Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thomson”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Dual-pass upgrade to the Thomson scattering diagnostic on the Prototype-Material Plasma Exposure eXperiment (Proto-MPEX)

The Thomson scattering (TS) diagnostic on the Prototype-Material Plasma Exposure eXperiment has been upgraded to measure electron temperature (T e ) and density (n e ) simultaneously at two axial locations. After the first pass through the vacuum vessel, the exiting laser beamline is re-collimated in the atmosphere and rerouted into the vacuum vessel for the second pass. The upgrade will help diagnose axial T e and n e gradients between the “central chamber” and the target region which are located 1 m and 2.5 m, respectively, downstream from the Helicon radio-frequency source. The TS measurements have given T e ≈ 4–15 eV and n e ≈ 2–4 × 10 19 m -3 at the central chamber and T e ≈ 1–2 eV and n e ≈ 1–2 × 10 19 m -3 at the target region. The upgrade also increases the number of sampling points at the target region from 3 fibers to 5 fibers, measuring 3 cm radially across the plasma column, and 25 fibers in the central chamber, radially spanning 8 cm. The intensified CCD camera is double triggered for each laser pulse in order to measure (1) the TS and laser stray light and (2) the plasma background light that contains nuisance emission lines and bremsstrahlung. Subtracting the background light from the TS photons improves the temperature and density measurements. Details of the diagnostic setup, axial and radial measurements, and areas for further optimization are discussed.

dual-pass Thomson Scattering↗

Portable diagnostic package for Thomson scattering and optical emission spectroscopy on Princeton field-reversed configuration 2 (PFRC 2)

An Advanced Research Projects Agency-Energy funded diagnostic system has been deployed to the Princeton field-reversed configuration 2 (PFRC-2) device, located at Princeton Plasma Physics Laboratory. The Portable Diagnostic Package (PDP), designed at Oak Ridge National Laboratory, allows for the measurement of Thomson Scattering (TS) for electron density and temperature and Optical Emission Spectroscopy (OES) for ion temperature, impurity density, and ion velocity. A tunable spectrometer on the PDP with three gratings provides the flexibility to measure low (1 eV) and high (1000 eV) electron temperature ranges from TS. Additionally, using a second spectrometer, the OES diagnostic can survey light emission from various ion excitation levels for wide wavelength ranges. The electron density (<2 × 10 19 m –3 ) of plasmas generated in PFRC-2 has been below the PDP TS discrimination threshold, which has made TS signal detection challenging against a high-background of laser stray light. The laser stray light was iteratively reduced by making modifications to the entrance and exit geometry on PFRC-2. Rayleigh scattering experiments on PFRC have yielded the TS discrimination sensitivity to be >1 × 10 20 m –3 for the PDP. A recently implemented narrow-band notch spectral filter that masks the second harmonic 532 nm Nd:YAG laser wavelength has increased the system’s TS light discrimination sensitivity 65 times compared to the instance when the notch filter was not implemented. The hardware implementation including design changes to the flight tubes and Brewster windows will be discussed, along with results from Rayleigh and rotational Raman scattering sensitivity analyses, which were used to establish a quantitative figure of merit on the system performance. Further, the Raman scattering calibration with the notch filter has improved the PDP electron density threshold to 1 ± 0.5 × 10 18 m –3 .

47 OTHER INSTRUMENTATION↗

Design and implementation of a portable diagnostic system for Thomson scattering and optical emission spectroscopy measurements

A diagnostic system, which has a design goal of high-portability, has been designed at Oak Ridge National Laboratory (ORNL). This project aims at providing measurements of key plasma parameters (ne, Te, ni, Ti) for fusion-relevant devices, utilizing Thomson scattering (TS) and optical emission spectroscopy (OES). The innovative design employs mostly commercial off-the-shelf instrumentation and a traveling team of researchers to conduct measurements at various magnetic-confinement plasma devices. The TS diagnostic uses a Quantel Q-smart 1500 Nd:YAG laser with a 2ω harmonic generator to produce up to 850 mJ of 532 nm laser pulses at 10 Hz. Collection optics placed at the detection port consists of an 11 × 3 optical fiber bundle, where the TS diagnostic uses an 11 × 1 subset array of the fibers, the OES diagnostic uses another 11 fibers, and the remaining fibers are available to the host institution. The detection system is comprised of two separate IsoPlane-320 spectrometers with triple-grating turrets of various line spacing and two PI-MAX 4 intensified CCD detectors, used simultaneously to measure a broad range of ion, impurity, and electron parameters. The self-contained diagnostic package also includes a data processing and storage system. The design and initial implementation of the TS-OES diagnostic system are described. The experiments from the proof-of-principle operation of the portable package on a high density (∼2.5 × 1022 m−3) and low-temperature (∼5 eV) electrothermal arc source at ORNL are also discussed.

Kafle, N. (ORCID:000000028144787X)↗

Implementation of a portable diagnostic system for Thomson scattering measurements on an electrothermal arc source

To fulfill the increasing needs of diagnostic support for researchers in plasma technology, a portable diagnostic package (PDP) equipped for both laser Thomson scattering (TS) and optical emission spectroscopy has been designed and constructed at Oak Ridge National Laboratory (ORNL), aiming to measure the temperature and number density of electrons and temperatures of ions in plasma devices. The PDP has been initially implemented on a high density and low temperature electrothermal arc source (ET-arc) at ORNL to test its TS capability. TS from the plasmas in the ET-arc has been obtained using the PDP. The electron temperature and number density were determined from TS spectra. These results were then compared to measurements from previous studies on the ET-arc. The TS diagnostic measured 0.8 ± 0.1, 1.3 ± 0.2, and 0.7 ± 0.1 eV and (4.4 ± 0.5) × 1021, (5.9 ± 0.7) × 1021, and (4.3 ± 0.5) x 1021 m-3, respectively, from three lines of sight that transect the plasma column.

He, Z. (ORCID:0000000183159882)↗

Enhancing Thomson scattering polychromator performance with multi-pass spectral filters

In photon-deficient, noncollective Thomson scattering diagnostics, filter polychromators are typically employed in the spectral analysis of Thomson-scattered signals to achieve acceptable signal-to-noise performance. Currently, the most common polychromator filter configuration employs a set of single-passband optical filters that define individual spectral channels. Here, we introduce a new spectral analysis method for Thomson scattering based on spectral filters with multiple passbands, referred to as Thomson scattering spectral multiplexing. Implementing multi-bandpass spectral filters on polychromators increases the achievable range of electron temperature measurement for a given number of filters employed. In addition, Thomson scattering spectral multiplexing reduces systematic measurement uncertainty, with fewer required spectral channels, thereby decreasing light loss from reduced optical element interactions. A multi-bandpass filter set, optimized by a genetic algorithm, has been successfully installed and tested on the Helically Symmetric eXperiment (HSX), demonstrating the benefits of the Thomson scattering spectral multiplexing method.

Instruments & Instrumentation↗

Mitigation of self-focusing in Thomson scattering experiments

A fundamental challenge associated with measuring Thomson scattering comes from the small scattering cross section associated with the interaction. Here, to improve photon statistics a powerful Thomson-scattering probe laser is required. Ponderomotive self-focusing limits the maximum power in the Thomson-scattering probe and was shown to limit the maximum achievable Thomson-scattering signal-to-noise ratio. Operating the laser at powers above the self-focusing critical power was shown to cause beam degradation, which reduced the amount of collected Thomson-scattered light. Using a phase plate was shown to improve laser beam propagation, and consequently improve the signal-to-noise ratio in the measured spectrum.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simultaneous measurements of forward Thomson scattering and rotational Raman scattering in a weakly ionized plasma

This paper demonstrates a simultaneous Thomson scattering and rotational Raman scattering spectroscopy in a weakly ionized plasma in air. Thomson scattering was collected in the forward scattering direction, in order to compress the relative spectra width of Thomson scattering from the plasma. Simultaneous measurements of rotational Raman scattering were obtained in the same direction, which was not affected by the collection angles. The measurements thus yielded electron temperature (T e ) and electron number density (n e ) as well as gas temperature in a weakly ionized atmospheric pressure plasma. The separation of rotational Raman scattering and Thomson scattering occurred when the scattering angle decreased to 20 degrees in the plasma, where the air temperature was found to be 150 ± 25 °C, and electron temperature of the plasma was 0.587 ± 0.087 eV, and electron number density was (1.608 ± 0.416) × 1021 m-3. The technique could be used for various plasma and combustion diagnostics in realistic engineering environments.

He, Zichen (ORCID:0000000183159882)↗

5ω Optical Thomson Scattering Report

The 5ω Optical Thomson Scattering system on the National Ignition Facility (NIF) is a diagnostic designed to measure temporally and spatially resolved plasma conditions in Inertial Confinement Fusion (ICF) Hohlraums. The system was proposed in 2014 and a phased approach to implementation was developed. In phase one the collection system was designed, built, and fielded on the NIF to be used for 3ω Thomson scattering measurements and background measurements near 211 nm (5ω. The initial commissioning experiment for the collection system was completed in Oct. 2016. Commissioning of the collection system continued through 2017 and the system is now fielded for a range of user experiments and regularly produces publication quality data. A dedicated 5ω probe laser was designed and built to allow Thomson scattering measurements in the presence of 2 MJ of 3ω drive energy. Due to scattered light (spectral reflections, laser-plasma instabilities, and unconverted drive energy) from the 3w drive lasers typical wavelengths (2ω and 4ω) fielded at other laser facilities like the Nova Laser Facility and the Omega Laser Facility were unable to meeting the signal to background requirements in design studies. A 10 Joule 5ω probe was proposed as a solution that met requirements. This 10 Joule laser was more energetic than previously fielded 5w lasers by 2-3 orders of magnitude. As part of a risk reduction plan, phase two of the project was to develop a 1 Joule, 5ω laser to demonstrate conversion efficiency >20% from 1ω to 5ω and make initial Thomson scattering measurements in the first few nanoseconds of an ICF laser pulse. Initial tests of the 5w conversion were completed at the Laboratory for Laser Energetics (LLE) and produced record 5ω energies. Based on these results from LLE, a 1 Joule, 5w laser system was designed for the NIF in 2018 and commissioning began in 2019. Commissioning of the 5ω laser system continued through 2023 and was eventually paused in Q1 of FY24 due to completing resource constraints. Commissioning of the 5w laser system proved incredibly challenging. Multiple issues were identified during commissioning and resolved, but issues remain. Currently there is not a clear understanding of why 5ω scattered has not been detected on the OTS collection system. Based on offline measurements, calculations, and preshot measurements the system appears to meet all requirements. Potential target physics issues have been investigated and do not appear to be an issue. The current hypothesis is that there is an error in one or more aspects of the offline testing not translating to expected performance when the system is fielded on the NIF. Additional full system testing in-situ utilizing the complete OTS system and NIF target chamber center time is needed to further test potential failure modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Statistical analysis of non-Maxwellian electron distribution functions measured with angularly resolved Thomson scattering

Angularly resolved Thomson scattering is a novel extension of Thomson scattering, enabling the measurement of the electron velocity distribution function over many orders of magnitude. Here, details of the theoretical basis of the technique and the instrument designed for this measurement are described. Angularly resolved Thomson-scattering data from several experiments are shown with descriptions of the corresponding distribution functions. A reduced model describing the distribution function is given and used to perform a Monte Carlo analysis of the uncertainty in the measurements. The electron density and temperature were determined to a precision of 12% and 21%, respectively, on average, while all other parameters defining the distribution function were generally determined to better than 20%. It was found that these uncertainties were primarily due to limited signal to noise and instrumental effects. Furthermore, measurements with this level of precision were sufficient to distinguish between Maxwellian and non-Maxwellian distribution functions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Free space Thomson scattering to study high energy density shocks

A free space collective Thomson scattering system has been developed to study pulsed power produced plasmas. While most Thomson scattering diagnostics on pulsed power machines use a bundle of fibers to couple scattered light from the plasma to the spectrometer, this system used free space coupling of the light, which enabled a spatially continuous image of the plasma. Initial experiments with this diagnostic were performed on an inverse wire array generated by a 200 kA, 1100 ns rise time pulse power generator. The capabilities of this diagnostic were demonstrated by using the low frequency ion acoustic wave feature of the Thomson scattering spectra to measure the plasma flow velocity. The diagnostic was demonstrated to measure velocities between 20 and 40 km/s with an error of 4.7 km/s when fitting with a 600 μm spatial resolution or 8.9 km/s when fitting with a 150 μm spatial resolution. In some experiments, the diagnostic observed a bow shock in the plasma flow as the scattering intensity increased and flow velocity decreased.

47 OTHER INSTRUMENTATION↗

Probing local electron temperature and density inside a sheared flow stabilized Z-pinch using portable optical Thomson scattering

We report the first optical Thomson scattering measurements inside a high electron temperature (≳1 keV) and moderate electron density (mid 10 16 cm –3 ) plasma. This diagnostic has been built to provide critical plasma parameters, such as electron temperature and density, for Advanced Research Projects Agency-Energy-supported fusion-energy concepts. It uses an 8 J laser at 532 nm in 1.5 ns to measure the high frequency feature of the Thomson scattering profile at 17 locations along the probe axis. It is able to measure electron density from 5 × 10 17 cm –3 to several 10 19 cm –3 and electron temperatures from tens of eV to several keV. Here, in this paper, we describe the design, deployment, and analysis on the sheared flow stabilized Z-pinch machine at Zap Energy named FuZE. The probe beam is aimed at an axial distance of 20 cm from the central electrode and is timed within the temporal envelope of neutron emission. The high temperature and moderate density plasmas generated on FuZE lie in an unconventional regime for Thomson scattering as they are between tokamaks and laser-produced plasmas. We described the analysis considerations in this regime, show that the electron density was below 5 × 10 16 cm –3 at all times during these measurements, and present a sample shot where the inferred electron temperature varied from 167 ± 16 eV to 700 ± 85 eV over 1.6 cm.

47 OTHER INSTRUMENTATION↗

Stable and tunable MeV $$\gamma$$-ray generation via dual-laser inverse Thomson scattering from a laser-plasma accelerator

Abstract Inverse Thomson scattering from laser-plasma accelerators offers a pathway to compact, tunable MeV $$\gamma$$ -ray sources for reduced-dose radiography and enhanced performance in nuclear resonance fluorescence (NRF)-based isotope identification. However, photon yield and spectral quality are often limited by constraints on interaction geometry and scatter-laser tunability. Here we demonstrate a MeV $$\gamma$$ -ray source based on a dual-laser inverse Thomson scattering configuration driven by a 100-TW laser-plasma accelerator. Electron beams tunable from 122 to 204 MeV with $$<5$$ mrad divergence and $$<1$$ mrad pointing stability generate $$\gamma$$ rays with peak energies from 276 keV to 1.2 MeV and yields up to $$2\times 10^{7}$$ photons per shot. By independently controlling the interaction position and the scatter-pulse duration, we experimentally match the scatter pulse to the walk-off-limited interaction length. Extending the scatter pulse to 200 fs increases photon production by approximately $$15\%$$ while maintaining operation in the linear Thomson regime, thereby preserving narrow spectral bandwidth and controlled radiation divergence. Radiographic characterization demonstrates MeV-level penetration and $$\approx 0.1$$ mm spatial resolution, while stable operation is sustained over multi-hour timescales across multiple days. These results show that interaction-length optimization provides a scalable strategy for improving photon yield, spectral control, and operational stability in compact laser-plasma-accelerator-driven $$\gamma$$ -ray sources.

Tsai, Hai-En↗

Design and implementation of a Thomson parabola for fluence dependent energy-loss measurements at the Neutralized Drift Compression eXperiment

The interaction of ion beams with matter includes the investigation of the basic principles of ion stopping in heated materials. An unsolved question is the effect of different, especially higher, ion beam fluences on ion stopping in solid targets. This is relevant in applications such as in fusion sciences. To address this question, a Thomson parabola was built for the Neutralized Drift Compression eXperiment (NDCX-II) for ion energy-loss measurements at different ion beam fluences. The linear induction accelerator NDCX-II delivers 2 ns short, intense ion pulses, up to several tens of nC/pulse, or 1010-1011 ions, with a peak kinetic energy of ~1.1 MeV and a minimal spot size of 2 mm FWHM. For this particular accelerator, the energy determination with conventional beam diagnostics, for example, time of flight measurements, is imprecise due to the non-trivial longitudinal phase space of the beam. In contrast, a Thomson parabola is well suited to reliably determine the beam energy distribution. The Thomson parabola differentiates charged particles by energy and charge-to-mass ratio, through deflection of charged particles by electric and magnetic fields. During first proof-of-principle experiments, we achieved to reproduce the average initial helium beam energy as predicted by computer simulations with a deviation of only 1.4%25. Successful energy-loss measurements with 1 μm thick silicon nitride foils show the suitability of the accelerator for such experiments. The initial ion energy was determined during a primary measurement without a target, while a second measurement, incorporating the target, was used to determine the transmitted energy. The energy-loss was then determined as the difference between the two energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measuring heat flux from collective Thomson scattering with non-Maxwellian distribution functions

Here, heat flux was measured in coronal plasmas using collective Thomson scattering from electron-plasma waves. A laser-produced plasma from a planar aluminum target created a temperature gradient along the target normal. Thomson scattering probed electron-plasma waves in the direction of the temperature gradient with phase velocities relevant to heat flux. The heat-flux measurements were reduced from classical values inferred from the measured plasma conditions in regions with large temperature gradients and agreed with classical values for weak gradients. In regions where classical theory was invalid, the heat flux was determined by reproducing the measured Thomson-scattering spectra using electron distribution functions consistent with nonlocal thermal transport. Lastly, full-scale hydrodynamic simulations using flux-limited thermal transport ( FLASH ) and the multigroup nonlocal Schurtz, Nicolai, and Busquet (SNB) models both underestimated the heat flux at all locations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron plasma wave Thomson scattering on laboratory plasma jets

Plasma jets created from a 15 lm thick Al foil on a 1 MA pulsed power machine were studied using a new electron plasma wave (EPW) Thomson scattering system in conjunction with previously developed ion acoustic wave (IAW) Thomson scattering and interferometry. These diagnostics give multiple ways of measuring the electron temperature and density of the jet. Analysis of the EPW feature found the on-axis density of the jet to be between 5 X 10 18 and 1.4 X 10 19 cm -3 , which either matched or was higher than interferometry measurements. Outside of the jet, both of these diagnostics measured a density of 7 X 10 17 cm -3 . On one shot, the EPW spectral feature showed two pairs of peaks within a 250 lm scattering length on the edge of the jet, which shows that the boundary of the jet ~1 mm radius jet is 0.1 mm. While electron temperature measurements of the plasma jet are complicated by the probe beam producing inverse bremsstrahlung heating of the jet, comparison of the electron temperature measured between IAW and EPW Thomson scattering showed the EPW feature to imply significantly higher electron temperatures than the IAW feature (e.g., 160 eV vs 70 eV in one case). Various sources of this discrepancy (for example, density gradients, collisions, and a lag in ionization) and their impact on the plasma are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extended Rice–Thomson analysis and atomistic simulations revealing grain boundary effects on fracture in refractory high-entropy alloys

Significance This work serves to extend the fundamental ductile vs. brittle fracture theory, specifically the Rice–Thomson criterion, by introducing a grain boundary ahead of an initiating crack which propagates at an oblique angle to impinge the boundary. Atomistic fracture simulations on two refractory complex concentrated alloys, the brittle NbMoTaW and the ductile Nb 45 Ta 25 Ti 15 Hf 15 , demonstrate qualitative correspondence with the extended Rice–Thomson criterion and experimental observations. Abstract Understanding how grain boundaries mediate fracture remains a critical challenge in designing ductile, high-performance refractory alloys. Here, we extend the Rice–Thomson criterion to account for the angle between cracks and the impinging grain boundaries (GBs), capturing the competition between intergranular fracture and dislocation-mediated plasticity. Using machine learning interatomic potentials, we performed molecular statics simulations to probe fracture mechanisms in nanocrystalline NbMoTaW and Nb 45 Ta 25 Ti 15 Hf 15 , each with two different grain sizes, revealing trends consistent with experimental observations and the extended Rice model. Comparison with averaged R-curves for bulk samples demonstrates that GBs enhance ductility in Nb 45 Ta 25 Ti 15 Hf 15 in both grain sizes investigated. In contrast, GBs only locally improve fracture resistance in NbMoTaW when cracks are temporarily pinned at GBs inclined at high angles from the crack, but generally promote brittle intergranular fracture. These contrasting behaviors are attributed to differences in GB cohesion, reflecting clear alloying trends that align with ab-initio calculations and trends observed experimentally. Our results bridge classical fracture theory, atomistic simulations, and experimental observations, providing a comprehensive understanding of the fracture mechanisms in nanocrystalline refractory complex concentrated alloys.

36 MATERIALS SCIENCE↗

Investigation of picosecond thermodynamics in a laser-produced plasma using Thomson scattering

The picosecond evolution of the plasma conditions in a laser-produced plasma was measured using a Thomson-scattering diagnostic. The picosecond resolved Thomson spectra was enabled by a pulse-front-tilt-compensated spectrometer. The Thomson spectra revealed a transition in the plasma conditions from an initially cold evolving plasma to a quasi-stationary equilibrium plasma. The equilibrium temperature was found to match the generalized heat equation's predicted scaling ${T}_{e}\propto {n}_{e}^{2/5}$ and ${T}_{e}\propto {I}^{1/5}$. Here, the plasma evolution was compared to Raman gain bandwidth calculations and showed a time-dependent resonance detuning that would limit the transfer efficiency of a Raman plasma amplifier in the linear regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗