Search NASA⌕ Search

SEARCH · Search NASA

Results for “Trace contaminants”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Detection of trace contaminants released from rapidly heated pulsed power electrodes by laser diagnostics

Development of a capability to measure trace gas contaminants released from pulsed power electrodes would immediately impact Sandia pulsed power research. These releases occur during ultra-fast heating of metal electrodes during pulsed power discharges and can lead to substantial power losses through plasma formation. Detection of contaminants is a formidable challenge due to the need for in-situ spatially and temporally resolved measurements of trace gases in the extreme environment of ultra-fast heated metal surfaces. We investigate the feasibility of laser diagnostics for detecting contaminants, including H-atom, OH, and H 2 O. Laser-induced fluorescence and photofragmentation fluorescence showed significant plasma emission interferences and did not yield any detectable H-atom, OH, or H 2 O. Our newly developed H-atom detection using femtosecond degenerate four-wave mixing suppressed interferences and enabled detection of H-atoms. A few shots showed large signals in the near-surface region of metal foils, suggesting the formation of a wave of H-atoms from the metal.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation and mitigation of trace 210Pb contamination on copper surfaces

Clean materials are required to construct and operate many low-background physics experiments. High-purity copper has found broad use because of its physical properties and availability. In this paper, we describe methods to assay and mitigate Pb-210 contamination on copper surfaces, such as from exposure to environmental radon or coming from bulk impurities. We evaluated the efficacy of wet etching on commercial samples and observed that Po-210 contamination from the copper bulk does not readily pass into solution. During the etch, the polonium appears to trap at the copper-etchant boundary, such that it is effectively concentrated at the copper surface. We observed a different behavior for Pb-210; high-sensitivity measurements of the alpha emissivity versus time indicate the lowest level of Pb-210 contamination ever reported for a commercial copper surface: 0 +/- 12 nBq/cm2 (1-sigma). Additionally, we have demonstrated the effectiveness of mitigating trace Pb-210 and Po-210 surface backgrounds using custom, high-purity electroplating techniques. These approaches were evaluated utilizing assays performed with an XIA UltraLo-1800 alpha spectrometer.

radon, copper, copper cleaning, dark matter, Pb-21↗

Synergistically combining peracetic acid and reduced graphene oxide membranes to degrade trace organic contaminants

The removal of trace organic contaminants is a critical step for the reuse of municipal and industrial wastewater. Herein, we demonstrate a catalytic membrane platform synergistically integrating reduced graphene oxide (rGO) membranes and peracetic acid (PAA) oxidation, using a dye of methylene blue (MB) and a pesticide of 2,4-dichlorophenoxyacetic acid (2,4-D) as model contaminants. In a crossflow system with rGO membrane and 25 ppm PAA, the degradation rates of MB and 2,4-D were 22 and 0.12 g h −1 per g rGO, with an initial concentration of 10 and 1.1 ppm, respectively. The degradation time profile of MB and 2,4-D follows a pseudo-first-order model, and the degradation rate constant increases with increasing initial PAA doses. Here, the rGO membranes also exhibited good stability over a 1-month test for 2,4-D degradation. In addition to the nanofiltration performance of the rGO membrane, the integrated PAA-rGO membrane process shows great potential to degrade various organic contaminants without the need to separate and recover the metal-free catalyst in downstream treatment.

2,4-D↗

Magnetic-Core/Gold-Shell Nanoparticles for the Detection of Hydrophobic Chemical Contaminants

Magnetic-core/gold-shell nanoparticles (MAuNPs) are of interest for enabling rapid and portable detection of trace adulterants in complex media. Gold coating provides biocompatibility and facile functionalization, and a magnetic core affords analyte concentration and controlled deposition onto substrates for surface-enhanced Raman spectroscopy. Iron oxide cores were synthesized and coated with gold by reduction of HAuCl4 by NH2OH. MAuNPs were grafted with polyethylene glycol (PEG) and/or functionalized with 4-mercaptobenzoic acid (4-MBA) and examined using a variety of microscopic, spectroscopic, magnetometric, and scattering techniques. For MAuNPs grafted with both PEG and 4-MBA, the order in which they were grafted impacted not only the graft density of the individual ligands, but also the overall graft density. Significant Raman signal enhancement of the model analyte, 4-MBA, was observed. This enhancement demonstrates the functionality of MAuNPs in direct detection of trace contaminants. The magnetic deposition rate of MAuNPs in chloroform and water was explored. The presence of 4-MBA slowed the mass deposition rate, and it was postulated that the rate disparity originated from differing NP-substrate surface interactions. These findings emphasize the importance of ligand choice in reference to the medium, target analyte, and substrate material, as well as functionalization procedure in the design of similar sensing platforms.

36 MATERIALS SCIENCE↗

Circular Economy Contributions to Decarbonizing the US Steel Sector

The potential benefits of the circular economy (CE) for decarbonization have recently attracted much attention in the academic and grey literature. The department of energy (DOE) industrial decarbonization roadmap highlight that in addition to the four pillars (energy efficiency, electrification, low-carbon fuels, feedstocks, and energy sources, and carbon capture, utilization, and storage (CCUS)) identified in the roadmap, "scenarios [...] will need to be developed that incorporate materials efficiency and circular economy strategies". Moreover, the roadmap identifies hard-to-abate CO2 emissions across the five industrial subsectors included in the analysis (iron & steel, chemical, food & beverage, refining, and cement manufacturing). Thus, additional options to decarbonize the industrial sector, like the CE, could prove beneficial to address those hard-to-abate emissions. Moreover, they may be less costly, require less R&D or incentives, and be more readily adopted than other strategies such as energy efficiency and CCUS. While the Industrial Decarbonization Roadmap includes some CE strategies (e.g., the increasing market share of steel from electric arc furnaces - which incorporate steel scrap), a deeper dive into what role the CE could play in the United States (US) industrial decarbonization is needed. In this work, we present several industrial decarbonization scenarios that incorporate materials efficiency and circular economy strategies for the iron & steel subsector. The scenarios identify barriers (including technical limits and constraints), opportunities, and R&D needs.Moreover, we estimate the contribution of those scenarios to reducing the industrial sector's CO2 emissions and their potential synergies with the Industrial Decarbonization Roadmap's four pillars. Iron & steel manufacturing was responsible for 90 million tons of industrial CO2 emissions in 2020 - 7% of the industrial sector's total process- related emissions. Besides recycling - which presents technical limitations due to trace contaminants - CE strategies on the demand side could lower iron & steel manufacturing emissions (e.g., the development of lighter products or business models that encourage a more intensive use). This study reviews barriers, opportunities, and trade-offs for 5 material efficiency strategies. Many topics explored in the review call for further research.

barriers↗

Separation of rare earth element radioisotopes by reverse-phase high-speed counter-current chromatography

Analytical scale purification of rare earth element (REE) radioisotopes is typically accomplished using cation-exchange resins (e.g. AG 50W-X8) and high-performance liquid chromatography (HPLC). Despite the variety of improvements made since the development of this separation process in the 1950s, nearest neighbor separations remain a challenge, as does the issue of irreversible sample adsorption. Herein, we report a study that evaluates the potential of high-speed counter-current chromatography (HSCCC) as an alternative method for purifying REE elements, with specific reference to separations of fission product REE of interest to nuclear forensics. Complementary HSCCC REE separation experiments, one spiked with radiotracer and REE fission product activity, allowed for in depth analysis of resulting fractions from both an elemental (inductively coupled plasma atomic emission spectroscopy, ICP-AES) and radiological (gamma-ray spectrometry, beta counting) purity perspective. The highly reproducible nature of separation profiles generated from HSCCC instruments was leveraged to simplify work-up of samples containing radioisotopes. Subsequent radioanalytical evaluation revealed minimal carryover of Eu into neighboring Sm and Tb fractions (as indicated by presence of 150Eu), and trace contamination of the Tb fraction with Y (as indicated by presence of 91Y). Subtle differences in stationary phase retention across the two columns were reflected in significant variations in decontamination factors of duplicate parallel separations. Furthermore, these differences paired with obtained distribution of radioisotopes provided valuable insights into future improvements. Collectively, this study represents a significant step forward in development of HSCCC technology for task specific REE radioisotope purification.

07 ISOTOPE AND RADIATION SOURCES↗

Structures of two novel crystal forms of Aspergillus oryzae alpha amylase (taka-amylase)

The structures of Aspergillus oryzae α-amylase were determined in a tetragonal crystal, having one molecule as asymmetric unit, and a monoclinic crystal with two molecules as asymmetric unit. Both crystal forms were obtained from trace contaminants of an old commercial lipase preparation. Structures were determined and refined to 1.65 Å and 1.43 Å resolution respectively. The latter crystal has a non-crystallographic (NCS) twofold axis within the asymmetric unit. Glycosylation at Asn197 is evident, and in the tetragonal crystal can be seen to include three, partially disordered sugar residues following the initial N-acetyl glucosamine (NAG). Superposition of the tetragonal crystal model on the α-amylases from Bacillus subtilis (PDB:1BAG), pig pancreas (PDB:3L2L), and barley (PDB:1AMY), show a high degree of coincidence, particularly for the (β/α)8-barrel domains, and especially within the active site. Using this structural agreement between amylases, we extrapolated the binding model of a six residue, limit dextrin found in pig pancreas α-amylase to the A. oryzae enzyme model, which predicts substrate interacting amino acid residues.

59 BASIC BIOLOGICAL SCIENCES↗

Elemental analysis of air-sensitive frozen molten salt samples using an inert transfer chamber for LIBS/LA-ICP-TOF-MS analysis

A novel inert sample transfer system was developed and employed to enable, for the first time, the analysis of air-sensitive salt samples in a two-volume ablation cell using simultaneous laser-induced breakdown spectroscopy (LIBS) and laser ablation (LA)-inductively coupled plasma (ICP)-time-of-flight (TOF)-mass spectrometry (MS) analysis. Molten salts are of growing interest as a medium for advanced nuclear reactors and nuclear fuel reprocessing technologies continue to be developed around their use. However, compositional analysis of molten salt samples can be challenging because of their air-sensitive nature and varying solubilities leading to inaccurate measurements when digested. LA-based analysis provides an alternate method to digestion and can provide rapid elemental information with little sample preparation. In this study, LIBS and LA-ICP-TOF-MS were used to analyze the Ce content in frozen salt samples taken from a series of electrochemical experiments. Calibrations were built for each technique, and the resulting limits of detection for Ce were estimated to be 107 and 58 µg g −1 for LIBS and LA-ICP-TOF-MS, respectively. Test samples from the electrochemical experiments were analyzed using these calibrations. The results matched bulk digestion-based ICP-optical emission spectroscopy values, and daily trends in Ce concentration changes were identified. Additionally, the LIBS and LA-ICP-TOF-MS analysis was demonstrated for identifying microgram per gram levels of components and detecting trace contaminants. The impurities detected by LIBS included Al, Mg, Ca, and Na. The impurities detected by LA-ICP-TOF-MS included W, Ag, Al, Fe, Ni, Mo, Nd, Sm, Th, and U.

Andrews, Hunter B. [Oak Ridge National Laboratory ↗

Promise of nonthermal plasmas in addressing emerging environmental and health problems: Present and future

Nonthermal atmospheric pressure plasmas transform input electrical energy efficiently into reactive species, charged particles, and photons. This “activated gas” is being investigated as solutions for a range of environmental and health problems facing society today. In this Perspective, we take a cursory look at a few of these societal problems and the reflected role that plasmas may play in charting the pathway to a solution buoyed by supporting research. Here, we survey the plasma-based opportunities in the removal of trace contaminants in water supporting methodologies such as water reuse, which addresses scarcity and pollution, the opportunity posed by plasmas-based chemical depolymerization for plastics recycling, and the application of plasmas for food security, which includes sterilization of foodstuffs and the improvement of crop yield. Finally, we also included a short review on how plasmas may help control disease spread. In each case, the scope of the problem is presented along with the potential plasma-based solution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ion-capture electrodialysis using multifunctional adsorptive membranes

Technologies that can efficiently purify nontraditional water sources are needed to meet rising global demand for clean water. Water treatment plants typically require a series of costly separation units to achieve desalination and the removal of toxic trace contaminants such as heavy metals and boron. We report a series of robust, selective, and tunable adsorptive membranes that feature porous aromatic framework nanoparticles embedded within ion exchange polymers and demonstrate their use in an efficient, one-step separation strategy termed ion-capture electrodialysis. This process uses electrodialysis configurations with adsorptive membranes to simultaneously desalinate complex water sources and capture diverse target solutes with negligible capture of competing ions. Our methods are applicable to the development of efficient and selective multifunctional separations that use adsorptive membranes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Controlling saturation to improve per- and polyfluoroalkyl substance (PFAS) removal in biochar-amended stormwater bioretention systems

Black carbon-amended bioretention systems are an increasingly popular strategy for the removal of organic contaminants, including poly- and perfluoroalkyl substances (PFASs) and other trace organic contaminants (TOrCs), from urban stormwater. Many PFASs preferentially accumulate at the air–water interface, but detention time requirements for stormwater bioretention systems typically result in full saturation of the bioretention systems, effectively removing their air–water interfaces. This study assessed the effect of bioretention system saturation on removal of PFASs, metals, and hydrophilic TOrCs. A field-aged mixture of 40% v/v sand, 30% v/v zeolite, and 30% v/v biochar was packed into columns which were operated with hydraulic controls to remain unsaturated or fully saturated throughout the duration of the experiment. Twenty-four storm events sized to a 95th percentile storm at a California, United States military site were simulated using synthetic stormwater fortified with aqueous film forming foam-derived PFASs, TOrCs, and metals to mimic real-world conditions. Unsaturated conditions outperformed saturated conditions for removal of all PFASs analyzed. A simulated inadvertent system perturbation (i.e. flooding event) in the unsaturated columns did not result in significantly greater mobilization of PFAS mass, suggesting that more sorption to the biochar occurred as a result of the transient retention of PFASs at the air–water interface reducing kinetic sorption limitations. Overall, maintaining unsaturated conditions in a biofilter may extend the sorptive filter lifetime for PFASs by up to 83%. The results have implications for bioretention system application and design for PFAS removal in contaminated catchment areas.

13 HYDRO ENERGY↗

Multi-Constituent Airborne Contaminants Capture with Low Cost Oxide Getters and Mitigation of Cathode Poisoning in Solid Oxide Fuel Cell

The technical effort and scientific findings, discussed in this report, documents operational barriers and associated long term performance stability challenges posed by the presence of trace airborne multi-constituent contaminants present in high-temperature electrochemical systems, including Solid Oxide Fuel Cells (SOFCs), Solid Oxide Electrolysis Cells (SOECs), Ion Transport Membranes, and Gas Separation systems. Above systems, offering promises for cleanliness and energy efficiency, face challenges with electrode poisoning stemming from the presence of trace contaminants including gaseous Cr/B/Si vapors in the presence of intrinsic contaminants SO 2 /CO 2 /H 2 O gases. The study indicates that the long-term electrical performance degradation in SOFC systems can be traced to electrochemical, structural, and mechanical changes across cell, stack, and balance of plant components resulting from interactions with trace contaminants leading to increase in both ohmic and non-ohmic polarizations. The degradation primarily results from solid-state and gas-phase materials migration, electrode poisoning, and interactions at the cell and stack levels. Cathode degradation emerges as a significant factor impacting overall SOFC performance, especially related to the presence of intrinsic and extrinsic airborne impurities such as SOx, CrOx(OH)y, SOx, Si(OH)x, and HBOx. Although at trace levels, prolong systems operation at higher airflow (3-10X stoichiometric) allow the accumulation of contaminants within the cell components leading to electrical performance degradation through poisoning and electrode deactivation.

20 FOSSIL-FUELED POWER PLANTS↗

Surface Processes Control the Fate of Reactive Oxidants Generated by Electrochemical Activation of Hydrogen Peroxide on Stainless-Steel Electrodes

Low-cost stainless-steel electrodes can activate hydrogen peroxide (H 2 O 2 ) by converting it into a hydroxyl radical ( • OH) and other reactive oxidants. At an applied potential of +0.020 V, the stainless-steel electrode produced • OH with a yield that was over an order of magnitude higher than that reported for other systems that employ iron oxides as catalysts under circumneutral pH conditions. Decreasing the applied potential at pH 8 and 9 enhanced the rate of H 2 O 2 loss by shifting the process to a reaction mechanism that resulted in the formation of an Fe(IV) species. Significant metal leaching was only observed under acidic pH conditions (i.e., at pH <6), with the release of dissolved Fe and Cr occurring as the thickness of the passivation layer decreased. Despite the relatively high yield of • OH production under circumneutral pH conditions, most of the oxidants were scavenged by the electrode surface when contaminant concentrations comparable to those expected in drinking water sources were tested. The stainless-steel electrode efficiently removed trace organic contaminants from an authentic surface water sample without contaminating the water with Fe and Cr. With further development, stainless-steel electrodes could provide a cost-effective alternative to other H 2 O 2 activation processes, such as those by ultraviolet light.

42 ENGINEERING↗