At least 19 records

Streak camera time calibration procedures

Time calibration procedures for streak cameras utilizing a modulated laser beam are described. The time calibration determines a writing rate accuracy of 0.15% with a rotating mirror camera and 0.3% with an image converter camera.

Long, J.↗

Timing Calibration of the NuSTAR X-Ray Telescope

The Nuclear Spectroscopic Telescope Array (NuSTAR) mission is the first focusing X-ray telescope in the hard X-ray (3–79 keV) band. Among the phenomena that can be studied in this energy band, some require high time resolution and stability: rotation-powered and accreting millisecond pulsars, fast variability from black holes and neutron stars, X-ray bursts, and more. Moreover, a good alignment of the timestamps of X-ray photons to UTC is key for multi-instrument studies of fast astrophysical processes. In this paper, we describe the timing calibration of the NuSTAR mission. In particular, we present a method to correct the temperature-dependent frequency response of the on-board temperature-compensated crystal oscillator. Together with measurements of the spacecraft clock offsets obtained during downlinks passes, this allows a precise characterization of the behavior of the oscillator. The calibrated NuSTAR event timestamps for a typical observation are shown to be accurate to a precision of ∼65 μs.

Matteo Bachetti↗

ICESAT Laser Altimeter Pointing, Ranging and Timing Calibration from Integrated Residual Analysis

On January 12, 2003 the Ice, Cloud and land Elevation Satellite (ICESat) was successfully placed into orbit. The ICESat mission carries the Geoscience Laser Altimeter System (GLAS), which has a primary measurement of short-pulse laser- ranging to the Earth s surface at 1064nm wavelength at a rate of 40 pulses per second. The instrument has collected precise elevation measurements of the ice sheets, sea ice roughness and thickness, ocean and land surface elevations and surface reflectivity. The accurate geolocation of GLAS s surface returns, the spots from which the laser energy reflects on the Earth s surface, is a critical issue in the scientific application of these data. Pointing, ranging, timing and orbit errors must be compensated to accurately geolocate the laser altimeter surface returns. Towards this end, the laser range observations can be fully exploited in an integrated residual analysis to accurately calibrate these geolocation/instrument parameters. ICESat laser altimeter data have been simultaneously processed as direct altimetry from ocean sweeps along with dynamic crossovers in order to calibrate pointing, ranging and timing. The calibration methodology and current calibration results are discussed along with future efforts.

Luthcke, Scott B.↗

ICESat Laser Altimeter Pointing, Ranging and Timing Calibration from Integrated Residual Analysis: A Summary of Early Mission Results

On January 12, 2003 the Ice, Cloud and land Elevation Satellite (ICESat) was successfully placed into orbit. The ICESat mission carries the Geoscience Laser Altimeter System (GLAS), which consists of three near-infrared lasers that operate at 40 short pulses per second. The instrument has collected precise elevation measurements of the ice sheets, sea ice roughness and thickness, ocean and land surface elevations and surface reflectivity. The accurate geolocation of GLAS's surface returns, the spots from which the laser energy reflects on the Earth's surface, is a critical issue in the scientific application of these data Pointing, ranging, timing and orbit errors must be compensated to accurately geolocate the laser altimeter surface returns. Towards this end, the laser range observations can be fully exploited in an integrated residual analysis to accurately calibrate these geolocation/instrument parameters. Early mission ICESat data have been simultaneously processed as direct altimetry from ocean sweeps along with dynamic crossovers resulting in a preliminary calibration of laser pointing, ranging and timing. The calibration methodology and early mission analysis results are summarized in this paper along with future calibration activities.

Scott B Luthcke↗

Real Time Calibration Method for Signal Conditioning Amplifiers

A signal conditioning amplifier receives an input signal from an input such as a transducer. The signal is amplified and processed through an analog to digital converter and sent to a processor. The processor estimates the input signal provided by the transducer to the amplifier via a multiplexer. The estimated input signal is provided as a calibration voltage to the amplifier immediately following the receipt of the amplified input signal. The calibration voltage is amplified by the amplifier and provided to the processor as an amplified calibration voltage. The amplified calibration voltage is compared to the amplified input signal, and if a significant error exists, the gain and/or offset of the amplifier may be adjusted as necessary.

Pedro J Medelius↗

A Synthesis of VIIRS Solar and Lunar Calibrations

The NASA VIIRS Ocean Science Team (VOST) has developed two independent calibrations of the SNPP VIIRS moderate resolution reflective solar bands using solar diffuser and lunar observations through June 2013. Fits to the solar calibration time series show mean residuals per band of 0.078-0.10%. There are apparent residual lunar libration correlations in the lunar calibration time series that are not accounted for by the ROLO photometric model of the Moon. Fits to the lunar time series that account for residual librations show mean residuals per band of 0.071-0.17%. Comparison of the solar and lunar time series shows that the relative differences in the two calibrations are 0.12-0.31%. Relative uncertainties in the VIIRS solar and lunar calibration time series are comparable to those achieved for SeaWiFS, Aqua MODIS, and Terra MODIS. Intercomparison of the VIIRS lunar time series with those from SeaWiFS, Aqua MODIS, and Terra MODIS shows that the scatter in the VIIRS lunar observations is consistent with that observed for the heritage instruments. Based on these analyses, the VOST has derived a calibration lookup table for VIIRS ocean color data based on fits to the solar calibration time series.

Calibrations↗

Radiometer Calibrations: Saving Time by Automating the Gathering and Analysis Procedures

Mr. Abtahi custom-designs radiometers for Mr. Hook's research group. Inherently, when the radiometers report the temperature of arbitrary surfaces, the results are affected by errors in accuracy. This problem can be reduced if the errors can be accounted for in a polynomial. This is achieved by pointing the radiometer at a constant-temperature surface. We have been using a Hartford Scientific WaterBath. The measurements from the radiometer are collected at many different temperatures and compared to the measurements made by a Hartford Chubb thermometer with a four-decimal point resolution. The data is analyzed and fit to a fifth-order polynomial. This formula is then uploaded into the radiometer software, enabling accurate data gathering. Traditionally, Mr. Abtahi has done this by hand, spending several hours of his time setting the temperature, waiting for stabilization, taking measurements, and then repeating for other temperatures. My program, written in the Python language, has enabled the data gathering and analysis process to be handed off to a less-senior member of the team. Simply by entering several initial settings, the program will simultaneously control all three instruments and organize the data suitable for computer analyses, thus giving the desired fifth-order polynomial. This will save time, allow for a more complete calibration data set, and allow for base calibrations to be developed. The program is expandable to simultaneously take any type of measurement from up to nine distinct instruments.

Sadino, Jeffrey L.↗

A new calibration method for time delay standard and its application

A method which is used to measure time delay accurately by using a Type 900-LB slotted line is described. The accuracy for calibrating time delay of a precision coaxial air line Type 900-L is about + or - (0.4 to 0.6)ps, and for coaxial cables with VSWR less than 1.5 and time delay t less than 50ns is about + or - (3 to 5)ps. Theoretical analysis and mathematical derivation of microwave networks in cascade are given. Methods to eliminate the errors which are caused by the discontinuities and the error analysis of the measuring system are presented. Skin effect analysis of the transient characteristic of coaxial transmission line are discussed in detail. Methods to eliminate the errors which result from using the calibrated time delay standard to calibrate time interval measurement instruments are presented. The estimation of errors and formulae for correction of those errors are described.

Su, B. W.↗

Argus: a new instrument for the measurement of the stratospheric dynamical tracers, N2O and CH4

We describe here a new instrument for the simultaneous, in situ measurement of the stratospheric tracer molecules, nitrous oxide (N2O) and methane (CH4). Argus is unique in its small size making it well suited for limited payload atmospheric research platforms. Argus employs second harmonic spectroscopy using tunable lead-salt diode lasers emitting in the mid-infrared. We first explain the Argus design philosophy followed by detailed descriptions of the instrument's optical, mechanical, and thermal sub-systems. Argus employs an in-flight calibration system providing real time calibrations and tightly constrained uncertainty estimates of the returned data. Data analysis is carried out using non-linear least-squares model fits to the acquired second harmonic spectra. A sampling of Argus data acquired on a recent stratospheric research campaign in the Arctic winter is presented.

Methane/analysis↗

Multi-Axis Accelerometer Calibration System

A low-cost, portable, and simplified system has been developed that is suitable for in-situ calibration and/or evaluation of multi-axis inertial measurement instruments. This system overcomes facility restrictions and maintains or improves the calibration quality for users of accelerometer-based instruments with applications in avionics, experimental wind tunnel research, and force balance calibration applications. The apparatus quickly and easily positions a multi-axis accelerometer system into a precisely known orientation suitable for in-situ quality checks and calibration. In addition, the system incorporates powerful and sophisticated statistical methods, known as response surface methodology and statistical quality control. These methods improve calibration quality, reduce calibration time, and allow for increased calibration frequency, which enables the monitoring of instrument stability over time.

Finley, Tom↗

Fixture For Calibrating Pressure Probe

Fixture in form of specially designed clamshell housing enables in situ calibration of pressure transducer mounted in body of pressure probe in wind tunnel. Includes two metal half shells machined with necks and matching cavities, when put together, define larger neck and cavity accommodating probe. Probe secured to bottom half shell by use of clamp before installing top half shell: necessary to follow sequence to protect probe during assembly. Clamshell calibration fixture attached to pressure probe in few minutes, making it possible to calibrate pressure transducer at convenient times. Calibrations performed before and after wind-tunnel runs each day, between runs in event of delays or suspected malfunctions, and essentially any other time, without having to remove probe from wind tunnel.

Ashby, George C., Jr.↗

Remote clocks linked by a fully calibrated two-way timing link

Fully calibrated two-way time transfers between the U.S. Naval Observatory (USNO) and the U.S. Naval Observatory Time Service Substation (NOTSS) have become operational. The calibration method employed was the co-located Earth station method. Results concerning timing, stability, comparison of two-way and Global Positioning System (GPS) timing links, and remote clock contribution to local time scale computation will be presented.

Deyoung, James A.↗

Streak camera based SLR receiver for two color atmospheric measurements

To realize accurate two-color differential measurements, an image digitizing system with variable spatial resolution was designed, built, and integrated to a photon-counting picosecond streak camera, yielding a temporal scan resolution better than 300 femtosecond/pixel. The streak camera is configured to operate with 3 spatial channels; two of these support green (532 nm) and uv (355 nm) while the third accommodates reference pulses (764 nm) for real-time calibration. Critical parameters affecting differential timing accuracy such as pulse width and shape, number of received photons, streak camera/imaging system nonlinearities, dynamic range, and noise characteristics were investigated to optimize the system for accurate differential delay measurements. The streak camera output image consists of three image fields, each field is 1024 pixels along the time axis and 16 pixels across the spatial axis. Each of the image fields may be independently positioned across the spatial axis. Two of the image fields are used for the two wavelengths used in the experiment; the third window measures the temporal separation of a pair of diode laser pulses which verify the streak camera sweep speed for each data frame. The sum of the 16 pixel intensities across each of the 1024 temporal positions for the three data windows is used to extract the three waveforms. The waveform data is processed using an iterative three-point running average filter (10 to 30 iterations are used) to remove high-frequency structure. The pulse pair separations are determined using the half-max and centroid type analysis. Rigorous experimental verification has demonstrated that this simplified process provides the best measurement accuracy. To calibrate the receiver system sweep, two laser pulses with precisely known temporal separation are scanned along the full length of the sweep axis. The experimental measurements are then modeled using polynomial regression to obtain a best fit to the data. Data aggregation using normal point approach has provided accurate data fitting techniques and is found to be much more convenient than using the full rate single shot data. The systematic errors from this model have been found to be less than 3 ps for normal points.

Varghese, Thomas K.↗

A Solar-luminosity Model and Climate

Although the mechanisms of climatic change are not completely understood, the potential causes include changes in the Sun's luminosity. Solar activity in the form of sunspots, flares, proton events, and radiation fluctuations has displayed periodic tendencies. Two types of proxy climatic data that can be related to periodic solar activity are varved geologic formations and freshwater diatom deposits. A model for solar luminosity was developed by using the geometric progression of harmonic cycles that is evident in solar and geophysical data. The model assumes that variation in global energy input is a result of many periods of individual solar-luminosity variations. The 0.1-percent variation of the solar constant measured during the last sunspot cycle provided the basis for determining the amplitude of each luminosity cycle. Model output is a summation of the amplitudes of each cycle of a geometric progression of harmonic sine waves that are referenced to the 11-year average solar cycle. When the last eight cycles in Emiliani's oxygen-18 variations from deep-sea cores were standardized to the average length of glaciations during the Pleistocene (88,000 years), correlation coefficients with the model output ranged from 0.48 to 0.76. In order to calibrate the model to real time, model output was graphically compared to indirect records of glacial advances and retreats during the last 24,000 years and with sea-level rises during the Holocene. Carbon-14 production during the last millenium and elevations of the Great Salt Lake for the last 140 years demonstrate significant correlations with modeled luminosity. Major solar flares during the last 90 years match well with the time-calibrated model.

Perry, Charles A.↗

Calibrated Ancillary System (CAS) user's guide, volume 3

The Calibrated Ancillary System (CAS) provides real-time calibrated parameters from the orbiter downlink (ancillary data) to the Goddard Space Flight Center (GSFC). This user's guide contains the introduction to the equipment, operation, general procedures, and specific procedures of the CAS. Volume 3 describes logging and delogging procedures, real-time procedures, and error messages.

Source record↗

Calibrated Ancillary System (CAS) user's guide, volume 1

The Calibrated Ancillary System (CAS) provides real-time calibrated parameters from the orbiter downlink (ancillary data) to the Goddard Space Flight Center (GSFC). This user's guide contains the introduction to the equipment, operation, general procedures, and specific procedures of the CAS. Volume 1 includes a general overview of the CAS relationships with other equipment, physical design, and hardware and software subsystems. In addition, a description of the user levels and tasks, an introduction to CAS operation, and an outline of general operating procedures are included.

Source record↗

Calibrated Ancillary System (CAS) user's guide, volume 2

The Calibrated Ancillary System (CAS) provides real-time calibrated parameters from the orbiter downlink (ancillary data) to the Goddard Space Flight Center (GSFC). This user's guide contains the introduction to the equipment, operation, general procedures, and specific procedures of CAS. Volume 2 describes the central status and control (CSAC) procedures, supervisor procedures, and logging procedures.

Source record↗

Calibrated Ancillary System (CAS) user's guide, volume 4

The Calibrated Ancillary System (CAS) provides real-time calibrated parameters from the orbiter downlink (ancillary data) to the Goddard Space Flight Center (GSFC). This user's guide contains the introduction to the equipment, operation, general procedures, and specific procedures of the CAS. Volume 4 presents the GSFC user mission planning procedures covering the mission planning main menu, bulletin board system, ancillary products menu, utility menu procedures, and ancillary support files procedures.

Source record↗