Search NASA⌕ Search

SEARCH · Search NASA

Results for “Turbine replacement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Self-Lubricating Bushing Testing for John Day Dam Ka plan Turbine Replacement

The goal of this testing program is to find suitable self-lubricated alternatives to replace the in use oil lubricated grooved-bronze bushing in Kaplan runner hubs that are currently being utilized at John Day Dam operated by the U.S. Army Corps of Engineers (USACE). Scaled bushing testing utilizing a Pacific Northwest National Laboratory designed, fabricated, and operated Bushing Test Stand under the direction and funding from USACE determined that self-lubricated bushings tested appear capable of outperforming the current oil-lubricated bronze bushings. Performance tests are focused on durability which includes cyclic load bearing properties and articulations under various loading scenarios. This testing was performed at nominally 1/5 th scale. A scaling sensitivity analysis determined that scaled testing results apply to prototypic size. This report shows the direct comparison between the current baseline bronze bushing to self-lubricated bushings from various manufacturers. Bushing data like coefficient of friction and bushing material loss (associated with bushing wear) was determined. Self-lubricated bushings tested include products manufactured specifically for hydropower applications by the following companies: Trelleborg, Kamatics, Anonymous, and Tenneco/Deva.

42 ENGINEERING↗

Biological Response Models: Predicting Injury and Mortality of Fish During Downstream Passage through Hydropower Facilities

This report describes the U.S. Department of Energy’s HydroPASSAGE project efforts to develop and collect biological response models for integration into the Biological Performance Assessment (BioPA) toolset and the Hydropower Biological Evaluation Toolset (HBET). These models help understand how fish are likely to respond during dam passage when exposed to hydraulic and physical stressors associated with turbines and other hydropower structures. When fish pass through hydropower facilities, they may encounter several stressors, of which the three most common are collision, rapid decompression, and fluid shear. Specialized equipment has been used to develop 99 biological response models for exposure to blade strike, rapid decompression, or fluid shear. The models were gathered from the literature or developed as part of this effort and include models for 31 different species of fish that have various predicted endpoints (i.e., injury or mortality). Among these models, considerable variation in susceptibility to the stressors has been observed from one species to another, and a species’ susceptibility to one stressor does not necessarily indicate similar susceptibility to another. Although several species have been examined, it is still unclear how many other species, which may have different morphological traits, may respond to these stressors, so further examination of the different species is needed. These models can and have been applied in several different cases, often using the BioPA toolset and HBET, to better understand the potential for injury and mortality that may occur during fish passage at hydropower facilities, including specific applications, such as turbine replacement, the installation of new turbines, or changing operations of currently installed turbines. As hydropower is continually developed to meet the electricity needs of society, tools such as HBET and BioPA, used with the integrated biological response models, will aid in the development of technologies and strategies that avoid, minimize, mitigate, or manage environmental effects.

13 HYDRO ENERGY↗

Integration of Pumped Heat Energy Storage with Fossil-Fired Power Plant (Final Report)

The project team of Southwest Research Institute ® (SwRI ® ), Malta Inc. (Malta), and Luminant Generation Company LLC (Luminant) completed a feasibility study for the integration of a 100-MW, 10-hour (1000-MWh) Malta Pumped Heat Energy Storage (MPHES) system with multiple full-sized fossil-fired electricity generation units (EGU) in Luminant portfolio. MPHES is a long-duration, molten-salt-energy storage technology that uses turbomachinery and heat exchangers to transfer energy to a thermal storage media when charging, and removes the heat in a similar fashion when discharging. With high round trip efficiency (60-65%) and long lifespan (30+ years), MPHES provides economic benefits to the fossil-asset owners that can be scaled to integrate with assets across their portfolio. This technology uses hardware components, workforce personnel, and skillsets similar to those used by fossil EGUs, allowing for synergy when co-locating the two technologies. Luminant has approximately 39,000 megawatts of generation across 12 states, operating in six of the seven competitive markets in the U.S. and powered by a diverse portfolio of natural gas, nuclear, coal, and solar facilities. The DeCordova plant in Granbury, Texas, a simple cycle natural gas peaker power plant, was used as the fossil-fired asset in this project. The local market in Granbury, Texas has many influences, including several nearby power plants, a Luminant-owned nuclear plant (Comanche Peak), and substantial wind energy, which causes both negative pricing at night and high market volatility. Reducing false starts of the DeCordova plant and better responding to market volatility would be an economic advantage. Luminant is currently integrating battery storage plant on site to begin addressing these challenges. Integrating long-duration storage, like MPHES, would expand this capability beyond one hour of storage and have the potential to greatly reduce the total number of gas turbine starts. The MPHES charging requirement could help offset the overnight operating costs of Comanche Peak, which cannot load follow, and the nearby Luminant-owned Wise County combined cycle plant that cycles too often. Following the assessment of Luminant’s ERCOT-based portfolio for integration compatibility with Malta’s PHES system and the project tasks of conceptual study, technoeconomic analysis, technology gap assessment, and commercialization plan, the project team effort has resulted in several key outcomes: (1) Identification of market trends in a high-wind penetration market outside a major metropolitan area; (2) Creation of a dispatching model for the MPHES system and the pairing of Li-ion battery with a gas turbine in a real time market; (3) Revenue and cost estimations for operating MPHES alongside a gas peaker plant with real dispatching considerations and comparison with variations in the Malta implementation, including doubling the storage capacity and using two discharge drivetrains; (4) Potential carbon emission reductions possible by replacing gas turbine operation with Malta PHES operation; and (5) Summary of literature-based future market predictions for Texas.

20 FOSSIL-FUELED POWER PLANTS↗

Update on Model Specification Development of Ternary Pumped Storage Technologies [Slides]

T-PSH is an innovative structure of C-PSH that features two turbines, one for pumping and one for generation, replacing the single turbine in C-PSH. These turbines are housed in separate chambers, with an additional set of penstocks connecting the pump turbine to the hydraulic system. This structure enables T-PSH to operate in an HSC mode, allowing for simultaneous pumping and generation, which provides greater operational flexibility compared to C-PSH. To model T-PSH's HSC mode, a user defined turbine and governor system model is required, including the shared penstock model and additional pump turbine model. This specification will focus on the details of the user-defined turbine and governor model, which leverages the HYGOV model.

16 TIDAL AND WAVE POWER↗

A Revised International Standard for Gearboxes in Wind Turbine Systems

Gearbox and wind turbine design and application standards have contributed significantly to improvements in reliability over the past two decades. The International Electrotechnical Commission (IEC) 61400-4 standard of wind turbine gearbox design is currently being revised by a joint working group (JWG) of experts in IEC TC 88 (wind energy) and International Organization for Standardization (ISO) TC60 (gears) to further that effort. Experts from ISO TC4 (rolling bearings) and ISO TC28 (lubricants) have actively participated. This revision has implemented lessons learned from industry use of edition 1 since its publication in 2012. The main document, IEC 61400-4, was pared down to essential design requirements and application-specific recommendations along with a design verification framework. The JWG leveraged concurrent development of other standards, such as IEC 61400-8 on wind turbine structures, to replace edition 1 content. These are described along with how this works with the IEC Renewable Energy certification scheme for wind turbines (IECRE-WE). The JWG recognized the interest in maintaining informative parts of edition 1 including annexes on wind turbine architecture and loads, bearing and gear arrangements, bearing selection, lubrication system descriptions and lubricant performance recommendations. This information was retained in two technical reports: IEC/TR 61400-4-2 Lubrication and IEC/TR 61400-4-3 Explanatory Notes. Additionally, a technical specification, IEC/TS 61400-4-1, was drafted to provide a reliability calculation method for comparing different design options or conditions. Salient elements of these documents are described. All four documents were recently distributed for IEC/ISO review, ballot, and comment. Publication is expected in 2023.

gearbox↗

A Revised International Standard for Gearboxes in Wind Turbine Systems: Preprint

Gearbox and wind turbine design and application standards have contributed significantly to improvements in reliability over the past two decades. The International Electrotechnical Commission (IEC) 61400-4 standard of wind turbine gearbox design is currently being revised by a joint working group (JWG) of experts in IEC TC 88 (wind energy) and International Organization for Standardization (ISO) TC60 (gears) to further that effort. Experts from ISO TC4 (rolling bearings) and ISO TC28 (lubricants) have actively participated. This revision has implemented lessons learned from industry use of edition 1 since its publication in 2012. The main document, IEC 61400-4, was pared down to essential design requirements and application-specific recommendations along with a design verification framework. The JWG leveraged concurrent development of other standards, such as IEC 61400-8 on wind turbine structures, to replace edition 1 content. These are described along with how this works with the IEC Renewable Energy certification scheme for wind turbines (IECRE-WE). The JWG recognized the interest in maintaining informative parts of edition 1 including annexes on wind turbine architecture and loads, bearing and gear arrangements, bearing selection, lubrication system descriptions and lubricant performance recommendations. This information was retained in two technical reports: IEC/TR 61400-4-2 Lubrication and IEC/TR 61400-4-3 Explanatory Notes. Additionally, a technical specification, IEC/TS 61400-4-1, was drafted to provide a reliability calculation method for comparing different design options or conditions. Salient elements of these documents are described. All four documents were recently distributed for IEC/ISO review, ballot, and comment. Publication is expected in 2023.

ENGINEERING,WIND ENERGY↗

Phase stability and tensorial thermal expansion properties of single to high-entropy rare-earth disilicates

Temperature limitations in nickel-base superalloys have resulted in the emergence of SiC-based ceramic matrix composites as a viable replacement for gas turbine components in aviation applications. Higher operating temperatures allow for reduced fuel consumption but present a materials design challenge related to environmental degradation. Rare-earth disilicates (RE 2 Si 2 O 7 ) have been identified as coatings that can function as environmental barriers and minimize hot component degradation. In this work, single- and multiple-component rare-earth disilicate powders were synthesized via a sol-gel method with compositions selected to exist in the monoclinic C 2/m phase (β phase). Phase stability in multiple cation compositions was shown to follow a rule of mixtures and the C 2/m phase could be realized for compositions that contained up to 25% dysprosium, which typically only exists in a triclinic, P $\bar1$, phase. All compositions exhibited phase stability from room temperature to 1200°C as assessed by X-ray diffraction. The thermal expansion tensors for each composition were determined from high-temperature synchrotron X-ray diffraction and accompanying Rietveld refinements. It was observed that ytterbium-containing compositions had larger changes in the α 31 shear component with increasing temperature that led to a rotation of the principal axes. Principal axes rotation of up to 47° were observed for ytterbium disilicate. The results suggest that microstructure design and crystallographic texture may be essential future avenues of investigation to ensure thermo-mechanical robustness of rare-earth disilicate environmental barrier coatings.

36 MATERIALS SCIENCE↗

Understanding EBC Lifetimes and Performance for Industrial Gas Turbines

Hydrogen or hydrogen blend fuels are expected to replace natural gas in land-based industrial gas turbines (IGTs) to support a greener power economy. Silicon carbide (SiC) base ceramic matrix composites (CMCs) are considered for replacement of Ni-based superalloys to facilitate future efficiency improvements. SiC CMCs require environmental barrier coatings (EBCs) to mitigate volatilization from high-temperature steam, thus making the EBC lifetime critical information for identifying CMC component lifetimes. The goal of this project is to determine the maximum bond coating temperature underneath the EBC for achieving an IGT component lifetime goal of 25,000 h, which is far greater than current CMC component lifetime requirements for aero-turbine applications. To provide data for the lifetime model, laboratory testing used plasma-sprayed rare-earth silicate EBCs on monolithic SiC substrates with an intermediate Si bond coating. Specimens exposed to 1-h thermal cycles in flowing air-steam environments and reaction kinetics were assessed from 700°-1350°C by measuring the thickness of the thermally grown silica scales. The silica growth and phase transformation appear critical in predicting EBC lifetime and several strategies have been explored to reduce the oxide growth rate and improve EBC durability at elevated temperatures. Advanced characterization using Raman spectroscopy has helped clarify this system.

Ridley, Mackenzie↗

Understanding Environmental Barrier Coating Lifetimes and Performance for Industrial Gas Turbines

Hydrogen or hydrogen blend fuels are expected to replace natural gas in land-based industrial gas turbines (IGTs) to support a greener power economy. Silicon carbide (SiC) base ceramic matrix composites (CMCs) are considered for replacement of Ni-based superalloys to facilitate future efficiency improvements. SiC CMCs require environmental barrier coatings (EBCs) to mitigate volatilization from high-temperature steam, thus making the EBC lifetime critical information for identifying CMC component lifetimes. Here, the goal of this project is to determine the maximum bond coating temperature underneath the EBC for achieving an IGT component lifetime goal of 25,000 h, which is far greater than current CMC component lifetime requirements for aeroturbine applications. To provide data for the lifetime model, laboratory testing used atmospheric plasma-sprayed rare-earth silicate EBCs on monolithic SiC substrates with an intermediate Si bond coating. Specimens exposed to 1-h thermal cycles in flowing air–steam environments and reaction kinetics were assessed from 700 °C to 1350 °C by measuring the thickness of the thermally grown silica scales. The silica growth and phase transformation appear critical in predicting EBC lifetime and several strategies have been explored to reduce the oxide growth rate and improve EBC durability at elevated temperatures. Advanced characterization using Raman spectroscopy has helped clarify this system.

08 HYDROGEN↗

In situ characterization of the biological performance of a Francis turbine retrofitted with a modular guide vane

There are two strategies to lower overall project costs to an extent that will make many potential sustainable hydropower sites economically viable: (1) design standardized/modular components; (2) use advanced tools to reduce environmental evaluation costs. In this study an autonomous sensor device (Sensor Fish) was used to study a Francis turbine retrofitted with a modular guide vane. The median nadir pressures measured were 74.7, 66.6, and 56.6 kPaA for 90-, 190-, and 380-kW operating conditions respectively. These nadir pressures were compared to other Francis turbines studied using Sensor Fish and were found to be within the same range. The proportion of Sensor Fish releases with severe acceleration events (acceleration = 95G) was also investigated. The proportion ranged from 73 to 80% (runner region), 50 to 64% (guide vane region), and 9 to 28% (draft tube region), which was within the range of the other turbines used for comparison. The Sensor Fish testing that was conducted at Hurley Dam demonstrates that the modular guide vane that was retrofitted to the existing Francis turbine is potentially a suitable replacement that can provide biological performance similar to the guide vane used with other existing Francis turbines, but with the benefit of reduced fabrication costs.

13 HYDRO ENERGY↗

Assessment of Consensus and Wake Steering Wind Farm Control for the American WAKE ExperimeNt (AWAKEN)

As part of the AmericanWAKE ExperimeNt (AWAKEN), a wind farm control experiment is being conducted at the King Plains wind plant in northern Oklahoma from May 2024 to summer 2025. Two types of wind farm control are being evaluated: 1) wake steering, in which upstream wind turbines are misaligned relative to the wind direction to deflect their wakes away from downstream turbines and increase total wind plant power, and 2) consensus yaw control, whereby each turbine's yaw position is controlled to track a "consensus" weighted average of the wind directions measured at neighboring turbines rather than the turbine's own nacelle wind direction measurement. By replacing the noisy wind direction measured by an individual turbine with the smoother, more slowly varying consensus wind direction, consensus yaw control is intended to reduce yaw activity and increase power capture by improving yaw alignment. To help balance the potential increase in yaw activity for the turbines implementing wake steering, they are also operated using consensus yaw control. In this presentation we highlight the impacts of consensus yaw control and wake steering on both energy production and yaw travel at the wind plant. Results show that the change in energy from wake steering is minor overall, but significant increases in energy are observed for closely spaced turbines. Further, larger increases in energy occur during low turbulence periods. The impact of consensus yaw control on energy production is currently inconclusive, with some energy gains measured for some turbines and losses measured for others. Lastly, consensus yaw control was found to reduce yaw travel significantly, even when combined with wake steering.

17 WIND ENERGY↗

Market-Integrated Optimization of Wind-Battery-Hydrogen Hybrids for Peaking Capacity via Storage

As Integrated Energy Systems (IES) combine multiple energy and storage technologies to provide potentially more value and less risk via resource diversification, complementary overbuild, increased flexibility, and revenue-stacking, IES value is dependent on electricity market dispatch and grid interactions should play an important role in IES design and operation. This study hybridizes and retrofits wind and combustion turbine plants to study the impacts of replacing gas generation capacity with wind, battery, PEM electrolysis, hydrogen tanks and hydrogen turbines. The optimized design is co-simulated in a production cost model with different bidding strategies in order to compare performance and highlight the importance of grid-interactions. We analyze the revenue and dispatch changes as well as the price and cost implications of wind-battery-hydrogen IESs.

electrolysis↗

Pitch Bearing Rating and Service Life Analysis

Pitch bearings are an essential component in wind turbines used to connect the blade root to the hub. They support the resulting simultaneous radial, axial, and overturning moment loads while allowing relative rotation of the blade to the hub. The most recent evidence indicates the replacement rate for pitch bearings on 3+ MW turbines can be several percent per year, reaching 10% by year 5. This is a far higher replacement rate than both older 1.5 to 2 MW turbines and 2 to 3 MW turbines, which only reach a 10% replacement rate by 14 to 24 years compared to the expected design life of at least 20 years. Typical pitch bearing replacements require the use of a large, expensive crane and removal of the blade(s) or rotor, with a significant amount of downtime. Given the most recent developments in pitch bearing reliability and the publication of the updated NREL and Fraunhofer IWES pitch bearing design guide, the purpose of this report is to update the performance and rating analysis of the example 1.9-meter diameter pitch bearing representative of that installed on a 1.5 MW wind turbine, compare the rating life to the observed service life of similar pitch bearings, and validate the service life modification factor with this large population of bearings. The report will also summarize the pitch bearing contact conditions, thereby serving as a guide for planned bench-level fretting wear tests at Argonne National Laboratory.

17 WIND ENERGY↗

Experimental Investigation of Concrete Fatigue in Axial Compression

The use of concrete in fatigue critical structures, such as wind turbine towers, has necessitated the replacement of simplistic (and therefore insufficient) fatigue design recommendations with more accurate and advanced fatigue models that can consider a greater complexity of stress states and materials. As the first part of a multistage test series, an experimental investigation was conducted to determine the fatigue life of concrete subjected to axial compressive fatigue loading, focusing on the relatively high-cycle fatigue domain. Here, a wide range of values for maximum stress levels and stress ratios were considered. The experimental results were compared against existing predictive models, and the most applicable model was identified. Concrete strain and stiffness behavior during fatigue loading were also investigated and reported. Based on the observed behavior, a hypothesis for identifying the impending occurrence of fatigue failure, based on the monotonic stress-strain curve, is examined.

17 WIND ENERGY↗

Main Bearing Replacement and Damage - A Field Data Study on 15 Gigawatts of Wind Energy Capacity

This study seeks to establish a comprehensive baseline of knowledge for the replacement and damage of main bearings in wind turbines. The purpose of this report is to provide a high-level summary of the data set, methodology, and results of this work. Full technical details and an extended analysis will be made available in a future publication. We collected data on main bearing replacements and reported damage from industrial partners based in Europe and the United States. In total, we obtained data for 167 wind power plants, with a combined capacity of 15.3 gigawatts (GW). Most of the data set was comprised of land-based, three-point mount, spherical roller bearings. Within this data set were 689 instances of main bearing replacement. Analysis was undertaken in two parts: first, a statistical analysis of the main bearing time-to-replacement data using survival analysis techniques; second, quantitative and qualitative analyses of the obtained damage information. Our results showed that 10% of a fixed main bearing population would be expected to have been replaced by 10.5 years. This is close to half of the 20-year design value. Fitted parametric distributions then indicated that by year 20, between 22% and 25% of main bearings are expected to have been replaced. Analysis of the damage reports revealed spalling to be the main type of damage listed. The additional presence of surface damage in the collected data indicates that at least part of the spalling cases are likely due to surface-initiated rolling contact fatigue. At this stage is not clear what proportion of spalling cases result from "wear induced", surface-initiated and subsurface-initiated rolling contact fatigue. While this work provides important insights into the current state of main bearing replacements and damage, many questions remain. An ongoing and expanding data collection and analysis effort focused on wind turbine main bearings is therefore recommended.

17 WIND ENERGY↗

Validation of a lightning protection system for a fusion-welded thermoplastic composite wind turbine blade tip

Fusion welding for thermoplastic composite wind turbine blades is being investigated as a replacement for adhesives in bond lines to reduce manufacturing time and cost and to promote ease of recyclability. Resistance welding uses an electrically conductive material, such as carbon fiber, embedded in the bond line to heat the joining surfaces and fuse them together under pressure. One main challenge with fusion joining for large wind blades is the ability to use this conductive heating element in the bond line while still protecting the blade from the catastrophic effects of a lightning strike. This paper outlines the design and manufacturing of a lightning protection system for a 5-m-long thermally welded blade tip. The outcomes of high voltage and high current lightning testing applied to the 5 m blade tip show that the proposed design was able to protect the fusion welded bond lines from significant lightning damage.

17 WIND ENERGY↗

Prognosis of Wind Turbine Gearbox Bearing Failures Using SCADA and Modeled Data

Predictive maintenance and condition monitoring systems for wind turbines have seen increased adoption to minimize downtime, reducing operation and maintenance costs. On today’s wind power plants, the integrated supervisory control and data acquisition (SCADA) system provides low- frequency operational data that can be leveraged to quantify a wind turbine’s health. The aim of this study is to utilize machine-learning techniques to predict axial cracking failures in wind turbine gearbox bearings up to 1 month ahead of time. The failures are assumed to have occurred when the investigated bearing was replaced. While current SCADA systems show the overall condition of a wind turbine, often they do not allow for the investigation of specific gearbox bearings’ health. To enrich bearing fault signatures, additional data are computed through physics-based models using gearbox design information. Based on SCADA data, modeled data, and bearing failure log data from an actual wind plant, the performances of different machine-learning models on unseen data are then evaluated using industry-standard metrics such as precision, recall, and F1 score. Results show the overall system performance enhancement in predicting bearing failure when modeled data are included with SCADA data. The reduction in terms of false alarms is about 50%, and improvement in terms of precision and F1 score is about 33% and 12% respectively, based on the best modeling case in this study.

49 EE - Wind and Water Power Program - Wind (EE-4W↗