Search NASA⌕ Search

SEARCH · Search NASA

Results for “UL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Validating the Test Procedures Described in UL 1741 SA and IEEE P1547.1: Preprint

This paper investigates the test procedures specified in UL 1741 SA and the upcoming revision to IEEE P1547.1. A 550 kVA photovoltaic inverter was chosen for the tests. This research reveals some of key the components to consider while doing certification tests for UL 1741 SA and IEEE P1547.1. This paper also identifies some issues requiring consideration for future releases of the standard, i.e. IEEE P1547.1. This paper investigates the test procedures specified in UL 1741 SA and the upcoming revision to IEEE P1547.1. A 550 kVA photovoltaic inverter was chosen for the tests. This research reveals some of key the components to consider while doing certification tests for UL 1741 SA and IEEE P1547.1. This paper also identifies some issues requiring consideration for future releases of the standard, i.e. IEEE P1547.1.

14 SOLAR ENERGY↗

An Investigation of Passive and Semi-Active Tuned Mass Dampers for a Tension Leg Platform Floating Offshore Wind Turbine in ULS Conditions

Offshore Wind Turbines (OWTs) are subjected to complex external loadings caused by combined wind and wave sources. The application of structural damping control techniques to OWTs using Tuned Mass Dampers (TMDs) has shown to be effective in reducing the integrated system loads and accelerations. In this work, the impact of passive and semi-active (S-A) TMD’s applied to both fixed-bottom (monopile) and floating (tension leg platform) OWTs are evaluated under the Fatigue Limit State (FLS) and Ultimate Limit State (ULS). Different S-A control logics like ON/OFF state damping based on the ground hook (GH) control policy are implemented, and the frequency response of each algorithm is investigated. It is shown that the performance of each algorithm varies according to the load conditions such as FLS (normal operation) and ULS (idling state). Fully-coupled time domain simulations are conducted through the developed simulation tool for structural control integrated into the high-fidelity wind turbine design code, FASTv8. Compared to the passive TMD, it is shown that a S-A TMD results in higher load reductions, as well as, smaller strokes under both FLS and ULS conditions. In FLS analysis, the S-A TMD using Displacement Based Ground Hook (DB-GH) control is capable of reducing the fore-aft and side-to-side damage equivalent loads for the monopile substructure by approximately 12 % and 64 %, respectively. The ultimate loads at the tower base for the floating substructure (TLP) are also reduced by 9% with S-A TMD followed by Inverse Velocity Based Ground Hook control (IVB-GH). The dynamic characteristics and practical feasibility of a magnetorheological (MR) damper (for S-A control) are also evaluated.

17 WIND ENERGY↗

Validating the Test Procedures Described in UL 1741 SA and IEEE P1547.1

This paper investigates the test procedures specified in UL 1741 SA and the upcoming revision to IEEE P1547.1. A 550 kVA photovoltaic inverter was chosen for the tests. This research reveals some of the key components to consider while doing certification tests for UL 1741 SA and IEEE P1547.1. This paper also identifies some issues requiring consideration for future releases of the standard, i.e. IEEE P1547.1.

14 SOLAR ENERGY↗

UL 1741SC Conformance Development, Evaluation, and Proposal [Slides]

V2G AC is a type of grid interconnection by mobile battery that transforms an EV into a DER with the potential to stabilize the grid and lower costs for electricity. UL 1741SC is a critical new standard to enable grid interconnection of V2G AC-capable vehicles, by defining requirements for V2G AC-intended EVSEs as a gatekeeper between the grid and the EV to support grid safety, such as through redundant voltage trip (namely oversight). EVSE manufacturers need a clear set of conformance test cases and criteria by which to evaluate their equipment and confirm the compliance with UL 1741SC, so that the EVSEs performs as intended for the grid safety. Hence, NLR identified necessary conformance tests and performed the tests identified to understand the maturity.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Preliminary Experiences with the Rexon UL-320-FDR: An Automated Thermoluminescent Dosimeter Reader with Removable Contact Heating Planchets and an Infrared Temperature Feedback System

The Rexon UL-320 FDR is a novel resistive-heating thermoluminescent dosimeter reader with a unique temperature measurement system and an automated dosimeter processing mechanism. The removable contact heating planchets have black-body adhesives on the back for capturing temperature information with infrared sensors. A heating cycle feedback loop ensures accurate, precise, and reproducible heating sequences. Heating rates between 0.8 and 40°C s -1 for up to 1,000 s are possible. Photomultiplier tube sensitivity and drift, dark current counts, and planchet glow were measured experimentally. Additionally, 25 LiF:Mg,Ti dosimeters were calibrated to demonstrate reader performance. Sensitivity was optimized at 1,200 V, which produced the highest reference light count to dark current count ratio while extending photomultiplier tube life. Dark current counts measured with typical time-temperature profiles for LiF:Mg,Ti were below 10 counts per channel but increased by up to 2.5% for more extreme heating cycles. Reader sensitivity drifts of up to 10% were observed during extended automated operations with typical time-temperature profiles. Total counts resulting from planchet glow decreased with faster heating rates. Calibrations performed with LiF:Mg,Ti dosimeters yielded results comparable to more established reader designs. Spikes were observed in ~3% of the glow curves from planchet dust and oil burning off at elevated temperatures. The use of N 2 gas and sensitivity drift corrections are recommended to improve dosimetry performance for the UL-320 FDR reader.

61 RADIATION PROTECTION AND DOSIMETRY↗

Fire Resistance Development for UL 790 Burning Brand Test (CRADA Final Report)

Class A burning brand (UL 790) tests are used to determine the roof covering's effectiveness against severe exposure to external fire. Unfortunately, these tests can be costly to repeatedly perform when iteratively developing new materials/designs. The NREL team will work with the R&D Lab to develop and deploy computational tools to facilitate rapid development of roofing materials for the UL 790 standard test.

14 SOLAR ENERGY↗

Study of the exclusive b{yields}ul{sup -}{nu}{sub l} decays in the MSSM with and without R-parity violation

We study the exclusive b{yields}ul{sup -}{nu}{sub l}(l={tau},{mu},e) decays in the minimal supersymmetric standard model with and without R-parity violation. From the experimental measurements of branching ratios B(B{sub u}{sup -}{yields}{tau}{sup -}{nu}{sub {tau}}), B(B{sub u}{sup -}{yields}M{sup '0}l{sup '-}{nu}{sub l{sup '}}) and B(B{sub d}{sup 0}{yields}M{sup '+}l{sup '-}{nu}{sub l{sup '}}) (l{sup '}={mu},e,M{sup '}={pi},{rho}), we derive new upper bounds on the relevant new physics parameters within the decays. Using the constrained new physics parameter spaces, we predict the charged Higgs effects and the R-parity violating effects on the branching ratios, the normalized forward-backward asymmetries of charged leptons, and the ratios of longitudinal to transverse polarization of the vector mesons, which have not been measured or have not been well measured yet. We find that the charged Higgs effects and the R-parity violating effects could be large and measurable in some cases. Our results could be used to probe new physics effects in the leptonic decays as well as the semileptonic decays, and will correlate with searches for direct supersymmetric signals in future experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An Investigation of Passive and Semi-Active TMD for a TLP Floating Offshore Wind Turbine in ULS Conditions

Floating offshore wind turbines are able to access deeper waters with stronger winds, but also have more complicated dynamic behavior than fixed-bottom offshore turbines, potentially resulting in larger loads. Structural control using tuned mass dampers (TMD) is a promising method for mitigating these loads. Previous research on structural control in wind turbines has typically considered passive devices and operational conditions. In this study, the effects of a passive tuned mass damper and a semi-active tuned mass damper, located at the tower top, are analyzed and simulated for the GE Haliade 150-6MW wind turbine located on the Glosten Pelastar tension-leg platform (TLP).

offshore wind turbines, dampers, tuned mass, semi-↗

SaS4D Home Team Ul

This software allows for a lidar-generated point cloud to be converted to a water-tight geometry, and finally an MCNP radiation transport input deck automatically. This includes the automatic registration of detectors and placement of pre-generated radiation transport models of these detectors in the scene.

Swinney, Mathew↗

Defect-reduction mechanism for improving radiative efficiency in InGaN/GaN light-emitting diodes using InGaN underlayers

The influence of a dilute In{sub x}Ga{sub 1-x}N (x ∼ 0.03) underlayer (UL) grown below a single In{sub 0.16}Ga{sub 0.84}N quantum well (SQW), within a light-emitting diode (LED), on the radiative efficiency and deep level defect properties was studied using differential carrier lifetime (DCL) measurements and deep level optical spectroscopy (DLOS). DCL measurements found that inclusion of the UL significantly improved LED radiative efficiency. At low current densities, the non-radiative recombination rate of the LED with an UL was found to be 3.9 times lower than the LED without an UL, while the radiative recombination rates were nearly identical. This suggests that the improved radiative efficiency resulted from reduced non-radiative defect concentration within the SQW. DLOS measurement found the same type of defects in the InGaN SQWs with and without ULs. However, lighted capacitance-voltage measurements of the LEDs revealed a 3.4 times reduction in a SQW-related near-mid-gap defect state for the LED with an UL. Quantitative agreement in the reduction of both the non-radiative recombination rate (3.9×) and deep level density (3.4×) upon insertion of an UL corroborates deep level defect reduction as the mechanism for improved LED efficiency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗