Search NASASearch

SEARCH · Search NASA

Results for “Timing resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

HRPPD photosensors for RICH detectors with a high resolution timing capability

Recently, a new version of DC-coupled High Rate Picosecond Photodetectors (DC-HRPPDs) substantially re-designed for use at the Electron-Ion Collider (EIC) has been developed. A first batch of seven “EIC HRPPDs” was manufactured in early 2024. These HRPPDs are DC-coupled photosensors based on Micro-Channel Plates (MCPs) that have an active area of 104 mm by 104 mm, 32 × 32 direct readout pixel array at a pitch of 3.25 mm, peak quantum efficiency in excess of 30%, exceptionally low dark count rates and timing resolution of 15–20 ps for a single photon detection. As such, these photosensors are very well suited for Ring Imaging CHerenkov (RICH) detectors that can additionally provide high resolution timing capability, especially in a configuration where a detected charged particle passes through the sensor window, which produces a localized flash containing a few dozens of Cherenkov photons in it.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Instrumentation and methods for efficient time-resolved X-ray crystallography of biomolecular systems with sub-10 ms time resolution

Time-resolved X-ray crystallography has great promise to illuminate structure–function relations and key steps of enzymatic reactions with atomic resolution. The dominant methods for chemically-initiated reactions require complex instrumentation at the X-ray beamline, significant effort to operate and maintain this instrumentation, and enormous numbers (∼10 5 –10 9 ) of crystals per time point. We describe instrumentation and methods that enable high-throughput time-resolved study of biomolecular systems using standard crystallography sample supports and mail-in X-ray data collection at standard high-throughput cryocrystallography synchrotron beamlines. The instrumentation allows rapid reaction initiation by mixing of crystals and substrate/ligand solution, rapid capture of structural states via thermal quenching with no pre-cooling perturbations, and yields time resolutions in the single-millisecond range, comparable to the best achieved by any non-photo-initiated method in both crystallography and cryo-electron microscopy. Our approach to reaction initiation has the advantages of simplicity, robustness, low cost, adaptability to diverse ligand solutions and small minimum volume requirements, making it well suited to routine laboratory use and to high-throughput screening. We report the detailed characterization of instrument performance, present structures of binding of N -acetylglucosamine to lysozyme at time points from 8 ms to 2 s determined using only one crystal per time point, and discuss additional improvements that will push time resolution toward 1 ms.

Indergaard, John A. (ORCID:000000022367699X)

Impact of light output on the timing resolution of organic glass scintillator bars in a dual-ended readout configuration

The effectiveness of detector system modeling and validation depends on the quality of characterization performed on the system. For nuclear nonproliferation applications, which require detectors to address complex and variable field conditions, access to accurate system models is essential. This study presents the timing characterization of organic glass scintillator bars used in an imaging system developed at the University of Michigan. 137 Cs and 60 Co gamma-ray sources were used to determine the coincidence time resolution as a function of measured light output for two Compton scatter events between two organic glass scintillator bars. Timing resolution for two events, each with light output ranging from 100 to 1100 keVee were characterized. The resulting data were fit to a parametric function that was validated to agree with experimental results within ±25 ps. Simulations were performed to establish appropriate calibration points for each organic scintillator, thereby ensuring accurate calibration of light output values during analysis. This work successfully characterized the light output dependence of the coincidence timing resolution of a pair of organic glass detectors for use in an imaging system. Depending on the amount of scintillation light output from the events, the full width at half maximum of the measured coincidence time resolution ranged from 653.2 ± 16.1 ps for low light yields, 100 keVee, to 121.0 ± 8.4 ps for higher yields at 1100 keVee. The insights obtained from the timing resolution behavior will allow for accurate simulation capabilities in future security and verification efforts using scatter-based imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Phase-based velocity extraction method for photonic Doppler velocimetry with potential higher time resolution

We present an extension of the [Takeda et al., J. Opt. Soc. Am. 72, 156 (1982)] phase extraction method to heterodyne photonic Doppler velocimetry applications. The method yields results equivalent to those obtained by the short-time Fourier transform (STFT), while offering potential improvements in time resolution. Unlike STFT, which relies on window functions, such as the Hamming window, that emphasize central data points and diminish the influence of edges, the extended Takeda method utilizes all data uniformly. This uniform treatment allows for the derivation of empirical equations that directly relate velocity error to the actual time resolution rather than to the local analysis duration. The established equation provides a useful metric for both optimizing hardware configuration and guiding data analysis. Simulation and experimental results confirm that, for a given dataset, specifying a target time resolution yields consistent velocity errors for both methods. These findings underscore the Takeda method’s advantages, particularly its potential higher time resolution and reduced computational burden, making it a valuable tool for high-throughput applications such as laser dynamic compression experiments.

Computer simulation

Time Resolution Characterization of 4H-SiC LGADs with a 90 Sr Source

This work presents timing measurements of 4H-SiC Low Gain Avalanche Detectors (4H-SiC LGADs) using beta particles from a 90Sr source. The 4H-SiC LGADs exhibit fast signal responses, and a time resolution of 61 ps was achieved, comparable to that of standard Si LGADs. The present limitation in the time resolution of 4H-SiC LGADs appears to stem from limited charge generation. Nevertheless, their higher voltage tolerance and faster carrier drift suggest that, with increased charge collection, their timing performance could approach or even surpass that of Si LGADs. Furthermore, these results demonstrate the strong potential of 4H-SiC LGADs as a robust platform for precision timing in future 4D tracking detectors, while also highlighting that signal charge is the dominant factor currently limiting their performance, indicating that further optimization of gain and drift structures will be essential for future development.

43 PARTICLE ACCELERATORS

High Time Resolution Modelled and Measured New Particle Formation Rates During the 2023 Pittsburgh, PA Campaign

Particle size distributions are used to calculate nucleation rates during new particle formation (NPF). However, the low time resolution and poor sensitivity of instruments deployed to observe particle size distributions can lead to inaccurate estimates of nucleation rates. We calculated nucleation rates in Pittsburgh, PA from particle size distributions measured with the new high time resolution Condensation Particle Counters For Atmospheric Rapid Measurements (CPC FARM) and from gas precursor concentrations measured with a chemical ionization mass spectrometer. The CPC FARM nucleation rates were calculated by examining the appearance rate of particles in the smallest size bin at 1.6 nm. The nucleation rate of 1.6 nm determined every second resulted in positive and negative rates, indicating the influence of inhomogeneous mixing and advection of precursor gases and clusters. These effects are not currently considered when estimating nucleation rates from measurements. The nucleation rates from the CPC FARM were compared to the nucleation rates determined from a transient acid‐base reaction model using measured sulfuric acid concentration, strong base concentrations, and CPC detection efficiencies. The transient form of the model allowed the advection of heterogeneously mixed precursors to influence the nucleation rate. Good agreement between particle and gas‐based nucleation rates is observed during sulfuric acid‐driven NPF events. This study demonstrates that high time resolution measurements of short‐lived and rapidly formed particles are needed to accurately capture nucleation rates, which are likely influenced by advection of nucleation precursors and clusters in heterogeneous environments such as urban areas.

Cheng, D. [Carnegie Mellon Univ., Pittsburgh, PA (

Intrinsic energy and time resolution of the Jefferson Lab Hall C Neutral Particle Spectrometer

The Neutral Particle Spectrometer (NPS) is an advanced calorimeter designed to measure neutral electro- magnetic particles with high precision in energy, time, and position, under conditions of high luminosity and significant background. Integrated into the experimental setup of Hall C at Thomas Jefferson National Accelerator Facility, the NPS plays a critical role in studies of nucleon structure through exclusive and semi- inclusive reaction channels. Here, this paper presents an assessment of the detector’s performance characteristics, specifically its energy and timing resolution, derived from elastic electron–proton scattering data. We report an energy resolution between 1.2% and 1.3% in the 4.5–7.3 GeV range, and an intrinsic timing resolution better than 200 ps for energies above 500 MeV. These results serve as a reference for current and future precision measurements in hadronic physics.

Detector performance

Single channel PICOSEC Micromegas detector with improved time resolution

This paper presents design guidelines and the experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving the stability, reducing noise, and ensuring signal integrity to optimize timing performance. A notable feature is the simple and fast reassembly procedure, facilitating quick replacement of the detector internal components that allows for an efficient measurement strategy involving different detector components. The paper also examines the influence of parasitic capacitance and inductance on the output signal integrity. To validate the design, a prototype assembly and three interchangeable detector boards with varying readout pad diameters were manufactured. Detectors were initially tested in the laboratory. Finally, the timing performance of the detectors with different pad sizes was verified using 150 GeV muons. Notably, a record time resolution for a PICOSEC Micromegas detector technology with a CsI photocathode of 12.5 ± 0.8 ps was achieved for a detector with 10 mm diameter readout pad size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Single photon detection and sub-nanosecond timing resolution with RCA C31034 photomultiplier

The very high quantum efficiencies and low dark count rates achieved with selected RCA C31034 photomultipliers make them attractive candidates for single photoelectron fast timing experiments. Single photoelectron plateau counting and a timing resolution of 0.60 nsec (FWHM) were obtained using fast amplifiers, constant fraction timing discriminators, and a pulsed light emitting diode. A redesign of the C31034 incorporating features of the very fast C31024 is suggested to yield even better timing resolution.

Reisse, R.

The time resolution domain of stellar radio astronomy

The high time resolution (HTR) radio observation of late-type stars and RS CVn systems is discussed. Some examples of these sources are addressed, identifying what information HTR observations can provide. HTR can provide important information on flares in late-type stars, and can be used to study coronal structure and the particle acceleration mechanism in these stars. The possible use of HTR to establish the nature of quiescent emission form RS CVn systems is discussed.

Bookbinder, J.

Microwave and hard X-ray observations of a solar flare with a time resolution better than 100 ms

Simultaneous microwave and X-ray observations are presented for a solar flare detected on 1980 May 8 starting at 1937 UT. The X-ray observations were made with the Hard X-ray Burst Spectrometer on the Solar Maximum Mission and covered the energy range from 28-490 keV with a time resolution of 10 ms. The microwave observations were made with the 5 and 45 foot antennas at the Itapetinga Radio Obervatory at frequencies of 7 and 22 GHz, with time resolutions of 100 ms and 1 ms respectively. Detailed correlation analysis of the different time profiles of the event show that the major impulsive in the X-ray flux preceded the corresponding microwave peaks at 22 GHz by about 240 ms. For this particular burst the 22 GHz peaks preceded the 7 GHz by about 1.5s. Observed delays of the microwave peaks are too large for a simple electron beam model but they can be reconciled with the speeds of shock waves in a thermal model. Previously announced in STAR as N82-30215

Kaufmann, P.

Microwave and hard X-ray observations of a solar flare with a time resolution of better than 100 MS

Simultaneous microwave and X-ray observations are presented for a solar flare detected on 1980 May 8 starting at 1937 UT. The X-ray observations were made with the Hard X-Ray Burst Spectrometer on the Solar Maximum Mission and covered the energy range from 28-490 keV with a time resolution of 10 ms. The microwave observations were made with the 5 and 45 foot antennas at the Itapetinga Radio Observatory at frequencies of 7 and 22 GHz, with time resolutions of 100 ms and 1 ms respectively. Detailed correlation analysis of the different time profiles of the event show that the major impulsive in the X-ray flux preceded the corresponding microwave peaks at 22 GHz by about 240ms. For this particular burst the 22 GHz peaks preceded the 7 GHz by about 1.5s. Observed delays of the microwave peaks are too large for a simple electron beam model but they can be reconciled with the speeds of shock waves in a thermal model.

Kaufmann, P.

High time resolution characteristics of intermediate ion distributions upstream of the earth's bow shock

High time resolution particle data upstream of the bow shock during time intervals that have been identified as having intermediate ion distributions often show high amplitude oscillations in the ion fluxes of energy 2 and 6 keV. These ion oscillations, observed with the particle instruments of the University of California, Berkeley, on the ISEE 1 and 2 spacecraft, are at the same frequency (about 0.04 Hz) as the magnetic field oscillations. Typically, the 6-keV ion flux increases then the 2-keV flux increases followed by a decrease in the 2-keV flux and then the 6-keV flux decreases. This process repeats many times. Although there is no entirely satisfactory explanation, the presence of these ion flux oscillations suggests that distributions often are misidentified as intermediate ion distributions.

Potter, D. W.

Increasing the time resolution of a multichannel scaler.

Description of an economical buffer unit which will extend the time resolution of a multichannel scaler to better than 100 nsec. The buffered multiscaler produces a system which has negligible dead time between the bins even at the highest resolutions. It is suitable for use in any digital signaling averaging application which meets certain conditions.

Silverberg, E. C.

A high time resolution study of the solar wind-magnetosphere energy coupling function

A high time resolution study of the relationships between the solar wind-magnetosphere energy coupling function and the total energy dissipation rate of the magnetosphere is made using 5-min average values of solar wind data and of the geomagnetic indices AE and Dst. All the results are essentially the same as those obtained by the earlier studies which were based on the hourly average data set. Therefore, it is confirmed that the magnetosphere is primarily a driven system

Akasofu, S.-I.

High time resolution plasma wave and magnetic field observations of the Jovian bow shock

High time resolution (60 ms) Voyager magnetometer and plasma wave measurements of a strong (fast Mach number 16), quasi-perpendicular Jovian bow shock reveal an abrupt change in the plasma wave spectrum at the leading edge of the shock foot. Upstream electron plasma waves terminate at the leading edge, and are replaced by a lower-frequency broadband spectrum of ion-acoustic-like waves, which terminates at the main shock ramp. The clear association with the foot region of the lower frequency component suggests that it is generated by reflected ions. If the upstream plasma waves are generated by an escaping electron heat flux, their termination at the leading edge suggests that electrons are heated by the low-frequency waves in the shock foot.

Moses, S. L.