Pentaerythritol structure-directing agents bias aluminum siting in MFI zeolites to increase para -xylene selectivity during toluene methylation

MFI zeolites contain ten-membered ring channels (∼0.55 nm diameter) that intersect to form larger voids (∼0.70 nm diameter). The distribution of framework Al sites dictates the void environments that confine active H + sites. MFI synthesized with pentaerythritol (PET) and Na + as structure-directing agents are interrogated using kinetically controlled toluene methylation rates and xylene isomer selectivities. High para-xylene selectivity and low toluene methylation rates indicate that MFI-PET samples contain H + sites predominantly in smaller channels. As-synthesized samples contain more framework Al than Na + , indicating that some charge compensation is provided by protonated PET-solvent complexes that bias Al siting towards these smaller channels.

36 MATERIALS SCIENCE↗

Toluene Uptake and Outgassing by a 3D-Printed Silicone and the Impact on Mechanical Performance

Silicone elastomers have advantageous physical properties and are widely used in various applications. Additive manufacturing (AM) of silicones provides additional utility by enabling tunable mechanical and functional properties. However, the performance of these elastomers deteriorates over time with exposure to environmental stressors. Organic solvents and volatile organic compounds (VOCs) are stressors that can cause dimensional changes to silicones with exposure and impact the overall function. Yet, the effects of such exposure on mechanical performance, including load response (LR), are not well understood. Here, in this study, we investigated the impact of a nonpolar solvent, toluene, on AM silicone material properties and compressive load. We observed that AM silicones rapidly absorbed toluene and swelled, leading to an increase in relative LR. Toluene concentration and compression did not affect uptake or swelling rates. In contrast, outgassing rates were slower for compressed coupons compared to uncompressed specimens, attributed to geometric constraints and polymer network changes impacting toluene diffusion outward. Compression also pinned the AM silicones at an enlarged state, significantly reducing relative LR after outgassing. Depending on toluene concentrations and compression, AM silicones can remain robust against toluene exposure and recover their initial printing geometry and mechanical performance after toluene outgassing and polymer relaxation.

Materials science↗

Microwave-Assisted dry reforming of toluene as a model tar compound using low-cost iron catalyst for syngas clean-up

Gasification of waste feedstock such as biomass, waste plastics suffers from high tar yields during hydrogen-rich syngas production. The presence of tars result in lower quality syngas, lower syngas yields, reactor blockage, reactor down time, and costly maintenance. Therefore, removal of tar from syngas during gasification is essential. Catalytic reforming of tars via in-situ syngas cleanup is an effective way of mitigating tars. This work explores the possibility of microwave-assisted catalytic dry reforming of tars for syngas production. Further, due to its chemical complexity, toluene, which is one of the main tar constituents, could be used as a model tar compound. Toluene dry reforming was studied using the Fe/Al 2 O 3 catalyst under CO 2 under the temperature range of 400–700 °C. The toluene reforming reaction was conducted using microwave and conventional thermal reactors. Under microwave irradiation, CO 2 and toluene conversions are boosted to 80% at 500 °C. Hydrogen and carbon monoxide yields were approximately five times and ten times higher in the microwave reactor at 500 °C, respectively, compared to the productions obtained in the conventional fixed-bed reactor at 700 °C. Filamentous carbon was also produced as a valuable side product to improve the economy of this process and such value-added carbon was only observed in the microwave reactor. Three reaction pathways were observed during microwave reaction: the toluene decomposition produces an initial hydrogen and carbon deposit on the catalyst; the formation of methane and benzene suggests toluene hydrodemethylation as a secondary reaction; and toluene hydrogenolysis forms light alkanes such as methane, and through reforming reaction under CO 2 to syngas.

10 SYNTHETIC FUELS↗

Detailed mechanism of toluene oxidation and comparison with benzene

A detailed mechanism for the oxidation of toluene in both argon and nitrogen dilutents is presented. The mechanism was used to compute experimentally ignition delay times for shock-heated toluene-oxygen-argon mixtures with resonably good success over a wide range of initial temperatures and pressures. Attempts to compute experimentally measured concentration profiles for toluene oxidation in a turbulent reactor were partially successful. An extensive sensitivity analysis was performed to determine the reactions which control the ignition process and the rates of formation and destruction of various species. The most important step was found to be the reaction of toluene with molecular oxygen, followed by the reactions of hydroperoxyl and atomic oxygen with benzyl radicals. These findings contrast with the benzene oxidation, where the benzene-molecular oxygen reaction is quite unimportant and the reaction of phenyl with molecular oxygen dominates. In the toluene mechanism the corresponding reaction of benzyl radicals with oxygen is unimportant. Two reactions which are important in the oxidation of benzene also influence the oxidation of toluene for several conditions. These are the oxidations of phenyl and cyclopentadienyl radicals by molecular oxygen. The mechanism presented successfully computes the decrease of toluene concentration with time in the nitrogen diluted turbulent reactor. This fact, in addition to the good prediction of ignition delay times, shows that this mechanism can be used for modeling the ignition and combustion process in practical, well-mixed combustion systems.

Bittker, David A.↗

Toluene stability Space Station Rankine power system

A dynamic test loop is designed to evaluate the thermal stability of an organic Rankine cycle working fluid, toluene, for potential application to the Space Station power conversion unit. Samples of the noncondensible gases and the liquid toluene were taken periodically during the 3410 hour test at 750 F peak temperature. The results obtained from the toluene stability loop verify that toluene degradation will not lead to a loss of performance over the 30-year Space Station mission life requirement. The identity of the degradation products and the low rates of formation were as expected from toluene capsule test data.

Havens, V. N.↗

Atmospheric analyzer, carbon monoxide monitor and toluene diisocyanate monitor

The purpose of the atmospheric analyzer and the carbon monoxide and toluene diisocyanate monitors is to analyze the atmospheric volatiles and to monitor carbon monoxide and toluene diisocyanate levels in the cabin atmosphere of Skylab. The carbon monoxide monitor was used on Skylab 2, 3, and 4 to detect any carbon monoxide levels above 25 ppm. Air samples were taken once each week. The toluene diisocyanate monitor was used only on Skylab 2. The loss of a micrometeoroid shield following the launch of Skylab 1 resulted in overheating of the interior walls of the Orbital Workshop. A potential hazard existed from outgassing of an isocyanate derivative resulting from heat-decomposition of the rigid polyurethane wall insulation. The toluene diisocyanate monitor was used to detect any polymer decomposition. The atmospheric analyzer was used on Skylab 4 because of a suspected leak in the Skylab cabin. An air sample was taken at the beginning, middle, and the end of the mission.

Shannon, A. V.↗

Oxidation Mechanisms of Toluene and Benzene

An expanded and improved version of a previously published benzene oxidation mechanism is presented and shown to model published experimental data fairly successfully. This benzene submodel is coupled to a modified version of a toluene oxidation submodel from the recent literature. This complete mechanism is shown to successfully model published experimental toluene oxidation data for a highly mixed flow reactor and for higher temperature ignition delay times in a shock tube. A comprehensive sensitivity analysis showing the most important reactions is presented for both the benzene and toluene reacting systems. The NASA Lewis toluene mechanism's modeling capability is found to be equivalent to that of the previously published mechanism which contains a somewhat different benzene submodel.

Bittker, David A.↗

A Full-Cell Model for Direct Toluene Electro-Hydrogenation Electrolysis

Liquid organic hydrogen carriers (LOHCs) are organic molecules that undergo a hydrogenation/dehydrogenation cycle to enable storage and transportation of hydrogen fuel under ambient conditions. One promising LOHC candidate is toluene, which can be converted to methylcyclohexane (MCH) electrochemically, enabling a decarbonized process when green electricity is used. In this study, we developed a full-cell model for the direct electro-hydrogenation of toluene to MCH, utilizing a zero-gap membrane electrode assembly architecture. The model incorporates electrochemical kinetics, ionic transport, water transport across the membrane, and mass transport effects. Electrochemical kinetics are characterized using Tafel analysis on Pt/Ru catalyst. The model is validated against experimental data, including polarization curves, Faradaic efficiencies, and water crossover. A voltage breakdown analysis shows that the performance is dominated by kinetic losses, and the model is used to carry out a comparison of different toluene electro-hydrogenation reaction catalysts. Finally, a sensitivity analysis is conducted on key design parameters illustrating which can be modified to maximize electrolyzer performance. The cathode specific surface area and cathode porous transport layer thickness (PTL) have the largest impact on the current density, while the PTL thickness and Pt loading in the PTL have the largest impact on Faradaic efficiency.

Ehlinger, Victoria M. [Lawrence Livermore National↗

Chemical kinetic modeling of benzene and toluene oxidation behind shock waves

The oxidation of stoichiometric mixtures of benzene and toluene behind incident shock waves was studied for a temperature range from 1700 to 2800 K and a pressure range from 1.1 to 1.7 atm. The concentration of CO and CO2 produced were measured as well as the product of the oxygen atom and carbon monoxide concentrations. Comparisons between the benzene experimental data and results calculated by use of a reaction mechanism published in the open literature were carried out. With some additional reactions and changes in rate constants to reflect the pressure-temperature range of the experimental data, a good agreement was achieved between computed and experimental results. A reaction mechanism was developed for toluene oxidation based on analogous rate steps from the benzene mechanism. Measurements of NOx levels in an actual flame device, a jet-stirred combustor, were reproduced successfully by use of the reaction mechanism developed from the shock-tube experiments on toluene. These experimental measurements of NOx levels were reproduced from a computer simulation of a jet-stirred combustor.

Mclain, A. G.↗

Ignition delay times of benzene and toluene with oxygen in argon mixtures

The ignition delay times of benzene and toluene with oxygen diluted in argon were investigated over a wide range of conditions. For benzene the concentration ranges were 0.42 to 1.69 percent fuel and 3.78 to 20.3 percent oxygen. The temperature range was 1212 to 1748 K and the reflected shock pressures were 1.7 to 7.89 atm. Statistical evaluation of the benzene experiments provided an overall equation which is given. For toluene the concentration ranges were 0.5 to 1.5 percent fuel and 4.48 to 13.45 percent oxygen. The temperature range was 1339 to 1797 K and the reflected shock pressures were 1.95 to 8.85 atm. The overall ignition delay equation for toluene after a statistical evaluation is also given. Detailed experimental information is provided.

Burcat, A.↗

The Pyrolysis of Toluene and Ethyl Benzene

The pyrolysis of toluene at 850 to 950 C gave mainly H2, CH4, and benzene; PhEt at 650 to 750 C gave mainly H2, CH4, styrene, benzene, and toluene. The rate constants for PhEt pyrolysis were 1000 times higher than those for toluene pyrolysis; the chain initiation rate constants differed by the same factor. The activation energy differences were 46 kJ/mole for the total reaction and 54 kJ/mole for chain initiation. The chain length was evaluated for the PhEt case (10 + or - 2).

V G Sokolovskaya↗

Determination of Benzene, Toluene, and Xylene by means of an ion mobility spectrometer device using photoionization

The continuous monitoring of changes on the quality of ambient air is a field of advantage of ion mobility spectrometry. Benzene, Toluene, and Xylene are substances of special interest because of their toxicity. We present an optimized drift tube for ion mobility spectrometers, which uses photo-ionization tubes to produce the ions to be analyzed. The actual version of this drift tube has a length of 45 mm, an electric field strength established within the drift tube of about 180 V/cm and a shutter-opening-time of 400 mus. With the hydrogen tube used for ionisation a mean flux of 10(exp 12) photons/sq cm s was established for the experiments described. We discuss the results of investigations on Benzene, Toluene, and Xylene in normal used gasoline SUPER. The detection limits obtained with the ion mobility spectrometer developed in co-operation are in the range of 10 ppbv in this case. Normally, charge transfer from Benzene ions to Toluene takes place. Nevertheless the simultaneous determination in mixtures is possible by a data evaluation procedure developed for this case. The interferences found between Xylene and others are rather weak. The ion mobility spectra of different concentrations of gasoline SUPER are attached as an example for the resolution and the detection limit of the instrument developed. Resolution and sensitivity of the system are well demonstrated. A hand-held portable device produced just now is to be tested for special environmental analytical problems in some industrial and scientific laboratories in Germany.

Leonhardt, J. W.↗

Flight Investigation of the Knock-Limited Performance of a Triptane Blend, a Toluene Blend, and 28-R Fuel in an R-1830-75 Engine

Knock-limited performance data were obtained for three fuels on an R-1830-75 engine in a B-24D airplane at engine speeds of 1800, 2250, and 2600 rpm, a spark advance of 25 degrees B.T.C., and carburetor-air temperatures of 85 F for 1800 and 2250 rpm and 100 F for 2600 rpm. The test fuels were a blend of 80 percent 28-R plus 20 percent triptane (leaded to 4.5 ml TEL/gal), a blend of 80 percent 28-R plus 15 percent toluene (leaded to 4.5 ml TEL / gal), and 28-R fuel. The knock-limited manifold pressure of the toluene blend depreciated more in the lean region than the triptane blend or 28-R fuel. The knock-limited brake horsepower for the triptane blend varied from 16 to 25 percent higher than 28-R in the lean region and 18 to 30 percent higher in the rich region. The knock-limited brake horsepower of the toluene blend was approximately 15 percent higher than that of 28-R in the rich region and varied from 2 to 10 percent higher in the lean region. Knock limits of the triptane blend and 28-R fuel tested in the R-1830-75 engine agreed with limits for the same fuels determined with the R-1830-94 engine for engine speeds of 1800 and 2250 rpm.

Blackman, Calvin C.↗

Toluene adsorption and capacity regeneration using zeolite-based monolith and activated carbon fiber felt

Common adsorbents studied to remove volatile organic compounds (VOCs) from indoor air can release previously adsorbed VOCs back into the indoor space when the adsorbent is saturated or if the VOC concentration fluctuates. A durable adsorbent with a continuous regeneration strategy could prevent this recontamination of the indoor air and reduce adsorbent disposal waste. A deeper understanding of the adsorption and desorption behavior of VOC adsorbents is needed to create an efficient regeneration strategy. This study investigated the adsorption and thermal desorption behavior of toluene on two different adsorbents, (1) a zeolite-based adsorbent and (2) an activated carbon fiber (ACF) felt. Consistent adsorption behavior across a series of toluene concentrations was used to experimentally determine effective adsorption capacity. When the cumulative adsorption between thermal regeneration steps was maintained below the maximum effective capacity with 0% breakthrough, the zeolite-based adsorbent was found to effectively minimize passive desorption. The impact of regeneration feed conditions, such as inert, oxidizing, humidified air, on thermal desorption was examined. These conditions influenced desorption of the zeolite-based adsorbent but had minimal impact on the ACF felt adsorbent, which would lead to different regeneration schedules and methods for applications in buildings' heating, ventilation, and air conditioning (HVAC) systems.

Moses-DeBusk, Melanie [Oak Ridge National Laborato↗

Structuring, stochastic behavior, and charge storage capacity of redox-active microemulsions formulated with mixtures of toluene and ionic liquid as oil phase

Oil/water microemulsions (µEs) are promising electrolytes for redox flow batteries (RFBs) as they simultaneously improve charge capacity and ionic conductivity. Here, we report the successful formulation of bicontinuous µEs where the oil phase is a solution of trihexyltetradecylphosphonium bis(trifluoromethylsulfonyl)amide ionic liquid in toluene with redox-active ferrocene. We examined the effect of supporting electrolyte anion (NO 3 – , Cl – , ClO 4 – ) on the structure, reactivity, transport, and electrolytic performance of redox-active µEs. Neutron scattering and nuclear magnetic resonance showed that the domain size increased as Cl – > NO 3 – > ClO 4 – while the ferrocene diffusion coefficient increased as NO 3 – > Cl – > ClO 4 – . Scanning electrochemical microscopy indicated anion-dependent current fluctuations during electrolysis, with ClO 4 – exhibiting the least high-frequency oscillations, which correlate to the highest charge and discharge capacity and reversibility. All ionic liquid containing systems improved the performance of toluene-based µEs, highlighting new design principles for these electrolytes.

diffusion↗

Study of toluene stability for an Organic Rankine Cycle (ORC) space-based power system

The design, fabrication, assembly, and endurance operation of a dynamic test loop, built to evaluate the thermal stability of a proposed Organic Rankine Cycle (ORC) working fluid, is discussed. The test fluid, toluene, was circulated through a heater, simulated turbine, regenerator, condenser and pump to duplicate an actual ORC system. The maximum nominal fluid temperature, 750 F, was at the turbine simulator inlet. Samples of noncondensible gases and liquid toluene were taken periodically during the test. The samples were analyzed to identify the degradation products formed and the quantity of these products. From these data it was possible to determine the degradation rate of the working fluid and the generation rate of noncondensible gases. A further goal of this work was to relate the degradation observed in the dynamic operating loop to degradation obtained in isothermal capsule tests. This relationship was the basis for estimating the power loop degradation in the Space Station Organic Rankine Cycle system.

Havens, Vance↗

Data Mining of Groundwater to Identify MAGs with Methane, Propane and Toluene Monooxygenases

Whole genome sequencing datasets, involving more than 600 groundwater samples, from nine countries, were analyzed to identify metagenome assembled genomes (MAGs) containing full operons for propane monooxygenase, soluble methane monooxygease, toluene monooxygenase and particulate ammonia/methane monooxygenase. The enzymes encoded by these genes are a focus of interest because of their ability to degrade common groundwater contaminants. Due to the large amount of data, sequence analyses involved more than 80 individual KBase narratives. The approach followed the KBase tutorial called "Metagenome-Assembled Genome Extraction from a Compost Microbiome Enrichment" The generated MAGs were exported from each individual narrative into separate summary KBase narratives for each monooxygenase. Three KBase narratives were generated for particulate ammonia/methane monooxygenase, due to the large number of MAGs identified.

59 BASIC BIOLOGICAL SCIENCES↗

Toluene Adsorption and TPD

Raw data for toluene adsorption and TPD experiments on two different adsorbents using a custom flow-through, bench-top reactor capable of controlling gas compositions and temperature.