Search NASA⌕ Search

SEARCH · Search NASA

Results for “Type 5 Wind”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Type 5 Wind Turbine Technology: How Synchronised, Synchronous Generation Avoids Uncertainties About Inverter Interoperability under IEEE 2800:2022

Degradation of system strength because of inverter-based resources (IBRs) is a major concern facing the zero-carbon transition. A new standard released this year, IEEE Standard 2800, attempts to codify the relationship between IBRs and the Transmission System Operator (TSO). It is apparent from IEEE 2800:2022 that there remain fundamental problems with quantifying whether source impedance (the measure of "system strength" with which the standard is concerned) will present a problem for allowing an IBR to connect. This is "because of complex interdependencies between IBR and power system characteristics". So developers are increasingly required to adopt mitigation options such as adding synchronous condensers or curtailing IBRs. A proven Type 5 (synchronous) wind turbine exists and has been running at 0.5 MW scale in a 46 MW wind farm in New Zealand since 2006 and eight turbines in Scotland since 2013. The US National Renewable Energy Laboratory (NREL) is conducting a study of the impacts on grid reliability, stability, and resilience of Type 5 wind turbines. The project has both simulation and testing tasks and will result in proposing a variable generation solution that will help system operators and utilities address all reliability and most resilience challenges in the evolving grid.

grid stability↗

Inter-Area Oscillation Damping with Type-5 Wind Power Plant

This paper investigates the potential of using brushless excitation (BLE) for not only riding through the fault but also to damp inter-area power oscillation with the help of a synchronous generator (SG) used in Type 5 Wind Power Plant (WPP). In BLE, an auxiliary synchronous generator (ASG) behaving like an exciter is coupled and driven by the rotor of the main SG. The BLE's field current's ASG is fed by two separate loops of the automatic voltage regulator (AVR) and power system stabilizer (PSS). The AVR system implements a control loop to regulate the generator terminal voltage, VT. For the PSS, the kinetic energy of the wind turbine is utilized according to the estimated rotational speed of the synchronous generator shaft of the SG. It may mitigate the necessity of any curtailment of active power for damping. The effectiveness of the proposed control scheme is verified with a three-phase short circuit fault in a two-area power system.

brushless↗

Inter-Area Oscillation Damping with Type-5 Wind Power Plant: Preprint

This paper investigates the potential of using brushless excitation (BLE) for not only riding through the fault but also to damp inter-area power oscillation with the help of a synchronous generator (SG) used in Type 5 Wind Power Plant (WPP). In BLE, an auxiliary synchronous generator (ASG) behaving like an exciter is coupled and driven by the rotor of the main SG. The BLE's field current's ASG is fed by two separate loops of the automatic voltage regulator (AVR) and Power System Stabilizer (PSS). The AVR system implements a control loop to regulate the generator terminal voltage, VT. For the PSS, the kinetic energy of the wind turbine is utilized according to the estimated rotational speed of the synchronous generator shaft of the SG. It mitigates the necessity of any curtailment of active power for damping. The effectiveness of the proposed control scheme is verified with a three-phase short circuit fault in a two-area power system.

brushless↗

High-Fidelity Modeling of a Type-5 Wind Turbine Gearbox (Intern Poster) [Poster]

Type-5 wind turbines are unique in their use of a permanent magnet synchronous generator, as well as their use of a hydraulic torque converter. This architecture presents an opportunity to provide steady and grid-ready energy without the need for a power converter. With infrastructure continuity and reliability being an important topic amongst renewable energies, researchers have been prompted to further investigate the benefits of type-5 turbines’ unique electromechanical configuration on stable electricity generation. Researchers involved in the WindSG project, SG standing for synchronous generator, are aiming to model a type-5 turbine using Real Time Digital Simulation (RTDS) to evaluate its efficacy in the grid. RSCAD, the software run on the RTDS, comes pre-loaded with electrical and electromechanical components to help simulate electrical generation and grid conditions. However, within this repertoire there is a lack of a component to represent a gearbox with high-fidelity. Within RSCAD’s case studies, the gearbox is often represented simply by a gear ratio value. This presented the task of developing a high-fidelity gearbox model in RSCAD for use in the larger RTDS type-5 wind turbine model. This poster describes a method of developing a lumped parameter mathematical model to represent a planetary-parallel-parallel gearbox in RSCAD for use in RTDS.

17 WIND ENERGY↗

Operating Wind Turbine as Synchronous Generator: Modeling and Power-Hardware-in-the-Loop Demonstration

Grid-forming (GFM) control of Type 3 and Type 4 wind turbine generators (WTGs) has attracted substantial attention in power systems research; however, the limited overcurrent capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also referred to as a Type 5 WTG, offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high integration levels of renewable generation. A Type 5 WTG interfaces with the electric grid via a synchronous generator driven by a variable speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation, and the generator shaft remains synchronous to the grid. This paper develops and tests a high-fidelity model of a Type 5 WTG in a power-hardware-in-the-loop testing environment, and it presents its operation characteristics under different grid contingencies. The power-hardware-in-the-loop demonstration shows that a Type 5 WTG inherently behaves as a GFM unit and can obtain similar performance in terms of power response, wind rotor dynamics, and stability enhancement compared to a Type 3 WTG in GFM control mode. Furthermore, the paper provides further insight into how Type 5 WTGs can support the smooth transition to power systems with high integration levels of inverter-based resources.

17 - WIND ENERGY↗

One-to-one aeroservoelastic validation of operational loads and performance of a 2.8 MW wind turbine model in OpenFAST

Abstract. This article presents a validation study of the popular aeroservoelastic code suite OpenFAST leveraging weeks of measurements obtained during normal operation of a 2.8 MW land-based wind turbine. Measured wind conditions were used to generate one-to-one turbulent flow fields (i.e., comparing simulation to measurement in 10 min increments, or bins) through unconstrained and constrained assimilation methods using the kinematic turbulence generators TurbSim and PyConTurb. A total of 253 bins of 10 min of normal turbine operation were selected for analysis, and a statistical comparison in terms of performance and loads is presented. We show that successful validation of the model was not strongly dependent on the type of inflow assimilation method used for mean quantities of interest, which had median modeling errors per wind-speed interval generally within 5 %–10 % of the measurement. The type of inflow assimilation method did have a larger effect on the fatigue predictions for blade-root flapwise and tower-base fore–aft quantities, which surprisingly saw larger errors from the assumed higher-fidelity assimilation methods. Avenues for further work are discussed and include possible improvements to the aerodynamic, structural, and controller modeling that may offer insight on the origin of the up to ∼ 40 % median overprediction of fatigue for these quantities.

17 WIND ENERGY↗

Sequence Impedance Measurement of Utility-Scale Wind Turbines and Inverters – Reference Frame, Frequency Coupling, and MIMO/SISO Forms

Sequence impedance responses with or without considering frequency coupling in both MIMO and SISO forms are increasingly used for the stability analysis of three-phase power electronic systems; however, many aspects of sequence impedance measurement are not fully explored. It is not clear if the sequence impedance has a reference frame similar to the dq impedance. If so, the role of the grid voltage angle estimation in aligning the sequence impedance reference frame has not been discussed. Additionally, existing methods for measuring the sequence impedance with frequency coupling are complicated, are not feasible for large wind turbines and inverters, and provide the sequence impedance responses in only either MIMO or SISO form. This paper presents a sequence impedance measurement method that considers the frequency coupling, performs reference frame alignment, demonstrates the impact of the grid voltage angle estimation, and obtains the sequence impedance response in both MIMO and SISO forms. This paper demonstrates the proposed method and practical problems associated with the sequence impedance measurement of utility-scale wind turbines and inverters on a 1.9-MW Type III wind turbine and a 2.2-MVA inverter using an impedance measurement system built around a 7-MW/13.8-kV grid simulator and a 5-MW dynamometer.

17 WIND ENERGY↗

Enhancing carbon storage through proactively managing fire-prone coniferous mountain forests

Mountain ecosystems typically serve as carbon (C) sinks. However, studies also suggest that they could be C sources due to climate warming, drought and insect-related mortality, wildfires, and management actions. We applied the Lund-Potsdam-Jena General Ecosystem Simulator (LPJ-GUESS), a process-based dynamic vegetation-ecosystem model, to investigate the role of ecosystem management in C storage under Mediterranean climate over the 21 st century. We modified LPJ-GUESS to include implementing mechanical thinning by vegetation size classes, components, and types along with a new mechanistic fire-occurrence model that accounts for wind speed and lightning ignition. Simulations show that mechanical thinning or prescribed fire performed 5-20 years in advance of a high-severity wildfire reduced direct wildfire C emissions by 38-66 %. Our results also show that long-term management actions repeated every 5-20 years, including thinning relatively small trees (diameters up to 7 inches or ∼178 mm), can maintain stable C levels in the forest and lower dead-fuel amounts. We found that, although prescribed fire mitigated wildfire severity, ecosystem C storage from reduced wildfire emissions can be outweighed by the added emissions from the prescribed fire themselves. Thinning plus removing and sequestering the thinned biomass can ensure that forests act as net C sinks through the end of the 21 st century. However, addition of prescribed fire is needed to reduce understory and lower the projected extent of high-severity wildfire. Achieving the competing goals of reducing wildfire and making the Sierra Nevada long-term C sink can be advanced through carefully coordinated thinning, sequestration of thinned biomass, and prescribed fire.

Climate solutions↗

Annual report for DOE VTO

Carbon fiber (CF)/polymer composites are a transformative class of high-performance, lightweight material, where high aspect-ratio CFs reinforce a polymer matrix and exceed the strength of steel alloys at a fraction of the density. Despite the advantages of such a class of material, the broader implementation of CF composites in a range of automotive, aerospace, and energy applications is hindered by limitations of current manufacturing methods. These current techniques (e.g., hand lay-up, wet filament winding) are costly and impose severe limitations on fiber placement, orientation, and angle, and thus a composite’s ultimate properties. Today’s CF composites are expensive to manufacture, limited in form factor, and utilize costly and sub-optimal continuous filament CF. Advanced additive manufacturing (AM) processes, combined with computational design optimization and new approaches to resin development, offer alternative design and manufacturing paradigms that have the realistic potential to lift these constraints. Such integrated AM approaches could thus help to realize the full potential of CF composite materials. One relevant application of CF composite materials where manufacturing constraints limit the cost-benefit ratio is in the manufacture of high-performance composite pressure vessels for onboard compressed natural gas (CNG) storage. Current CNG storage vessels (Types 3–5) are made from load-bearing filament-wound carbon-fiber composite and are ~3.5 times as expensive as an all-metallic Type-1 vessel. This cost is invariably tied to the complex and labor-intensive nature of conventional filament winding processes and the large volumes of expensive high tensile-strength CF tow feedstock required in manufacture. Our proposed approach to CNG storage vessel manufacture is based on a combination of AM technologies for CF composite printing and design optimization tools that were pioneered at Lawrence Livermore National Laboratory (LLNL), with advances in resin/composite formulation enabled by chemical and nano-material modification. Through the successful development of this technology, LLNL seeks to demonstrate the capability for advanced CNG storage vessel manufacture at reduced cost with no reduction in performance versus the most advanced, extant Type-5 designs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Large eddy simulations of offshore wind turbine wakes for two floating platform types

The growing prospect for large farms of floating offshore wind turbines requires a better understanding of wake effects for floating turbines. In this work, large eddy simulations with an actuator line model are used to study the wake of the NREL 5 MW reference turbine mounted on the OC3-UMaine spar and OC4-DeepCwind semi-submersible platforms. The simulations are carried out in the Simulator fOr Wind Farm Applications (SOWFA) coupled with OpenFAST for the platform and turbine motion. The wake location, deficit, and turbulence levels are compared for the two floating platforms and equivalent fixed-turbine cases. The effects of neutral versus stable atmospheric conditions are also compared. Most notably, floating-turbine wakes are deflected upwards compared to fixed-turbine wakes, because of mean platform pitch. The spar wake deflects upwards more than the semi-submersible, while the stable atmosphere increases this vertical deflection compared to the neutral. The time-varying rotor motions do not significantly affect the mid-to-far wake, though the stable atmosphere shows larger fixed-floating differences in horizontal wake fluctuations.

17 WIND ENERGY↗

Hybrid model to evaluate the frequency-dependent leakage inductance of partially-filled transformers

The leakage inductance of a transformer designed for a power electronic converter can drop significantly as the switching frequency is increased due to skin and proximity effects. Although the magnetic image method-based double-2-D model can predict the low-frequency leakage inductance of a partially-filled transformer with sufficient accuracy, it is inherently a frequency-independent model. While Dowell’s 1-D model uses frequency-dependent relations to account for both skin and proximity effects, its accuracy is severely affected by the assumed winding geometry. In this paper, a semianalytical hybrid model is proposed that uses superposition to combine a modified Dowell’s model with the double-2-D model to predict the true leakage inductance of partially-filled transformers at any given frequency. All three conductor types—round, foil, and litz wire—are modeled and analyzed. The quasi-2-D model is further investigated on a variable inductance transformer (VIT) whose winding geometry can be modified mechanically to vary its leakage inductance. With less than 5 % error throughout, the semi-analytically evaluated leakage inductances are in excellent agreement with the finite element method (FEM) simulated and experimentally measured leakage inductances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dust pollution in China affected by different spatial and temporal types of El Niño

Dust is an important aerosol affecting air quality in China in the winter and spring seasons. Dust in China is potentially influenced by the interannual climate variability associated with El Niño. Here, the impacts of El Niño with different temporal and spatial types on dust pollution in boreal winter and spring in China and the potential mechanisms are investigated using a state-of-the-art Earth system model (E3SMv1). We find that the eastern Pacific (EP) and central Pacific (CP) El Niño both increase wintertime dust concentrations by 5–50 µg m –3 over central-eastern China. Due to a stronger wind and lower relative humidity, which favor dust emissions near sources, and a strengthened northwesterly and reduced precipitation, which are conducive to dust transport, dust concentrations during the CP El Niño are 5–20 µg m –3 higher in northern China than during the EP El Niño, although the changes are mostly insignificant. El Niño with a short duration (SD) increases boreal winter dust concentrations by 20–100 µg m –3 over northern China relative to the climatological mean, while there is a decrease of 5–50 µg m –3 during the long-duration (LD) El Niño, which is also related to the El Niño-induced changes in atmospheric circulation, precipitation, and relative humidity. In the following spring season, all types of El Niño events enhance dust over northern China, but only the increase during the LD El Niño is statistically significant, suggesting that the weaker intensity but longer duration of the LD El Niño events can significantly affect spring dust in China. Our results contribute to the current knowledge of the influence of El Niño on dust pollution, which has profound implications for air pollution control and dust storm prediction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transition of Large-Scale Environmental Conditions and Characteristics of Four Rainfall Types Observed by S-PolKa During the MJO-1 Active Phase of DYNAMO/CINDY/AMIE

Analyses of National Center for Atmospheric Research (NCAR) S-PolKa dual-polarization radar data and ERA5 reanalysis fields indicate gradual changes in convection characteristics and large-scale environmental conditions during a central Indian Ocean Madden-Julian Oscillation (MJO) event observed by the DYNAMO/CINDY/AMIE field campaigns in late October 2011 (MJO-1). Examination of four rainfall types (isolated convective cores, convective, mixed, and stratiform) reveals a transition of convection characteristics (i.e., areal coverage and depth) between distinct 5-day environmental periods at the beginning and end of this ~2-week MJO active phase. A shift toward less frequent rainfall covering less of the radar domain for all four rainfall types occurs when large-scale lower-tropospheric dry air advects into the region with the westerly wind burst (WWB). Drier and warmer lower-free-tropospheric conditions associated with the WWB contribute to increased large-scale surface-based convective inhibition (CIN), surface-based convective available potential energy (CAPE), and cloud base heights. A thermodynamic budget analysis indicates reduced surface heat fluxes contribute to the increased surface-based CAPE. Greater CAPE at the end of MJO-1 coincides with deeper 50-dBZ convective echoes, while decreased 10-dBZ depth for all rainfall types corresponds in time with WWB-related dry-air advection. Increased (decreased) reflectivity values in the lower-level vertical reflectivity distribution of convective (stratiform) precipitation indicate increased (decreased) convective (stratiform) intensities when the WWB is present. The opposite depth changes for convective echoes and opposite shifts in convective and stratiform precipitation intensities underscore how the WWB can have differing impacts at different reflectivity thresholds and stages of the deep convection lifecycle.

54 ENVIRONMENTAL SCIENCES↗

Floating platform effects on power generation in spar and semisubmersible wind turbines

The design and financing of commercial-scale floating offshore wind projects require a better understanding of how power generation differs between newer floating turbines and well-established fixed-bottom turbines. In floating turbines, platform mobility causes additional rotor motion that can change the time-averaged power generation. In this work, OpenFAST simulations examine the power generated by the National Renewable Energy Laboratory's 5-MW reference turbine mounted on the OC3-UMaine spar and OC4-DeepCWind semisubmersible floating platforms, subjected to extreme irregular waves and below-rated turbulent inflow wind from large-eddy simulations of a neutral atmospheric boundary layer. For these below-rated conditions, average power generation in floating turbines is most affected by two types of turbine displacements: an average rotor pitch angle that reduces power, caused by platform pitch; and rotor motion upwind-downwind that increases power, caused by platform surge and pitch. The relative balance between these two effects determines whether a floating platform causes power gains or losses compared to a fixed-bottom turbine; for example, the spar creates modest (3.1%–4.5%) power gains, whereas the semisubmersible creates insignificant (0.1%–0.2%) power gains for the simulated conditions. Furthermore, platform surge and pitch motions must be analyzed concurrently to fully capture power generation in floating turbines, which is not yet universal practice. Finally, a simple analytical model for predicting average power in floating turbines under below-rated wind speeds is proposed, incorporating effects from both the time-averaged pitch displacement and the dynamic upwind-downwind displacements.

17 WIND ENERGY↗

Performance of Windows in Walls With Continuous Insulation

Window openings in walls are a significant contributor to poor thermal performance because of thermal bridging through the framing members (e.g., studs, joists, plates, bracing) and because windows lack the thermal properties of insulation. Window installation guidance for walls with continuous insulation (CI) is critical for continued market growth of this energy efficiency technology. This research project offers window manufacturers a starting point and a potential path toward developing installation instructions for windows over CI. The objectives of the research include evaluating the common method for installing windows in walls with CI, as well as establishing acceptance criteria for evaluating the performance of windows installed in walls with and without CI. The research measures: 1. The performance characteristics (e.g., water management, structural integrity) of windows in walls without CI. 2. The performance of different thicknesses and types of CI used in walls. 3. The performance of different types of window assemblies (e.g., double-hung windows, mulled double-hung windows, mulled casement windows, and slider windows) installed over CI. 4. The performance of window flange types (e.g., rigid mounting and less robust flanges) installed over CI. 5. Installing windows over CI using baseline installation instructions versus window manufacturer installation instructions. The project’s sequential testing protocol consists of the following: • A water penetration resistance testing adapted from two ASTM standards: E331 (uniform static air pressure in four steps) and E547 (cyclic static air pressure) • A temperature cycling adapted from ASTM E2264 Method B (convective hot air) • A service condition wind loading test adapted from ASTM E330 • A six-month vertical displacement observation phase prior to the structural performance testing • A final water penetration resistance test after vertical displacement observation • A structural performance test adapted from ASTM E330. Key research findings include: • The criterion for passing a water penetration resistance test is that there is no water overflowing at the interior face of the studs. If there is any bubbling or slight pooling of water at the sill, then it must recede after the pressure is removed. Excessive leakage and/or water leaking to the interior face of the framing around the window constitutes a failure. • All single double-hung windows installed directly to lumber or over oriented strand board passed all test protocols. • For most wall specimens, the test results showed that the use of foam sheathing did not affect the performance of the window for water leakage. • All wall specimens underwent temperature cycling. The results indicated that temperature cycling had little to no effect on windows installed over foam sheathing. • For wall specimens that underwent six-month vertical displacement monitoring, the results showed that windows installed over foam sheathing do not sag over time. • The single-hung and double-hung windows installed using window manufacturer installation instructions passed the structural performance test, compared to failures observed in windows that were installed using generic installation instructions. The generic and manufacturer installation methods differed on the following construction details: type of fasteners, fastening patterns on the flanges, and window shimming details. • Additional testing is required to determine methods to improve structural pressure performance of slider windows. Potential solutions that would require additional testing may include fastener spacing, different types of fasteners, masonry window clips, construction adhesive, foam sealant, stronger window flange material, and/or straps.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radio Morphology of Red Geysers

We present 150 MHz, 1.4 GHz, and 3 GHz radio imaging (LoTSS, FIRST, and VLASS) and spatially resolved ionized gas characteristics (SDSS IV-MaNGA) for 140 local ($z$ < 0.1) early-type red geyser galaxies. These galaxies have a low star formation activity (with a star formation rate, SFR, ~ 0.01 $M$ ⊙ yr -1 ) but show unique extended patterns in spatially resolved emission-line maps that have been interpreted as large-scale ionized winds driven by active galactic nuclei (AGN). In this work, we confirm that red geysers host low-luminosity radio sources ($L$ 1.4GHz ~ 10 22 $WHz$ -1 ). Out of 42 radio-detected red geysers, 32 are spatially resolved in LoTSS and FIRST, with radio sizes varying between ~5–25 kpc. Three sources have radio sizes exceeding 40 kpc. A majority display a compact radio morphology and are consistent with either low-power compact radio sources (FR0 galaxies) or radio-quiet quasars. They may be powered by small-scale AGN-driven jets that remain unresolved at the current 5'' resolution of radio data. The extended radio sources, not belonging to the "compact" morphological class, exhibit steeper spectra with a median spectral index of -0.67, indicating the dominance of lobed components. Furthermore, the red geysers hosting extended radio sources also have the lowest specific SFRs, suggesting they either have a greater impact on the surrounding interstellar medium or are found in more massive halos on average. The degree of alignment of the ionized wind cone and the extended radio features are either 0° or 90°, indicating possible interaction between the interstellar medium and the central radio AGN.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermodynamic Model and Initial Experimental Investigation of Air Dehumidification through Electrically Charged Vapor Capturing Electrostatic Droplets

The removal of water vapor from the air to reduce relative humidity is a well known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation with the goal to reduce the energy consumption associated with dehumidification. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. In this thesis, a broad theoretical investigation to study the electrostatically enhanced condensation processes was carried out. These processes consist of the use of highly charged particles, preferably highly charged water droplets to attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. The electrical charge promotes the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation on curved surfaces and, consequently, the equilibrium between evaporation and condensation is shifted towards condensation. This investigation resulted in the development of a thermodynamics model, which was able to predict an effective size range of the charged droplets for optimal dehumidification, under ideal conditions. The range resulted in about 2 to 4 m in diameter, while the electrical charge was kept to the maximum limit predicted by the Rayleigh model. A sensitivity analysis on the variation of the size and the charge of the charged droplets was also performed. In terms of dehumidification rates, when six electrospray heads, i.e. the maximum number of heads tested in the experimental campaign, were considered, the model predicted very limited rates, way lower than the target of this research, i.e. a dehumidification rate in terms of relative humidity of 5 % with an air flow rate of 5 cfm. While ways to increase this rate existed, their implementation proved difficult for this initial investigation. According to the requirements predicted by the model, the use of electrosprays appeared the most suitable solution for the production of small but highly charged droplets. The electrospray features and operational modes were studied in detail and an electrospray assembly was designed to be tested in this initial experimental investigation. For this initial investigation, an experimental system was designed and built to validate the thermodynamics model and with the goal to achieve a dehumidification rate of 5 % in terms of relative humidity with an air flow rate of 5 cfm. The experimental system consisted of a wind tunnel test apparatus, dew point sensors, thermocouples for temperature measurements, pressure sensors and other devices. The experimental system was equipped with a computerized data acquisition and storage system. The system was suitable to evaluate the air water content differential before and after the test section where the electrospray heads were installed. The air water content differential was evaluated in terms of the ∆ω/ω_1 ratio, to eliminate the dependence on the dry bulb temperature along the test apparatus. This work presented initial experimental data for electrostatically enhanced dehumidification processes. Working parameters, such as air and water flow rates, high voltage potentials and polarity, deionized water types with different electrical conductivity, were varied to find the best combination for an improved dehumidification. With the set up used and the conditions considered, it was never possible to achieve a 5 % dehumidification rate with 5 cfm. In general, the dehumidification rate was always limited and lower than 1 % for all the air flow rates considered and mainly within the uncertainty of the dew point sensors. These results confirmed the already limited predictions of the thermodynamics model, for ideal conditions and the interesting and promising results obtained in some experimental investigations available in the open literature were not achievable in this thesis. The more probable reasons were the higher air flow rates considered and the complete absence of the use of cooling power, which was mainly implemented to facilitate the vapor condensation.

Morcelli, Stefano↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis – Simulated Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wind turbine. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen . While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the simulated wind energy profiles, NLR used OpenFAST to simulate a 3.4-MW International Energy Agency (IEA) reference wind turbine. The hour-long wind energy profiles varied over wind turbulence intensity (Class A or Class C) and average wind speed (5, 7, or 9 m/s). To match the power limits of the 1.25-MW electrolyzer and 3.4-MW IEA wind turbine most effectively and to maximize the efficiency of hydrogen production at a given average wind speed, the profiles were sometimes scaled by two times. This means that, in some cases, the experimental setup assumed two 1.25-MW electrolyzers were coupled with the wind turbine, representing a total maximum electrolysis load of 2.5 MW. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}-{average wind speed}-{turbulence class}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “windIEA3.4-5ms-C_2-400.zip” represents the hour-long experiment using the IEA 3.4-MW turbine, subjected to an average wind speed of 5 m/s and Class C wind turbulence, and connected to two 1.25-MW electrolyzers with the power supply set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wind turbine power. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis .

08 HYDROGEN↗