Search NASA⌕ Search

SEARCH · Search NASA

Results for “Turbine Cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Optimization of engines for a commercial Mach 0.85 transport using advanced turbine cooling methods

A parametric study was made of a group of separate-flow-turbofan engines for use in advanced technology airplanes designed for a cruise Mach number of 0.85 at 40,000 feet. The three-engined airplanes were sized to carry 200 passengers 3000 nautical miles. Supercritical aerodynamics were assumed. Film-cooled turbines were used and sea-level-static turbine-rotor-inlet temperature was always 2600 F. The optimum cycle depends on the noise goal assumed. Without a noise goal the best fan pressure ratio (FPR) is about 1.90. At noise goals of FAR 36, -10 EPNdb, and -20 EPNdb, the best FPR's are 1.85, 1.76, and 1.70, respectively, at cruise. The take-off FPR's are progressively less than the cruise value as the noise goal approaches -20 EPNdb. The penalties in take-off gross weight incurred were 8.5, 19, and 64 percent at goals of FAR 36, -10 EPNdb, and -20 EPNdb, respectively.

Kraft, G. A.↗

Preliminary analysis of problem of determining experimental performance of air-cooled turbine II : methods for determining cooling-air-flow characteristics

In the determination of the performance of an air-cooled turbine, the cooling-air-flow characteristics between the root and the tip of the blades must be evaluated. The methods, which must be verified and the unknown functions evaluated, that are expected to permit the determination of pressure, temperature, and velocity through the blade cooling-air passages from specific investigation are presented.

FLOW, COMPRESSIBLE↗

Radial turbine cooling

Radial turbines have been used extensively in many applications including small ground based electrical power generators, automotive engine turbochargers and aircraft auxiliary power units. In all of these applications the turbine inlet temperature is limited to a value commensurate with the material strength limitations and life requirements of uncooled metal rotors. To take advantage of all the benefits that higher temperatures offer, such as increased turbine specific power output or higher cycle thermal efficiency, requires improved high temperature materials and/or blade cooling. Extensive research is on-going to advance the material properties of high temperature superalloys as well as composite materials including ceramics. The use of ceramics with their high temperature potential and low cost is particularly appealing for radial turbines. However until these programs reach fruition the only way to make significant step increases beyond the present material temperature barriers is to cool the radial blading.

Roelke, Richard J.↗

Turbine cooling research

Development of improved turbine cooling processes and facilities for conducting turbine cooling research

Cochran, R. P.↗

Engine investigation of an air-cooled turbine rotor blade incorporating impingement-cooled leading edge, chordwise passages, and a slotted trailing edge

Experimental temperatures are presented for an air-cooled turbine rotor blade tested in an engine. The data were obtained for turbine stator inlet temperatures from 2000 to 2500 F and for turbine-inlet gas pressures from 32 to 46 psia. Average and local blade heat-transfer data are correlated. Potential allowable increases in gas temperature are also discussed.

Dengler, R. P.↗

Air-Cooled Turbine Blades with Tip Cap For Improved Leading-Edge Cooling

An investigation was conducted in a modified turbojet engine to determine the cooling characteristics of the semistrut corrugated air- cooled turbine blade and to compare and evaluate a leading-edge tip cap as a means for improving the leading-edge cooling characteristics of cooled turbine blades. Temperature data were obtained from uncapped air-cooled blades (blade A), cooled blades with the leading-edge tip area capped (blade B), and blades with slanted corrugations in addition to leading-edge tip caps (blade C). All data are for rated engine speed and turbine-inlet temperature (1660 F). A comparison of temperature data from blades A and B showed a leading-edge temperature reduction of about 130 F that could be attributed to the use of tip caps. Even better leading-edge cooling was obtained with blade C. Blade C also operated with the smallest chordwise temperature gradients of the blades tested, but tip-capped blade B operated with the lowest average chordwise temperature. According to a correlation of the experimental data, all three blade types 0 could operate satisfactorily with a turbine-inlet temperature of 2000 F and a coolant flow of 3 percent of engine mass flow or less, with an average chordwise temperature limit of 1400 F. Within the range of coolant flows investigated, however, only blade C could maintain a leading-edge temperature of 1400 F for a turbine-inlet temperature of 2000 F.

Calvert, Howard F.↗

Preliminary analysis of effects of air cooling turbine blades on turbojet-engine performance

The effects of turbine-blade cooling on engine performance were analytically investigated for a turbojet engine in which cooling air is bled from the engine compressor. The analysis was made for a constant turbine-inlet temperature and a range of altitudes to determine the minimum cooling requirements to permit substitution of nonstrategic materials in turbine blading. The results indicate that, for a constant inlet temperature, air cooling of the turbine blades increases the specific fuel consumption and decreases the thrust of the engine. The highest possible cooling effectiveness is desirable to minimize coolant weight flow and its effects on engine performance.

COOLING - GAS-TURBINE SYSTEMS↗

Analysis of temperature distribution in liquid-cooled turbine blades

The temperature distribution in liquid-cooled turbine blades determines the amount of cooling required to reduce the blade temperature to permissible values at specified locations. This report presents analytical methods for computing temperature distributions in liquid-cooled turbine blades, or in simplified shapes used to approximate sections of the blade. The individual analyses are first presented in terms of their mathematical development. By means of numerical examples, comparisons are made between simplified and more complete solutions and the effects of several variables are examined. Nondimensional charts to simplify some temperature-distribution calculations are also given.

Livingood, John N B↗

Algorithm for calculating turbine cooling flow and the resulting decrease in turbine efficiency

An algorithm is presented for calculating both the quantity of compressor bleed flow required to cool the turbine and the decrease in turbine efficiency caused by the injection of cooling air into the gas stream. The algorithm, which is intended for an axial flow, air routine in a properly written thermodynamic cycle code. Ten different cooling configurations are available for each row of cooled airfoils in the turbine. Results from the algorithm are substantiated by comparison with flows predicted by major engine manufacturers for given bulk metal temperatures and given cooling configurations. A list of definitions for the terms in the subroutine is presented.

Gauntner, J. W.↗

Effects of turbine cooling assumptions on performance and sizing of high-speed civil transport

The analytical study presented examines the effects of varying turbine cooling assumptions on the performance of a high speed civil transport propulsion system as well as the sizing sensitivity of this aircraft to these performance variations. The propulsion concept employed in this study was a two spool, variable cycle engine with a sea level thrust of 55,000 lbf. The aircraft used for this study was a 250 passenger vehicle with a cruise Mach number of 2.4 and 5000 nautical mile range. The differences in turbine cooling assumptions were represented by varying the amount of high pressure compressor bleed air used to cool the turbines. It was found that as this cooling amount increased, engine size and weight increased, but specific fuel consumption (SFC) decreased at takeoff and climb only. Because most time is spent at cruise, the SFC advantage of the higher bleed engines seen during subsonic flight was minimized and the lower bleed, lighter engines led to the lowest takeoff gross weight vehicles. Finally, the change in aircraft takeoff gross weight versus turbine cooling level is presented.

Senick, Paul F.↗

Effects of turbine cooling assumptions on performance and sizing of high-speed civil transport

The analytical study presented examines the effects of varying turbine cooling assumptions on the performance of a high speed civil transport propulsion system as well as the sizing sensitivity of this aircraft to these performance variations. The propulsion concept employed in this study was a two spool, variable cycle engine with a sea level thrust of 55,000 lbf. The aircraft used for this study was a 250 passenger vehicle with a cruise Mach number of 2.4 and 500 nautical mile range. The differences in turbine cooling assumptions were represented by varying amount of high pressure compressor bleed air used to cool the turbines. It was found that as this cooling amount increased, engine size and weight increased, but specific fuel consumption (SFC) decreased at takeoff and climb only. Because most time is spent at cruise, the SFC advantage of the higher bleed engines seen during subsonic flight was minimized and the lower bleed, lighter engines led to the lowest takeoff gross weight vehicles. Finally, the change in aircraft takeoff gross weight versus turbine cooling level is presented.

Senick, Paul F.↗

Real-Time Closed Loop Modulated Turbine Cooling

It has been noted by industry that in addition to dramatic variations of temperature over a given blade surface, blade-to-blade variations also exist despite identical design. These variations result from manufacturing variations, uneven wear and deposition over the life of the part as well as limitations in the uniformity of coolant distribution in the baseline cooling design. It is proposed to combine recent advances in optical sensing, actuation, and film cooling concepts to develop a workable active, closed-loop modulated turbine cooling system to improve by 10 to 20 the turbine thermal state over the flight mission, to improve engine life and to dramatically reduce turbine cooling air usage and aircraft fuel burn. A reduction in oxides of nitrogen (NOx) can also be achieved by using the excess coolant to improve mixing in the combustor especially for rotorcraft engines. Recent patents filed by industry and universities relate to modulating endwall cooling using valves. These schemes are complex, add weight and are limited to the endwalls. The novelty of the proposed approach is twofold 1) Fluidic diverters that have no moving parts are used to modulate cooling and can operate under a wide range of conditions and environments. 2) Real-time optical sensing to map the thermal state of the turbine has never been attempted in realistic engine conditions.

turbines↗