Search NASA⌕ Search

SEARCH · Search NASA

Results for “Troubleshooting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The Challenges of Troubleshooting

Troubleshooting work presents electrical and other workers with a challenging combination of physical hazards, working conditions, and time pressure, which can lead to unwanted outcomes if not carefully managed.Summaries of several incidents in which workers were injured or at risk of injury while performing troubleshooting work are presented, identifying organizational weaknesses and error precursors that contributed to each incident.The primary challenges include:Deranged equipment. Equipment that needs troubleshooting is not in a normal operating condition. Actions that are safe when the equipment is in a normal state may not be safe in the deranged state.Work planning and control. The steps taken in troubleshooting are most often determined by the results of the immediately previous diagnostic test, making effective work planning challenging.Multiple types of hazards. Most equipment will present a troubleshooting worker with several types of hazards, including hazardous energy as defined in 29 CFR 1910.147. Portions of the troubleshooting activity may be infeasible without these hazards present.Time pressure. Restoring operation of failed equipment often involves an explicit or implicit sense of urgency.Equipment design and construction. The physical construction of the equipment in large part will determine to which hazards troubleshooters may be exposed. It will also determine which hazards may be encountered while performing the servicing needed to restore the equipment or system to operation.There are effective methods for addressing each challenge, most of which require a combination of advance preparation and management commitment.

Mertz, David E.↗

The Challenges of Safe Troubleshooting Work

Troubleshooting work presents electrical and other workers with a challenging combination of physical hazards, working conditions, and time pressure, which can lead to unwanted outcomes if not carefully managed. Summaries of several incidents in which workers were injured or at risk of injury while performing troubleshooting work are presented, identifying organizational weaknesses and error precursors that contributed to each incident. The primary challenges include: Deranged equipment. Equipment that needs troubleshooting is not in a normal operating condition. Actions that are safe when the equipment is in a normal state may not be safe in the deranged state. Work planning and control. The steps taken in troubleshooting are most often determined by the results of the immediately previous diagnostic test, making effective work planning challenging. Multiple types of hazards. Most equipment will present a troubleshooting worker with several types of hazards, including hazardous energy as defined in 29 CFR 1910.147. Portions of the troubleshooting activity may be infeasible without these hazards present. Time pressure. Restoring operation of failed equipment often involves an explicit or implicit sense of urgency. There are effective methods for addressing each challenge, most of which require a combination of advance preparation and management commitment.

Mertz, David E.↗

Connectivity Troubleshooting Guide for Advanced Electricity Meters

This guide is designed to walk users through a troubleshooting process for disconnected advanced electricity meters. The guide centers on two connectivity troubleshooting decision trees related to power issues and network connectivity issues, respectively. Additionally, it contains additional background information such as definitions, diagrams, and checklists that can help a user prepare to troubleshoot meter connectivity issues.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Troubleshoot Quartz Crystal Microbalance Measurements Data

We are using a Qpod quartz crystal microbalance (manufactured by Inficon) for use as a low-volume non-volatile residue analysis tool. Inficon has agreed to help troubleshoot some of our measurements and are requesting to view some sample data, which are attached. The basic principle of an NVR analysis is to evaporate a known volume of solvent, and weigh the remaining residue to determine the purity of the solvent. A typical NVR analysis uses 60 g of solvent and can measure residue with an accuracy of +/- 0.01 mg. The detection limit is thus (0.01 mg)/(60 g) = 0.17 ppm. We are attempting to use a quartz crystal microbalance (QCM) to make a similar measurement. The attached data show the response of the QCM as a 5-20 mg drop of solvent evaporates on its surface. The change in mass registered by the QCM after the drop evaporates is the residue that deposits on the crystal. On some measurements, the change in mass in less than zero, which is aphysical since the drop will leave behind ≥0 mass of residue. The vendor, Inficon, has agreed to look at these data as a means to help troubleshoot the cause.

42 ENGINEERING↗

Electrical Shock During Phone Assisted Troubleshooting of Laboratory Equipment

We report researchers have the potential to be exposed to a wide variety of hazards inherent to the equipment they use and maintain. When equipment does not function as expected, researchers sometimes reach out to their vendors for assistance. Early diagnostic or troubleshooting interactions between researcher and vendor are often conducted over the telephone and can lead to researchers performing work outside of their area of expertise and exposure to unknown hazards. This type of interaction significantly contributed to an incident where during diagnostic activities a researcher accidentally contacted, and discharged, a capacitor in an X-ray diffraction instrument. While this incident did not produce a serious injury, if the capacitor discharge path had occurred hand-to-hand across the heart, a serious injury may have been possible.

47 OTHER INSTRUMENTATION↗

Troubleshooting time-dependent density-functional theory for photochemical applications: Oxirane

The development of analytic-gradient methodology for excited states within conventional time-dependent density-functional theory (TDDFT) would seem to offer a relatively inexpensive alternative to better established quantum-chemical approaches for the modeling of photochemical reactions. However, even though TDDFT is formally exact, practical calculations involve the use of approximate functional, in particular the TDDFT adiabatic approximation, the use of which in photochemical applications must be further validated. Here, we investigate the prototypical case of the symmetric CC ring opening of oxirane. We demonstrate by direct comparison with the results of high-quality quantum Monte Carlo calculations that, far from being an approximation on TDDFT, the Tamm-Dancoff approximation is a practical necessity for avoiding triplet instabilities and singlet near instabilities, thus helping maintain energetically reasonable excited-state potential energy surfaces during bond breaking. Other difficulties one would encounter in modeling oxirane photodynamics are pointed out.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enabling petascale science : data management, troubleshooting and scalable science services.

The Center for Enabling Distributed Petascale Science is developing serviced to enable researchers to manage large, distributed datasets. The center projects focus on three areas: tools for reliable placement of data, issues involving failure detection and failure diagnosis in distributed systems, and scalable services that process requests to access data.

99 GENERAL AND MISCELLANEOUS↗

TH-B-BRC-02: Troubleshooting Issues with Linear Accelerator

Radiation treatment consists of a chain of events influenced by the quality of machine operation, beam data commissioning, machine calibration, patient specific data, simulation, treatment planning, imaging and treatment delivery. There is always a chance that the clinical medical physicist may make or fail to detect an error in one of the events that may impact on the patient’s treatment. In the clinical scenario, errors may be systematic and, without peer review, may have a low detectability because they are not part of routine QA procedures. During treatment, there might be errors on machine that needs attention. External reviews of some of the treatment delivery components by independent reviewers, like IROC, can detect errors, but may not be timely. The goal of this session is to help junior clinical physicists identify potential errors as well as the approach of quality assurance to perform a root cause analysis to find and eliminate an error and to continually monitor for errors. A compilation of potential errors will be presented by examples of the thought process required to spot the error and determine the root cause. Examples may include unusual machine operation, erratic electrometer reading, consistent lower electron output, variation in photon output, body parts inadvertently left in beam, unusual treatment plan, poor normalization, hot spots etc. Awareness of the possibility and detection of error in any link of the treatment process chain will help improve the safe and accurate delivery of radiation to patients. Four experts will discuss how to identify errors in four areas of clinical treatment. D. Followill, NIH grant CA 180803.

60 APPLIED LIFE SCIENCES↗

Troubleshooting deep-learner training data problems using an evolutionary algorithm on Summit

Architectural and hyper-parameter design choices can influence deep-learner (DL) model fidelity but can also be affected by malformed training and validation data. However, practitioners may spend significant time refining layers and hyper-parameters before discovering that distorted training data was impeding training progress. We found that an evolutionary algorithm (EA) can be used to diagnose this kind of DL problem. An EA evaluated thousands of DL configurations on Summit that yielded no overall improvement in DL performance, which suggested problems with the training and validation data. We suspected that Contrast Limited Adaptive Histogram Equalization (CLAHE) enhancement that was applied to previously generated digital surface models (DSMs), for which we were training DLs to find errors, had damaged the training data. Subsequent runs with an alternative global normalization yielded significantly improved DL performance. However, the DL Intersection Over Union (IOU) still exhibited consistent sub-par performance, which suggested further problems with the training data and DL approach. Nonetheless, we were able to diagnose this problem within a 12-hour span via Summit runs, which prevented several weeks of unproductive trial-and-error DL configuration refinement, and allowed for a more timely convergence on an ultimately viable solution.

97 MATHEMATICS AND COMPUTING↗

LANL HDZoom Camera Troubleshooting [Slides]

Photo progression grid flight over white roof– HDZoom, photo progression grid flight over white roof – EO/IR and photo progression circular flight – HDZoom.

42 ENGINEERING↗