Search NASA⌕ Search

SEARCH · Search NASA

Results for “Triple oxygen isotope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

A Method for Rapid and Precise Triple Oxygen Isotope Measurements via High-Temperature Conversion to CO Followed by Nickel-Catalyzed CO to CO 2 Conversion and Laser Spectroscopy

Triple oxygen isotopic compositions ( 16 O, 17 O, 18 O) have conventionally been measured via isotope ratio mass spectrometry using O 2 as an analyte. Conversion of sample oxygen to O 2 typically utilizes fluorination chemistry or catalytic equilibration between CO 2 and O 2 . Recently, laser spectroscopy has become a viable alternative for triple oxygen isotope (Δ' 17 O) measurements due to its ease and rapid throughput. Laser spectrometers are currently available for Δ' 17 O analysis of either H 2 O or CO 2 as the analyte gas. So far, these instruments have been used to measure Δ' 17 O of water, carbonate (CO 2 liberated by acid digestion), and atmospheric CO 2 samples. Here, we present a new method for high-precision Δ' 17 O analysis of CO 2 via tunable infrared laser direct absorption spectroscopy that is compatible with a wider range of geochemically important materials. This approach involves converting sample oxygen to CO 2 in two steps. First, the sample oxygen is liberated and reduced to CO by high-temperature conversion at 1450 °C in the presence of excess elemental carbon. Then, CO is catalytically converted to CO 2 over hot nickel at 350 °C. The conversion process is rapid (10 to 30 min) and quantitative. Spectroscopic Δ' 17 O analysis of the resulting CO 2 takes approximately 45 min. By measuring several oxygen isotope standards, we demonstrate that the method is precise (1σ = 12 per meg for procedural replicates) and accurate (within 11 per meg of previously reported values). The method can be applied to most pyrolytic materials where quantitative oxygen conversion is attainable, such as sulfate, phosphate, nitrate, and oxide minerals, water, and organic molecules.

Ellis, Nicholas M. [University of California, Berk↗

Triple oxygen isotope compositions of globally distributed soil carbonates record widespread evaporation of soil waters

The stable isotopic composition of pedogenic carbonates is central to many studies of past climate and topography, providing a basis for our understanding of Earth's terrestrial history. A core assumption of many applications of oxygen isotope values (δ 18 O) of pedogenic carbonate is that they reflect the δ 18 O value of precipitation (rain/snow). Here, this assumption is violated if soil carbonates form in evaporated soil waters. In this work, we develop a means to identify evaporation in ancient soils using the triple oxygen isotope composition ( 16 O- 17 O- 18 O) of pedogenic carbonates.

58 GEOSCIENCES↗

Triple oxygen and hydrogen stable isotope composition of water in Murchison carbonaceous chondrite accessed by thermogravimetry-enabled laser spectroscopy

For this work, we have developed the capability to measure 17 O/ 16 O in H 2 O and OH - of hydrous minerals by a technique using thermogravimetric analysis coupled with isotope ratio infrared spectroscopy (TGA-IRIS) on a suite of liquid water standards, terrestrial mineral standards, multi-mineral synthetic mixtures of terrestrial samples, and Murchison carbonaceous chondrite. This 17 O/ 16 O analytical capability is combined with the previously developed TGA-IRIS capability of 18 O/ 16 O, which enables us to calculate Δ `17 O values. Additionally, we have made 2 H/ 1 H measurements by TGA-IRIS on the suite of materials. Analyses of 328 standard water samples sealed into silver tubes (0.25 μL, 174 VSMOW and 154 GISP) analyzed over the course of three years yielded δ 18 O values by TGA-IRIS with precision of ±0.30 ‰, δ 17 O of ±0.24 ‰, Δ `17 O of ±0.126 ‰, and δ 2 H ± 7.5 ‰ (± 1 Std. Dev.). TGA-IRIS analyses of a suite of hydrous minerals (oxy-hydroxide, mica, serpentines, sulfide, phyllosillicates) yields similar precision. TGA-IRIS analyses of the CM2 carbonaceous chondrite Murchison resulted in δ 18 O, δ 17 O, Δ `17 O, and δ 2 H values of the H 2 O and/or OH - from its hydrous minerals. Δ `17 O values of Murchison H 2 O range from 1.034 ‰ at 350 °C, to -0.368 ‰ at 650 °C, to -1.75 ‰ at 850 °C. TGA-IRIS can generate Δ `17 O values of H 2 O and/or OH - in hydrous materials that are well within the precision needed for the analysis of meteoritic samples, as well as samples returned from asteroids, such as Ryugu and Bennu.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Triple oxygen and hydrogen stable isotope composition of hydroxyl water in Orgueil (CI-type) and Tagish Lake (C2-type) carbonaceous chondrites

The primitive carbonaceous chondrites are of interest to cosmochemical science because they contain relatively large amounts of ‘water’ (H 2 O and/or OH – ) within phyllosilicate minerals. This water is evidence for the accretion of ices by their parent planetesimals, and thus represents an archive of the isotopic compositions of H 2 O in the protoplanetary environments. Here, in this study, we used thermogravimetry-enabled laser spectroscopy (TGA-IRIS) analyses of the Orgueil and Tagish Lake meteorites to make δ 2 H, δ 18 O, and Δ′ 17 O measurements of the H 2 O and OH – contained in the different hydrous minerals that comprise each meteorite. In Orgueil, we measured mass-weighted averages of OH – in the saponite and serpentine phyllosilicate matrix to be δ 2 H = 192 ‰, δ 18 O = 1.5 ‰, which are unquestionably of extraterrestrial origin with Δ′ 17 O = 1.0 ‰. For Tagish Lake, analogous values of OH– in the saponite and serpentine phyllosilicate matrix are δ 2 H = 704 ‰, δ 18 O = 11.3 ‰, and are similarly unambiguously extraterrestrial with Δ′ 17 O = 0.82 ‰. We estimate that the parent H 2 O involved in aqueous alteration of Orgueil had δ 18 O value ≥ +23 ‰. In Orgueil, we interpret the phyllosilicate petrographic relationships, and the δ 18 O values of OH – in saponite and serpentine to indicate that saponite formed first, at a lower temperature by 35 to 53 °C than serpentine. This suggests that the Orgueil parent body experienced increasing temperature during the phase of active aqueous alteration (prograde) which set the δ 18 O OH values of the serpentine and saponite. In the case of Tagish Lake, serpentine formed at a lower temperature by 32 to 60 °C than saponite, for the simplest case with constant δ 18 O H2O values. If serpentine formed first, followed by saponite formation at 32 to 60 °C °C higher temperature, this suggests that Tagish Lake sample TL1 underwent prograde aqueous alteration as the parent body heated up. We find evidence that the parent H 2 O for Orgueil, Tagish Lake sample TL1, and Murchison (based on data from a previous study) may have had Δ′ 17 O values of >0.64 ‰.

Aqueous alteration↗

Low-energy cross-section measurement of the B 10 ( α , n ) N 13 reaction and its impact on neutron production in first-generation stars

Nucleosynthesis in the first generation of massive stars offers a unique setting to explore the creation of the first heavier nuclei in an environment free of impurities from earlier stellar generations. In later generations of massive stars, hydrogen burning occurs predominantly through the CNO cycles, but without the carbon, nitrogen, and oxygen to catalyze the reaction sequence, first stars would have to rely on the inefficient pp chains for their energy production. Observations of second and third generation stars show pronounced abundances of carbon and oxygen isotopes, which suggests a rapid conversion of the primordial abundances to heavier elements. While the triple-alpha-process primarily facilitates this conversion, there are alternative reaction sequences, such as 2 H(α,γ) 6 Li(α,γ) 10 B(α,n) 13 N, that may play a significant role. To study such alternate reaction pathways for production of carbon and heavier nuclei, a number of new measurements are needed. In this work, new measurements are reported for the 10 B(α,n) 13 N reaction, extending the cross section down to 575 keV incident α-particle energy. The measurements were made using a state-of-the-art deuterated liquid scintillator and a spectrum unfolding technique. An R-matrix analysis was performed in order to facilitate a comparison of the underlying nuclear structure with the reaction measurements. An unexpected upturn is observed in the low-energy S factor that indicates the presence of a new low-energy resonance. Finally, a revised reaction rate is determined that takes into account the present data as well as other previous measurements from the literature that were previously neglected.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An Unbalanced Battle in Excellence: Revealing Effect of Ni/Co Occupancy on Water Splitting and Oxygen Reduction Reactions in Triple–Conducting Oxides for Protonic Ceramic Electrochemical Cells

Porous electrodes that conduct electrons, protons, and oxygen ions with dramatically expanded catalytic active sites can replace conventional electrodes with sluggish kinetics in protonic ceramic electrochemical cells. In this work, a strategy is utilized to promote triple conduction by facilitating proton conduction in praseodymium cobaltite perovskite through engineering non-equivalent B-site Ni/Co occupancy. Surface infrared spectroscopy is used to study the dehydration behavior, which proves the existence of protons in the perovskite lattice. The proton mobility and proton stability are investigated by hydrogen/deuterium (H/D) isotope exchange and temperature-programmed desorption. It is observed that the increased nickel replacement on the B-site has a positive impact on proton defect stability, catalytic activity, and electrochemical performance. This doping strategy is demonstrated to be a promising pathway to increase catalytic activity toward the oxygen reduction and water splitting reactions. The chosen PrNi 0.7 Co 0.3 O 3–δ oxygen electrode demonstrates excellent full-cell performance with high electrolysis current density of –1.48 A cm –2 at 1.3 V and a peak fuel-cell power density of 0.95 W cm –2 at 600 °C and also enables lower-temperature operations down to 350 °C, and superior long-term durability.

08 HYDROGEN↗

Preliminary Testing of a Continuous Cryopump for Primary Fusion Device Pumping and Direct Internal Recycling

Here, the concept of directly recirculating fusion machine exhaust gas, bypassing the tritium plant, to make fuel pellets was proposed in the 1990s and later termed direct internal recycling (DIR). In the DIR concept, the residual fusion fuel in the machine exhaust stream is separated from impurities locally and diverted directly to the fueling systems, bypassing isotopic separation and other processing equipment, and therefore significantly reducing the required size of the fuel processing plant, reducing plant inventory, and thus increasing the economic viability of fusion as an energy source. One concept for DIR consists of a series of cryogenic pumps to separate the impurities from the machine exhaust gas using different triple point temperatures and saturation curves of exhaust constituents. In this concept, the plasma exhaust is initially passed through an impurity trap operating at ~25–30 K to desublimate impurities such as hydrocarbons, argon, oxygen, and nitrogen. The resulting process stream will consist of DT fuel and helium. The process stream is then pumped by a continuous cryopump known as a “snail pump.” This pump is a steady-state continuous cryopump that desublimates all remaining exhaust gas constituents while allowing helium, a byproduct of the fusion reaction, to pass through. The helium is pumped to the tritium plant for processing while the desublimated material is continuously scraped off, heated up, and transported to the fueling system. This article will present the cryogenic DIR concept and outline the design and operation of the snail pump, along with results from preliminary testing. Tests to assess pumping and separation efficiency found that at D2 flows below 50.7 Pa ⋅ m3/s with 1% helium, the pump is capable of pumping and separating the gas with a resulting DIR fraction of >99%, with no helium entrained in the primary fuel exhaust stream. The main limitation is due to the thermal performance of the cryogenic circuits of the pump, which will be addressed in future testing.

Gebhart III, Trey E. [Oak Ridge National Laborator↗

Thermodynamics, local structure, and transport of protons in triple-conducing oxide, BaCo 0.4 Fe 0.4 Zr 0.1 Y 0.1 O 3-δ (BCFZY4411)

Triple-conducting oxides (TCOs) are an emerging class of mixed ionic and electronically conducting materials that show great promise for oxygen reduction/oxygen evolution (ORR/OER) electrocatalysis—primarily in high-temperature ceramic electrochemical cells— but also in aqueous alkaline environments. Their high activity is attributed, at least in part, to their ability to incorporate and transport three mobile charge carriers: protons, oxygen vacancies, and electron-holes Despite their promise, fundamental studies of TCOs are challenging, as transport dynamics from three charge carriers cannot be fully disentangled via traditional electrical measurement techniques. Characterizing proton dynamics in TCOs is particularly difficult as protons are generally the minority carrier, and their conduction response is typically obscured by the oxygen vacancies and electron holes. Here, we demonstrate successful isolation of the proton behavior in an archetypal TCO, BaCo 0.4 Fe 0.4 Zr 0.1 Y 0.1 O 3-δ (BCFZY4411), using a combination of non-electrical techniques. We determine proton uptake and oxygen non-stoichiometry (δ) using thermogravimetric analysis (TGA). X-ray absorption near edge structure (XANES) and neutron diffraction (ND) are used to validate the oxidation state of Co and the δ values obtained through TGA. We apply 1H solid-state magic-angle-spinning (MAS) nuclear magnetic resonance (NMR) to provide insights into local structure, dynamics, and proton kinetics. Finally, the proton transport properties are further quantified using tracer isotope exchange with time-of-flight secondary ion mass spectrometry (ToF-SIMS). Despite the very low proton concentrations in BCFZY4411 (<0.2% under most conditions), our analysis suggests that the oxygen Manuscript File Click here to view linked References 2 reduction and evolution reactions are nevertheless limited by the oxygen ion kinetics (e.g., oxygen surface exchange) rather than the proton kinetics at the reduced operating temperatures (<500 °C) that are targeted for electrochemical cell applications. These findings provide a comprehensive understanding of proton behavior in BCFZY4411 and pave the way for advancing the fundamental study of TCOs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Organic contamination detection for isotopic analysis of water by laser spectroscopy

Hydrogen and oxygen stable isotope ratios (δ 2 H, δ 17 O, and δ 18 O values) are commonly used tracers of water. These ratios can be measured by isotope ratio infrared spectroscopy (IRIS). However, IRIS approaches are prone to errors induced by organic compounds present in plant, soil, and natural water samples. A novel approach using 17 O-excess values has shown promise for flagging spectrally contaminated plant samples during IRIS analysis. A systematic assessment of this flagging system is needed to prove it useful. Errors induced by methanol and ethanol water mixtures on measured IRIS and isotope ratio mass spectrometry (IRMS) results were evaluated. For IRIS analyses both liquid- and vapour-mode (via direct vapour equilibration) methods are used. The δ 2 H, δ 17 O, and δ 18 O values were measured and compared with known reference values to determine the errors induced by methanol and ethanol contamination. In addition, the 17 O-excess contamination detection approach was tested. This is a post-processing detection tool for both liquid and vapour IRIS triple-isotope analyses, utilizing calculated 17 O-excess values to flag contaminated samples. Organic contamination induced significant errors in IRIS results, not seen in IRMS results. Methanol caused larger errors than ethanol. Results from vapour-IRIS analyses had larger errors than those from liquid-IRIS analyses. The 17 O-excess approach identified methanol driven error in liquid- and vapour-mode IRIS samples at levels where isotope results became unacceptably erroneous. For ethanol contaminated samples, a mix of erroneous and correct flagging occurred with the 17 O-excess method. Here our results indicate that methanol is the more problematic contaminant for data corruption. The 17 O-excess method was therefore useful for data quality control. Organic contamination caused significant errors in IRIS stable isotope results. These errors were larger during vapour analyses than during liquid IRIS analyses, and larger for methanol than ethanol contamination. The 17 O-excess method is highly sensitive for detecting narrowband (methanol) contamination error in vapour and liquid analysis modes in IRIS.

60 APPLIED LIFE SCIENCES↗