Experimentally validated modeling of a turbo-compression cooling system for power plant waste heat recovery
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
This paper describes the use of xenon difluoride to clean deposits in the source housing, source turbo pump, and source turbo pump fore-line of ion implanters. Xenon difluoride has previously been shown to be effective in increasing the lifetime of the ion source{sup 1,2} and this paper presents an extension of the technology to other areas within the tool. Process by-products that are deposited in the source housing, turbo pump, and turbo pump fore-line can not only pose productivity issues, in the case of coatings on insulators, but can also be flammable and toxic in the case of deposits formed within the turbo pump and fore-line. The results presented in this paper detail the initial successful examples of using xenon difluoride to clean these deposits.ATMI has shown that xenon difluoride is capable of cleaning an insulator in an ion implanter. Typically during use an insulator will become increasingly coated with deposits that could lead to productivity problems. By introducing xenon difluoride into the source housing the insulator residues were effectively cleaned in-situ, thereby extending the maintenance interval and resulting in significant consumable savings.Similar deposits that form in the turbo pump and fore-line could not only lead to production problems due to turbo pump failure or fore-line build-up, but pose significant health risks during the ex-situ cleaning process. Through internal testing ATMI has shown that xenon difluoride is able to clean phosphorus and germanium deposits located within a turbo pump. Additionally, testing has demonstrated that the turbo pump fore-line can be cleaned in-situ without the need to remove these components, thereby virtually eliminating the possibility of fires. The cleaning reaction progress and by-products were monitored using FTIR spectrometry and thermocouples.In order to efficiently clean the source housing, turbo pump, and turbo pump fore-line xenon difluoride delivery must be optimized. This paper also details a hardware concept that maximizes xenon difluoride delivery and allows the clean to be done in a way that is viable for production ion implanters.
An experimental platform for cryogenic Helium gas bearing turbo-expanders is established at the Technical Institute of Physics and Chemistry, Chinese Academy of Sciences. This turbo-expander experimental platform is designed for performance testing and experimental research on Helium turbo-expanders with different sizes from the liquid hydrogen temperature to the room temperature region. A measurement and control system based on Siemens PLC S7-300 for this turbo-expander experimental platform is developed. Proper sensors are selected to measure such parameters as temperature, pressure, rotation speed and air flow rate. All the collected data to be processed are transformed and transmitted to S7-300 CPU. Siemens S7-300 series PLC CPU315-2PN/DP is as master station and two sets of ET200M DP remote expand I/O is as slave station. Profibus-DP field communication is established between master station and slave stations. The upper computer Human Machine Interface (HMI) is compiled using Siemens configuration software WinCC V6.2. The upper computer communicates with PLC by means of industrial Ethernet. Centralized monitoring and distributed control is achieved. Experimental results show that this measurement and control system has fulfilled the test requirement for the turbo-expander experimental platform.
The software team that develops Turbo FRMAC (TF) at Sandia National Labs has continued to look for technologies to add Cloud-enabling features to Turbo FRMAC. The Amazon AppStream service has now matured into a viable low-cost solution with quick turnaround potential to create a Cloud version of Turbo FRMAC. This service would allow both a Desktop and Cloud version of Turbo FRMAC to exist without duplicate efforts to support both instances. The only software needed to run is a modern Web Browser — no downloads and no installation necessary.
The Booster Accelerator uses Sargent Welch turbo pumps, back by roots blowers, to pump the magnet strings from atmosphere to ion pump starting pressure. In 2009, all of the Booster Correction magnets were upgraded to a larger correction magnet. This drove the need to redesign the turbo pump manifold. This new design incorporated a method to connect a different turbo molecular pump. The turbo pump chosen to test was the Oerlikon Leybold Turbovac 151 pump. This was based upon the previous success in the Tevatron, when used as a replacement for the 3120 Sargent Welch pump. The rated speed of the Leybold 151 is 145 l/s nitrogen. The rated speed of the Sargent Welch is 160 l/s nitrogen.
Southwest Research Institute® (SwRI®) has developed a novel, high-efficiency, supercritical carbon dioxide (sCO 2 ), hot gas turbo-expander optimized for the highly-transient, solar-powerplant, duty-cycle profile. This MW-scale sCO 2 turbo-expander design advances the state-of-theart of sCO 2 turbo-expanders from a current Technology Readiness Level (TRL) of three (initial, small-scale, laboratory, size testing) to a full TRL6 (MW-scale prototype demonstration). A secondary objective of this project was to optimize novel compact heat exchangers for sCO 2 applications to drastically reduce their manufacturing costs. Significant learning was achieved on how to design and fabricate a more cost effective, high performance recuperator, at the MWt capacity. The sCO 2 turbo-expander and novel sCO 2 heat exchanger have been tested in a 1- MWe sCO 2 test loop, fabricated to demonstrate component performance and the performance of the optimized sCO 2 Brayton cycle over a wide range of part load conditions and during transient operations representative of a typical Concentrating Solar Power (CSP) duty cycle. The scalable sCO 2 expander design and improved heat exchanger address and close two critical technology gaps required for an optimized CSP sCO 2 power plant and provide a major stepping stone on the pathway to achieving CSP power at $\$ $0.06/kW-hr Levelized Cost of Electricity (LCOE), increasing energy conversion efficiency to greater than 50% and reducing total power block cost to below $\$ $1,200/kW installed. Construction of the facility and testing has been completed. Test targets of 1,320°F, 27,000 rpm, and 3,500 psi were reached during separate tests. Overall, the turbine saw 37.5 hours of operation with many other hours of testing and troubleshooting all of the loop components. All the test data and troubleshooting is useful and applicable for future tests and operations with not only this loop but in any sCO2 application.
The Turbo FRMAC analysis tool is used to perform complex calculations to quickly evaluate radiological consequences and aid in decision making during an emergency response by assessing impacts to the public, workers, and the food supply. Turbo FRMAC calculations are based on methods established by the Federal Radiological Monitoring and Assessment Center (FRMAC). To be able to assess impacts, input data called transfer factors that describe radionuclide uptake by local plants and animals are required. During the code application exercises in late 2016, identifying, finding, and validating nonstandard transfer factors proved to be time consuming and diverted the teams’ activity away from other critical tasks. As a result, a task was undertaken to dramatically expand the list of available transfer factors (food and non-food) and incorporate these factors into Turbo FRMAC. This will ultimately result in improved efficiency of the assessment team to perform calculations during times when the FRMAC is activated and provide more defensible, vetted data from which to calculate results. As a result of these and subsequent exercises, transfer factors were needed for the following items: bell peppers, Christmas tree, deer, flowers, fresh cucumbers, tomatoes, grapefruit, lichens, mushrooms, oranges, snap beans, squash, strawberries, sugarcane for sugar and seed, sweet corn, tea, tobacco, tree bark, and watermelon. To expand the applicability of the information tables, generic transfer data were also provided for common categories and recommendations were made for expanding the list of chemicals based on chemical similarity. The data presented in this report were compiled from recent literature with most of the data encompassing the period from 2000 to 2018. The following radionuclides were targeted during the literature search: elements associated with reactor accidents or nuclear detonations (Sr 89/90, Cs 134/137, Ce 141/144, Ru 103/106, I 129/131/133, Pu 238/239, Am 241, Zr 95, and Nb 95) and elements associated with industrial accidents or dirty bombs (Ir 192 and Co 60). Data from other elements were evaluated if they were identified during the literature search. In addition, reports were evaluated that were recommended by the research consultants. For each plant or animal transfer factor, the goal was to determine the geometric mean, the geometric standard deviation, the minimum, the maximum, and the number of measurements used. If only one measurement was available that was presented as the mean. Concentration ratios with large geometric standard deviations (GSDs) were generally the result of a paucity of measurements or a few disparate measurements. Measurement disparity was observed for data from different soil types. The geometric mean (GM) is a good reference value for planning and responses purposes, but the location-specific concentrations are unlikely to be similar to the model results. Recommendations for further work include: segregating the data to reflect the influence of soil type, developing approaches to incorporate animal data based on aggregated transfer measurements, and including data for foliar deposition on plants.
The Turbo FRMAC analysis tool performs complex calculations to quickly evaluate radiological hazards during an emergency response by assessing impacts to the public, workers, and the food supply. Turbo FRMAC can be used to evaluate the hazard from a wide variety of radiological incidents. Turbo FRMAC calculations are based on methods established by the Federal Radiological Monitoring and Assessment (FRMAC). Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. SAND2021-10713 O
The Federal Radiological Monitoring and Assessment Center (FRMAC) has two major assets it uses to perform it responsibilities for responding to a radiological emergency. These are the National Atmospheric Release Advisory Capability (NARAC) and Turbo FRMAC. Recently NARAC updated their deposition model to the state of the art Petroff and Zhang model leading to a significant discrepancy between these two assets in regards to deposition modeling. This report describes the investigation into an appropriate deposition model for Turbo FRMAC to bring the two assets back into line. The ultimate conclusion is that Petroff and Zhang is too complicated for Turbo FRMAC, but the model of Feng is not and is equal to Petroff and Zhang in predictive capability.
An internal combustion engine incorporating a turbo-generator and one or more variably activated exhaust valves. The exhaust valves are adapted to variably release exhaust gases from a combustion cylinder during a combustion cycle to an exhaust system. The turbo-generator is adapted to receive exhaust gases from the exhaust system and rotationally harness energy therefrom to produce electrical power. A controller is adapted to command the exhaust valve to variably open in response to a desired output for the turbo-generator.
A turbo compounding system may include a turbo generator having a switched reluctance machine having at least one pole-matched rotor and stator pair, a single phase inverter coupled to the turbo generator and further coupled to a direct current link, an inverter coupled to the direct current link, a motor generator coupled to the inverter.
Modern diesel engines used in light-duty transportation applications have peak brake thermal efficiencies in the range of 40-42% for high-load operation with substantially lower efficiencies at realistic road-load conditions. Thermodynamic energy and exergy analysis reveals that the largest losses from these engines are due to combustion irreversibility and heat loss to the coolant, through the exhaust, and by direct convection and radiation to the environment. Substantial improvement in overall engine efficiency requires reducing or recovering these losses. Unfortunately, much of the heat transfer either occurs at relatively low temperatures resulting in large entropy generation (such as in the air-charge cooler), is transferred to low-exergy flow streams (such as the oil and engine coolant), or is radiated or convected directly to the environment. While there are significant opportunities for recovery from the exhaust and EGR cooler for heavy-duty applications, achieving similar benefits for light-duty applications is complicated by transient, low-load operation at typical driving conditions and competition with the turbocharger and aftertreatment system for the limited thermal resources. We have developed an organic Rankine cycle model using GT-Suite to investigate the potential for efficiency improvement through waste-heat recovery from the exhaust and EGR cooler of a light-duty diesel engine. The model is used to examine the effects of efficiency-improvement strategies such as cylinder deactivation, use of advanced materials and improved insulation to limit ambient heat loss, and turbo-compounding on the steady-state performance of the ORC system and the availability of thermal energy for downstream aftertreatment systems. Results from transient drive-cycle simulations are also presented, and we discuss strategies to address operational difficulties associated with transient drive cycles and balancing the thermal requirements of waste-heat recovery, turbocharging or turbo-compounding, and exhaust aftertreatment.
This report documents the findings of an assessment of the Turbo FRMAC software's ability to implement International Atomic Energy Agency (IAEA) guidance for calculating Operational Intervention Levels (OIL) 1 & 2 for nuclear and radiological emergencies. The IAEA OIL and U.S. Federal Radiological Monitoring and Assessment Center (FRMAC) Derived Response Level methodology and implementation in respective tools were compared, as demonstrated through benchmarking activities for a nuclear power plant source term and potential radionuclides of concern for radiological dispersal devices. This comparison revealed some shortcomings in Turbo FRMACs ability to perform IAEA OIL calculations and resulted in recommended software modifications to be considered for future development.
Objectives: Automate the labor-intensive process of generating Analytical Action Levels (AALs) in Turbo FRMAC to shorten the timeline for planning sampling campaigns and sample analysis during a response. Make the tool output results in a format that is easily imported to RadResponder as a Mixture for use in Analysis Request Forms. Deliver training to EPA on using this new tool in Turbo FRMAC (Delayed due to COVID.
This report documents the findings of an assessment of the Turbo FRMAC© software’s ability to implement International Atomic Energy Agency (IAEA) guidance for calculating operational intervention levels (OIL) for nuclear and radiological emergencies. This assessment is a continuation of previous work that considered IAEA OIL1 and OIL2 for evacuation and relocation protective actions. The IAEA OIL and U.S. Federal Radiological Monitoring and Assessment Center (FRMAC) derived response and intervention level methodologies were compared for ingestion and skin and thyroid monitoring pathways. This comparison revealed significant differences in IAEA versus FRMAC handling of these pathways, which precluded an assessment of Turbo FRMAC’s ability to implement the IAEA approach.
A collection of solid body modeling tools for 2D sketched, 2D axisymmetric, and 3D revolved models. It also contains general purpose meshing and image generation utilities appropriate for any model, not just those created with this package. Implemented for Abaqus and Cubit as backend modeling and meshing software. Orginal implementation targeted Abaqus so most options and descriptions use Abaqus modeling concepts and language. Turbo-Turtle makes a best effort to maintain common behaviors and features across each third-party software’s modeling concepts. As much as possible, the work for each subcommand is performed in Python 3 to minimize solution approach duplication in third-party tools. The third-party scripting interface is only accessed when creating the final tool specific objects and output. The tools contained in this project can be expanded to drive other meshing utilities in the future, as needed by the user community. This project derives its name from the origins as a sphere partitioning utility following the turtle shell (or soccer ball) pattern.s.
The present application provides an aerodynamic seal assembly for use with a turbo-machine. The aerodynamic seal assembly may include a number of springs, a shoe connected to the springs, and a secondary seal positioned about the springs and the shoe.
The Turbo FRMAC (TF) software program is the software implementation of the science and methodologies utilized in the Federal Radiological Monitoring and Assessment Center (FRMAC). The software automates the calculations described in volumes 1 of "The Federal Manual for Assessing Environmental Data during a Radiological Emergency" (2015 version). In the event of the intentional or accidental release of radioactive material, the software is used to guide and govern the response of the Federal, State, Local, and Tribal governments. The manual, upon which the software is based, is unclassified and freely available on the Internet.