Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thin Sections”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Secondary Ion Mass Spectrometry Methodology for Isotopic Ratio Measurement of Micro‐Grains in Thin Sections: True Grain Size Estimation and Deconvolution of Inter‐Grain Size Gradients and Intra‐Grain Radial Gradients

In a thin section, grains that were approximately spherical in situ appear circular in cross section, and the distribution of apparent diameters frequently assumed to be their size distribution. Scanning ion imaging by secondary ion mass spectrometry (SIMS) is capable of providing precise (< 1‰) stable isotope ratio measurements of such grains, but, importantly, also registers their rate of evolution in apparent size as they are ablated by the primary beam. By assessing rates of radius change with depth, the described methodology enables the ‘true’ size of grains to be estimated, as well as the distance of the sectioned surface from the original grain centre. Transects in three dimensions are made possible, and this capability enables better identification (and thus separation) of both inter‐grain chemical signatures as a function of grain size, and intra‐grain radial trends. In this example, we highlight the specific application to pyrite (FeS 2 ) minerals, which are frequently analysed by SIMS to determine their inter‐grain and intra‐grain geochemical variations, particularly in their sulfur stable isotopic ratios (δ 34 S). Benefits of the new methodology over the Faraday cup ‘spot mode’ are described. Data correction algorithms and precision considerations are discussed.

Jones, Clive↗

Documentation of Destructive Analyses on Thin Sections in the US Antarctic Meteorite Collection

Detailed studies and analytical measurements are commonly made using thin sections of rocks affixed with epoxy to a slide. Thin sections [1,2] are a convenient medium in which to study rocks and meteorites, and fit into sample holders compatible with many instruments. Thin sections can also be used multiple times by different researchers, and many meteorite thin sections from the US Antarctic meteorite collection, have been utilized by 5 to 6 researchers over their 40 year lifetime. Thin sections are thus a scientifically valuable resource that must be preserved, documented and conserved over time. Analytical capabilities for meteorite and other sample studies have progressed extensively in the last 20 years, including many different kinds of analysis of high spatial resolution on thin sections. The progression to analysis on small samples has provided new and efficient ways to characterize samples while also preserving more material for future generations to study. While the development of analytical tools has expanded, many of these analyses are destructive in the sense that small pits or holes or other effects of the analysis are created on the thin sections. Preserving material for future generations thus requires recording the effects of multiple analyses on thin sections. Here we describe the process used for documenting the effects of various analyses on thin sections in the US Antarctic meteorite collection.

thin section↗

Making Thin Sections from National Treasures: A Little Moon Rock Goes a Long Way

NASA’s Johnson Space Center curates the Apollo sample collection through their facilities in Houston, TX. It is a dual-purpose facility, intended both to store and preserve the precious samples, as well as to make them available for ongoing scientific study and public examination. The facilities consist of multiple vaults and lab spaces, including the Apollo Thin Section Lab. Although it is a part of the Curation facilities, this lab is intended to process specific lunar rock and dust samples into what are called “thin sections”. A thin section is a microscope slide with a very thin, highly polished slice of rock material mounted on it. These are used not only for microscope viewing, but also for a range of other sophisticated scientific instruments to map and measure fine details of the rock’s physical and chemical composition and structure. The process of making a thin section requires great care and patience and is an art in itself; each one is unique, and each sample can behave very differently while going through the same basic procedures. In general, it begins by taking a small chip of rock from a much larger sample. The rock fragment is placed within a small mold and liquid epoxy is poured over it and allowed to harden, producing what is called a “potted butt” (Figure 1). This is to stabilize the rock so that it won’t fragment or crumble during polishing, and to fill any cracks or voids within the rock. Once hardened, the epoxy on the bottom is carefully ground away to expose the rock surface within, which is then polished to a 1-micron finish. A thin new layer of fresh epoxy is then applied to the polished surface and used to mount it to a silica slide. Once the mounting epoxy has hardened, the potted butt is cut off less than one millimeter above the slide using a low-speed circular saw. This thin layer of sample material attached to the slide undergoes further grinding and polishing, typically bringing the sample thickness down to about 35 microns – roughly one third of the thickness of a human hair. The remaining potted butt is saved for future scientific investigations and can be re-polished and used again until all the rock material within it is used up. A single thin section can be reused countless times by numerous different researchers. In addition, thin sections are often exquisitely beautiful (Figure 2) and in some cases, lunar thin sections are used as public display samples, such as at the Smithsonian Air and Space Museum in Washington, DC. The production of thin sections allows an immense variety of research to be conducted on a tiny amount of rock or mineral material, allowing the bulk of the Apollo collection to stay pristine and unaltered, and thus, remain available for next generation of lunar scientists to further our insight into the Moon’s geological diversity, and to bring valuable new insights to our understanding of the origin of the Earth-Moon system.

J J Kent↗

Raman Microscopy Analysis of Wyoming CarbonSAFE Pilot Well Thin Sections for Mineralogy and Organic Matter Characterization

Scanning confocal Raman microspectroscopy (RMS) was used to analyze thin sections for inorganic mineral content and for evaluation of organic material (OM). Thin sections were selected from a stratigraphic test well core in the Powder River Basin, Wyoming under the Wyoming CarbonSAFE project. The well was analyzed with a variety of rock and fluid characterization techniques to determine the feasibility of a commercial-scale CO2 storage site. RMS complements other analyses, including traditional petrography, SEM, porosity and permeability, and XRD For this aspect of the study, RMS is especially important in the evaluation of OM in sealing lithologies. At prospective geologic CO2 storage sites, it is imperative to assess the unconventional oil and gas potential of seals to ensure that any future development would not compromise the integrity of the seals. Whole-slide mineralogical surveys were performed on thin sections from various shale and sandstone formations. Surveys were analyzed with Direct Classical Least Squares to identify and quantify minerals. The location and concentration of minerals was color-coded and overlaid on optical images for visualization of the distribution of minerals. Dense hyperspectral Raman mapping of OM was performed on five thin sections. Eleven spectral parameters diagnostic of organic type and thermal maturity were used to train a Partial Least Squares (PLS) calibration against a set of artificially matured samples spanning the pre- to mid-oil window. The PLS was applied to the study set and a post-mature set. Additionally, the PLS was applied to each point in hyperspectral maps for visualization of trends in maturity across sample sets and discrimination of organic matter types within a given map. In inorganic surveys on thin sections, a total of 14 unique inorganic minerals were identified in Raman spectra including quartz, dolomite, calcite, hematite and anhydrite. Shale thin sections tended to be dominated by organic material. OM was often observed mixed with inorganic minerals. Sand- and mudstones were dominated by inorganic minerals. The PLS extrapolated the post-mature set to reflectances >1.2%. The study set ranged from very immature to postmature in the median of map fit-peak parameters. However, point maturity maps indicate that matrix OM in all study samples is immature and that discreet organic particles selected for mapping, which may be inertinites, bias medians towards more-mature. The work demonstrates the capabilities of RMS to perform both whole-slide mineralogy and OM analysis with applications to formation evaluation in oil & gas, carbon sequestration and mining. Here, analysis of sealing formations in the well indicates high levels of immature organic matter that would not be a viable target for future oil production that could compromise the CO2 storage site. The work brings together diverse disciplines from geology and petrography to analytical chemistry, big data and microscopy.

Myers, Grant↗

Ultrafast Phase Mapping of Thin-Sections from An Apollo 16 Drive Tube - a New Visualisation of Lunar Regolith

Polished thin-sections of samples extracted from Apollo drive tubes provide unique insights into the structure of the Moon's regolith at various landing sites. In particular, they allow the mineralogy and texture of the regolith to be studied as a function of depth. Much has been written about such thin-sections based on optical, SEM and EPMA studies, in terms of their essential petrographic features, but there has been little attempt to quantify these aspects from a spatial perspective. In this study, we report the findings of experimental analysis of two thin-sections (64002, 6019, depth range 5.0 - 8.0 cm & 64001, 6031, depth range 50.0 - 53.1 cm), from a single Apollo 16 drive tube using QEMSCAN . A key feature of the method is phase identification by ultrafast energy dispersive x-ray mapping on a pixel-by-pixel basis. By selecting pixel resolutions ranging from 1 - 5 microns, typically 8,500,000 individual measurement points can be collected on a thin-section. The results we present include false colour digital images of both thin-sections. From these images, information such as phase proportions (major, minor and trace phases), particle textures, packing densities, and particle geometries, has been quantified. Parameters such as porosity and average phase density, which are of geomechanical interest, can also be calculated automatically. This study is part of an on-going investigation into spatial variation of lunar regolith and NASA's ISRU Lunar Simulant Development Project.

Botha, Pieter↗

Carbonaceous Chondrite Thin Section Preparation

Carbonaceous chondrite meteorites have long posed a challenge for thin section makers. The variability in sample hardness among the different types, and sometimes within individual sections, creates the need for an adaptable approach at each step of the thin section making process. This poster will share some of the procedural adjustments that have proven to be successful at the NASA JSC Meteorite Thin Section Laboratory. These adjustments are modifications of preparation methods that have been in use for decades and therefore do not require investment in new technology or materials.

Harrington, R.↗

A petrographic thin sectioning technique for evaluating composite materials

Petrographic thin sectioning by a low-speed diamond saw has been used in conjunction with transmission polarized light microscopy for the characterization of the microstructure and deformation mechanisms of a variety of polymer systems. It has proven possible by these means to study three types of thermoplastic matrices for composite applications: PEEK, BPA-based polycarbonate (PC), and a rubber-modified PC. The reinforcing fibers for these matrices were in all cases AS4 carbon fibers, unidirectionally arrayed. Superior analyzability of matrix morphology and subsurface fracture processes is achieved by thin sectioning.

Parker, D. S.↗

Ureilite Thin Section Preparation

Preparing thin and thick sections of ureilite type meteorites is a challenge that can confound even the most experienced section preparer. A common characteristic of these samples is the presence of carbon phases, particularly nanodiamonds, in the matrix along silicate grain boundaries, fractures, and cleavage plains [1]. The extreme hardness of the nanodiamonds presents a challenge to the section preparer in the form of high surface relief on the section. This hard material also causes considerable wear and tear on equipment and materials that are used for making the sections. These issues will be discussed and potentially helpful measures will be presented.

Harrington, R.↗

Cometary particles - Thin sectioning and electron beam analysis

Thin sections (500 to 1000 angstroms thick) of individual micrometeorites (5 to 15 micrometers) have been prepared with an ultramicrotome equipped with a diamond knife. Electron microscope examination of these sections has revealed the internal structures of chondritic micrometeorites, and a subset of highly porous, fragile particles has been identified. Delicate meteoritic materials such as these are characteristic of debris from cometary meteors.

Bradley, J. P.↗

Synchrotron X-Ray Diffraction Analysis of Meteorites in Thin Section: Preliminary Results

X-ray diffraction is the pre-eminent technique for mineral identification and structure determination, but is difficult to apply to grains in thin section, the standard meteorite preparation. Bright focused X-ray beams from synchrotrons have been used extensively in mineralogy and have been applied to extraterrestrial particles. The intensity and small spot size achievable in synchrotron X-ray beams makes them useful for study of materials in thin sections. Here, we describe Synchrotron X-ray Diffraction (SXRD) in thin section as done at the National Synchrotron Light Source, and cite examples of its value for studies of meteorites in thin section.

Treiman, A. H.↗

Evaluating Mesorectal Lymph Nodes in Rectal Cancer Before and After Neoadjuvant Chemoradiation Using Thin-Section T2-Weighted Magnetic Resonance Imaging

Purpose: To apply thin-section T2-weighted magnetic resoance imaging (MRI) to evaluate the number, size, distribution, and morphology of benign and malignant mesorectal lymph nodes before and after chemoradiation treatment compared with histopathologic findings. Methods and Materials: Twenty-five patients with poor-risk adenocarcinoma of the rectum treated with neoadjuvant chemoradiation were evaluated prospectively. Thin-section T2-weighted MR images obtained before and after chemoradiation treatment were independently reviewed in consensus by 2 expert radiologists to determine the tumor stage, nodal size, nodal distribution, and nodal stage. Total mesorectal excision surgery after chemoradiation allowed MR nodal stage to be compared with histopathology using {kappa} statistics. Nodal downstaging was compared using the Chi-square test. Results: Before chemoradiation, 152 mesorectal nodes were visible (mean, 6.2 mm; 100 benign, 52 malignant) and 4 of 52 malignant nodes were in contact with the mesorectal fascia. The nodal staging was 7/25 N0, 10/25 N1, and 7/25 N2. After chemoradiation, only 29 nodes (mean, 4.1 mm; 24 benign, 5 malignant) were visible, and none were in contact with the mesorectal fascia. Nodal downstaging was observed: 20/25 N0 and 5/25 N1 (p < 0.01, Chi-square test). There was good agreement between MRI and pathologic T-staging ({kappa} = 0.64) and N-staging ({kappa} = 0.65) after chemoradiation. Conclusions: Neoadjuvant chemoradiation treatment resulted in a decrease in size and number of malignant- and benign-appearing mesorectal nodes on MRI. Nodal downstaging and nodal regression from the mesorectal fascia were observed after treatment. MRI is a useful tool for assessing nodal response to neoadjuvant treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The thin section rock physics: Modeling and measurement of seismic wave velocity on the slice of carbonates

This paper discusses a new approach for investigating the seismic wave velocity of rock, specifically carbonates, as affected by their pore structures. While the conventional routine of seismic velocity measurement highly depends on the extensive laboratory experiment, the proposed approach utilizes the digital rock physics view which lies on the numerical experiment. Thus, instead of using core sample, we use the thin section image of carbonate rock to measure the effective seismic wave velocity when travelling on it. In the numerical experiment, thin section images act as the medium on which wave propagation will be simulated. For the modeling, an advanced technique based on artificial neural network was employed for building the velocity and density profile, replacing image's RGB pixel value with the seismic velocity and density of each rock constituent. Then, ultrasonic wave was simulated to propagate in the thin section image by using finite difference time domain method, based on assumption of an acoustic-isotropic medium. Effective velocities were drawn from the recorded signal and being compared to the velocity modeling from Wyllie time average model and Kuster-Toksoz rock physics model. To perform the modeling, image analysis routines were undertaken for quantifying the pore aspect ratio that is assumed to represent the rocks pore structure. In addition, porosity and mineral fraction required for velocity modeling were also quantified by using integrated neural network and image analysis technique. It was found that the Kuster-Toksoz gives the closer prediction to the measured velocity as compared to the Wyllie time average model. We also conclude that Wyllie time average that does not incorporate the pore structure parameter deviates significantly for samples having more than 40% porosity. Utilizing this approach we found a good agreement between numerical experiment and theoretically derived rock physics model for estimating the effective seismic wave velocity of rock.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of Various Methods for Determining Bulk Compositions of Chondrules and Other Objects in Petrographic Thin Sections

Studies of many objects in petrographic thin section, such as melt inclusions in igneous rocks, chondrules and Ca-Al rich inclusions in chondritic meteorites, or clasts in lunar and other breccias, require or can benefit from knowledge of their bulk compositions. Given the scarcity of these materials, the reluctance of curators to provide more abundant material, and the extreme difficulty of cleanly separating such objects from their rock matrices, geochemical and cosmochemical studies need the ability to determine their bulk compositions from in situ methods, such as defocused beam analysis, or quantitative chemical mapping by electron beam methods.

Ross, Daniel Kent↗

Invasive intraductal papillary mucinous neoplasms of the pancreas: relationships between mural nodules detected on thin-section contrast-enhanced MDCT and invasive components

Purpose: To elucidate the relationships between mural nodules (MNs) and invasive components in patients with invasive intraductal papillary mucinous neoplasm (IPMN) on the basis of thin-section contrast-enhanced multidetector CT (CE-MDCT) and pathologic findings. Methods: This retrospective study included 28 patients with surgically confirmed invasive IPMN. Two radiologists independently evaluated the thin-section (1-mm section thickness, no overlap) triple-phase CE-MDCT images for MNs, invasive components, and the continuity between them using a five-point scale (confidence scores of 1–3 as negative, 4 and 5 as positive). Kappa statistic was used to evaluate interobserver agreement. The CE-MDCT findings were correlated with pathologic findings. Results: Interobserver agreement was good or excellent. MNs consisting of tumor cells were recognized in 12 (42.9%) of 28 patients with no discrepancy between the two radiologists. Invasive components were detected in 85.7% and 82.1% in the pancreatic parenchymal phase for radiologist 1 and 2, respectively, and recognized as hypoattenuating areas. Pathologic continuities between MNs and invasive components were confirmed in five (41.7%) of 12 patients with MNs and these were detected on CE-MDCT. When combined seven patients without continuities between MNs and invasive components and 16 patients without MNs, the invasive components pathologically derived from non-nodular low-height papillary epithelium in 23 (82.1%) of 28 patients. Conclusions: The invasive components derived more often from low-height papillary epithelium without MN appearance on CE-MDCT than from MN. Careful attention should be paid to the existence of an invasive component even in the absence of an enhancing MN.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Citizen Green #1 Well: Quantitative XRD & Thin Section Data

This submission includes information on quantitative x-ray diffraction measurements and thin section photography conducted on sidewall cores from the Citizen Green #1 well drilled on King Island, CA (API 07720688) as part of the WESTCARB partnership basin characterization effort. Cores were acquired with a rotary sidewall tool at a range of depths; only deeper cores were sufficiently consolidated for analysis. SidewallCoreFormationDepthNotes.xls provides details on available samples. Helium porosimetry, air permeability, and brine permeability measurements were conducted on all competent samples (~15). Samples were largely in the Mokelumne, H&T shale, and Starkey formations. All measurements were conducted at Lawrence Berkeley National Laboratory.

Thin Section↗

The properties of thin-section, four-point-contact ball bearings in space

Thin section, four-point-contact ball bearings are increasinly employed in spacecraft mechanisms because of the potential advantages they offer. However, litte was previously known of their torque, thermal conductance and stiffness properties at conditions anticipated for their use in space. An investigation of these properties are described. It was found that frictional (Coulomb) torque, thermal conductance and stiffness all show marked dependence on the bearing preload, the housing design, the bearing external fit (i.e., free fit or interference) and on the thermal gradient across the races. Optimum bearing performance is achieved only if these properties are well understood. The necessary data to understand these properties are provided.

Rowntree, R. A.↗