Search NASA⌕ Search

SEARCH · Search NASA

Results for “Touch sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Touch Sensor for Robots

Touch sensor for robot hands provides information about shape of grasped object and force exerted by gripper on object. Pins projecting from sensor create electrical signals when pressed. When grasped object depresses pin, it contacts electrode under it, connecting electrode to common electrode. Sensor indicates where, and how firmly, gripper has touched object.

Primus, H. C.↗

Touch sensors and control.

Description of the equipment employed and results obtained in experiments with tactile feedback and different levels of automatic control. In the experiments described tactile feedback was investigated by incorporating a touch sensing and touch display system into a teleoperator, while the levels of automatic control were investigated by incorporating supervisory control features in the teleoperator control system. In particular, a hand contact system which senses and reproduces to the operator the contact between the end-effector and the object being touched or manipulated is described, as well as a jaw contact system which senses and reproduces to the operator the shape and location of the object held in the remote jaws, and an arm control system consisting of a control station where the operator controls the motion of the arm by transmitting commands, a remote station that accepts the commands and uses them, and a communications link that limits information flow. In addition, an algorithmic language for remote manipulation is described, and the desired features that an automatic arm controller should possess are reviewed.

Hill, J. W.↗

Touch Sensor Responds to Contact Pressure

Optical tactile sensor for mechanical hands senses contact pressure via change in light reflected from an elastic covering. Pressure against a cell cover causes distortion, which changes internal reflection of light. Change is sensed by detector, and output signal informs operator of contact. The greater the pressure and distortion, the greater the change in light reflection.

Bejczy, A. K.↗

Measuring Thicknesses of Wastewater Films

Sensor determines when thickness of film of electrically conductive wastewater on rotating evaporator drum exceeds preset value. Sensor simple electrical probe that makes contact with liquid surface. Made of materials resistant to chemicals in liquid. Mounted on shaft in rotating cylinder, liquid-thickness sensor extends toward cylinder wall so tip almost touches. Sensor body accommodates probe measuring temperature of evaporated water in cylinder.

Schubert, F. H.↗

The use of multisensor data for robotic applications

The feasibility of realistic autonomous space manipulation tasks using multisensory information is shown through two experiments involving a fluid interchange system and a module interchange system. In both cases, autonomous location of the mating element, autonomous location of the guiding light target, mating, and demating of the system were performed. Specifically, vision-driven techniques were implemented to determine the arbitrary two-dimensional position and orientation of the mating elements as well as the arbitrary three-dimensional position and orientation of the light targets. The robotic system was also equipped with a force/torque sensor that continuously monitored the six components of force and torque exerted on the end effector. Using vision, force, torque, proximity, and touch sensors, the two experiments were completed successfully and autonomously.

Abidi, M. A.↗

Capturing in-field root system dynamics with RootTracker

Abstract Optimizing root system architecture offers a promising approach to developing stress tolerant cultivars in the face of climate change, as root systems are critical for water and nutrient uptake as well as mechanical stability. However, breeding for optimal root system architecture has been hindered by the difficulty in measuring root growth in the field. Here, we describe the RootTracker, a technology that employs impedance touch sensors to monitor in-field root growth over time. Configured in a cylindrical, window shutter-like fashion around a planted seed, 264 electrodes are individually charged multiple times over the course of an experiment. Signature changes in the measured capacitance and resistance readings indicate when a root has touched or grown close to an electrode. Using the RootTracker, we have measured root system dynamics of commercial maize (Zea mays) hybrids growing in both typical Midwest field conditions and under different irrigation regimes. We observed rapid responses of root growth to water deficits and found evidence for a “priming response” in which an early water deficit causes more and deeper roots to grow at later time periods. Genotypic variation among hybrid maize lines in their root growth in response to drought indicated a potential to breed for root systems adapted for different environments. Thus, the RootTracker is able to capture changes in root growth over time in response to environmental perturbations.

Aguilar, Jeffrey J.↗

The Mapping X-Ray Fluorescence Spectrometer (MAPX)

MapX will provide elemental imaging at ≤100 micron spatial resolution over 2.5 X 2.5 centimeter areas, yielding elemental chemistry at or below the scale length where many relict physical, chemical, and biological features can be imaged and interpreted in ancient rocks. MapX is a full-frame spectroscopic imager positioned on soil or regolith with touch sensors. During an analysis, an X-ray source (tube or radioisotope) bombards the sample surface with X-rays or αlpha-particles / gamma rays, resulting in sample X-ray Fluorescence (XRF). Fluoresced X-rays pass through an X-ray lens (X-ray μ-Pore Optic, "MPO") that projects a spatially resolved image of the X-rays onto a CCD. The CCD is operated in single photon counting mode so that the positions and energies of individual photons are retained. In a single analysis, several thousand frames are stored and processed. A MapX experiment provides elemental maps having a spatial resolution of ≤100 micron and quantitative XRF spectra from Regions of Interest (ROI) 2 centimers ≤ x ≤ 100 micron. ROI are compared with known rock and mineral compositions to extrapolate the data to rock types and putative mineralogies. The MapX geometry is being refined with ray-tracing simulations and with synchrotron experiments at SLAC. Source requirements are being determined through Monte Carlo modeling and experiment using XMIMSIM [1], GEANT4 [2] and PyMca [3] and a dedicated XRF test fixture. A flow-down of requirements for both tube and radioisotope sources is being developed from these experiments. In addition to Mars lander and rover missions, MapX could be used for landed science on other airless bodies (Phobos/Deimos, Comet nucleus, asteroids, the Earth's moon, and the icy satellites of the outer planets, including Europa.

Blake, David↗

Manipulation based on sensor-directed control: An integrated end effector and touch sensing system

A hand/touch sensing system is described that, when mounted on a position-controlled manipulator, greatly expands the kinds of automated manipulation tasks that can be undertaken. Because of the variety of coordinate conversions, control equations, and completion criteria, control is necessarily dependent upon a small digital computer. The sensing system is designed both to be rugged and to sense the necessary touch and force information required to execute a wide range of manipulation tasks. The system consists of a six-axis wrist sensor, external touch sensors, and a pair of matrix jaw sensors. Details of the construction of the particular sensors, the integration of the end effector into the sensor system, and the control algorithms for using the sensor outputs to perform manipulation tasks automatically are discussed.

Hill, J. W.↗

Tactile Sensing for Dexterous Robotic Hands

Robotic systems will be used as precursors to human exploration to explore the solar system and expand our knowledge of planetary surfaces. Robotic systems will also be used to build habitats and infrastructure required for human presence in space and on other planetary surfaces . Such robots will require a high level of intelligence and automation. The ability to flexibly manipulate their physical environment is one characteristic that makes humans so effective at these building and exploring tasks . The development of a generic autonomous grasp ing capability will greatly enhance the efficiency and ability of robotics to build, maintain and explore. To tele-operate a robot over vast distances of space, with long communication delays, has proven to be troublesome. Having an autonomous grasping capability that can react in real-time to disturbances or adapt to generic objects, without operator intervention, will reduce the probability of mishandled tools and samples and reduce the number of re-grasp attempts due to dropping. One aspect that separates humans from machines is a rich sensor set. We have the ability to feel objects and respond to forces and textures. The development of touch or tactile sensors for use on a robot that emulates human skin and nerves is the basis for this discussion. We will discuss the use of new piezo-electric and resistive materials that have emerged on the market with the intention of developing a touch sensitive sensor. With viable tacti le sensors we will be one step closer to developing an autonomous grasping capability.

Martin, Toby B.↗

Smart Sensors for Smart Hands

Proximity, force-torque, touch and slippage sensors developed or applied by the JPL Teleoperator Project for remote manipulator control are described, including sensor data handling by computers for display and control. Examples are quoted showing the significance of these sensors for manual or computer control of manipulators. An interesting example is a proximity sensor system implemented for a four-claw JSC end effector and tested at the Shuttle Manipulator Training Facility of JSC. New sensing concepts aimed at simplifying the implementation of 'Smart Sensors for Smart Hands' in the space environment are discussed.

Bejczy, A. K.↗

Estimation of cutting tool wear using an elastomeric tactile sensor

Machining performance of cutting tools and part quality are affected by the geometric condition of the cutting edge, which is influenced by thermomechanical loads experienced during the process. Tool condition monitoring (TCM) systems provide insight for timely replacement of cutting tools. However, existing TCM systems are expensive and require specialized equipment or sensors, hindering widespread adoption. A novel TCM system is developed herein using an elastomeric tactile sensor. Sensor images of the cutting edge are used to quantify wear using two distinct algorithms. In the first algorithm, the unworn and worn edges are identified based on Canny edge detect. In the second, the unworn edge is identified using edge detection while the region of wear is identified using a relative intensity method. In both cases, the maximum wear width is calculated based on an experimentally determined pixel to-physical distance scale. The TCM system is first used to estimate flank wear on a solid carbide helical end mill before evaluating its robustness by employing it to estimate insert wear of an indexable helical end mill. Measurements are also performed manually using an optical microscope and a high-resolution focus variation microscope for verification. The novel technique estimates flank wear in the solid carbide tool with a high accuracy of 98%. Larger discrepancies are observed for the inserts, however, with overlapping uncertainties. In conclusion, the technique shows promise in adaptability, automation, and closed loop control of machine tools.

Machining↗

Temperature Measurement Aid

NASA's Ames Research Center has designed a simple but medically important device--one which holds temperature probes, called thermistors, to a person's skin without affecting the characteristics of the skin segment being measured. The device improves the accuracy of skin surface temperature measurements, valuable data in health evaluation. The need for such a device was recognized in the course of life science experiments at Ames. In earlier methods, the sensing head of the temperature probe was affixed to the patient's skin by tape or elastic bands. This created a heat variance which altered skin temperature readings. The Ames-developed thermistor holder is a plastic ring with tab extensions, shown in the upper photo on the chest, arm and leg of the patient undergoing examination. The ring holds the sensing head of the temperature probe and provides firm, constant pressure between the skin and the probe. The tabs help stabilize the ring and provide attachment points for the fastening tape or bands, which do not directly touch the sensor. With this new tool, it is possible to determine more accurately the physiological effects of strenuous exercise, particularly on the treadmill. The holder is commercially available from Yellow Springs Instrument Company, Inc., Yellow Springs, Ohio, which is producing the device under a NASA patent license.

Source record↗

Transducer with a sense of touch

Matrix of pressure sensors determines shape and pressure distribution of object in contact with its surface. Output can be used to develop pressure map of objects' surface and displayed as array of alphanumeric symbols on video monitor.

Bejczy, A. K.↗

Wearable radio-frequency sensing of respiratory rate, respiratory volume, and heart rate

Abstract Many health diagnostic systems demand noninvasive sensing of respiratory rate, respiratory volume, and heart rate with high user comfort. Previous methods often require multiple sensors, including skin-touch electrodes, tension belts, or nearby off-the-body readers, and hence are uncomfortable or inconvenient. This paper presents an over-clothing wearable radio-frequency sensor study, conducted on 20 healthy participants (14 females) performing voluntary breathing exercises in various postures. Two prototype sensors were placed on the participants, one close to the heart and the other below the xiphoid process to couple to the motion from heart, lungs and diaphragm, by the near-field coherent sensing principle. We can achieve a satisfactory correlation of our sensor with the reference devices for the three vital signs: heart rate ( r = 0.95), respiratory rate ( r = 0.93) and respiratory volume ( r = 0.84). We also detected voluntary breath-hold periods with an accuracy of 96%. Further, the participants performed a breathing exercise by contracting abdomen inwards while holding breath, leading to paradoxical outward thorax motion under the isovolumetric condition, which was detected with an accuracy of 83%.

60 APPLIED LIFE SCIENCES↗

Large Scale Reduction of Graphite Oxide Project

This project seeks to develop an optical method to reduce graphite oxide into graphene efficiently and in larger formats than currently available. Current reduction methods are expensive, time-consuming or restricted to small, limited formats. Graphene has potential uses in ultracapacitors, energy storage, solar cells, flexible and light-weight circuits, touch screens, and chemical sensors. In addition, graphite oxide is a sustainable material that can be produced from any form of carbon, making this method environmentally friendly and adaptable for in-situ reduction.

Technology Portfolio System↗

Orion Rendezvous, Proximity Operations, and Docking Design and Analysis

The Orion vehicle will be required to perform rendezvous, proximity operations, and docking with the International Space Station (ISS) and the Earth Departure Stage (EDS)/Lunar Landing Vehicle (LLV) stack in Low Earth Orbit (LEO) as well as with the Lunar Landing Vehicle in Low Lunar Orbit (LLO). The RPOD system, which consists of sensors, actuators, and software is being designed to be flexible and robust enough to perform RPOD with different vehicles in different environments. This paper will describe the design and the analysis which has been performed to date to allow the vehicle to perform its mission. Since the RPOD design touches on many areas such as sensors selection and placement, trajectory design, navigation performance, and effector performance, it is inherently a systems design problem. This paper will address each of these issues in order to demonstrate how the Orion RPOD has been designed to accommodate and meet all the requirements levied on the system.

D'Souza, Christopher↗

Mapping From an Instrumented Glove to a Robot Hand

An algorithm has been developed to solve the problem of mapping from (1) a glove instrumented with joint-angle sensors to (2) an anthropomorphic robot hand. Such a mapping is needed to generate control signals to make the robot hand mimic the configuration of the hand of a human attempting to control the robot. The mapping problem is complicated by uncertainties in sensor locations caused by variations in sizes and shapes of hands and variations in the fit of the glove. The present mapping algorithm is robust in the face of these uncertainties, largely because it includes a calibration sub-algorithm that inherently adapts the mapping to the specific hand and glove, without need for measuring the hand and without regard for goodness of fit. The algorithm utilizes a forward-kinematics model of the glove derived from documentation provided by the manufacturer of the glove. In this case, forward-kinematics model signifies a mathematical model of the glove fingertip positions as functions of the sensor readings. More specifically, given the sensor readings, the forward-kinematics model calculates the glove fingertip positions in a Cartesian reference frame nominally attached to the palm. The algorithm also utilizes an inverse-kinematics model of the robot hand. In this case, inverse-kinematics model signifies a mathematical model of the robot finger-joint angles as functions of the robot fingertip positions. Again, more specifically, the inverse-kinematics model calculates the finger-joint commands needed to place the fingertips at specified positions in a Cartesian reference frame that is attached to the palm of the robot hand and that nominally corresponds to the Cartesian reference frame attached to the palm of the glove. Initially, because of the aforementioned uncertainties, the glove fingertip positions calculated by the forwardkinematics model in the glove Cartesian reference frame cannot be expected to match the robot fingertip positions in the robot-hand Cartesian reference frame. A calibration must be performed to make the glove and robot-hand fingertip positions correspond more precisely. The calibration procedure involves a few simple hand poses designed to provide well-defined fingertip positions. One of the poses is a fist. In each of the other poses, a finger touches the thumb. The calibration subalgorithm uses the sensor readings from these poses to modify the kinematical models to make the two sets of fingertip positions agree more closely.

Goza, Michael↗