Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transducers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Pressure Transducer Measurement Variability in Deep Wells Screened Across the Water Table

Abstract Automated water level measurements collected using vented pressure transducers in deep wells screened across the water table may exhibit a greater response to barometric pressure changes than the true water level. The cause was hypothesized to be disequilibrium in barometric pressure between the wellbores and land surface due to air exchange with the deep vadose zone. In this study, vented and nonvented pressure transducers were installed and operated simultaneously in two deep wells screened across the water table. A vent tube open to the atmosphere at land surface allowed for barometric compensation of the vented transducers. Two nonvented transducers were installed in each well, one submerged in the water and one above the water surface. The difference in readings allowed for barometric compensation. Manual measurements were also collected. It was confirmed that measurements from the vented transducers exhibited greater variability in response to barometric pressure changes than the nonvented transducers and manual measurements. Comparison of the downhole barometric pressure measurements to values from a nearby meteorology station showed the response in the wells to changes in barometric pressure was time‐lagged and attenuated. Thus, the reference pressure from land surface supplied to the vented transducers was not representative of the air pressure within the wells. This caused fluctuations of the transducer readings in response to barometric pressure changes to be greater than the true water level change. This issue can be resolved by the use of nonvented pressure transducers.

McDonald, John P.↗

Final Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have developed a continuum electromechanics model of the microwave resonant cavity transducer performance. The deflection of the membrane is calculated using equations from the theory of plates and shells for deflection of radially constrained thin circular disk under uniform load. The microwave frequency shift is calculated using the equations from the microwave cavity perturbation theory. The transducer model was validated with proof-of-concept experimental data of water flow sensing with a Brass 360 right circular cylinder with 22.2mm diameter and 203µm thick wall. The cavity was excited through a subwavelength hole in TE 011 mode with resonant frequency f ≈ 17.8GHz. Subsequently, we have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment. For this test, we have developed a cylindrical resonator with the same dimensions as for the Brass 360 cavity. The resonator for high temperature liquid sodium test was machined from stainless steel 316 and electroplated with silver on the interior surfaces. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. The sodium flow sensing study was performed in a liquid sodium vessel at 340°C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred kHz was observed. The transducer was removed after 70 days of testing. No visual damage was observed, and the electromagnetic response remained the same. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Water flow sensing was performed before and after liquid sodium test. The responses in both cases are similar and agree with COMSOL computer simulations. Because long-term (multi-year) experimental tests of transducer resilience to harsh environment are not practical, we have developed a probabilistic model of creep to estimate transducer resilience to the harsh environment. The probabilistic model considers diffusion creep under the condition of high temperature and low stress, where the stress and temperature are allowed to be random variables with Gaussian distributions. Using the probabilistic model, we estimate inelastic membrane deflections due to creep for several temperature ranges. We conclude that for temperatures less than 650°C, creep has negligible long-term effect on the transducer performance.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effect of sintering temperature on adhesion of spray-on piezoelectric transducers

Conventionally sol-gel spray-on transducers require a high-temperature (> 700 ◦C) sintering process; however, this process can affect the microstructure of the substrate material. For mechanical elbows and valves utilized for fluid transport in the energy sector, the components are designed to have a specific microstructure, and deviations from these specifications can create weak points in the system. For this reason it is important to investigate how the temperature of the deposition process affects the substrate. This paper investigates the effect of high-temperature and low-temperature (< 150 ◦C) processing conditions on the surface composition of the substrate. Furthermore, the resultant transducers from high- and low-temperature fabrication processes are compared to determine if a low-temperature processing method is feasible. For these studies a sol-gel spray-on process is employed to deposit piezoelectric ceramics onto a stainless-steel 316L substrate. Energy-dispersive X-ray spectroscopy is utilized to determine the composition of the substrate surface before and after transducer deposition. Results indicate that the high-temperature processing conditions may alter the surface composition of the metal due to a diffusion of the metal into the ceramic, which results in a metal surface that is bonded to the ceramic. Furthermore, it is shown that low-temperature processing of spray-on transducers is a viable method for transducer fabrication where the resultant transducers meet the industry minimum requirement of 30 dB signalto-noise ratio. In parallel simulation calculations, finite-element method (FEM) studies were performed to model the adhesive strength of the low-temperature processed transducer to the substrate surface. Comparisons between the simulations and experiments suggest that the bond strength is much greater than the commercial gel bonds and closer to hardened epoxy glue bonds. These results indicate that spray-on transducers fabricated under lowtemperature processing conditions are a viable solution for leave-in-place monitoring of structures.

M. Sinding, Kyle↗

Second Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. Because the transducer is intended for immersion in a high temperature corrosive fluid, understanding of material degradation is crucial for estimation of transducer performance lifetime, and development of measurement interpretation algorithms. We conducted a preliminary computational investigation of relevant damage mechanisms of a stainless steel 316 cylindrical resonator in FLiBe salt. The two main damage mechanisms, creep and corrosion, were modeled using multiphysics COMSOL software. Degradation was modeled for a temperature range 500°C to 700°C. Coupling of the damage mechanisms was not considered. These models predict significant inelastic deformation at most temperatures due to creep, and qualitatively predict chromium depletion both along the liquid/solid interface and along the grain boundaries. An algorithmic approach for compensation of these degradation effects during fluid flow measurements will be developed in the future work. To validate sensor physics, we have performed proof-of-principle test of flow sensing in water. For this test, we have developed a cylindrical resonator for K-band, which was machined from brass. The cavity was excited through WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder. To increase the spectral signal visibility, we developed a signal processing method for baseline subtraction. A flow loop for proof-of-principle test of transducer performance in water was assembled. A commercial flow meter was installed in the loop for reference measurements. Cylindrical cavity was excited in the TE 011 mode with resonant frequency f ≈ 17.8GHz. Frequency shift of cavity spectral response was obtained by gradually increasing water flow rate from 0 to 60gpm. Corresponding monotonic increase of resonant frequency shift by several MHz was observed. Approximate figure of merit of sensitivity to flow rate is 100KHz/GPM. In addition, we have identified an existing liquid sodium experimental setup for demonstration of flow sensing in environment similar to that of an advanced reactor. The setup consists of a cylindrical vessel and center feed line, where transducer inserted through the lid will measure velocity of the impinging liquid jet. As a calibration experiment, we have assembled a water vessel with center feed with the same dimensions as those of the liquid sodium setup. We have also developed and insertion probe consisting of a 50cm brass waveguide enclosed in protective SS316 tube. Using the water loop, we have demonstrated feasibility of sensing the impinging liquid jet in the vessel.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Progress Towards Developing Neutron Tolerant Magnetostrictive and Piezoelectric Transducers

Current generation light water reactors (LWRs), sodium cooled fast reactors (SFRs), small modular reactors (SMRs), and next generation nuclear plants (NGNPs) produce harsh environments in and near the reactor core that can severely tax material performance and limit component operational life. To address this issue, several Department of Energy Office of Nuclear Energy (DOE-NE) research programs are evaluating the long duration irradiation performance of fuel and structural materials used in existing and new reactors. In order to maximize the amount of information obtained from Material Testing Reactor (MTR) irradiations, DOE is also funding development of enhanced instrumentation that will be able to obtain in-situ, real-time data on key material characteristics and properties, with unprecedented accuracy and resolution. Such data are required to validate new multi-scale, multi-physics modeling tools under development as part of a science-based, engineering driven approach to reactor development. It is not feasible to obtain high resolution/microscale data with the current state of instrumentation technology. However, ultrasound-based sensors offer the ability to obtain such data if it is demonstrated that these sensors and their associated transducers are resistant to high neutron flux, high gamma radiation, and high temperature. To address this need, the Advanced Test Reactor National Scientific User Facility (ATR-NSUF) is funding an irradiation, led by PSU, at the Massachusetts Institute of Technology Research Reactor to test the survivability of ultrasound transducers. As part of this effort, PSU and collaborators have designed, fabricated, and provided piezoelectric and magnetostrictive transducers that are optimized to perform in harsh, high flux, environments. Four piezoelectric transducers were fabricated with either aluminum nitride, zinc oxide, or bismuth titanate as the active element that were coupled to either Kovar or aluminum waveguides and two magnetostrictive transducers were fabricated with Remendur or Galfenol as the active elements. Pulse-echo ultrasonic measurements of these transducers are made in-situ. This paper will present an overview of the test design including selection criteria for candidate materials and optimization of test assembly parameters, data obtained from both out-of-pile and in-pile testing at elevated temperatures, and an assessment based on initial data of the expected performance of ultrasonic devices in irradiation conditions

Reinhardt1, Brian↗

Transducer Resolution Effect on Pressure Fluctuations Beneath Hypersonic Turbulent Boundary Layers

The size of a pressure transducer is known to affect the accuracy of measurements of wall-pressure fluctuations beneath a turbulent boundary layer because of spatial averaging over the sensing area of the transducer. In this paper, the effect of finite transducer size is investigated by applying spatial averaging or wavenumber filters to a database of hypersonic wall pressure generated from a direct numerical simulation (DNS) that simulates the turbulent portion of the boundary layer over a sharp 7° half-angle cone at nominally Mach 8. Here, a good comparison between the DNS and the experiment in the Sandia Hypersonic Wind Tunnel at Mach 8 is achieved after spatial averaging is applied to the DNS data over an area similar to the sensing area of the transducer. The study shows that a finite sensor size similar to that of the PCB132 transducer can cause significant attenuation in the root-mean-square and power spectral density (PSD) of wall-pressure fluctuations, and the attenuation effect is identical between cone and flat plate configurations at the same friction Reynolds number. The Corcos theory is found to successfully compensate for the attenuated high-frequency components of the wall-pressure PSD.

42 ENGINEERING↗

General Testing Setup for Hyperelastic Transducers-DEEC-Tec & Marine Renewable Energy: Preprint

Distributed embedded energy conversion technologies (DEEC-Tec), an emerging domain for ocean wave energy conversion technology, is showing promise for a range of applications. Research is being conducted at the National Renewable Energy Laboratory that leverages this domain to investigate the potential of ocean wave energy converters (WECs) constructed from hyperelastic forms of distributable and embeddable energy transducers. These transducers are available in forms such as disks, rectangles, or hexagons and can be combined in various ways to form energy-producing metamaterials and flexible WECs. DEEC-Tec, therefore, could open doors that enhance ocean wave energy conversion in ways not previously thought possible by allowing for many WEC topologies and morphologies. However, the same diversity and adaptability pose challenges for the development of these DEEC-Tec-oriented hyperelastic transducers. A commercial tensile testing setup was not found that was adaptable enough to accommodate the varied transducers while providing precise force control, range of motion, and noncontact data collection. Because of this lack, a comprehensive test rig was designed in house to be used with a 3D laser scanning device-providing contactless measurements while also allowing for different geometries and various uniaxial loadings. This paper and presentation will discuss these unique challenges and the processes for overcoming them to provide a robust and general testing setup for hyperelastic transducers, of any form, for the DEEC-Tec marine renewable energy domain.

DEEC-Tec↗

Quantum capacities of transducers

Abstract High-performance quantum transducers, which faithfully convert quantum information between disparate physical carriers, are essential in quantum science and technology. Different figures of merit, including efficiency, bandwidth, and added noise, are typically used to characterize the transducers’ ability to transfer quantum information. Here we utilize quantum capacity, the highest achievable qubit communication rate through a channel, to define a single metric that unifies various criteria of a desirable transducer. Using the continuous-time quantum capacities of bosonic pure-loss channels as benchmarks, we investigate the optimal designs of generic quantum transduction schemes implemented by transmitting external signals through a coupled bosonic chain. With physical constraints on the maximal coupling rate $${g}_{\max }$$ g max , the highest continuous-time quantum capacity $${Q}^{\max }\approx 31.4{g}_{\max }$$ Q max ≈ 31.4 g max is achieved by transducers with a maximally flat conversion frequency response, analogous to Butterworth electric filters. We further investigate the effect of thermal noise on the performance of transducers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Irradiation Testing of Ultrasonic Transducers

Ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of numerous parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of single, small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. Other efforts include an ultrasonic technique to detect morphology changes (such as crack initiation and growth) and acoustic techniques to evaluate fission gas composition and pressure. These efforts are limited by the lack of existing knowledge of ultrasonic transducer material survivability under irradiation conditions. To address this need, the Pennsylvania State University (PSU) was awarded an Advanced Test Reactor National Scientific User Facility (ATR NSUF) project to evaluate promising magnetostrictive and piezoelectric transducer performance in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 1021 n/cm2 (E> 0.1 MeV). This test will be an instrumented lead test; and real-time transducer performance data will be collected along with temperature and neutron and gamma flux data. By characterizing magnetostrictive and piezoelectric transducer survivability during irradiation, test results will enable the development of novel radiation tolerant ultrasonic sensors for use in Material and Test Reactors (MTRs). The current work bridges the gap between proven out-of-pile ultrasonic techniques and in-pile deployment of ultrasonic sensors by acquiring the data necessary to demonstrate the performance of ultrasonic transducers

Daw, J.↗

Analysis of Microwave Resonant Cavity Transducer Degradation Mechanisms

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. Because the transducer is intended for immersion in a high temperature corrosive fluid, understanding of material degradation is crucial for estimation of transducer performance lifetime, and development of measurement interpretation algorithms. We conducted a preliminary computational investigation of relevant damage mechanisms of a stainless steel 316 cylindrical resonator in FLiBe salt. The two main damage mechanisms, creep and corrosion, were modeled using multiphysics COMSOL software. Degradation was modeled for a temperature range 500°C to 700°C. Coupling of the damage mechanisms was not considered. These models predict significant inelastic deformation at most temperatures due to creep, and qualitatively predict chromium depletion both along the liquid/solid interface and along the grain boundaries. An algorithmic approach for compensation of these degradation effects during fluid flow measurements will be developed in the future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ultrasonic Transducer Irradiation Test Results

Ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. These efforts are limited by the lack of identified ultrasonic transducer materials capable of long term performance under irradiation test conditions. To address this need, the Pennsylvania State University (PSU) was awarded an Advanced Test Reactor National Scientific User Facility (ATR NSUF) project to evaluate the performance of promising magnetostrictive and piezoelectric transducers in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 1021 n/cm2 . A multi-National Laboratory collaboration funded by the Nuclear Energy Enabling Technologies Advanced Sensors and Instrumentation (NEET ASI) program also provided initial support for this effort. This irradiation, which started in February 2014, is an instrumented lead test and real-time transducer performance data are collected along with temperature and neutron and gamma flux data. The irradiation is ongoing and will continue to approximately mid-2015. To date, very encouraging results have been attained as several transducers continue to operate under irradiation.

Daw, Joshua↗

Light-induced microwave noise in superconducting microwave-optical transducers

Microwave-to-optical transducers are integral to the future of superconducting quantum computing, as they would enable scaling and long-distance communication of superconducting quantum processors through optical-fiber links. However, optically induced microwave noise poses a significant challenge in achieving quantum transduction between microwave and optical frequencies. In this work, we study light-induced microwave noise in an integrated electro-optical transducer harnessing the Pockels effect of thin-film lithium niobate. We reveal three sources of added noise with distinctive time constants ranging from sub-100 ns to milliseconds. Furthermore, our results provide insights into the mechanisms and corresponding mitigation strategies for light-induced microwave noise in superconducting microwave-optical transducers and pave the way toward realizing the ultimate goal of quantum transduction.

42 ENGINEERING↗

Generating Electricity with Hydraulically Amplified Self-Healing Electrostatic (HASEL) Transducers

This study identifies hydraulically amplified self-healing electrostatic (HASEL) transducers as electricity generators, contrary to their conventional role as actuators. HASELs are soft, variable-capacitance transducers inspired by biological muscles which were developed to mimic the flexibility and functionality of natural muscle tissues. This research characterizes HASELs as generators by reversing their energy conversion mechanism—generating electricity through mechanical deformation. The study assesses the practical laboratory performance of HASELs by analytic modeling and experimental evaluation. Outcomes of the study include the following: (i) up to 2.5 mJ per cycle per 50 mm wide HASEL pouch of positive net energy generation in experimental testing—corresponding to an energy density of 2.0 mJ cm−3; (ii) a maximum theoretical energy density of 4.2 mJ cm−3; (iii) the electromechanical characteristics governing efficient conversion; and (iv) design considerations to enhance HASEL generator performance in future applications. This study broadens HASEL’s applicability and utility as a multi-functional transducer for renewable energy and general adaptive electricity generation.

13 HYDRO ENERGY↗

Self-Sustainable IoT-Based Remote Sensing Powered by Energy Harvesting Using Stacked Piezoelectric Transducer and Thermoelectric Generator

We propose a self-powered remote multi-sensing system for traffic sensing which is powered by the collective energy harvested from the mechanical vibration of the road caused by the passing vehicles and from the temperature gradient between the asphalt of the road and the soil underneath. A stacked piezoelectric transducer converts mechanical vibrations into electrical energy and a thermoelectric generator harvests the thermal energy from the thermal gradient. Electrical energy signals from the stacked piezoelectric transducer and the thermoelectric generators are converted into usable DC power to recharge the battery using AC-DC and DC-DC converters working simultaneously. The multi-sensing system comprises an embedded system with a microcontroller that acquires data from the sensors and sends the sensory data to an IoT transceiver which transmits the data as RF packets to an ethernet gateway. The gateway converts the RF packets into Internet Protocol (IP) packets and sends them to a remote server. Laboratory and road-testing results showed over 98% sensory data accuracy with the system functioning solely powered by the energy harvested from the alternative energy sources. The successful maximum transmission distance obtained between the IoT, and the gateway was approximately 1 mile, which is a considerable transmission distance achieved in an urban environment. Successful operation of the self-powered multi-sensing system under both laboratory and road conditions contributes considerably to the fields of energy harvesting and self-powered remote sensing systems. The energy flow chart and efficiency for the steps in the system were found to be mechanical power from vehicles to the energy harvester of 0.25%, stacked PZT transducer efficiency was found to be 37%, and for the TEGs the efficiency is 11%. AC-to-DC and DC-to-DC converters’ efficiencies were found to be 90% and 11%. The wireless communication RF transceiver efficiency was found to be 62.5%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstration of Microwave Cavity Transducer Performance in High Temperature Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment, which is similar to that of an advanced reactor. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Outer diameter of the cylindrical cavity is approximately 3cm, and the thin wall is approximately 200µm thick. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Frequency shift of the cavity spectral response was obtained at room temperature and ambient pressure by gradually increasing water flow rate from 0 to 25GPM (gallons per minute). Corresponding monotonic increase of resonant frequency by several hundred KHz was observed. Next, a sodium flow rate sensing study was performed in a liquid sodium vessel at 340° C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of Microwave Resonant Cavity Transducer Recalibration Procedures

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Inner diameter of the cylindrical cavity is 22.2 mm, and the thin wall is approximately 200µm thick. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. Sodium flow rate sensing study was performed in a liquid sodium vessel at 340°C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed. From the measurements, we observed significant scatter in high temperature liquid sodium at low flow velocity values. Our hypothesis is that this is caused by temperature drift in the liquid, which results in thermal expansion of the cavity and a drift in the resonator frequency. In this report, we investigate temperature dependence of the resonant frequency through development of analytic models and preliminary analysis of experimental data. In addition, we develop a procedure for compensation for temperature drift during flow sensing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of electro-optical quantum transducers based on three-dimensional superconducting cavities

Quantum transducers enable the conversion of quantum information and signals between different physical platforms. Based on the pioneering works in three-dimensional superconducting cavity technology developed at Fermilab, we are advancing the development of three-dimensional microwave-optical transducers and exploring their applications in quantum information processing and sensing. We present our progress in the design, fabrication, and characterization of three-dimensional microwave cavities integrated with bulk lithium niobate resonators. The material characterization using three-dimensional cavities based on a resonant-type method allows for understanding of complex permittivity and loss mechanism of electro-optic materials at cryogenic temperatures. We also evaluate the potential of the high-efficiency quantum transducers in enhancing the performance of quantum sensors for applications such as dark matter detection, compared to conventional homodyne detection approaches. This manuscript has been authored by Fermi Research Alliance, LLC under Contract No. DE-AC0207CH11359 with the U.S. Department of Energy, Office of Science, Office of High Energy Physics. This work is funded by the DOE's Early Career Research Program. This research used resources of the U.S. Department of Energy, Office of Science, National Quantum Information Science Research Centers, Superconducting Quantum Materials and Systems Center (SQMS) under Contract No. DE-AC02-07CH11359.

Zorzetti, Silvia↗

Multiscale and multiphysics FEA simulation and materials optimization for laser ultrasound transducers

In this study, the relationship between the nanocomposite design and the laser ultrasound transducer (LUT) characteristics was investigated through simulations in multiple scale levels for material behavior, device response, and acoustic wave propagation in media. First, the effects of the nanoparticle size and concentration on the effective properties of composites were quantitatively investigated with the finite element analysis (FEA) method. Second, the effective properties of the nanocomposite were assigned to the layer, which is modeled as a homogeneous material, in the FEA for the LUT simulating the energy conversion from the incident laser to the acoustic wave. Finally, the ultrasound propagation in the water was calculated by a theoretical wave propagation model. The FEA-based prediction was compared with the experimental data in the literature and a theoretical analysis for LUT based on Thermal-Acoustic coupling. As a result, the ultrasound waves on the transducer surface and at a distance in the water could be predicted. Based on the hierarchically integrated prediction procedure, the optimal conditions of the photoacoustic nanocomposites were investigated through the parametric study with the particle size and concentration as variables. The results guide the material designs optimized for different device characteristics, such as high pressure and broad bandwidth.

36 MATERIALS SCIENCE↗