An approach to the determination of aircraft handling qualities by using pilot transfer functions
Transfer functions of pilot for determining longitudinal aircraft controllability and pilot performance prediction
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Transfer functions of pilot for determining longitudinal aircraft controllability and pilot performance prediction
A transfer function design theory for multivariable control synthesis is highlighted. The use of unique transfer function matrices and two simple, basic relationships - a synthesis equation and a design equation - are presented and illustrated. This multivariable transfer function approach provides the designer with a capability to specify directly desired dynamic relationships between command variables and controlled or response variables. At the same time, insight and influence over response, simplifications, and internal stability is afforded by the method. A general, comprehensive multivariable synthesis capability is indicated including nonminmum phase and unstable plants. Gas turbine engine examples are used to illustrate the ideas and method.
We present a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) one-dimensional sequences and two-dimensional arrays as an effective method for spectral characterization in the spatial frequency domain of a broad variety of metrology instrumentation, including interferometric microscopes, scatterometers, phase shifting Fizeau interferometers, scanning and transmission electron microscopes, and at this time, x-ray microscopes. The inherent power spectral density of BPR gratings and arrays, which has a deterministic white-noise-like character, allows a direct determination of the MTF with a uniform sensitivity over the entire spatial frequency range and field of view of an instrument. We demonstrate the MTF calibration and resolution characterization over the full field of a transmission soft x-ray microscope using a BPR multilayer (ML) test sample with 2.8 nm fundamental layer thickness. We show that beyond providing a direct measurement of the microscope’s MTF, tests with the BPRML sample can be used to fine tune the instrument’s focal distance. Our results confirm the universality of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.
Exact transfer function, ETF, is two-dimensional transfer function that constitutes basis of improved frequency-domain-convolution algorithm for processing synthetic-aperture-radar, SAR data. ETF incorporates terms that account for Doppler effect of motion of radar relative to scanned ground area and for antenna squint angle. Algorithm based on ETF outperforms others.
Transfer-function approximations made optimal in special least-squares sense. Algorithm computes reduced-order rational-fraction approximates to single-input/single-output transfer functions. Reduces amount of computation needed for such purposes as numerical simulation of dynamics and design of control subsystems.
Purpose: The modulation transfer function (MTF) of medical imaging devices is commonly reported in the form of orthogonal one-dimensional (1D) measurements made near the vertical and horizontal axes with a slit or edge test device. A more complete description is found by measuring the two-dimensional (2D) MTF. Some 2D test devices have been proposed, but there are some issues associated with their use: (1) they are not generally available; (2) they may require many images; (3) the results may have diminished accuracy; and (4) their implementation may be particularly cumbersome. This current work proposes the application of commonly available 1D test devices for practical and accurate estimation of the 2D presampled MTF of digital imaging systems. Methods: Theory was developed and applied to ensure adequate fine sampling of the system line spread function for 1D test devices at orientations other than approximately vertical and horizontal. Methods were also derived and tested for slit nonuniformity correction at arbitrary angle. Techniques were validated with experimental measurements at ten angles using an edge test object and three angles using a slit test device on an indirect-detection flat-panel system [GE Revolution XQ/i (GE Healthcare, Waukesha, WI)]. The 2D MTF was estimated through a simple surface fit with interpolation based on Delaunay triangulation of the 1D edge-based MTF measurements. Validation by synthesis was also performed with simulated images from a hypothetical direct-detection flat-panel device. Results: The 2D MTF derived from physical measurements yielded an average relative precision error of 0.26% for frequencies below the cutoff (2.5 mm{sup -1}) and approximate circular symmetry at frequencies below 4 mm{sup -1}. While slit analysis generally agreed with the results of edge analysis, the two showed subtle differences at frequencies above 4 mm{sup -1}. Slit measurement near 45 Degree-Sign revealed radial asymmetry in the MTF resulting from the square pixel aperture (0.2 mm Multiplication-Sign 0.2 mm), a characteristic which was not necessarily appreciated with the orthogonal 1D MTF measurements. In simulation experiments, both slit- and edge-based measurements resolved the radial asymmetries in the 2D MTF. The average absolute relative accuracy error in the 2D MTF between the DC and cutoff (2.5 mm{sup -1}) frequencies was 0.13% with average relative precision error of 0.11%. Other simulation results were similar to those derived from physical data. Conclusions: Overall, the general availability, acceptance, accuracy, and ease of implementation of 1D test devices for MTF assessment make this a valuable technique for 2D MTF estimation.
Beam transfer functions (BTF)s encapsulate the stability properties of charged particle beams. In general one excites the beam with a sinusoidal signal and measures the amplitude and phase of the beam response. Most systems are very nearly linear and one can use various Fourier techniques to reduce the number of measurements and/or simulations needed to fully characterize the response. Schottky noise is associated with the finite number of particles in the beam. This signal is always present. Since the Schottky current drives wakefields, the measured Schottky signal is influenced by parasitic impedances.
Ionospheric transfer function (ITF) algorithms determine the effects of the ionosphere on an electromagnetic (EM) radio-frequency (RF) signal as it propagates through. In this report, the Snell’s law shell (slab) model is outlined.
Ionospheric transfer function (ITF) algorithms determine the effects of the ionosphere on an electromagnetic (EM) radio-frequency (RF) signal as it propagates through. In this report, the Bouger’s law shell model is outlined. This ITF is very similar to the Snell’s Law Shell ITF; however, in this formulation, plasma parameters in the ionosphere are allowed to change radially. This algorithm is expressed in the frequency domain. In this way, it is applied as linear time invariant (LTI) filter function. Signals in this report are assumed to have only a single component (i.e. x, y or z in a rectangular coordinate system). Multi-component signals can be treated simply by applying the specific ITF to each component separately.
NERVA transfer functions evaluation by computer data processing, using Fourier algorithm
Transfer function simulator constructed from analog or both analog and digital components substitute for device that has faults that confound analysis of feedback control loop. Simulator is substitute for laser and spectrophone.
N/A
A method for transfer function identification, including both model structure determination and parameter estimation, was developed and demonstrated. The approach uses orthogonal modeling functions generated from frequency domain data obtained by Fourier transformation of time series data. The method was applied to simulation data to identify continuous-time transfer function models and unsteady aerodynamic models. Model fit error, estimated model parameters, and the associated uncertainties were used to show the effectiveness of the method for identifying accurate transfer function models from noisy data.
Measuring human transfer functions - determination of variable gains using analog autopilot and human pilot operating flight simulator controls
The focus of the Offshore Code Comparison Collaboration, Continuation, with Correlation and unCertainity (OC6) project, which operates under the International Energy Agency (IEA) Wind Task 30, is to refine the accuracy of engineering tools used to design offshore wind turbines. In support of this work, a new validation campaign is being developed that seeks to better understand the nonlinear wave loading that excites floating wind systems at their low-frequency, rigid-body modes in surge and pitch. The validation data will be used in a three-way validation between simplified engineering tools and higher-fidelity tools, such as computational fluid dynamics (CFD). Irregular wave spectrums, which are traditionally used to examine the nonlinear wave interaction with offshore structures, are too computationally expensive to be simulated in CFD tools, and so bichromatic wave cases will be used instead. This paper reviews the process used to choose the bichromatic wave pairs to be used in the campaign to validate the second-order difference-frequency quadratic and potential loads at the surge and pitch natural frequencies of a floating semisubmersible.
The bright field contrast transfer function is one of the most useful concepts in conventional transmission electron microscopy. However, the electron Ronchigram contrast transfer function, as derived by Cowley, is inherently more complicated since it is not isoplanatic. Here, we derive a local contrast transfer function for small patches in a Ronchigram and demonstrate its utility for the direct measurement of aberrations from single Ronchigrams of an amorphous film. We describe the measurement of aberrations from both simulated and experimental images and elucidate the effects due to higherorder aberrations, separating those arising from the pre- and post-sample optics, and partial coherence.
Frequency transfer function applied to space vehicle structural analysis
A transfer function vibration test was made on an 80 ton open hopper freight car in an effort to obtain validation data on the car's nonlinear elastic model. Test configuration, handling, test facilities, test operations, and data acquisition/reduction activities necessary to meet the conditions of test requirements are given.