiva IV fast burst critical assembly was generated using passive reactor dosimetry, comprised of sulfur pellets and thermoluminescent dosimeters. Godiva IV is an unmoderated, fast burst, critical assembly constructed of approximately 65 kg of highly enriched uranium fuel alloyed with 1.5 % molybdenum for strength. The mapping was performed during a single 75.6 ºC temperature rise burst operation, with the top and sides of the cylindrical Godiva-IV Top Hat covered in passive dosimetry. Dosimetry was placed in a symmetric pattern around the Top Hat, with higher concentrations near the control rods and burst rod. A specific portion of the lower quadrant of the burst rod was mapped to confirm a testing region where the neutron fluence varied by no more than ± 5%. The results will be used to assess the neutron, gamma, and total ionizing dose environment in three-dimensional space around the assembly for higher fidelity experiment placement, active dosimetry positioning, and radiation field characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of Stochastic Gradient Descent in an Automated Glow Peak Identification Software for Multiple Thermoluminescent Dosimeter Types

A glow-curve analysis code was previously developed in C++ to analyze thermoluminescent dosimeter glow curves using automated peak detection while applying a first-order kinetics model. A newer version of this code was implemented to improve the automated peak detection and curve fitting models. The Stochastic Gradient Descent Algorithm was introduced to replace the prior approach of taking first and second-order derivatives for peak detection. Additionally, early stopping mechanisms were invoked to improve the previously used Levenberg-Marquardt Algorithm employed for curve fitting. The two software versions were compared through glow curve analysis of different thermoluminescent dosimeter materials and calculation of the corresponding figures of merit. Altogether improvements were shown, namely an increase in the number of peaks detected and a reduction of the mean figure of merit by approximately 46%.

137Cs↗

Thermoluminescence and optically stimulated luminescence response of Al 2 O 3 coatings deposited by mist-chemical vapor deposition

Aluminum oxide (Al 2 O 3 ) is a widely used ceramic material which can be applied as a protective coating on metallic structures to improve corrosion resistance and mechanical properties. Al 2 O 3 also has great potential as a functional thin film device in optoelectronics. When it is doped with carbon (Al 2 O 3 :C), this material system can serve as a reliable radiation dosimeter. The combination of optoelectronic, dosimetric, and protective properties demonstrated by Al 2 O 3 uniquely positions it for dual use applications in nuclear forensics, nonproliferation and safeguards, emergency response, retrospective dosimetry, and nondestructive inspection. Here, in this study, an innovative ultrasonic mist-chemical vapor deposition (Mist-CVD) system was used to deposit thin (nm level) Al 2 O 3 coatings on 304 stainless steel substrates. The single aliquot regeneration (SAR) and additive dose reconstruction techniques were then used to investigate the thermoluminescence (TL) and optically stimulated luminescence (OSL) response of the coated substrates to increasing doses of β irradiation. This study demonstrates that nm-thick Al 2 O 3 coatings hold promise as novel nano-dosimeters which could be leveraged for a series of applications such as nonproliferation and safeguards, retrospective dosimetry, and nondestructive inspection.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Au-198 and TLD-600 results from IER-593 Godiva irradiations

This report summarizes the results from dosimetry packets deployed during a nominally 250 ◦C temperature rise Godiva IV burst. Dosimetry packets including Bare Au foils, Cd covered Au foils, and Thermoluminescent Dosimeters (TLDs) were deployed at five positions around Godiva at a height corresponding to the center height of the HEU fuel.

61 RADIATION PROTECTION AND DOSIMETRY↗

Preliminary Thermoluminescent Dosimeter Glow Curve Analysis with Automated Glow Peak Identification for LiF Mg,Ti

When appropriately analyzed, thermoluminescent dosimeter glow curve analysis allows for improved quantification of thermoluminescent material behavior while flagging abnormalities. The mathematical separation of a glow curve into contributions from energetically unique trap states, or glow curve analysis, may be used to remove undesired effects of signal fading for complex materials. A generalized glow curve analysis software for the separation of glow curves is presented in this paper. Written in C ++ , the software uses the first-order kinetics model with automatic peak identification. The automatic identification of peaks is achieved through a unique peak-finding algorithm. Here, the program was performance tested using experimental glow curve data from LiF:Mg,Ti, and comparative results are presented.

47 OTHER INSTRUMENTATION↗

Preliminary Experiences with the Rexon UL-320-FDR: An Automated Thermoluminescent Dosimeter Reader with Removable Contact Heating Planchets and an Infrared Temperature Feedback System

The Rexon UL-320 FDR is a novel resistive-heating thermoluminescent dosimeter reader with a unique temperature measurement system and an automated dosimeter processing mechanism. The removable contact heating planchets have black-body adhesives on the back for capturing temperature information with infrared sensors. A heating cycle feedback loop ensures accurate, precise, and reproducible heating sequences. Heating rates between 0.8 and 40°C s -1 for up to 1,000 s are possible. Photomultiplier tube sensitivity and drift, dark current counts, and planchet glow were measured experimentally. Additionally, 25 LiF:Mg,Ti dosimeters were calibrated to demonstrate reader performance. Sensitivity was optimized at 1,200 V, which produced the highest reference light count to dark current count ratio while extending photomultiplier tube life. Dark current counts measured with typical time-temperature profiles for LiF:Mg,Ti were below 10 counts per channel but increased by up to 2.5% for more extreme heating cycles. Reader sensitivity drifts of up to 10% were observed during extended automated operations with typical time-temperature profiles. Total counts resulting from planchet glow decreased with faster heating rates. Calibrations performed with LiF:Mg,Ti dosimeters yielded results comparable to more established reader designs. Spikes were observed in ~3% of the glow curves from planchet dust and oil burning off at elevated temperatures. The use of N 2 gas and sensitivity drift corrections are recommended to improve dosimetry performance for the UL-320 FDR reader.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dose conversion factors for absorbed dose in a mobile phone to absorbed dose in critical organs in an anthropomorphic phantom for emergency dosimetry applications: OSL and TL experimental results, and Monte Carlo simulations

Here, an anthropomorphic phantom was equipped with three smartphones and irradiated in five separate exposure geometries in air using a 137 Cs source. The phantom was fitted internally with thermoluminescence dosimeters (TLD-700 chips) to measure the absorbed dose to the individual organs, while the absorbed doses in the phones were evaluated using optically stimulated luminescence (OSL) from the phones’ surface mount resistors (SMRs), along with reference dosimeters, namely Luxel OSL films and TLD-700 chips. The results indicate a strong dependence on the phone location with respect to the source due to shielding and scattering from the body. Dose conversion factors were calculated for several plausible exposure scenarios in order to correlate the absorbed doses measured in the phones to the average body dose received by the phantom. The measured conversion factors were compared with calculated factors using MCNP6.2 Monte Carlo simulations and an ADAM voxel phantom. Experiments were conducted to assess how the phone orientation and angle impacts the dose received by the phone components. The overall results indicate that the doses measured can vary significantly depending upon exposure geometry (including phone position and angle). However, in rotational irradiation symmetry, the phone doses lead to an over-estimate of the average whole-body dose by an average of ~10%, independent of the phone locations tested in this study. This result, if confirmed in future studies, may be acceptable for triage.

61 RADIATION PROTECTION AND DOSIMETRY↗

X-ray Inspection Model Validation with Physical Dosimetry

A non-functional printed circuit board assembly was developed using ULTIboard and a simple computational transport model was created for use with the Monte Carlo software MCNP. EBT 3 film radiography was used to compare with Monte Carlo simulation to validate the board representation. The computational transport model was then revised to include connection pins, solder balls, highly attenuating internal structures, and copper trace distribution. Results from the revised model were compared to the EBT 3 films to observe improvements to dose profiles. It was found that this method was useful in verifying the placement of components, as the dose profiles were observed to follow the same trends. The experiment was then repeated using XRQA 2 films to achieve the same level of contrast with 1% the dose of EBT 3 films. It was found that high contrast may be achieved using these films to identify major issues with the model geometry, at a cost of dose profile accuracy. A second validation method was applied to the model using 37 CaF 2 thermoluminescent dosimeters (TLDs). TLD measurements were compared with the simplified and complex transport models to identify the features that have the greatest impact on simulation accuracy. The TLD calibration to CaF 2 was found to be accurate within 5.6%, while calibration to dose in Si was found to be accurate within 4.7%. Finally, it was observed that the accurate representation of solder balls and proper modeling of highly attenuating internal structures had the greatest impact on simulation accuracy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Fading study of Harshaw LiF:Mg,Ti thermoluminescence dosimeters exposed to neutron doses

Sensitivity and signal fading were tested in Harshaw LiF:Mg,Ti thermoluminescence dosimeters (TLDs) exposed to neutron and beta/photons doses. A significant difference in the signal fading rate was observed for TLDs exposed to neutrons compared with TLDs exposed to betas. This difference may have been related to differences in glow curves for dosimeters exposed to different beams and to differences in glow curve evolution after exposure. A fading-correction algorithm was developed to correct the cumulative sensitivity + signal fading of TL doses for the fading time t using the formulae: y = 0.147∗exp(-t/4.36) + 0.308∗exp(-t/34.1) + 0.73 for neutrons, and: y = 0.132∗exp(-t/10.72) + 0.174∗exp(-t/31.5) + 0.8 for betas/photons. The formula was validated using the dose recovery test, where the average deviation of fading-corrected doses from delivery doses was within 1%. In conclusion, the proposed fading-correction approaches may significantly improve the accuracy of Harshaw TL dosimetry with LiF:Mg,Ti cards for both neutron and beta/gamma irradiation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Gamma Dose Measurements in ZPPR-15

Gamma doses were measured in the Zero Power Plutonium Reactor (ZPPR) to provide data for validation of calculations of gamma heating in important reactor components. Stainless steel-encapsulated LiF thermoluminescent dosimeters (TLDs) were irradiated in two configurations in ZPPR-15B and one configuration in ZPPR-15D to provide gamma heating data for the Integral Fast Reactor design in the mid-1980s. The ZPPR-15 experimental records were used to develop detailed as-built Monte Carlo models for the gamma dose measurements in ZPPR-15B and ZPPR-15D. These Monte Carlo models can be converted to deterministic models for calculations with deterministic codes. The reported uncertainty in the published gamma dose measurements is just the statistical uncertainty in the TLD readout. In addition to this statistical uncertainty in the TLD readout, several corrections and other factors contribute to the total uncertainty for the gamma dose measurements. The total uncertainty for the gamma dose measurements can be significantly larger than the published statistical uncertainty for the TLD readout. All known contributions to the total uncertainty were analyzed, and a total uncertainty was derived for the ZPPR-15 gamma dose measurements.

36 MATERIALS SCIENCE↗

Directional dependence of equilibrated TLD-400 chips in multiple radiation fields

Fielding of thermoluminescent dosimeters (TLDs) for measurement of photon radiation dose in experiments is the standard practice for γ-irradiation facilities, pulsed power x-ray facilities, and reactor facilities at Sandia National Laboratories (SNL). Due to the high-dose experimental conditions and the mixed ( 1 n, γ) fields in these facilities, SNL radiation metrologists have historically used CaF 2 :Mn TLDs (also known as TLD-400). Recent inquiries to the radiation metrology staff have raised concerns that the aluminum-equilibrated TLD-400 chips may exhibit a directionally dependent response. The metrologists were asked whether the dose measured by the chip may be impacted by the angle of incidence on the equilibrated TLD. To provide a thorough answer to this query, a set of adjoint Monte Carlo radiation transport calculations was performed for three different equilibrated TLDs as well as bare TLD chips using the Integrated Tiger Series (ITS) code. The key feature of the adjoint calculations performed in this study is that each photon escaping the modeled geometry was tallied into angular bins to provide information on both the energy and angular dependence of the equilibrated chip. After the adjoint Monte Carlo calculations were completed, the resulting energy-dependent response function for each angular bin was convolved with multiple photon energy spectra representing various radiation facilities at SNL. The radiation facilities selected for analysis span a range of photon energies from approximately 1 keV up to approximately 20 MeV. Thus, the presented results are applicable to a wide variety of radiation facilities around the world. Although the bare TLD-400 chip was expected to display the largest variation due to the photon angle of impact on the dosimeter, the dosimeter with the thinnest aluminum equilibrator (SNL thin equilibrated TLD-400) was determined to have the biggest differential between the impact angle with the maximum dose ( D max ) and the impact angle with the minimum dose ( D min ). However, the SNL normal equilibrated TLD-400 chip demonstrated a dramatic reduction in that differential between maximum and minimum dose angles. The reduction in this differential is one of the dominant factors in experimenters’ choice to field these dosimeters at SNL radiation facilities. The results from the PNNL (Hanford) energy-flattening field capsule are consistent with the previous publications. The differential dose responses due to the photon impact angle indicate that experimenters should strive to field their TLD-400 dosimeters in a consistent manner to avoid additional uncertainty in the measurements based on dosimeter orientation.

Adjoint radiation transport↗