Application of SAMMY for Non-Destructive Characterization of Irradiated Samples Using Neutron Transmission Measurements at VENUS

This report presents the application of SAMMY (Larson 2008), an R-matrix Bayesian fitting system, for analyzing neutron transmission data to enable non-destructive isotopic identification. Transmission measurements were conducted at the VENUS (Bilheux et al. 2023) beamline of the Spallation Neutron Source (SNS) using samples with unknown or partially characterized compositions. Through the application of SAMMY’s R-matrix Bayesian fitting capabilities to the measured transmission spectra and comparison against evaluated nuclear data libraries, isotopic constituents can be quantitatively determined based on their characteristic neutron resonance signatures. This methodology demonstrates significant potential for applications in nuclear safeguards, forensics, and post-irradiation examination.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of Transmission Measurements Capability at VISION Spectrometer [Slides]

This presentation covers the development of transmission measurements capability at VISION Spectrometer. Main takeaways include that INS and transmission measurements are and should be the most significant part of TSL validation, as they are the fundamental quantities used by Monte Carlo neutronics codes. Additionally, the development of transmission capability at VISION instrument has commenced. Promising first results have been obtained with a big impact by the use of the collimators. Finally, Areas of improvement have been identified and new measurements are planned for June.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advancements in Validation of TSLs through Inelastic Neutron Scattering and Transmission Measurements [Slides]

This presentation finds that INS measurements are not as variable based on sample composition, because phonon spectra is a properly of the bulk material. Additionally, INS and transmission measurements are and should be the most significant part of TSL validation, as they are the fundamental quantities used by Monte Carlo neutronics codes. Relaying solely on theoretical atomistic calculations for TSL evaluation is not enough, they are highly dependent on inter-atomic potentials (which are not the most accurate depending on the quantity trying to be reproduced) and evaluators knowledge and understanding of the material being studied. When dealing with Crit. benchmarks - While extremely useful for validation of nuclear data at all energies, critical benchmarks are not the best tool to provide a definitive answer on conflicting TSLs. Finally, INS and transmission measurements need to be the basis of validation of TSLs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Advancements in Validation of TSLs through Inelastic Neutron Scattering and Transmission Measurements [Abstract]

Historically, the free gas approximation has been used to treat the thermal scattering of neutrons with energies below a few electron-volts (eV) in unevaluated materials. However, this method inadequately reproduces neutron scattering at these energies. Until recently, only a limited number of materials had available thermal scattering law (TSL) files/libraries in the ENDF nuclear data libraries in this energy range. With advancements in atomistic modeling techniques, such as molecular dynamics, ab-initio molecular dynamics, and density functional theory, TSL libraries have become available for many more materials. This is particularly relevant due to the rising interest in several advanced reactor systems that require novel moderator and reflector materials. While quasi-integral and integral benchmarks have been designed to validate historically important moderator materials (such as light water and polyethylene), there is currently a lack of standard validation methods for TSLs, especially when multiple conflicting TSLs exist. To address this issue, the Oak Ridge National Lab Nuclear Data group has been working on utilizing inelastic neutron scattering (INS) measurements combined with transmission (i.e., total cross section) measurements to evaluate and validate TSLs for different materials. We plan to demonstrate how this method has worked on materials such as polyethylene, lucite, and polystyrene. In addition, we will compare the newly created libraries to ENDF libraries for these materials and explain why integral benchmarks should not be used for validation when multiple TSLs exist.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron Capture and Transmission Measurements of 54 Fe at the RPI LINAC

54 Fe radiative capture cross section and transmission measurements were conducted at the Rensselaer Polytechnic Institute (RPI) Gaerttner Linear Accelerator (LINAC) Center using an enriched 54 Fe sample in the keV energy region. 54 Fe is a constituent of natural iron, which is present in a large variety of nuclear grade materials. Therefore, it is important to have an accurate understanding of the cross sections of 54 Fe, which can be measured experimentally. In the time-of-flight measurements conducted at the LINAC, an array of four C 6 D 6 detectors surrounded the sample and radiative capture data were collected using a digital data acquisition system. Additionally, a Li-glass detector was used to collect transmission data using an analog data acquisition system. The radiative capture yield of the 54 Fe measurements were normalized to saturated resonances observed in Au and Ta to obtain an absolute capture yield. The preliminary capture yield and preliminary transmission obtained can be compared to evaluations and existing experimental data. Some disagreements were observed in prominent d-wave capture resonances observed in 54 Fe in the low-keV neutron energy region. Both sets of experimental data along with pre-existing datasets will greatly enhance RPI’s ability to perform resonance evaluation for 54 Fe up to roughly 1 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Large Area Picosecond Photodetector for Neutron Transmission Measurements at DICER at LANSCE

The Device for Indirect Capture Experiments on Radionuclides (DICER) is a new instrument that is being developed at the Los Alamos Neutron Science Center (LANSCE) to study neutron capture reactions on short-lived radionuclides. To achieve that, DICER is using an indirect technique based on measuring the neutron transmission through very small samples (0.12–1.2 mm in diameter, $\mu \text{g}$ -mg in mass). The main detection system of DICER consists of two dual photomultiplier (PMT)-based detectors which are sensitive to the scintillation light produced when neutrons interact with 6 Li glass disks. DICER is developing a new collimation system that includes a 0.1-mm collimator. In such small sizes, the need for neutron beam imaging is crucial and necessary to confirm the appropriate alignment between the irradiated sample and the neutron detectors. The large area picosecond photodetector (LAPPD) is a multichannel plate (MCP)-based photodetector, with picosecond-level timing, single-photon detection capabilities, and spatial resolution of the order of 1 mm. Coupling the LAPPD with a 6 Li glass scintillator results in a neutron imaging detector. The first irradiation of the LAPPD at DICER indicated that apart from imaging the beam, the LAPPD can be used as the main neutron detection system. Furthermore, these results were proof of principle measurements demonstrating the capabilities of the beamline, and the challenge with small samples will be addressed in the future. The first efforts and developments, including irradiations of the LAPPD and the first beam images, will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Capture and Transmission Measurements and Evaluation of 54 Fe at the RPI LINAC [Slides]

This presentation covers neutron capture and transmission measurements and evaluation of 54 Fe (Iron) at the Rensselaer Polytechnic Insitute (RPI) Linear Accelerator (LINAC). Presentation conclusions find that 54 Fe is near its conclusion, covariance matrix generation is needed for both experiments before data is made available and released (Completion by April 2023). RPI will be conducting a full Resolved Resonance Region (RRR) evaluation following release of data (Completion by September 2023). Additionally, the neutron beam imager shows promise in providing an easy way to align samples in the most intense part of the neutron beam and there will be a new evaluation that will offer improvements in crit safety, shielding, and stellar applications.

07 ISOTOPE AND RADIATION SOURCES↗

Gallium-doped zinc oxide: nonlinear reflection and transmission measurements and modeling in the ENZ region

Abstract Strong nonlinear materials have been sought after for decades for applications in telecommunications, sensing, and quantum optics. Gallium-doped zinc oxide is a II–VI transparent conducting oxide that shows promising nonlinearities similar to indium tin oxide and aluminum-doped zinc oxide for the telecommunications band. Here we explore its nonlinearities in the epsilon near zero (ENZ) region and show n 2,eff values on the order of 4.5 × 10 −3 cm 2 GW −1 for IR pumping on 200–300 nm thin films. Measuring nonlinear changes in transmission and reflection with a white light source probe in the near-IR while exciting in the near-IR provides data in both time and wavelength. Three films varying in thickness, optical loss, and ENZ crossover wavelength are numerically modeled and compared to experimental data showing agreement for both dispersion and temporal relaxation. In addition, we discuss optimal excitation and probing wavelengths occur around ENZ for thick films but are red-shifted for thin films where our model provides an additional degree of freedom to explore. Obtaining accurate nonlinear measurements is a difficult and time-consuming task where our method in this paper provides experimental and modeled data to the community for an ENZ material of interest.

Ball, Adam (ORCID:0000000318167813)↗

Production of zirconium-88 via proton irradiation of metallic yttrium and preparation of target for neutron transmission measurements at DICER

Abstract A process for the production of tens to hundreds of GBq amounts of zirconium-88 ( 88 Zr) using proton beams on yttrium was developed. For this purpose, yttrium metal targets (≈20 g) were irradiated in a ~16 to 34 MeV proton beam at a beam current of 100–200 µA at the Los Alamos Isotope Production Facility (IPF). The 88 Zr radionuclide was produced and separated from the yttrium targets using hydroxamate resin with an elution yield of 94(5)% (1σ). Liquid DCl solution in D 2 O was selected as a suitable 88 Zr sample matrix due to the high neutron transmission of deuterium compared to hydrogen and an even distribution of 88 Zr in the sample matrix. The separated 88 Zr was dissolved in DCl and 8 µL of the obtained solution was transferred to a tungsten sample can with a 1.2 mm diameter hole using a syringe and automated filling station inside a hot cell. Neutron transmission of the obtained 88 Zr sample was measured at the Device for Indirect Capture Experiments on Radionuclides (DICER).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Corroborating VNA and thermal measurements of transmission loss on the DIII-D ECH waveguide system

Electron cyclotron heating (ECH) and current drive (ECCD) will play a large role in tokamak-based fusion reactors. At the DIII-D tokamak, 110 GHz microwaves injected into the plasma can provide core heating and current drive as well as impurity control, neoclassical tearing mode mitigation, and breakdown assistance. Understanding the physics of these processes relies on accurate estimates of injected ECH power. DIII-D’s ECH system consists of six MW-class Microwave Power Products (MPP) gyrotron microwave sources. Operating the gyrotrons far from the tokamak removes them from magnetic field interference, so 31.75 mm inner-diameter corrugated waveguides transmit the microwave power the 80 m from the gyrotrons to steerable launchers in the tokamak chamber. Estimates of injected power rely on knowing the generated power at the source and then subtracting transmission loss. Conventional transmission loss measurements based on calorimetric dummy loads are onerous and only possible during extended maintenance periods. This work examines two tools that provide more flexibility for the transmission loss measurements. Furthermore, a resistive temperature detector (RTD) array installed along a waveguide measures heat lost to the transmission line, and low power time domain reflectometry (TDR) measurements with a vector network analyzer (VNA) allows loss measurements without burdensome hardware modifications.

ECH↗

Grain Boundary Plane Measurement Using Transmission Electron Microscopy Automated Crystallographic Orientation Mapping for Atom Probe Tomography Specimens

Abstract Grain boundaries are critical in determining the properties of materials, including mechanical stability, conductivity, and corrosion resistance. The specific properties of materials depend not only on the misorientation of the crystals, the three most commonly characterized parameters, but also on the angle of the grain boundary plane between the two crystals, the final two parameters in the five-parameter macroscopic description of the grain boundary. The method presented here allows for the direct measurement of all five parameters of the grain boundary in a transmission electron microscopy specimen of various morphologies. This is especially applicable to atom probe specimens, where only a single-tilt axis is generally available, allowing the crystallographic description to be matched to the detailed chemical data available in the atom probe tomography. This method provides a platform for efficient grain boundary analysis in unique samples, saving operator time and allowing for ease of acquisition and interpretation in comparison with traditional electron diffraction methods.

Materials Science↗

Plasma-free hydrogenation of oxygen-terminated polycrystalline diamond as determined by circular transmission line measurements (CTLM)

Here, we developed a process to fully hydrogen-terminate diamond by annealing in forming gas. The surface was characterized using circular transmission line measurements (CTLMs) to evaluate the onset and degree of hydrogen termination. No hydrogenation occurred at temperatures at or below 500 °C. Hydrogenation occurs after annealing for 5 min at temperatures between 600 and 1000 °C, with complete hydrogenation achieved at 1000 °C, which showed the same sheet resistance as diamond terminated in a hydrogen plasma. Annealing at temperatures lower than 1000 °C resulted in only partial hydrogenation but can be compensated by increasing the anneal time. At temperatures exceeding 1100 °C, the sheet resistance suddenly and drastically increases, indicating instability of a hydrogen-terminated diamond surface at elevated temperatures under forming gas. The activation energy was determined to be 1.20eV. SEM inspection showed that annealing in hydrogen produced significantly reduced surface roughness compared to diamond surfaces hydrogenated in a H 2 plasma.

36 MATERIALS SCIENCE↗

Calcined Polyethyleneimine Coated Optical Fibers for Distributed pH Monitoring at High Pressures and Temperatures

In the oil and gas, CO2 sequestration, H2 subsurface storage, and geothermal energy sectors, subsurface pH measurements are critical for monitoring the geochemical conditions and estimating potential corrosion rates of wellbore systems. Real-time pH measurements in these conditions are vital for detecting and predicting corrosion deterioration of wellbore components that may jeopardize the safety and continued operation of wellbore systems. Building off of earlier TiO2 based pH sensors and the known pH sensitivity of amine-based polymers, a coating based on the secondary amine polymer polyethyleneimine (PEI) was developed. The sensor coating was treated with a high temperature (500 °C) calcination procedure in air to convert it into a more stable oxidized coating capable of withstanding hot aqueous solutions without dissolving while retaining linear pH sensitivity from pH values between 2 and 11. The sensor performance was measured using optical transmission measurements in solutions of various pHs and using optical backscatter reflectometry for distributed pH sensing demonstration in wellbore-relevant pressures (up to 1000 psi) and temperatures (80 °C). A calibration curve with strong differentiation between acidic and alkaline pH was developed for both transmission-based and distributed pH measurements, using fixed wavelength transmission and integrated linear amplitude of backscattered light for distributed measurements.

Shumski, Alexander↗

ORNL’s Continuing Efforts in Evaluating and Validating TSLs [Slides]

This presentation finds that INS measurements are not as variable based on sample composition, because phonon spectra is a properly of the bulk material. Additionally, INS and transmission measurements are and should be the most significant part of TSL validation, as they are the fundamental quantities used by Monte Carlo neutronics codes. This presentation reasons that relaying solely on theoretical atomistic calculations for TSL evaluation is not enough, they are highly dependent on inter-atomic potentials (which are not the most accurate depending on the quantity trying to be reproduced) and evaluators knowledge and understanding of the material being studied. Finally on Critical benchmarks, while extremely useful for validation of nuclear data at all energies, critical benchmarks are not the best tool to provide a definitive answer on conflicting TSLs. The presentation concludes that INS and transmission measurements need to be the basis of validation of TSLs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Status of ORNL TSL evaluations [Slides]

This lecture provides details on the status of ORNL TSL evaluations. Main sections include modeling of concrete, updates of polyethylene evaluation, and initial transmission measurements at Oak Ridge National Labatory (ORNL). The presentation Conclusions show that literature review and initial modeling of concrete components have been performed. INS and transmission measurements of concrete and hydrated cement have been also planned. Additionally, A new TSL library for Polyethylene was created and submitted to NNDC and development for a new transmission capability at ORNL is underway.

36 MATERIALS SCIENCE↗

Slitless spectrophotometry with forward modelling: Principles and application to measuring atmospheric transmission

Context.In the next decade, many optical surveys will aim to answer the question of the nature of dark energy by measuring its equation-of-state parameter at the per mill level. This requires trusting the photometric calibration of the survey with a precision never reached so far on many sources of systematic uncertainties. The measurement of the on-site atmospheric transmission for each exposure, or for each season or for the full survey on average, can help reach the per mill precision for the magnitudes. Aims.This work aims at proving the ability to use slitless spectroscopy for standard-star spectrophotometry and its use to monitor on-site atmospheric transmission as needed, for example, by theVera C. RubinObservatory Legacy Survey of Space and Time supernova cosmology program. We fully deal with the case of a disperser in the filter wheel, which is the configuration chosen in theRubinAuxiliary Telescope. Methods.The theoretical basis of slitless spectrophotometry is at the heart of our forward-model approach to extract spectroscopic information from slitless data. We developed a publicly available software calledSpectractor, which implements each ingredient of the model and finally performs a fit of a spectrogram model directly on image data to obtain the spectrum. Results.We show through simulations that our model allows us to understand the structure of spectrophotometric exposures. We also demonstrate its use on real data by solving specific issues and illustrating that our procedure allows the improvement of the model describing the data. Finally, we discuss how this approach can be used to directly extract atmospheric transmission parameters from the data and thus provide the base for on-site atmosphere monitoring. We show the efficiency of the procedure in simulations and test it on the limited available data set.

Astronomy & Astrophysics↗