Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tourniquets”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Development and Characterization of a Self-Tightening Tourniquet System

Uncontrolled hemorrhage remains a leading cause of death in both emergency and military medicine. Tourniquets are essential to stopping hemorrhage in these scenarios, but they suffer from subjective, inconsistent application. Here, we demonstrate how tourniquet application can be automated using sensors and computer algorithms. The auto-tourniquet self-tightens until blood pressure oscillations are no longer registered by the pressure sensor connected to the pneumatic pressure cuff. The auto-tourniquet’s performance in stopping the bleed was comparable to manual tourniquet application, but the time required to fully occlude the bleed was longer. Application of the tourniquet was significantly smoother, and less variable, for the automatic tourniquet compared to manual tourniquet application. This proof-of-concept study highlights how automated tourniquets can be integrated with sensors to provide a much more consistent application and use compared to manual application, even in controlled, low stress testing conditions. Future work will investigate different sensors and tourniquets to improve the application time and repeatability.

Vega, Saul J.↗

Toward Smart, Automated Junctional Tourniquets—AI Models to Interpret Vessel Occlusion at Physiological Pressure Points

Hemorrhage is the leading cause of preventable death in both civilian and military medicine. Junctional hemorrhages are especially difficult to manage since traditional tourniquet placement is often not possible. Ultrasound can be used to visualize and guide the caretaker to apply pressure at physiological pressure points to stop hemorrhage. However, this process is technically challenging, requiring the vessel to be properly positioned over rigid boney surfaces and applying sufficient pressure to maintain proper occlusion. As a first step toward automating this life-saving intervention, we demonstrate an artificial intelligence algorithm that classifies a vessel as patent or occluded, which can guide a user to apply the appropriate pressure required to stop flow. Neural network models were trained using images captured from a custom tissue-mimicking phantom and an ex vivo swine model of the inguinal region, as pressure was applied using an ultrasound probe with and without color Doppler overlays. Using these images, we developed an image classification algorithm suitable for the determination of patency or occlusion in an ultrasound image containing color Doppler overlay. Separate AI models for both test platforms were able to accurately detect occlusion status in test-image sets to more than 93% accuracy. In conclusion, this methodology can be utilized for guiding and monitoring proper vessel occlusion, which, when combined with automated actuation and other AI models, can allow for automated junctional tourniquet application.

60 APPLIED LIFE SCIENCES↗

Blended Training for Combat Medics

Bleeding from extremity wounds is the number one cause of preventable death on the battlefield and current research stresses the importance of training in preparing every Soldier to use tourniquets. HapMed is designed to provide tourniquet application training to combat medics and Soldiers using a blended training solution encompassing information, demonstration, practice, and feedback. The system combines an instrumented manikin arm, PDA, and computer. The manikin arm provides several training options including stand-alone, hands-on skills training in which soldiers can experience the actual torque required to staunch bleeding from an extremity wound and be timed on tourniquet application. This is more realistic than using a block of wood to act as a limb, which is often how training is conducted today. Combining the manikin arm with the PDA allows instructors to provide scenario based training. In a classroom or field setting, an instructor can specify wound variables such as location, casualty size, and whether the wound is a tough bleed. The PDA also allows more detailed feedback to be provided. Finally, combining the manikin arm with game-based technologies, the third component, provides opportunities to build knowledge and to practice battlefield decision making. Not only do soldiers learn how to apply a tourniquet, but when to apply a tourniquet in combat. The purpose of the paper is to describe the learning science underlying the design of HapMed, illustrate the training system and ways it is being expanded to encompass other critical life-saving tasks, and report on feedback received from instructors and trainees at military training and simulation centers.

Fowlkes, Jennifer↗

Ischemia causes muscle fatigue

The purpose of this investigation was to determine whether ischemia, which reduces oxygenation in the extensor carpi radialis (ECR) muscle, causes a reduction in muscle force production. In eight subjects, muscle oxygenation (TO2) of the right ECR was measured noninvasively and continuously using near infrared spectroscopy (NIRS) while muscle twitch force was elicited by transcutaneous electrical stimulation (1 Hz, 0.1 ms). Baseline measurements of blood volume, muscle oxygenation and twitch force were recorded continuously, then a tourniquet on the upper arm was inflated to one of five different pressure levels: 20, 40, 60 mm Hg (randomized order) and diastolic (69 +/- 9.8 mm Hg) and systolic (106 +/- 12.8 mm Hg) blood pressures. Each pressure level was maintained for 3-5 min, and was followed by a recovery period sufficient to allow measurements to return to baseline. For each respective tourniquet pressure level, mean TO2 decreased from resting baseline (100% TO2) to 99 +/- 1.2% (SEM), 96 +/- 1.9%, 93 +/- 2.8%, 90 +/- 2.5%, and 86 +/- 2.7%, and mean twitch force decreased from resting baseline (100% force) to 99 +/- 0.7% (SEM), 96 +/- 2.7%, 93 +/- 3.1%, 88 +/- 3.2%, and 86 +/- 2.6%. Muscle oxygenation and twitch force at 60 mm Hg tourniquet compression and above were significantly lower (P < 0.05) than baseline value. Reduced twitch force was correlated in a dose-dependent manner with reduced muscle oxygenation (r = 0.78, P < 0.001). Although the correlation does not prove causation, the results indicate that ischemia leading to a 7% or greater reduction in muscle oxygenation causes decreased muscle force production in the forearm extensor muscle. Thus, ischemia associated with a modest decline in TO2 causes muscle fatigue.

Non-NASA Center↗

Compartment syndrome of the thigh complicating surgical treatment of ipsilateral femur and ankle fractures

A 26-year-old man presented with ipsilateral femur and ankle fractures. The patient was treated with interlocking nail of his femur fracture, followed by open reduction and internal fixation of his ankle fracture under tourniquet control. Postoperatively, the patient developed compartment syndrome of his thigh with elevated pressures, requiring decompressive fasciotomies. This case illustrates the possible complication of treating a femur fracture with intramedullary nailing and then immediately applying a tourniquet to treat an ipsilateral extremity fracture. Because of the complication with this patient, we feel the procedure should be staged, or a tourniquet should be avoided if possible.

Case Reports↗

Supervisory Algorithm for Autonomous Hemodynamic Management Systems

Future military conflicts will require new solutions to manage combat casualties. The use of automated medical systems can potentially address this need by streamlining and augmenting the delivery of medical care in both emergency and combat trauma environments. However, in many situations, these systems may need to operate in conjunction with other autonomous and semi-autonomous devices. Management of complex patients may require multiple automated systems operating simultaneously and potentially competing with each other. Supervisory controllers capable of harmonizing multiple closed-loop systems are thus essential before multiple automated medical systems can be deployed in managing complex medical situations. The objective for this study was to develop a Supervisory Algorithm for Casualty Management (SACM) that manages decisions and interplay between two automated systems designed for management of hemorrhage control and resuscitation: an automatic extremity tourniquet system and an adaptive resuscitation controller. SACM monitors the required physiological inputs for both systems and synchronizes each respective system as needed. We present a series of trauma experiments carried out in a physiologically relevant benchtop circulatory system in which SACM must recognize extremity or internal hemorrhage, activate the corresponding algorithm to apply a tourniquet, and then resuscitate back to the target pressure setpoint. SACM continues monitoring after the initial stabilization so that additional medical changes can be quickly identified and addressed, essential to extending automation algorithms past initial trauma resuscitation into extended monitoring. Overall, SACM is an important step in transitioning automated medical systems into emergency and combat trauma situations. Future work will address further interplay between these systems and integrate additional medical systems.

42 ENGINEERING↗

Tissue fluid pressures - From basic research tools to clinical applications

This paper describes clinical applications of two basic research tools developed and refined in the past 20 years: the wick catheter (for measuring tissue fluid pressure) and the colloid osmometer (for measuring osmotic pressure). Applications of the osmometer include estimations of the reduced osmotic pressure of sickle-cell hemoglobin with deoxygenation, and of reduced swelling pressure of human nucleus pulposus with hydration or upon action of certain enzymes. Clinical uses of the wick-catheter technique include an improvement of diagnosis and treatment of acute and chronic compartment syndromes, the elucidation of the tissue pressure thresholds for neuromuscular dysfunction, and the development of a better tourniquet for orthopedics.

Hargens, Alan R.↗

Intramuscular pressure varies with depth. The tibialis anterior muscle studied in 12 volunteers

Pressures in the tibialis anterior muscle were recorded at rest and during exercise with transducer-tipped catheters in 12 volunteers while they were supine or standing. The recordings were repeated with venous stasis created by an inflated tourniquet cuff on the thigh. Catheters were placed at 3 different sites in the muscle: catheter I adjacent to the deep surface of the fascia over the anterior compartment; catheter II between the fascia and the central tendon; and catheter III deep in the muscle close to the interosseous membrane. In both the supine and standing positions the intramuscular pressure at rest and the muscle relaxation pressure during exercise, obtained by catheter II, were greater than the corresponding pressures measured by the superficially located catheter I in the normal as well as in the volume loaded limb. The same conditions for pressure measurement consistently revealed lower pressures recorded by catheter III compared to II, but the difference was not significant. Our results indicate that intramuscular pressure increases centripetally, as the centrally lying tendon is approached. We conclude that pressure measurements for diagnosis of acute and chronic compartment syndromes and in ergonomic studies should be based on recordings from a standard location of the catheter within the muscle and a standard posture of the subject.

NASA Discipline Musculoskeletal↗

Neuromuscular Adaptations to Reduced Use

This viewgraph presentation reviews the studies done to reduce neuromuscular strength loss during unilateral lower limb suspension (ULLS). Since there are animals that undergo fairly long periods of muscular disuse without any or minimal muscular atrophy, there is an answer to that might be applicable to human in situations that require no muscular use to diminish the effects of muscular atrophy. Three sets of ULLS studies were reviewed indicated that muscle strength decreased more than the muscle mass. The study reviewed exercise countermeasures to combat the atrophy, including: ischemia maintained during Compound muscle action potential (CMAP), ischemia and low load exercise, Japanese kaatsu, and the potential for rehabilitation or situations where heavy loading is undesirable. Two forms of countermeasures to unloading have been successful, (1) high-load resistance training has maintained muscle mass and strength, and low load resistance training with blood flow restriction (LL(sub BFR)). The LL(sub BFR) has been shown to increase muscle mass and strength. There has been significant interest in Tourniquet training. An increase in Growth Hormone(GH) has been noted for LL(sub BFR) exercise. An experimental study with 16 subjects 8 of whom performed ULLS, and 8 of whom performed ULLS and LL(sub BFR) exercise three times per week during the ULLS. Charts show the results of the two groups, showing that performing LL(sub BFR) exercise during 30 days of ULLS can maintain muscle size and strength and even improve muscular endurance.

Ploutz-Snyder, Lori↗

Effects of forearm bier block with bretylium on the hemodynamic and metabolic responses to handgrip

We tested the hypothesis that a reduction in sympathetic tone to exercising forearm muscle would increase blood flow, reduce muscle acidosis, and attenuate reflex responses. Subjects performed a progressive, four-stage rhythmic handgrip protocol before and after forearm bier block with bretylium as forearm blood flow (Doppler) and metabolic (venous effluent metabolite concentration and (31)P-NMR indexes) and autonomic reflex responses (heart rate, blood pressure, and sympathetic nerve traffic) were measured. Bretylium inhibits the release of norepinephrine at the neurovascular junction. Bier block increased blood flow as well as oxygen consumption in the exercising forearm (P < 0.03 and P < 0.02, respectively). However, despite this increase in flow, venous K(+) release and H(+) release were both increased during exercise (P < 0.002 for both indexes). Additionally, minimal muscle pH measured during the first minute of recovery with NMR was lower after bier block (6.41 +/- 0.08 vs. 6.20 +/- 0.06; P < 0.036, simple effects). Meanwhile, reflex effects were unaffected by the bretylium bier block. The results support the conclusion that sympathetic stimulation to muscle during exercise not only limits muscle blood flow but also appears to limit anaerobiosis and H(+) release, presumably through a preferential recruitment of oxidative fibers.

Non-NASA Center↗

Intramuscular deoxygenation during exercise in patients who have chronic anterior compartment syndrome of the leg

Currently, the definitive diagnosis of chronic compartment syndrome is based on invasive measurements of intracompartmental pressure. We measured the intramuscular pressure and the relative oxygenation in the anterior compartment of the leg in eighteen patients who were suspected of having chronic compartment syndrome as well as in ten control subjects before, during, and after exercise. Chronic compartment syndrome was considered to be present if the intramuscular pressure was at least fifteen millimeters of mercury (2.00 kilopascals) before exercise, at least thirty millimeters of mercury (4.00 kilopascals) one minute after exercise, or at least twenty millimeters of mercury (2.67 kilopascals) five minutes after exercise. Changes in relative oxygenation were measured with use of the non-invasive method of near-infrared spectroscopy. In all patients and subjects, there was rapid relative deoxygenation after the initiation of exercise, the level of oxygenation remained relatively stable during continued exercise, and there was reoxygenation to a level that exceeded the pre-exercise resting level after the cessation of exercise. During exercise, maximum relative deoxygenation in the patients who had chronic compartment syndrome (mean relative deoxygenation [and standard error], -290 +/- 39 millivolts) was significantly greater than that in the patients who did not have chronic compartment syndrome (-190 +/- 10 millivolts) and that in the control subjects (-179 +/- 14 millivolts) (p < 0.05 for both comparisons). In addition, the interval between the cessation of exercise and the recovery of the pre-exercise resting level of oxygenation was significantly longer for the patients who had chronic compartment syndrome (184 +/- 54 seconds) than for the patients who did not have chronic compartment syndrome (39 +/- 19 seconds) and the control subjects (33 +/- 10 seconds) (p < 0.05 for both comparisons).

NASA Discipline Musculoskeletal↗