Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tm”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Kinematics at the intersection of the Garlock and Death Valley fault zones, California: Integration of TM data and field studies. LANDSAT TM investigation proposal TM-019

Processing and interpretation of Thematic Mapper (TM) data, extensive field work, and processing of SPOT data were continued. Results of these analyses led to the testing and rejecting of several of the geologic/tectonic hypotheses concerning the continuation of the Garlock Fault Zone (GFZ). It was determined that the Death Valley Fault Zone (DVFZ) is the major through-going feature, extending at least 60 km SW of the Avawatz Mountains. Two 5 km wide fault zones were identified and characterized in the Soda and Bristol Mountains, forming a continuous zone of NW trending faulting. Geophysical measurements indicate a buried connection between the Avawatz and the Soda Mountains Fault Zone. Future work will involve continued field work and mapping at key locations, further analyses of TM data, and conclusion of the project.

Abrams, Michael↗

Investigation of loss processes of Tm and Tm,Ho in YAG

The loss of excitation from various manifolds of Tm and Tm,Ho in YAG as a function of temperature and concentration is studied. Two probable loss mechanisms - a Tm up-conversion and a Ho up-conversion - are identified. A 785-nm CW diode laser with 400-nW peak power was focused to a small spot on the sample. The emission from the sample observed at 90 deg was monitored through a monochromator with slits open to 3 mm. Intensity of emission was measured by varying the power of the excitation source using a set of neutral density filters. Power is reported as the percentage of the peak power, and the intensity curves were normalized below 20 percent of transmission. The fact that there is emission above the pump energy indicates an up-conversion from excited manifolds. Nonlinear changes in the intensity of the emission from the Tm 3F4 manifold with the pump power reveals a loss of excitation from this manifold. The linear dependence of the 5I7 manifold emission with pump power at low Tm and high Ho concentrations and the gain of energy in the 5I6 manifold of Ho indicate that the 5I7 manifold loss is due to the coupling of Tm and Ho ions.

Armagan, G.↗

Modeling Cr-to-Tm and Cr-to-Tm-to-Ho energy transfer in YAG crystals

A systematic analysis of energy transfer processes in crystals of YAG doped with varying concentrations of Cr and Tm is described. Both spectral measurements and measurements of the temporal response to pulsed excitation are used to give independent determinations of the microscopic interaction parameter for Cr to Tm transfer. The different factors in influencing the temperature dependence of the Cr to Tm transfer are discussed. The dependence of the Tm cross-relaxation rate on Tm concentration is determined.

Swetits, John J.↗

Results of a Telephone Survey of Television Station Managers Concerning the NASA SCI Files(TM) and NASA CONNECT(TM)

A telephone survey of television station managers concerning 2 instructional television programs, the NASA SCI Files(TM) and NASA CONNECT(TM), offered by the NASA Langley Center for Distance Learning (CDL) was conducted. Using a 4-point scale, with 4 being very satisfied, survey participants reported that they were either very satisfied (77.1 percent) or satisfied (19.9 percent) with the overall (educational and technical) quality of the NASA SCI Files(TM). Using a 4-point scale, with 4 being very satisfied, survey participants reported that they were either very satisfied (77.9 percent) or satisfied (19.1 percent) with the overall (educational and technical) quality of NASA CONNECT(TM) .

Pinelli, Thomas E.↗

An assembler for the MOS Technology 6502 microprocessor as implemented in jolt (TM) and KIM-1 (TM)

Design of low-cost, microcomputer-based navigation receivers, and the assembler are described. The development of computer software for microprocessors is materially aided by the assembler program using mnemonic variable names. The flexibility of the environment provided by the IBM's Virtual Machine Facility and the Conversational Monitor System, make possible the convenient assembler access. The implementation of the assembler for the microprocessor chip serves a part of the present need and forms a model for support of other microprocessors.

Lilley, R. W.↗

VPU(tm) demonstration mission vicinity processor unit(tm) overview

Evolving Technologies Corporation is designing a new type of computer called a Vicinity Processor Unit (VPU). The VPU is designed to monitor and control payloads using an operating system, control process and software environment that specifically takes into account the time delay associated with remotely controlling and monitoring a group of payloads in real time. This is a fundamentally different way of computing which has vast scientific implications for the design and implementation of data processing systems for future space flight missions. As a demonstration mission, the VPU is expected to be flown aboard the Space Shuttle (Payload Identification No. G-700) as a part of NASA's Small Self-Contained Payloads (SSCP) Program. We believe this mission can greatly facilitate the development and validation of technology which may prove to be mission critical for many future space flight missions.

Abdulezer, Loren↗

Development of flashlamp-pumped Q-switched Ho:Tm:Cr:YAG lasers for mid-infrared LIDAR application

A flashlamp-pumped 2.1 micron Ho:Tm:Cr:YAG laser was studied for both normal mode and Q-switched operations under a wide variety of experimental conditions in order to optimize performance. Laser output energy, slope efficiency, threshold and pulselength were determined as a function of operating temperature, output mirror reflectivity, input electrical energy and Q-switch opening time. The measured normal-mode laser thresholds of a Ho(3+) (0.45 atomic percent):Tm(3+) (2.5 atomic percent):Cr(3+) (0.8 atomic percent):YAG crystal ranged form 26 to 50 J between 120 and 200 K with slope efficiencies up to 0.36 percent with a 60 percent reflective output mirror. Under Q-switched operation the slope efficiency was 90 percent of the normal-mode result. Development of solid state lasers with Ho(3+), Tm(3+) and/or Er(3+) doped crystals has been pursued by NASA for eye-dafe mid-infrared LIDAR (light detection and ranging) application. As a part of the project, the authors have been working on evaluating Ho(3+):Tm(3+):Cr(3+):YAG crystals for normal-mode and Q-switched 2.1 micron laser operations in order to determine an optimum Tm(3+) concentration under flashlamp pumping conditions. Lasing properties of the Ho(3+) in the mid-infrared region have been studied by many research groups since the early 1960's. However, the technology of those lasers is still premature for lidar application. In order to overcome the inefficiency related to narrow absorption bands of the Ho(3+), Tm(3+) and Er(3+), the erbium has been replaced by chromium. The improvement in flashlamp-pumped Ho(3+) laser efficiency has been demonstrated recently by several research groups by utilizing the broad absorption spectrum of Cr(3+) which covers the flashlamp's emission spectrum. Efficient energy transfer to the Tm(3+) and then the Ho(3+) occurs subsequently. It is known that high Tm(3+) concentration and low Ho(3+) concentration are preferred to achieve a quantum efficiency approaching two and to avoid large reabsorption losses. However, determination of the optimum Tm(3+) concentration required to ensure efficient energy transfer from Cr(3+) to Tm(3+) and from Tm(3+) to Ho(3+) has not been made in the Ho:Tm:CR:YAG crystal. The results obtained so far are given.

Choi, Young S.↗

Preliminary Study of Information Extraction of LANDSAT TM Data for a Suburban/regional Test Site

A substantial amount of spectral information is available from TM (as compared to MSS) data for a 14.25 square km area between Beltsville and Laurel, Maryland. Large buildings and street patterns were resolved in the TM imagery. While there was added information content in TM data for discriminating surburban/regional land cover, characteristics of MSS can improve land cover discrimination over TM when conventional classification procedures are used on digital data. The improved qualitization of TM is likely valuable in situations where there are spectral similarities between classes. The spatial resolution in TM decreased land cover discrimination as a result of increased within class variability. For many general digital evaluations, inclusion of four bands representing the four spectral regions can provide much useful land cover discrimination. Inclusion of TM 6 indicates an improvement in spectral class discrimination. Of primary spectral importance is the discrimination between water, vegetative surfaces, and impervious surfaces due to differences in thermal properties. Results from the principle component transformed data clearly indicates additional information content in TM over MSS.

Toll, D. L.↗

Comparison of spectroscopic properties of Tm and Ho in YAG and YLF crystals

The paper compares the cross-relaxation, energy transfer and loss processes in Tm- and Ho-doped YAG and YLF as a function of temperature, Tm concentration, and excitation power. Significant differences in the behavior of Tm and Tm,Ho in YAG and YLF crystals were found. The cross-relaxation rates of Tm(6 pct) are faster in YLF (about 5 microsec) than YAG (about 10 microsec). The energy transfer rates between Tm and Ho are faster in YLF than YAG. The time it takes for the maximum intensity of 1.7-micron emission to drop 10 percent is 25 microsec for YLF:Tm(6 pct),Ho(0.6 pct) and 65 microsec YAG:Tm(6 pct),Ho(0.5 pct). The losses occurring with increasing pump power for 2.1-micron emission of the above samples are 30 percent less in YLF than YAG. These qualitative differences point to YLF as a valuable 2-micron laser host material.

Armagan, G.↗

Performance evaluation and geologic utility of LANDSAT 4 TM and MSS scanners

Experiments using artificial targets (polyethylene sheets) to help calibrate and evaluate atmospheric effects as well as the radiometric precision and spatial characteristics of the NS-001 and TM sensor systems were attempted and show the technical feasibility of using plastic targets for such studies, although weather precluded successful TM data acquisition. Tapes for six LANDSAT 4 TM scenes were acquired and data processing began. Computer enhanced TM simulator and LANDSAT 4 TM data were compared for a porphyry copper deposit in Southern Arizona. Preliminary analyses performed on two TM scenes acquired in the CCT-PT format, show the TM data appear to contain a marked increase in geologically useful information; however, a number of instrumental processing artifacts may well limit the ability of the geologist to fully extract this information.

Paley, H. N.↗

Preliminary Comparisons of the Information Content and Utility of TM Versus MSS Data

Comparisons were made between subscenes from the first TM scene acquired of the Washington, D.C. area and a MSS scene acquired approximately one year earlier. Three types of analyses were conducted to compare TM and MSS data: a water body analysis, a principal components analysis and a spectral clustering analysis. The water body analysis compared the capability of the TM to the MSS for detecting small uniform targets. Of the 59 ponds located on aerial photographs 34 (58%) were detected by the TM with six commission errors (15%) and 13 (22%) were detected by the MSS with three commission errors (19%). The smallest water body detected by the TM was 16 meters; the smallest detected by the MSS was 40 meters. For the principal components analysis, means and covariance matrices were calculated for each subscene, and principal components images generated and characterized. In the spectral clustering comparison each scene was independently clustered and the clusters were assigned to informational classes. The preliminary comparison indicated that TM data provides enhancements over MSS in terms of (1) small target detection and (2) data dimensionality (even with 4-band data). The extra dimension, partially resultant from TM band 1, appears useful for built-up/non-built-up area separation.

Markham, B. L.↗

Characterization of LANDSAT-4 TM and MSS Image Quality for the Interpretation of California's Agricultural Resources

The quality of LANDSAT-4 MSS and TM data was determined by analyzing TM spectral and spatial performance in terms of spectral variability of natural targets and the TM-ground instantaneous field-of-view (IFOV) variability in level and mountainous terrain; and by assessing the suitability of TM and MSS image products for characterizing renewable resourse features. The TM data should be extremelly valuable for crop type and area proportion estimation; undating agricultural land use survey maps at 1:24,000 scale and smaller, field boundary definition; and determining the size and location of individual farmsteads. Ongoing research activities are focused on making spectral and spatial analyses of both MSS and TM analytical film products. The improved spectral, spatial, and radiometric quality of the TM data, should promote a renewed emphasis and interest in direct visual interpretation of these image products, both for updating and improving land stratification in support of resource inventory and for enhancing the image analyst's contribution to computer-assisted analysis procedures.

Degloria, S. D.↗

Preliminary Evaluation of TM for Soils Information

The capability of the LANDSAT TM for providing information for soil association maps and for detecting soil properties (variability within vegetated fields) was assessed using TM imagery of fields in Mississippi County, Arkansas that were planted with rice, cotton, and soybeans. Results indicate that the TM bands are providing information that is related to the soil properties within the field. Over large areas, these bands also appear to provide information that is related to the soil properties that are important to plant condition. While these results are only an indication of the information that TM can provide, they do indicate the TM data--especially, the mid-TR and thermal bands--show the capability for separating vegetated soil landscapes on a broad basis. The analysis at the field level with a growing crop also indicates that TM, with its additional and narrower bands and improved spatial and radiometric resolution is influenced by within field variability due to soils that has to be accounted for in the analysis of TM data.

Thompson, D. R.↗

Use of the Aromascan(TM) Instrument for Nonsubjective Evaluation of Rodent Spaceflight Hardware

This report describes the verification and utilization of the AromaScan(TM) (Hollis, NH) instrument for the ground-based evaluation of odor containment by various spaceflight habitats developed at NASA's Ames Research Center (ARC). The AromaScan(TM) instrument is an electronic odor detection system consisting of 32 polymer sensors that respond differentially to 10 different chemical groups present in an air sample. The AromaScan(TM) system also includes neural network software for constructing a database of known odors, against which an unknown odor can be compared. At present, the standard method for characterizing rodent odor containment during the development and testing of spaceflight hardware is the use of a human odor assessment panel. However, this can be a very time consuming and costly process, and the results are inherently subjective. The AromaScan(TM) system should produce more consistent and objective results, as well as a cost savings in the long term. To test and verify the AromaScan(TM) instrument, daily air samples will be collected from the exhaust port of rodent habitats, during experiment development tests, then injected into the instrument and used to create a database of recognizable odors. Human sniff tests will be performed in conjunction with the AromaScan(TM) analysis, and the results will be correlated. We will then teach the neural network to differentiate between an acceptable and an unacceptable odor profile, as defined by the human sniff test, and to be able to accurately identify an odor that would not pass a sniff panel. The results of our efforts will be to verify that the AromaScan(TM) system is a valuable alternative to human sniff panel assessments for the early iterative process of designing and testing rodent waste filters for spaceflight. Acceptance by a human panel will remain one of the final criteria for successful rodent habitat development.

Scribner, K. A.↗

Use of the TM tasseled cap transform for interpretation of spectral contrasts in an urban scene

Investigations are being conducted with the objective to develop automated numerical image analysis procedures. In this context, an examination is performed of physically-based multispectral data transforms as a means to incorporate a priori knowledge of land radiance properties in the analysis process. A physically-based transform of TM observations was developed. This transform extends the Landsat MSS Tasseled Cap transform reported by Kauth and Thomas (1976) to TM data observations. The present study has the aim to examine the utility of the TM Tasseled Cap transform as applied to TM data from an urban landscape. The analysis conducted is based on 512 x 512 subset of the Washington, DC November 2, 1982 TM scene, centered on Springfield, VA. It appears that the TM tasseled cap transformation provides a good means to explain land physical attributes of the Washington scene. This result provides a suggestion regarding a direction by which a priori knowledge of landscape spectral patterns may be incorporated into numerical image analysis.

Goward, S. N.↗

Spectroscopic characterization of dynamical processes for Tm,Ho:YAG lasers

The energy transfer processes in Tm,Ho:YAG lasers were investigated in spectral studies and measurements of the temporal response to pulsed excitation. These processes include the population of the 3H4 pump band of Tm, cross-relaxation in Tm, the transfer of energy from Tm to Ho, and various loss mechanisms. It was found that the Tm cross-relaxation is due to a dipole-dipole interaction between Tm ions and that the rate of this process is a function of temperature and ion concentration.

Armagan, G.↗

Prepsolv (TM): The optimum alternative to 1,1,1-trichloroethane and methyl ethyl ketone for hand-wipe cleaning of aerospace materials

Engineers at Hercules Aerospace, a rocket motor manufacturer in Utah, have worked closely with chemists at Glidco Organics to study the feasibility of using terpenes for zero-residue wipe cleaning. The result of this work is a technological breakthrough, in which the barrier to ultra-low non-volatile residue formation has been broken. After 2 years of development and testing, SCM Glidco Organics has announced the availability of Glidsafe(registered trademark) Prepsolv(TM): a state-of-the-art ultra-low residue terpene wipe cleaning agent that does not require rinsing. Prepsolv(TM) can successfully be used in simple hand-wipe cleaning processes without fear of leaving surface residues. Industry testing has confirmed that Prepsolv(TM) is not only highly effective, but can even be less expensive to use than traditional cleaning solvents like methyl chloroform. This paper addresses the features and benefits of Prepsolv(TM), and presents performance and material compatibility data that characterizes this unique cleaning agent. Since its commercialization, Hercules Aerospace has chosen Prepsolv(TM) as the optimum cleaning agent to replace ozone-depleting solvents in their weapons factory in Magna, UT. Likewise, Boeing has approved Prepsolv(TM) for cleaning components in the manufacture of commercial aircraft at their facilities in Seattle, WA and Wichita, KS. Additional approvals are forthcoming for this uniquely safe and effective solvent.

Gallagher, R. Scott↗

Performance evaluation and geologic utility of LANDSAT-4 TM and MSS data

Radiometric calibration accuracy of TM data, radiometric comparison of A-, B-, and P-format data, and geometric registration accuracy of the TM data at enlarged scales were analyzed. Radiometric analysis of the Wind River Basin, Wyoming scene demonstrates that the TM system can be used to extract image reflectance spectra from ground targets following calibration of the system. It was also demonstrated that: (1) image DN (radiance values) vs. ground reflectance calibration scatterplots yield parameters which can be used to constrain atmospheric models and can determine TM radiometric sensitivity; (2) no significant degradation occurs as a result of radiometric and geometric correction by SCROUNGE processing; and (3) TM data can be enlarged to 1:24000 with no major geometric distortions or misregistration problems to USGS topographic maps.

Paylor, E. D.↗