Determination of the heat capacities of Lithium/BCX (bromide chloride in thionyl chloride) batteries

Heat capacities of twelve different Lithium/BCX (BrCl in thionyl chloride) batteries in sizes AA, C, D, and DD were determined. Procedures and measurement results are reported. The procedure allowed simple, reproducible, and precise determinations of heat capacities of industrially important Lithium/BCX cells, without interfering with performance of the cells. Use of aluminum standards allowed the accuracy of the measurements to be maintained. The measured heat capacities were within 5 percent of calculated heat capacity values.

Kubow, Stephen A.↗

Chloride Salt Purification by Reaction With Thionyl Chloride Vapors to Remove Oxygen, Oxygenated Compounds, and Hydroxides

Molten chloride salts (including MgCl 2 , KCl, NaCl, and ZnCl 2 ) are being considered for heat transfer media for renewable (solar) and nuclear power generators, as fuel carrier for nuclear reactors, and as thermal energy storage media. Impurities such as oxygen, hydroxides, moisture, and sulfur are known to negatively influence the corrosion of materials in contact with the salt (e.g., structural metals). Commercially available chloride salts come with a range of impurities. Before using the chloride salts at high temperature, it is desirable to remove the impurities to increase the performance of the salt and reduce corrosion. In this study, we tested the use of thionyl chloride vaporized into a stream of argon to react with oxygenated impurities in a mixture of MgCl 2 -KCl-NaCl, removing them as HCl and SO 2 . The reagent was bubbled through the salt when both above and below the melting point. The reaction was followed using thermocouple data from the salt and by Fourier transform infrared (FTIR) spectroscopy on the exhaust of the reactor. The reaction kinetics were followed by comparing the peaks from SO 2 product to SOCl 2 reagent in the FTIR spectra. The purity of the salt was assessed at the end of the purification process by x-ray diffraction and inductively coupled plasma analysis. Although the process was effective in removing the oxygen content of the mixture, ternary compounds were formed in the process, including KNiCl 3 and KMgCl 3 . The nickel in KNiCl 3 came from the reaction between the salt and the nickel vessel. Thus, these experiments suggest that improvements to the process must be made before using SOCl 2 vapors for the purification of chloride salts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of lithium-thionyl chloride batteries for Centaur

Lithium thionyl chloride (LiSOCl2) primary cells and batteries have received considerable attention over the last several years because of their high theoretical specific energy and energy density. The objective was to develop a 300 wh/kg cell capable of safe operation at C/2 rate and active storage life for 5 to 10 years. This technology would replace other primary cell technologies in NASA applications mainly the silver zinc (AgZn) batteries presently in use. The LiSOCl2 system exceeds the capabilities of the AgZn in terms of specific energy of 300 wh/kg (compared with 100 wh/kg for AgZn), active storage life of 10 to 20 times the 3 to 6 months active storage and has a significantly lower projected cost.

Halpert, Gerald↗

Development of lithium-thionyl chloride batteries for Centaur

Lithium thionyl chloride (LiSOCl2) primary cells and batteries have received considerable attention over the last several years because of their high theoretical specific energy and energy density. The objective was to develop a 300 wh/kg cell capable of safe operation at C/2 rate and active storage life for 5 to 10 years. This technology would replace other primary cell technologies in NASA applications mainly the silver zinc (AgZn) batteries presently in use. The LiSOCl2 system exceeds the capabilities of the AgZn in terms of specific energy of 300 wh/kg (compared with 100 wh/kg for AgZn), active storage life of 10 to 20 times the 3 to 6 months active storage and has a significantly lower projected cost.

Halpert, Gerald↗

Development of a 300 Amp-hr high rate lithium thionyl chloride cell

The development of a high-rate lithium thionyl chloride cylindrical cell with parallel plate electrodes is discussed. The development was divided into three phases: phase 1, a 150 Amp/hour low rate (1 mA/sq cm) design; phase 2, a 25 Amp/hour high rate (5 mA/sq cm) design; and phase 3, a 300 Amp/hour high rate (5 mA/sq cm) design. The basic design is the same for all three cells. The electrodes are perpendicular to the axis of the cylinder. Multiple electrodes are bussed up the side of the cylinder, 180 deg apart allowing excellent anode and cathode utilization. It is a lithium limited design with excess electrolyte. The cathode is Shawinigan or Gulf Acetylene black with no catalyst. The electrolyte is 1.8 Molar lithium tetrachloroaluminate (LiAlCl4) in thionyl chloride. All cell cases are 304L Stainless Steel with a BS&B burst disc.

Boyle, Gerard H.↗

Low temperature safety of lithium-thionyl chloride cells

The use of lithium thionyl chloride cells for low-temperature applications is presently restricted because of their unsafe behavior. An attempt is made in the present investigation to identify the safe/unsafe low temperature operating conditions and to understand the low temperature cell chemistry responsible for the unsafe behavior. Cells subjected to extended reversal at low rate and -40 C were found to explode upon warm-up. Lithium was found to deposit on the carbon cathodes during reversal. Warming up to room temperature may be accelerating the lithium corrosion in the electrolyte. This may be one of the reasons for the cell thermal runaway.

Subbarao, S.↗

Hazards of lithium thionyl chloride batteries

Two different topics which only relate in that they are pertinent to lithium thionyl chloride battery safety are discussed. The first topic is a hazards analysis of a system (risk assessment), a formal approach that is used in nuclear engineering, predicting oil spills, etc. It is a formalized approach for obtaining assessment of the degree of risk associated with the use of any particular system. The second topic is a small piece of chemistry related to the explosions that can occur with lithium thionyl chloride systems. After the two topics are presented, a discussion is generated among the Workshop participants.

Parry, J. M.↗

A high power lithium thionyl chloride battery for space applications

A high power, 28 V, 330 A h, active lithium thionyl chloride battery has been developed for use as main and payload power sources on an expendable launch vehicle. Nine prismatic cells, along with the required electrical components and a built-in heater system, are efficiently packaged resulting in significant weight savings over presently used silver-zinc batteries. The high rate capability is achieved by designing the cells with a large electrochemical surface area and impregnating an electrocatalyst, polymeric phthalocyanine, into the carbon cathodes. Passivation effects are reduced with the addition of sulfur dioxide into the thionyl chloride electrolyte solution. The results of conducting a detailed thermal analysis are utilized to establish the heater design parameters and the thermal insulation requirements of the battery. An analysis of cell internal pressure and vent characteristics clearly illustrates the margins of safety under different operating conditions. Performance of fresh cells is discussed using polarization scan and discharge data at different rates and temperatures. Self-discharge rate is estimated based upon test results on cells after storage. Results of testing a complete prototype battery are described.

Shah, Pinakin M.↗

Case-positive versus case-negative designs for low-rate lithium thionyl chloride cells

Case polarity design choices are discussed. Two examples of case-negative designs are presented. One battery is thionyl chloride limited and the other is lithium limited. The case-positive design is thionyl chloride limited. It is found that the case-positive/case-negative design consideration does not seem to have much bearing on storage. However, during low rate discharge, the case-negative cells show a steadily decreasing capacity as you go to lower and lower rates.

Mahy, T. X.↗

Lithium thionyl chloride high rate discharge

Improvements in high rate lithium thionyl chloride power technology achieved by varying the electrolyte composition, operating temperature, cathode design, and cathode composition are discussed. Discharge capacities are plotted as a function of current density, cell voltage, and temperature.

Klinedinst, K. A.↗

Safety considerations of lithium-thionyl chloride cells

The use of spirally wound lithium-thionyl chloride (Li-SOCl2) cells is currently limited because of their hazardous behavior. Safety hazards have ranged from mild venting of toxic materials to violent explosions and fires. These incidents may be related to both user- and manufacturer-induced causes. Many explanations have been offered to explain the unsafe behavior of the cells under operating and abuse conditions. Explanations fall into two categories: (1) thermal mechanisms, and (2) chemical mechanisms. However, it is quite difficult to separate the two. Both may be responsible for cell venting or explosion. Some safety problems encountered with these cells also may be due to design deficiencies and ineffective quality control during cell fabrication. A well-coordinated basic and applied research program is needed to develop safe Li-SOCl2 cells. Recommendations include: (1) learnig more about Li-SOL2 cell chemistry; (2) modeling cell and battery behavior; (3) optimizing cell design for safety and performance, (4) implementing quality control procedures; and (5) educating users.

Subbarao, Surampudi↗

Electrical, thermal and abusive tests on lithium thionyl chloride cells

Electrical characterizations, thermal characterizations, and outer limits tests of lithium thionyl chloride cells are discussed. Graphs of energy density vs power density and heat rate vs time are presented along with results of forced reversal and high rate discharge tests.

Frank, H. A.↗

Investigation of an Aberrant Cell Voltage During the Filling of a Large Lithium Thionyl Chloride Cell

The investigation of an aberrant cell voltage during the filling of a large lithium thionyl chloride cell summary is at: an aberrant voltage trace was noted during the review of cell filling data; incident was traced to an interruption during filling; experimentation suggested oxidizable sites within the carbon electrode were responsible for the drop in voltage; the voltage anomaly could be reproduced by interrupting the filling of similar cells; and anomalous voltage dip was not due to a short.

Thaller, Lawrence H.↗

Identification and time evolution of thionyl chloride (SOCl 2 ) radiolysis products

In this study, innovative solutions are needed to reduce the amount of high-level waste generated by used nuclear fuel recycling strategies to support the widespread adoption of sustainable nuclear fission energy technologies. To this end, a new sulfur chloride-based process has been developed to recycle zirconium alloy-based materials, which make up a significant fraction of high-level radioactive waste. To support the continued development of this process, we present new data on the potential reaction pathways over time of the products arising from the gamma and electron beam radiolysis of neat thionyl chloride (SOCl 2 ). Interrogation of the gamma irradiated liquid by Raman spectroscopy provided more conclusive identification of the SOCl 2 degradation products, specifically sulfur dichloride (SCl 2 ), molecular chlorine (Cl 2 ), sulfur dioxide (SO 2 ), and sulfuryl chloride (SO 2 Cl 2 ). In comparison, the high dose rate (~10 7 Gy s -1 ) electron beam irradiations formed significantly more degradation products. For both cobalt-60 gamma and electron beam irradiations, the observed degradation products were found to evolve as a function of time post-irradiation via the same reaction pathways, with indication of a solvent regeneration mechanism. These findings are fortuitous for process development, as such a mechanism would be beneficial for process longevity and cost effectiveness.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Performance of (CoPC)n catalyst in active lithium-thionyl chloride cells

An experimental study was conducted with anode limited D size cells to characterize the performance of an active lithium-thionyl chloride (Li/SOCl2) system using the polymeric cobalt phthalocyanine, (CoPC)n, catalyst in carbon cathodes. The author describes the results of this experiment with respect to initial voltage delays, operating voltages, and capacities. The effectiveness of the preconditioning methods evolved to alleviate passivation effects on storage are also discussed. The results clearly demonstrated the superior high rate capability of cells with the catalyst. The catalyst did not adversely impact the performance of cells after active storage for up to 6 months, while retaining its beneficial influences.

Shah, Pinakin M.↗

Evaluation of high-energy lithium thionyl chloride primary cells

An advanced commercial primary lithium cell (LiSoCl2) was evaluated in order to establish baseline data for improved lithium batteries for aerospace applications. The cell tested had nominal capacity of 6 Ah. Maximum energy density at low rates (less than C/30, where C is the cell capacity in amp-hrs and 30 corresponds to a 30 hr discharge time) was found to be near 300 Wh/kg. An equation which predicts the operating voltage of these cells as a function of current and state of charge is presented. Heat generation rates of these cells were determined as a function of current in a calorimeter. It was found that heat rates could be theoretically predicted with some degree of accuracy at currents less than 1 amp or the C/6 rate. No explosions were observed in the cells during the condition of overdischarge or reversal nor during high rate discharge. It was found, however, that the cells can vent when overdischarge currents are greater than C/30 and when discharge rates are greater than 1.5C.

Frank, H. A.↗

Heat generation rates in lithium thionyl chloride cells

An empirical equation that is useful for good first approximation in thermal modeling is presented. Indications and measurements of electrochemical heat effects were investigated. The particular cells of interest are of the D size, with spiral wound configuration and were instrumented with a thermocouple. It is found that cathode limited cells can explode on reversal at moderate temperatures.

Frank, H.↗

Discharge of 1400 AH lithium thionyl chloride cells into voltage reversal

The development of a high energy density battery is discussed. Tests were conducted on a 1400 AH cell and they include: drop tests, crush tests, vibration and shock tests, hydrostatic pressure effects, charge current tests, and discharge tests. None of these tests led to a venting or explosion of the cell. Criteria are presented for extending RV safety of a 1400 AH cell.