Determination of the pitch of a cholesteric liquid crystal by infrared transmission measurements
Infrared transmission measurement of pitch of cholesteric liquid crystal
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Infrared transmission measurement of pitch of cholesteric liquid crystal
A novel waveguide power transmission measurement technique was developed to extract the complex conductivity of superconducting thin films at microwave frequencies. The microwave conductivity was taken of two laser ablated YBa2Cu3O(7-delta) thin films on LaAlO3 with transition temperatures of approx. 86.3 and 82 K, respectively, in the temperature range 25 to 300 K. From the conductivity values, the penetration depth was found to be approx. 0.54 and 0.43 micron, and the surface resistance (R sub s) to be approx. 24 and 36 micro-Ohms at 36 GHz and 76 K for the two films under consideration. The R sub s values were compared with those obtained from the change in the Q-factor of a 36 GHz Te sub 011-mode (OFHC) copper cavity by replacing one of its end walls with the superconducting sample. This technique allows noninvasive characterization of high transition temperature superconducting thin films at microwave frequencies.
A novel waveguide power transmission measurement technique was developed to extract the complex conductivity of superconducting thin films at microwave frequencies. The microwave conductivity was taken of two laser ablated YBa2Cu3O(7-delta) thin films on LaAlO3 with transition temperatures of approximately 86.3 and 82 K, respectively, in the temperature range 25 to 300 K. From the conductivity values, the penetration depth was found to be approximately 0.54 and 0.43 micron, and the surface resistance (R sub s) to be approximately 24 and 36 micro-Ohms at 36 GHz and 76 K for the two films under consideration. The R sub s values were compared with those obtained from the change in the Q-factor of a 36 GHz Te sub 011-mode (OFHC) copper cavity by replacing one of its end walls with the superconducting sample. This technique allows noninvasive characterization of high transition superconducting thin films at microwave frequencies.
Cholesteric liquid crystal pitch from IR transmission measurements
Spectral transmission measurements were performed at 300 K in the 8.65-micron fundamental band of monodeuterated methane, a trace constituent in the atmosphere of Jupiter. A theoretical curve is obtained from line-by-line computation of the spectral transmission utilizing a triangular slit function with full width at half-maximum. The agreement between theoretical and experimental spectral transmission curves suggests that deuteration does not affect the collision-broadened half-widths significantly in the two extreme cases of broadening being considered.
This report describes measurements to determine transmission losses in S-band (2.60-3.95 GHz) waveguide sections due to misalignment of the sections relative to each other. The experiments were performed in support of the Hydrostar program to determine the feasibility of using deployable waveguide sections in a large space radiometer. The waveguide sections would possibly be hinged and folded for launch, then deployed in space to form long sections of waveguide. Since very low losses are required for radiometer applications, the effects of potential misalignment after deployment of the waveguide sections may be significant. These measurements were performed in the Electromagnetic Properties Measurement Laboratory in the Electromagnetics Research Branch.
Satellite transmissions were simulated by placing an 869 MHz and a 1501 MHz transmitter aboard a stratospheric balloon. The balloon was followed on the ground by a van equipped with receivers and data acquisition equipment capable of creating a permanent record of the variations of the received signal amplitude and phase at the two signal frequencies. Results from simulated satellite transmission measurements at 869 MHz are presented. The data show that attenuation by roadside trees can be a limiting factor in systems with a 5 dB fade margin, if 84% availability is not acceptable. In less extreme environments, fading is much less severe. Without fading present, the signal power density function often could be described as Ricean with direct to scattered ratio power ratios of about 100. Phase fluctuations were apparent whenever the signal amplitude fluctuated. The duration of the fades and nonfades tended to cluster close to one wavelength. The power spectrum of both the amplitude and the phase show that most of the fluctuations occur at frequencies below the Doppler shift.
The wavelength-dependent aerosol extinction in the 800-1250-cm(-1) region has been derived from ATMOS (atmospheric trace molecule spectroscopy) high-spectral-resolution IR transmission measurements.
The penetration depth of low-energy heavy ions in botanic samples was detected with a new transmission measurement. In the measurement, highly oriented pyrolytic graphite (HOPG) pieces were placed behind the botanic samples with certain thickness. During the irradiation of heavy ions with energy of tens of keV, the energetic particles transmitted from those samples were received by the HOPG pieces. After irradiation, scanning tunneling microscope (STM) was applied to observe protrusion-like damage induced by these transmitted ions on the surface of the HOPG. The statistical average number density of protrusions and the minimum transmission rate of the low-energy heavy ions can be obtained. The detection efficiency of the new method for low-energy heavy ions was about 0.1-1 and the background in the measurement can be reduced to as low as 1.0 x 10(8) protrusions/cm2. With this method, the penetration depth of the energetic particles was detected to be no less than 60 micrometers in kidney bean slices when the slices were irradiated by 100 keVAr+ ion at the fluence of 5 x 10(16) ions/cm2. c2002 Elsevier Science Ltd. All rights reserved.
A four-channel laser transmissometer has been used to probe the soot content of the exhaust plume of the X-34 60k-lb thrust Fastrac rocket engine at NASA's Marshall Space Flight Center. The transmission measurements were made at an axial location approximately equal 1.65 nozzle diameters from the exit plane and are interpreted in terms of homogeneous radial zones to yield extinction coefficients from 0.5-8.4 per meter. The corresponding soot mass density, spatially averaged over the plume cross section, is, for Rayleigh particles, approximately equal 0.7 microgram/cc, and alternative particle distributions are briefly considered. Absolute plume radiance at the laser wavelength (515 nm) is estimated from the data at approximately equal 2,200 K equivalent blackbody temperature, and temporal correlations in emission from several spatial locations are noted.
A four-channel laser transmissometer has been used to probe the soot content of the exhaust plume of the X-34 60k-lb thrust Fastrac rocket engine at NASA's Marshall Space Flight Center. The transmission measurements were made at an axial location about equal 1.65 nozzle diameters from the exit plane and are interpreted in terms of homogeneous radial zones to yield extinction coefficients from 0.5-8.4 per meter. The corresponding soot mass density, spatially averaged over the plume cross section, is, for Rayleigh particles, approximately equal to 0.7 micrograms/cubic cm and alternative particle distributions are briefly considered. Absolute plume radiance at the laser wavelength (515 nm) is estimated from the data at approximately equal to 2.200 K equivalent blackbody temperature, and temporal correlations in emission from several spatial locations are noted.
Coincidence counts yield absolute efficiencies. System measures mass-dependent transmission efficiencies of mass spectrometers, using coincidence-counting techniques reminiscent of those used for many years in calibration of detectors for subatomic particles. Coincidences between detected ions and electrons producing them counted during operation of mass spectrometer. Under certain assumptions regarding inelastic scattering of electrons, electron/ion-coincidence count is direct measure of transmission efficiency of spectrometer. When fully developed, system compact, portable, and used routinely to calibrate mass spectrometers.
Electron energy spectra construction from Al, Sn and Au target layers transmission angular distribution measurements, using computer calculated spectra for comparison
Spectral transmission of IR radiation through the nitrogen-broadened lines of the nu-3 fundamental of N2O has been measured at 154, 202 and 300 K. A value of 1411 + or - 54 per sq cm per atmosphere at STP has been obtained for the combined strength of the nu-3 and nu-2(1) + nu-3 - nu-2(1) bands, using the Wilson-Wells-Penner-Weber method. This value of the combined strength, the relative intensity calculations of Gray Young, the room-temperature data of Toth for nitrogen-broadened half-widths in the nu-1 + nu-3 and 2nu2(0) + nu-3 bands, and the variation of the line width with temperature proposed by Varanasi and Sarangi are shown to yield excellent agreement between the measured and computed spectral transmittance throughout the band.
Proportional velocity of pressure and sound in rocks by pulse transmission methods, determining time delay by means of frequency counter
An evaluation is made of results of recent experimental work concerning the effects that atmospherically induced fluctuations and temporal correlations have on the accuracy of atmospheric laser transmission experiments. These experiments directly measured the limitations of signal averaging as a means to the reduction of the standard deviation of laser signals which are backscattered from either a specular or a diffusely reflecting target, by means of both heterodyne and direct detection systems. These limitations are shown to agree with a theory in which the observed, atmospherically induced temporal correlation is taken into account.
This paper describes measurements which were performed on a sample of radome material in the Electromagnetic Properties Measurements Laboratory (EPML). The purpose of the measurements described in this paper was to determine the one-way transmission loss through the flat panel of radome material for a frequency range of 84 to 94 GHz, for varying incidence angles. The panel, which was manufactured by Norton Performance Plastics Corporation, was provided to the EPML by TRW. The size of the panel is 40 in x 36 in x 0.422 in and consists of a foam material with one side coated with a smooth white coating (this side will be referred to as the front side). The dielectric properties of the foam material from the inside of the panel were also determined at X-band (8.2-12.4 GHz). The W-band free space measurements are presented first, followed by the X-band dielectric properties measurements.
Transmission spectra of three ferric oxides (two alpha-Fe2O3 samples and one gamma-Fe2O3 sample) and two ferric oxyhydroxides (alpha-FeOOH and gamma-FeOOH) were measured. This preliminary study has demonstrated that crystalline ferric oxides and ferric oxyhydroxides exhibit complex spectral features at thermal wavelengths. Some of these features suggest that thermal infrared observations of Mars can provide significant insight into the ferric mineralogy of that planet. The results of this study suggest that emissivity spectra of crystalline ferric oxides and ferric oxyhydroxides may prove quite important for the interpretation of thermal infrared spectral observations of Mars.