At least 19 records

TEP Power Partners Project [Tucson Electric Power]

The Arizona Governor’s Office of Energy Policy, in partnership with Tucson Electric Power (TEP), Tendril, and Next Phase Energy (NPE), formed the TEP Power Partners pilot project to demonstrate how residential customers could access their energy usage data and third party applications using data obtained from an Automatic Meter Reading (AMR) network. The project applied for and was awarded a Smart Grid Data Access grant through the U.S. Department of Energy. The project participants’ goal for Phase I is to actively engage 1,700 residential customers to demonstrate sustained participation, reduction in energy usage (kWh) and cost ($), and measure related aspects of customer satisfaction. This Demonstration report presents a summary of the findings, effectiveness, and customer satisfaction with the 15-month TEP Power Partners pilot project. The objective of the program is to provide residential customers with energy consumption data from AMR metering and empower these participants to better manage their electricity use. The pilot recruitment goals included migrating 700 existing customers from the completed Power Partners Demand Response Load Control Project (DRLC), and enrolling 1,000 new participants. Upon conclusion of the project on November 19, 2013; 1,390 Home Area Networks (HANs) were registered; 797 new participants installed a HAN; Survey respondents’ are satisfied with the program and found value with a variety of specific program components; Survey respondents report feeling greater control over their energy usage and report taking energy savings actions in their homes after participating in the program; On average, 43 % of the participants returned to the web portal monthly and 15% returned weekly; and An impact evaluation was completed by Opinion Dynamics and found average participant savings for the treatment period1 to be 2.3% of their household use during this period.2 In total, the program saved 163 MWh in the treatment period of 2013.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solar Power Ramp Events Detection Using an Optimized Swinging Door Algorithm: Preprint

Solar power ramp events (SPREs) are those that significantly influence the integration of solar power on non-clear days and threaten the reliable and economic operation of power systems. Accurately extracting solar power ramps becomes more important with increasing levels of solar power penetrations in power systems. In this paper, we develop an optimized swinging door algorithm (OpSDA) to detection. First, the swinging door algorithm (SDA) is utilized to segregate measured solar power generation into consecutive segments in a piecewise linear fashion. Then we use a dynamic programming approach to combine adjacent segments into significant ramps when the decision thresholds are met. In addition, the expected SPREs occurring in clear-sky solar power conditions are removed. Measured solar power data from Tucson Electric Power is used to assess the performance of the proposed methodology. OpSDA is compared to two other ramp detection methods: the SDA and the L1-Ramp Detect with Sliding Window (L1-SW) method. The statistical results show the validity and effectiveness of the proposed method. OpSDA can significantly improve the performance of the SDA, and it can perform as well as or better than L1-SW with substantially less computation time.

14 SOLAR ENERGY↗

Utility Solar Generation Valuation Methods

Tucson Electric Power (TEP) developed, tested and verified the results of a new and appropriate method for accurately evaluating the capacity credit of time variant solar generating sources and reviewed new methods to appropriately and fairly evaluate the value of solar generation to electric utilities. The project also reviewed general integrated approaches for adequately compensating owners of solar generation for their benefits to utilities. However, given the limited funding support and time duration of this project combined with the significant differences between utilities regarding rate structures, solar resource availability and coincidence of solar generation with peak load periods, it is well beyond the scope of this project to develop specific rate, rebate, and interconnection approaches to capture utility benefits for all possible utilities. The project developed computer software based evaluation method models to compare solar generation production data measured in very short term time increments called Sample Intervals over a typical utility Dispatch Cycle during an Evaluation Period against utility system load data. Ten second resolution generation production data from the SGSSS and actual one minute resolution TEP system load data for 2006 and 2007, along with data from the Pennington Street Garage 60 kW DC capacity solar unit installed in downtown Tucson will be applied to the model for testing and verification of the evaluation method. Data was provided by other utilities, but critical time periods of data were missing making results derived from that data inaccurate. The algorithms are based on previous analysis and review of specific 2005 and 2006 SGSSS production data. The model was built, tested and verified by in house TEP personnel. For this phase of the project, TEP communicated with, shared solar production data with and collaborated on the development of solar generation valuation tools with other utilities, including Arizona Public Service, Salt River Project, Xcel and Nevada Power Company as well as the Arizona electric cooperatives. In the second phase of the project, three years of 10 second power output data of the SGSSS was used to evaluate the effectiveness of frequency domain analysis, normal statistical distribution analysis and finally maximum/minimum differential output analysis to test the applicability of these mathematic methods in accurately modeling the output variations produced by clouds passing over the SGSSS array.

14 SOLAR ENERGY↗

Western Wind and Solar Integration Study: Hydropower Analysis

The U.S. Department of Energy's (DOE) study of 20% Wind Energy by 2030 was conducted to consider the benefits, challenges, and costs associated with sourcing 20% of U.S. energy consumption from wind power by 2030. This study found that with proactive measures, no insurmountable barriers were identified to meet the 20% goal. Following this study, DOE and the National Renewable Energy Laboratory(NREL) conducted two more studies: the Eastern Wind Integration and Transmission Study (EWITS) covering the eastern portion of the U.S., and the Western Wind and Solar Integration Study (WWSIS) covering the western portion of the United States. The WWSIS was conducted by NREL and research partner General Electric (GE) in order to provide insight into the costs, technical or physical barriers,and operational impacts caused by the variability and uncertainty of wind, photovoltaic, and concentrated solar power when employed to serve up to 35% of the load energy in the WestConnect region (Arizona, Colorado, Nevada, New Mexico, and Wyoming). WestConnect is composed of several utility companies working collaboratively to assess stakeholder and market needs to and develop cost-effectiveimprovements to the western wholesale electricity market. Participants include the Arizona Public Service, El Paso Electric Company, NV Energy, Public Service of New Mexico, Salt River Project, Tri-State Generation and Transmission Cooperative, Tucson Electric Power, Xcel Energy and the Western Area Power Administration.

13 HYDRO ENERGY↗

Evaluation of PV Module Field Performance

This paper describes an effort to inspect and evaluate PV modules in order to determine what failure or degradation modes are occurring in field installations. This paper will report on the results of six site visits, including the Sacramento Municipal Utility District (SMUD) Hedge Array, Tucson Electric Power (TEP) Springerville, Central Florida Utility, Florida Solar Energy Center (FSEC), the TEP Solar Test Yard, and University of Toledo installations. The effort here makes use of a recently developed field inspection data collection protocol, and the results were input into a corresponding database. The results of this work have also been used to develop a draft of the IEC standard for climate and application specific accelerated stress testing beyond module qualification. TEP Solar Test Yard, and University of Toledo installations. The effort here makes use of a recently developed field inspection data collection protocol, and the results were input into a corresponding database. The results of this work have also been used to develop a draft of the IEC standard for climate and application specific accelerated stress testing beyond module qualification. TEP Solar Test Yard, and University of Toledo installations. The effort here makes use of a recently developed field inspection data collection protocol, and the results were input into a corresponding database. The results of this work have also been used to develop a draft of the IEC standard for climate and application specific accelerated stress testing beyond module qualification.

14 SOLAR ENERGY↗

University of Arizona Compressed Air Energy Storage

Boiled down to its essentials, the grant’s purpose was to develop and demonstrate the viability of compressed air energy storage (CAES) for use in renewable energy development. While everyone agrees that energy storage is the key component to enable widespread adoption of renewable energy sources, the development of a viable scalable technology has been missing. The Department of Energy has focused on expanded battery research and improved forecasting, and the utilities have deployed renewable energy resources only to the extent of satisfying Renewable Portfolio Standards. The lack of dispatchability of solar and wind-based electricity generation has drastically increased the cost of operation with these components. It is now clear that energy storage coupled with accurate solar and wind forecasting make up the only combination that can succeed in dispatchable renewable energy resources. Conventional batteries scale linearly in size, so the price becomes a barrier for large systems. Flow batteries scale sub-linearly and promise to be useful if their performance can be shown to provide sufficient support for solar and wind-base electricity generation resources. Compressed air energy storage provides the most desirable answer in terms of scalability and performance in all areas except efficiency. With the support of the DOE, Tucson Electric Power and Science Foundation Arizona, the Arizona Research Institute for Solar Energy (AzRISE) at the University of Arizona has had the opportunity to investigate CAES as a potential energy storage resource.

25 ENERGY STORAGE↗

A reliability and availability sensitivity study of a large photovoltaic system.

A reliability and availability model has been developed for a portion of the 4.6 megawatt (MWdc) photovoltaic system operated by Tucson Electric Power (TEP) at Springerville, Arizona using a commercially available software tool, GoldSim{trademark}. This reliability model has been populated with life distributions and repair distributions derived from data accumulated during five years of operation of this system. This reliability and availability model was incorporated into another model that simulated daily and seasonal solar irradiance and photovoltaic module performance. The resulting combined model allows prediction of kilowatt hour (kWh) energy output of the system based on availability of components of the system, solar irradiance, and module and inverter performance. This model was then used to study the sensitivity of energy output as a function of photovoltaic (PV) module degradation at different rates and the effect of location (solar irradiance). Plots of cumulative energy output versus time for a 30 year period are provided for each of these cases.

14 SOLAR ENERGY↗

Development of an Open-Source Life Cycle Baseline for Electricity Consumption in the United States - LCAXIX

This work was presented at the American Center for Life Cycle Assessment 2019 Conference (LCAXIX) in Tucson, AZ on September 25, 2019. The electricity and power generation sector in the United States (U.S.) is undergoing a period of rapid transformation via the adoption of natural gas-fired power plants, incorporation of renewable feedstocks, and phasing-out of older power-generation systems (e.g. legacy coal and nuclear). However, this historic shift in the supply/demand of electricity and diversification of power generation technologies is accompanied by resource consumption and emissions to land, water, and soil, and thus may have unintended environmental consequences. EPA, NETL, ANL, and NREL collaborated to develop an open source multifunctional life cycle model to quantify baseline life cycle impacts of U.S. electricity consumption. This presentation is intended to walk through the modeling assumptions, structure, and results for the released inventory.

Cooney, Gregory↗

Progress of Nanotechnology for Lithium-Sulfur Batteries

Lithium-Sulfur (Li-S) battery has been proposed and investigated since the 1960s as an effective energy storage device via reversible electrochemical reactions. As the fast development and commercialization of Li-ion battery (LIB) technology kept moving forward, no breakthroughs have been attained to solve critical technical issues facing Li-S batteries during the following decades. In the year 2000s, Li-S batteries reattracted significant interests in the research field owing to their low-cost advantages, high theoretical specific energy of 2600 Wh kg -1 , which is at least 3 times higher than the current LIB technology. The low-cost and high abundance of sulfur (i.e., the cathode active material), make Li-S batteries more appealing than LIBs given the fact that the latter use critical materials such as cobalt and nickel in the manufacturing of the cathodes. Moreover, the high-energy and low-cost features make the Li-S battery a promising energy storage technology in practical applications such as portable devices, electric vehicles, and grid storage when coupled with the harvesting of solar or wind renewable energies. For example, since 2007, SION Power Corporation (Tucson, USA) and Oxis Energy (UK) made progress towards the commercialization of Li-S batteries with products showing specific energies over 350 Wh kg -1 for powering electric vehicles. To be on a par with the current LIB technology, the ultimate goal of achieving 500 Wh kg -1 for Li-S battery will make it more competitive for widespread commercialization.

Li, Mengya↗

Feasibility Study of Economics and Performance of Solar Photovoltaics at the Vincent Mullins Landfill in Tucson, Arizona

The U.S. Environmental Protection Agency (EPA), in accordance with the RE-Powering America's Land initiative, selected the Vincent Mullins Landfill in Tucson, Arizona, for a feasibility study of renewable energy production. Under the RE-Powering America's Land initiative, the EPA provided funding to the National Renewable Energy Laboratory (NREL) to support the study. NREL provided technical assistance for this project but did not assess environmental conditions at the site beyond those related to the performance of a photovoltaic (PV) system. The purpose of this report is to assess the site for a possible PV installation and estimate the cost and performance of different PV configurations, as well as to recommend financing options that could assist in the implementation of a PV system. In addition to the Vincent Mullins site, four similar landfills in Tucson are included as part of this study. The feasibility of a PV system depends greatly on both site-specific and economic factors. Site specific factors include the available area for an array, solar resource, distance to transmission lines, and distance to major roads. In addition, the operating status, ground conditions, and restrictions associated with redevelopment of contaminated sites impact the feasibility of a PV system. Economic factors include purchase price of the electricity produced, power purchase agreement (PPA) price, and retail electric rates along with federal, state, and utility incentives for PV systems. Based on an assessment of these factors, the Vincent Mullins Landfill and other closed landfills in Tucson were found to be suitable sites for deployment of utility-scale PV systems. This study evaluated two development scenarios for implementing large-scale PV systems on Tucson’s landfills—one in which the city owns and operates the system, and one where a private entity is allowed to develop the site using a PPA. Table ES-1 summarizes the predicted economics of the two scenarios along with the system size, energy production, and cost.

14 SOLAR ENERGY↗

Controlled Hydrogen Fleet and Infrastructure Demonstration and Validation Project Final Technical Report

This report summarizes the work conducted under U.S. Department of Energy (US DOE) contract DE-FC36-04GO14286 by Chevron Technology Ventures (CTV, a division of Chevron U.S.A., Inc.), Hyundai Motor Company (HMC), and UTC Power (UTCP, a United Technologies company) to validate hydrogen (H2) infrastructure technology and fuel cell hybrid vehicles. Chevron established hydrogen filling stations at fleet operator sites using multiple technologies for on-site hydrogen generation, storage, and dispensing. CTV constructed five demonstration stations to support a vehicle fleet of 33 fuel cell passenger vehicles, eight internal combustion engine (ICE) vehicles, three fuel cell transit busses, and eight internal combustion engine shuttle busses. Stations were operated between 2005 and 2010. HMC introduced 33 fuel cell hybrid electric vehicles (FCHEV) in the course of the project. Generation I included 17 vehicles that used UTCP fuel cell power plants and operated at 350 bar. Generation II included 16 vehicles that had upgraded UTC fuel cell power plants and demonstrated options such as the use of super-capacitors and operation at 700 bar. All 33 vehicles used the Hyundai Tucson sports utility vehicle (SUV) platform. Fleet operators demonstrated commercial operation of the vehicles in three climate zones (hot, moderate, and cold) and for various driving patterns. Fleet operators were Southern California Edison (SCE), AC Transit (of Oakland, California), Hyundai America Technical Center Inc. (HATCI), and the U.S. Army Tank Automotive Research, Development and Engineering Center (TARDEC, in a site agreement with Selfridge Army National Guard Base in Selfridge, Michigan).

08 HYDROGEN↗

Focus on monitoring and control of complex supply systems

The ongoing rapid transformation of our energy supply challenges the operation and stability of electric power grids and other supply networks. This focus issue comprises new ideas and concepts in the monitoring and control of complex networks to address these challenges.

97 MATHEMATICS AND COMPUTING↗

Gigahertz-frequency acousto-optic phase modulation of visible light in a CMOS-fabricated photonic circuit

Optical phase modulators operating at visible wavelengths are essential components for photonic technologies such as those for quantum control, communications, and laser ranging. However, they remain challenging to implement in scalable, integrated platforms capable of handling high optical powers. Here we present a visible-light, gigahertz-frequency acousto-optic phase modulator, fabricated on a 200-mm wafer in a volume CMOS foundry, that supports greater than 500 mW of optical power at 730 nm. The device combines a piezoelectric transducer and a photonic waveguide within a single, wavelength-scale structure that confines both a propagating optical mode and an electrically excitable breathing-mode mechanical resonance. By tuning the device’s geometry to optimize the optomechanical interaction, we achieve modulation depths up to 4.85 rad with 80 mW of applied microwave power at 2.31 GHz in a 2-mm-long device. This corresponds to resonant modulation figures of merit of V π = 1.32V and V π ⋅ L = 0.26V cm. To our knowledge, this is the lowest V π ever demonstrated in any acousto-optic phase modulator and represents a 15-fold reduction in V π and a 100-fold reduction in required microwave power relative to state-of-the-art modulators with high visible-wavelength power handling commonly employed in quantum control systems.

Freedman, Jacob M. [Univ. of Arizona, Tucson, AZ (↗

Thermal Resilience of Residential Building with Thermally Anisotropic Building Envelope Connected to Geothermal Sources

Heat waves and cold snaps have become more frequent and more intense because of climate change. A heat wave and a cold snap are a period of excessively hot and cold weather, respectively, that poses severe risks to building occupants’ health, especially for vulnerable people. They increase electrical energy consumption and put high stress on the grid which leads to potential power outages. Therefore, it is critical to assess and actively improve the thermal resilience of buildings to cope with heat waves, cold snaps, and power outages. The thermally anisotropic building envelope (TABE) is a novel active building envelope that can save energy while maintaining thermal comfort in buildings by redirecting heat and coolness from building envelopes to hydronic loops. When connecting to a ground thermal loop (GL), TABE can utilize the relatively stable temperature of the ground to protect the indoor environment during heat waves and cold snaps. This study assesses the thermal resilience of residential buildings that installed TABE and used ground thermal energy to supply the hydronic loops, abbreviated as ground thermal loop or TABE+GL. The simulation and analysis are conducted for the US Department of Energy prototype single-family detached residential building in the hot climate of Miami, Florida and Tucson, Arizona, and the cold climate of Denver, Colorado, and Rochester, Minnesota. Heat waves and cold snaps were obtained from the historical weather data of 1998-2020 for the studied regions. Three thermal resilience metrics, including the standard effective temperature (SET) degree-hours, the Heat Index, and the Hours of Safety (HOS) were used to quantify the effect of TABE+GL. The results showed that buildings installed TABE+GL could significantly reduce the average SET degree-hours above 30°C, increase HOS, and greatly improve thermal resilience.

Shen, Zhenglai↗

In Situ Electrochemistry of Buried Interfaces in Metal Halide Perovskites: Probing Energy Bands, Halide Redox Activity, and Kinetics

Control over charge injection and extraction processes across buried interfaces is fundamental for all (opto)electronic multilayer device platforms, necessitating detailed understanding of local structural and chemical differences that promote defect formation, distort energetic band-edge alignments, and alter charge transport processes. Herein, the implementation of a low-cost electroanalytical methodologies’ tool suite is described to quantitatively characterize buried interfaces and redox reactions in printable, mixed electrical–ionic, and redox-active metal halide perovskites and a prototypical hole-transporting nickel oxide (NiO x ) thin film. The objective is to demonstrate the power of electrochemical methodologies to improve the nanoscale understanding of complex interfaces within optoelectronic devices by providing case studies on how to: i) differentiate between electronic and chemical properties in NiO x contacts; ii) measure changes in reversibility of halide redox reactions via NiO x surface states; iii) assess energy alignment and charge transport across (modified) buried interfaces; and iv) quantify defects at buried interfaces that change with modifiers and differences in perovskite processing, including increasing defect concentrations when films are slot-die-coated versus spin-cast. The collective approach addresses major challenges in understanding the precise energy landscape and interface reactivity under relevant electric fields that mimic operando conditions (away from equilibrium) and across length scales in thin film device formats.

(spectro)electrochemistry↗

Distributed Energy Resource (DER) Integration Framework: Regulatory Innovation for DER Compensation and Cost Allocation

Existing regulatory approaches to DER lack the precision and granularity necessary to ensure that DER can continue to scale in a cost-effective manner that is aligned with the public interest. To address this need, with the support of the U.S. Department of Energy’s Office of Electricity, Berkeley Lab and Current Energy Group developed an illustrative regulatory framework. By adopting a technology-neutral and modular approach, the framework enables flexibility and scalability for DER providers, utilities, and regulators. Clear price signals and incentives encourage the provision of valuable grid services, while equitable cost allocation promotes efficient use of distribution capacity and interconnection resources. This approach mirrors traditional ratemaking principles for importing customers and positions DERs as integral components of a dynamic and cost-effective energy future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Degradation Dynamics of Perovskite Solar Cells Under Fixed Reverse-Current Injection

Previous studies of reverse-bias stability in perovskite solar cells have focused primarily on voltage-controlled tests. Here we instead investigate perovskite solar cell degradation under well-defined, constant reverse-current stress. We show that the choice of hole-transport layer dictates the dominant degradation pathway: cells using thick poly(triphenylamine) (PTAA) layers can tolerate high reverse bias but quickly undergo catastrophic breakdown under fixed reverse current near their one-sun maximum power-point. In contrast, cells modified with phosphonic-acid interface layer MeO-2PACz, with poorer indium-doped tin oxide (ITO) coverage compared to PTAA, exhibit gradual and recoverable degradation under certain stress and recovery conditions. For MeO-2PACz devices, degradation increases with both current magnitude and duration. Importantly, when normalized by injected charge (current times duration), lower currents applied over longer times cause more degradation than higher currents over shorter periods. Here, combining electrical measurements with spatially resolved photoluminescence imaging, our observations support an ion- and charge-mediated interfacial electrochemical degradation mode.

Degradation↗

Monolithic AlScN/SiC phononic waveguides for scalable acoustoelectric and quantum devices

Unlike conventional surface acoustic wave devices, phononic waveguide systems enable higher circuit density and stronger strain and piezoelectric fields, making them promising for advanced acoustoelectric and quantum applications. One such material system for generating and guiding phonons at gigahertz frequencies is AlScN on SiC, which can be synthesized by sputter depositing AlScN directly onto SiC wafers. The AlScN on the SiC platform allows for tightly vertically-confined acoustic modes with high electromechanical coupling, high speed of sound, and simple fabrication of strip and rib waveguides. Until now, this system has only been studied as a slab waveguide platform, i.e., without any lateral waveguiding. Here, we demonstrate a two-dimensionally confined phononic architecture in AlScN on SiC that supports guided modes at 2.95 and 4.05 GHz. These modes exhibit strong electromechanical coupling coefficients (k 2 = 4.27%) and propagation losses on the order of 10 dB/mm. Furthermore, this architecture is well-suited for phononic routing and power-efficient active or nonlinear devices such as amplifiers, mixers, and oscillators, and is compatible with the integration of quantum systems, including vacancy centers, charge carriers, photons, and spins, either embedded in SiC or heterogeneously integrated on the surface.

Electrical components↗