Search NASA⌕ Search

SEARCH · Search NASA

Results for “UHV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Thoughts on the past, present and future of UHV surface chemistry and the birth of Single-Atom Alloys

Throughout its relatively short lifetime, ultra-high vacuum (UHV) surface chemistry has progressed quickly. In the 1960's, pioneers like Ertl and Somorjai started the field using single crystals and gained significant insight into catalytic processes by relating surface structure to reactivity. The more recent proliferation of scanning probes has significantly increased the power of the single crystal approach by enabling the atomic-scale structure of active sites to be correlated with their reactivity. In this perspective we briefly discuss how the field developed, identify some challenges, and highlight Single-Atom Alloys (SAAs), a new class of heterogeneous catalyst that was developed from a fundamental surface science approach. However, despite recent successes, funding for fundamental surface science has declined. Academic hires in the discipline are also declining in part due to the start-up costs. We make the case that fundamental UHV surface chemistry is still too young a field to be in recession.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deployable UHV Pump

This project presents an external motorized actuation system for a deployable ultra-high vacuum (UHV) pump, enabling internal motion without compromising vacuum conditions. All active components remain external due to environmental and space constraints. A motor-driven mechanical feedthrough transfers motion into the pump, supported by a modular, adjustable mounting system that maintains alignment and integrates with existing hardware. CAD modeling and iterative design were used to refine geometry and ensure proper fit. The final design reliably transfers motion while maintaining alignment and structural integrity. Its adjustability improves installation and maintenance, demonstrating a practical solution for actuation in UHV systems.

Remington, Austin [Northern Illinois U.]↗

Examining Perceptual Luminance Uniformity of Simulated Luminaire Patterns

Luminaire luminance uniformity is an important aspect that can affect perceived lighting quality, discomfort glare, and efficacy. While several metrics have been proposed to characterize luminance uniformity, previous studies have shown that current metrics such as Max:Min or Avg:Min luminance ratios can be insensitive to important differences in luminance gradient that may affect perceived uniformity. In an attempt to resolve this issue, previous studies incorporated a contrast sensitivity function for the human eye based on spatial frequency, such as in the UHVS metric; however, this metric has not been comprehensively studied in relation to perceived uniformity ratings. The study presented in this paper aimed to examine the relationship between the UHVS metric and perceived uniformity ratings. Specifically, the study used a web-based questionnaire that presented simulated luminance patterns and asked participants to assess uniformity using a two-alternative forced-choice procedure. Responses were collected and analyzed from 94 participants. The results showed a significant correlation and relationship between the UHVS metric and perceived uniformity. However, comparisons between patterns that had similar UHVS and between patterns that had larger differences in UHVS did not yield consistent results. These results suggest that the UHVS metric might be used for general guidance but may warrant further studies to better understand its sensitivity and improve its alignment with perceived uniformity ratings.

Abboushi, Belal K.↗

A modular ultra-high vacuum millikelvin scanning tunneling microscope

We describe the design, construction, and performance of an ultra-high vacuum (UHV) scanning tunneling microscope (STM) capable of imaging at dilution-refrigerator temperatures and equipped with a vector magnet. The primary objective of our design is to achieve a high level of modularity by partitioning the STM system into a set of easily separable, interchangeable components. This naturally segregates the UHV needs of STM instrumentation from the typically non-UHV construction of a dilution refrigerator, facilitating the usage of non-UHV materials while maintaining a fully bakeable UHV chamber that houses the STM. Here, the modular design also permits speedy removal of the microscope head from the rest of the system, allowing for repairs, modifications, and even replacement of the entire microscope head to be made at any time without warming the cryostat or compromising the vacuum. Without using cryogenic filters, we measured an electron temperature of 184 mK on a superconducting Al(100) single crystal.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The stability of Cl-, Br-, and I-passivated Si(100)-(2 × 1) in ambient environments for atomically-precise pattern preservation

Abstract Atomic precision advanced manufacturing (APAM) leverages the highly reactive nature of Si dangling bonds relative to H- or Cl-passivated Si to selectively adsorb precursor molecules into lithographically defined areas with sub-nanometer resolution. Due to the high reactivity of dangling bonds, this process is confined to ultra-high vacuum (UHV) environments, which currently limits its commercialization and broad-based appeal. In this work, we explore the use of halogen adatoms to preserve APAM-derived lithographic patterns outside of UHV to enable facile transfer into real-world commercial processes. Specifically, we examine the stability of H-, Cl-, Br-, and I-passivated Si(100) in inert N 2 and ambient environments. Characterization with scanning tunneling microscopy and x-ray photoelectron spectroscopy (XPS) confirmed that each of the fully passivated surfaces were resistant to oxidation in 1 atm of N 2 for up to 44 h. Varying levels of surface degradation and contamination were observed upon exposure to the laboratory ambient environment. Characterization by ex situ XPS after ambient exposures ranging from 15 min to 8 h indicated the Br– and I–passivated Si surfaces were highly resistant to degradation, while Cl–passivated Si showed signs of oxidation within minutes of ambient exposure. As a proof-of-principle demonstration of pattern preservation, a H–passivated Si sample patterned and passivated with independent Cl, Br, I, and bare Si regions was shown to maintain its integrity in all but the bare Si region post-exposure to an N 2 environment. The successful demonstration of the preservation of APAM patterns outside of UHV environments opens new possibilities for transporting atomically-precise devices outside of UHV for integrating with non-UHV processes, such as other chemistries and commercial semiconductor device processes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A rotor-based multileaf collimator for beam shaping

We introduce a new style of multileaf collimator which employs rotors with angularly dependent radius to control the masking aperture: a rotor-based multileaf collimator (RMLC). Using a padlock-inspired mechanism, a single motor can set dozens of rotors, i.e. leaves, independently. This is especially important for an ultra-high vacuum (UHV) compatible MLC, since this reduces the number of actuators and vacuum feedthroughs required by more than an order of magnitude. This new RMLC will complement previous work employing a UHV compatible MLC with an emittance exchange beamline to create arbitrarily shaped beams on demand. A feed-forward control system which abstracts away the complexity of the RMLC operation, and is adaptable to real beamline conditions, is discussed and demonstrated in simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Removal of deuterium retained in boron powder by oxygen or high-temperature bakeout

Fuel retention in dust accumulated in fusion devices is a potential operational hazard. Boronization is one of the leading wall-conditioning candidates for future fusion devices. Fuel retention characteristics of boron dust must be studied to accurately understand the potential hazards of boron dust in fusion devices. We evaluated the retention of deuterium (D) in commercially available boron powder as a proxy for tritium retention in boron dust. Diffuse reflectance infrared Fourier transform spectroscopy revealed that boron powder between 300 and 500 K exposed to neutral hydrogen (H 2 ) gas retains H via B-H bonding. We utilized D 2 exposures of 17,400 L on the boron powder, which led to retention on the order of 0.5 g D per 100 kg B or 1.2 g D per m 2 B, as estimated from temperature programmed desorption measurements. We evaluated how powder bakeouts under ultra-high vacuum (UHV), or in an oxygen (O 2 ) or H 2 gas backfilled environment can remove the retained fuel. Bakeouts below 523 K under UHV exhibited poor D removal, promoting recapture of D 2 present as background gas in the chamber. Higher temperature bakeouts led to the removal of over 80% of the retained D within 3 days (623 K) or 1 h (723 K). Bakeouts at 423 K under an O 2 gas environment removed ∼150% more retained D from the boron powder, when compared to bakeouts conducted under UHV. These results suggest that efficient fuel removal from boron dust can be achieved by high-temperature bakeout (>623 K) or by bakeouts at lower temperature (423 K) under an O 2 environment.

Bakeout↗

Characterizing Complex Gas–Solid Interfaces with in Situ Spectroscopy: Oxygen Adsorption Behavior on Fe–N–C Catalysts

Electrocatalysts for the oxygen reduction reaction within polymer electrolyte membrane fuel cells based on iron, nitrogen, and carbon elements (Fe–N–C) are receiving significant research attention as they offer an inexpensive alternative to catalysts based on platinum-group metals. Although both the performance and the fundamental understanding of Fe–N–C catalysts have improved over the past decade, there remains a need to differentiate the relative activity of different active sites. Toward this goal, our study is focused on characterizing the interactions between O 2 and a set of five structurally different Fe–N–C materials. Detailed characterization of the Fe speciation was performed with 57 Fe Mössbauer spectroscopy and soft X-ray absorption spectroscopy of the Fe L 3,2 -edge, whereas nitrogen chemical states were investigated with X-ray photoelectron spectroscopy (XPS). In addition to initial sXAS and XPS measurements performed in ultra-high vacuum (UHV), measurements were also performed (at the identical location) in an atmosphere of 100 mTorr of O 2 at 80 °C (O 2 -rich). XPS and sXAS results reveal the presence of several types of FeNxCy adsorption sites. FeNxCy sites that are proposed as the most active ones do not show significant change (based on the techniques used in this study) when their environment is changed from UHV to O 2 -rich. Correlation with Mössbauer and sXAS results suggests that this is most likely due to the persistence of strongly adsorbed O 2 molecules from their previous exposure to air. However, other species do show spectroscopic changes from UHV conditions to O 2 -rich. This implies that these sites have a weaker interaction with O 2 that results in their desorption in vacuum conditions and re-adsorption when exposed to the O 2 -rich environment. The nature of these weakly and strongly O 2 -adsorbing FeN x C y sites is discussed in the context of different synthetic and processing parameters employed to fabricate each of these five Fe–N–C materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Controlling Selective C–O and C–H Bond Scission of Methanol by Supporting Pt on TiN and Mo 2 N Model Surfaces and Powder Catalysts

Transition metal nitrides (TMNs) have been explored as effective supports for Pt due to their Pt-like electronic properties. However, there is a lack of fundamental understanding regarding the behavior of Pt on different TMNs (Pt/TMN). Herein two TMNs, Mo 2 N and TiN, were modified with Pt and compared using methanol decomposition as a probe reaction via both ultrahigh vacuum (UHV) studies on thin films and ambient-pressure batch reactor studies of powder catalysts. Temperature-programmed desorption (TPD) and high-resolution electron energy loss spectroscopy (HREELS) measurements were conducted under UHV conditions with Mo 2 N and TiN thin films. Mo 2 N was shown to favor C–H bond scission to form CO with a 56.2% selectivity, while TiN favored C–O bond scission to form CH 4 with a 74.5% selectivity. The addition of 0.9 monolayers (MLs) of Pt increased C–H bond scission selectivity to 89.7% and 49.2% for Mo 2 N and TiN respectively. Density functional theory (DFT) calculations on model surfaces revealed that the binding energy of O (BE *O ) was significantly reduced on Pt/TMNs, from −4.02 eV on Mo 2 N to −1.31 eV on Pt/Mo 2 N and −4.74 eV on TiN to −1.37 eV on Pt/TiN. As a result, C–O bond scission pathways were suppressed, leading to the preferential C–H bond scission that was observed experimentally. The C–O and C–H bond scission trends observed on thin films were then extended to powder catalysts, which demonstrated similar trends toward methanol decomposition. In conclusion, results from the current study establish that by combining UHV studies and DFT calculations over model surfaces, one can effectively predict the catalytic behavior of realistic TMN powder catalysts.

08 HYDROGEN↗

Pt Particles on a Dynamic TiO 2 Support in Near-Ambient Conditions−Disentangling Size, Pressure, and Support Effects

Platinum particles on reducible oxides are known to form complex and highly dynamic catalyst systems at elevated pressures and temperatures, often adopting active structures that differ from those found at room temperature and under ultrahigh vacuum (UHV). Here, we study the oxidation and structural evolution of subnanometer Pt clusters and nanoparticles supported on rutile TiO 2 (110) across an oxygen pressure range from UHV to 0.1 mbar, using near-ambient pressure X-ray photoelectron spectroscopy (NAP-XPS), scanning tunneling microscopy (STM) under UHV and NAP conditions, and low-energy ion scattering (LEIS). Our results reveal distinct differences in oxidation behavior and thermal stability between Pt nanoparticles and clusters, which are further modulated by the support stoichiometry and oxygen pressure. Small Pt clusters become oxidized even at room temperature but are susceptible to accelerated sintering in 0.1 mbar O 2 at elevated temperatures. In contrast, well-crystallized Pt nanoparticles on near-stoichiometric TiO 2 show weaker oxidation. On a reduced, defective TiO 2 support, Pt instead quickly becomes deeply buried by new titania layers, which are formed during support reoxidation. This process appears to result primarily from interactions of the support with the gas phase, unlike the classical, selflimited encapsulation that is induced by the strong metal−support interaction (SMSI). Finally, we address the full complexity of real catalysts in a direct side-by-side comparison of the single-crystalline model system with a Pt-loaded TiO 2 powder catalyst (P25). We conclude that the stoichiometry of the model supports must be carefully chosen and controlled to accurately reproduce the expected state of powder supports during redox reactions.

metal nanoparticles↗

Cryogen-free modular scanning tunneling microscope operating at 4-K in high magnetic field on a compact ultra-high vacuum platform

One of the daunting challenges in modern low temperature scanning tunneling microscopy (STM) is the difficulty of combining atomic resolution with cryogen-free cooling. Further functionality needs, such as ultra-high vacuum (UHV), high magnetic field (HF), and compatibility with μm-sized samples, pose additional challenges to an already ambitious build. We present the design, construction, and performance of a cryogen-free, UHV, low temperature, and high magnetic field system for modular STM operation. An internal vibration isolator reduces vibrations in this system, allowing for atomic resolution STM imaging while maintaining a low base temperature of ∼4 K and magnetic fields up to 9 T. Samples and tips can be conditioned in situ utilizing a heating stage, an ion sputtering gun, an e-beam evaporator, a tip treater, and sample exfoliation. In situ sample and tip exchange and alignment are performed in a connected UHV room temperature stage with optical access. Multisite operation without breaking vacuum is enabled by a unique quick-connect STM head design. A novel low-profile vertical transfer mechanism permits transferring the STM between room temperature and the low temperature cryostat.

Instruments & Instrumentation↗

Impact of metal diffusion, lattice distortions, native defects, and ambient on dielectric breakdown in Ni–Ga 2 O 3 Schottky diodes

Ga 2 O 3 unipolar devices are of high interest due to their ~8 MV/cm predicted breakdown fields, which have not yet been achieved due to premature device failure. Pre- and post-failure defect analysis of Ni–Ga 2 O 3 Schottky diodes in ultrahigh vacuum (UHV) and air were performed using depth-resolved cathodoluminescence, high angle annular dark field scanning transmission electron microscopy, and energy dispersive x-ray analysis to understand the physical mechanisms that precede premature breakdown. The breakdown voltage in UHV was dramatically reduced by nearly 40% compared with the breakdown in air. This reduction in the breakdown voltage correlated with post-breakdown differences in Ni distribution, indicating that the coordination and bonding of Ni contribute strongly to electrical behavior in Ni–Ga 2 O 3 Schottky diodes. Breakdown studies in UHV revealed that Ni diffuses away more from the metal–semiconductor interface than with air breakdown, where Ni localizes more near the interface, indicative of the preferential formation of a Ni oxide under O-poor conditions. These measurements also identified the formation of divacancy-interstitial complexes and their characteristic luminescence signature ~150 nm from the interface, the densities of which correlated with breakdown fields. These findings show that electric-field-induced degradation occurs via the rearrangement of native point defects, which act as an additional precursor to device failure. Macroscopically, they show the impact of both vacuum conditions and metal reactivity on Ga 2 O 3 device fabrication.

36 MATERIALS SCIENCE↗

Deployable Element Ultra-High Vacuum Pump

Advancing Ultra High Vacuum (UHV) Pumping Technology: The deployable UHV pump team has designed a theoretical model to boost efficiency in high vacuum environments. Traditional systems face challenges with random molecular motion. The innovative windmill design, using titanium sublimation technology, reduces randomness by deploying a gettering surface that actively captures particles. This marks a notable advancement in UHV pumping technology.

43 PARTICLE ACCELERATORS↗

One-dimensional heterocyclic carbene–Au metal–organic frameworks bridging ultra-high vacuum models and scalable liquid-phase growth

The controlled design of molecule–metal interfaces is central to the development of functional nanomaterials for catalysis, sensing, and molecular electronics. Here we show that the adsorption of a Janus-type diimidazolium precursor on gold yields one-dimensional (1D) N-heterocyclic carbene (NHC)–Au–NHC metal organic frameworks (MOFs) featuring positively charged gold nodes. Using synchrotron X-ray photoemission spectroscopy (XPS), near edge X-ray adsorption fine structure (NEXAFS) spectroscopy and scanning tunnelling microscopy (STM), we demonstrate that thermal activation promotes counterion removal and drives the formation of extended 1D arrays, characterized by ∼1.0 nm Au–Au spacing and adatom densities up to 0.6 atom nm −2 (∼4% of surface atoms). Importantly, we translate this ultra-high vacuum (UHV) benchmark into a scalable solution-phase protocol in ethanol, enabling 1D-MOF growth under mild, base-free, open-air conditions. The resulting films retain structural and electronic signatures of UHV-grown systems, bridging model studies and practical synthesis. This approach establishes NHC–metal frameworks as accessible, tunable platforms for catalysis and materials design.

Gold adatoms↗

The interaction of acetonitrile with H-terminated and depassivated (100) diamond surfaces

Molecular adsorption on reactive semiconductor surfaces may enable novel surface functionalisation and atomically-precise dopant formation. In this work synchrotron-based x-ray photoelectron spectroscopy and near edge x-ray absorption spectroscopy are used to examine the interaction between acetonitrile and diamond (100) surfaces under ultrahigh vacuum (UHV) conditions. We observe two surface-bound nitrogen species on hydrogen terminated surfaces after thermal depassivation or following synchrotron radiation and subsequent exposure to acetonitrile, but find no evidence of nitrogen adsorption on the hydrogen-terminated diamond surface, at room temperature. Subsequent measurements explore the stability of the surface-bound nitrogen under various temperature conditions and with atmospheric exposure. While the nitrogen coverage achieved in this study is low, this study serves as a proof-of-concept demonstration of a UHV molecular dosing approach to selective nitrogen functionalisation of diamond surfaces as an alternative to plasma-based approaches. This development may be critical for proposed surface-based fabrication workflows using atomic placement of nitrogen-vacancy centres to create quantum devices.

74 ATOMIC AND MOLECULAR PHYSICS↗