Measurement of hypersonic sound speeds in methane at moderate pressures
Measurement of hypersonic sound speeds in methane at moderate pressure and comparison with ultrasonic speed data
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Measurement of hypersonic sound speeds in methane at moderate pressure and comparison with ultrasonic speed data
Ultrasonic device consisting of a coaxial rod and transducer enclosed in a cylindrical probe which is filled with deionized or distilled water speeds up the testing of welds. Rubber diaphragm is molded to produce the desired test beam angle.
Horizontal and vertical wind speed and direction from ultrasonic wind sensor (Thies Clima Ultrasonic 3D Anemometer)
This study compared peak wind speeds reported by mechanical and ultrasonic anemometers at Cape Canaveral Air Force Station and Kennedy Space Center (CCAFS/KSC) on the east central coast of Florida and Vandenberg Air Force Base (VAFB) on the central coast of California. Launch Weather Officers, forecasters, and Range Safety analysts need to understand the performance of wind sensors at CCAFS/KSC and VAFB for weather warnings, watches, advisories, special ground processing operations, launch pad exposure forecasts, user Launch Commit Criteria (LCC) forecasts and evaluations, and toxic dispersion support. The legacy CCAFS/KSC and VAFB weather tower wind instruments are being changed from propeller-and-vane (CCAFS/KSC) and cup-and-vane (VAFB) sensors to ultrasonic sensors under the Range Standardization and Automation (RSA) program. Mechanical and ultrasonic wind measuring techniques are known to cause differences in the statistics of peak wind speed as shown in previous studies. The 45th Weather Squadron (45 WS) and the 30th Weather Squadron (30 WS) requested the Applied Meteorology Unit (AMU) to compare data between the RSA ultrasonic and legacy mechanical sensors to determine if there are significant differences. Note that the instruments were sited outdoors under naturally varying conditions and that this comparison was not designed to verify either technology. Approximately 3 weeks of mechanical and ultrasonic wind data from each range from May and June 2005 were used in this study. The CCAFS/KSC data spanned the full diurnal cycle, while the VAFB data were confined to 1000-1600 local time. The sample of 1-minute data from numerous levels on five different towers on each range totaled more than 500,000 minutes of data (482,979 minutes of data after quality control). The ten towers were instrumented at several levels, ranging from 12 ft to 492 ft above ground level. The ultrasonic sensors were collocated at the same vertical levels as the mechanical sensors and typically within 15 ft horizontally of each another. Data from a total of 53 RSA ultrasonic sensors, collocated with mechanical sensors were compared. The 1- minute average wind speed/direction and the 1-second peak wind speed/direction were compared.
This study focuses on a comparison of peak wind speeds reported by mechanical and ultrasonic anemometers at Cape Canaveral Air Force Station and Kennedy Space Center (CCAFS/KSC) on the east central coast of Florida and Vandenberg Air Force Base (VAFB) on the central coast of California. The legacy mechanical wind instruments on CCAFS/KSC and VAFB weather towers are being changed from propeller-and-vane (CCAFS/KSC) and cup-and-vane (VAFB) sensors to ultrasonic sensors under the Range Standardization and Automation (RSA) program. The wind tower networks on KSC/CCAFS and VAFB have 41 and 27 towers, respectively. Launch Weather Officers, forecasters, and Range Safety analysts at both locations need to understand the performance of the new wind sensors for a myriad of reasons that include weather warnings, watches, advisories, special ground processing operations, launch pad exposure forecasts, user Launch Commit Criteria (LCC) forecasts and evaluations, and toxic dispersion support. The Legacy sensors measure wind speed and direction mechanically. The ultrasonic RSA sensors have no moving parts. Ultrasonic sensors were originally developed to measure very light winds (Lewis and Dover 2004). The technology has evolved and now ultrasonic sensors provide reliable wind data over a broad range of wind speeds. However, because ultrasonic sensors respond more quickly than mechanical sensors to rapid fluctuations in speed, characteristic of gusty wind conditions, comparisons of data from the two sensor types have shown differences in the statistics of peak wind speeds (Lewis and Dover 2004). The 45th Weather Squadron (45 WS) and the 30 WS requested the Applied Meteorology Unit (AMU) to compare data from RSA and Legacy sensors to determine if there are significant differences in peak wind speed information from the two systems.
A common method of determining elastic material properties is utilizing an ultrasonic pulse receiver. This is a non-destructive test (NDT) causing no plastic deformation of the material. It requires a pulse generator, oscilloscope, and two transducers to measure the sound velocity of a material. Both longitudinal and shear sound velocities may be obtained by utilizing the appropriate transducer. Acoustic nondestructive testing methods are often used in manufacturing certification processes and for material defect detection in industry. These methods can also be utilized to directly measure the elastic moduli of a material without damaging the material. Overall, it is a low-cost experiment with minimal preparation, and is easy to use.
This study compared the performance of mechanical and ultrasonic anemometers at the Eastern Range (ER; Kennedy Space Center and Cape Canaveral Air Force Station on Florida's Atlantic coast) and the Western Range (WR; Vandenberg Air Force Base on California's Pacific coast). Launch Weather Officers, forecasters, and Range Safety analysts need to understand the performance of wind sensors at the ER and WR for weather warnings, watches, advisories, special ground processing operations, launch pad exposure forecasts, user Launch Commit Criteria (LCC) forecasts and evaluations, and toxic dispersion support. The current ER and WR weather tower wind instruments are being changed from the current propeller-and-vane (ER) and cup-and-vane (WR) sensors to ultrasonic sensors through the Range Standardization and Automation (RSA) program. The differences between mechanical and ultrasonic techniques have been found to cause differences in the statistics of peak wind speed in previous studies. The 45th Weather Squadron (45 WS) and the 30th Weather Squadron (30 WS) requested the Applied Meteorology Unit (AMU) to compare data between RSA and current sensors to determine if there are significant differences. Approximately 3 weeks of Legacy and RSA wind data from each range were used in the study, archived during May and June 2005. The ER data spanned the full diurnal cycle, while the WR data was confined to 1000-1600 local time. The sample of 1-minute data from numerous levels on 5 different towers on each range totaled more than 500,000 minutes of data (482,979 minutes of data after quality control). The 10 towers were instrumented at several levels, ranging from 12 ft to 492 ft above ground level. The RSA sensors were collocated at the same vertical levels as the present sensors and typically within 15 ft horizontally of each another. Data from a total of 53 RSA ultrasonic sensors, collocated with present sensors were compared. The 1-minute average wind speed/direction and the 1-second peak wind speed/direction were compared.
Ultrahigh speed electro-optical systems employing fiber optics
The propagation of ultrasonic pulses in pyrophyllite specimens was studied to determine the effect of specimen precompression on the measured elastic moduli. Measurements were made at room pressure and, for the precompressed specimens, to pressures of 3 kbar. Pyrophyllite was found to be elastically anisotropic, apparently the result of the fabric present in our material. The room pressure adiabatic bulk modulus as measured on specimens made of isostatically compacted powered pyrophyllite was determined to be 96.1 kbar. The wave speeds of ultrasonic pulses in pyrophyllite were found to decrease with increasing specimen precompression. A limiting value of precompression was found, above which no further decrease in wave speed was observed. For the shear wave speeds this occurs at 10 kbar while for the longitudinal wave at 25 kbar. In the limit, the shear waves propagate 20% slower than in the unprecompressed samples; for the longitudinal wave the difference is 30%.
A three-dimensional (3D) Venturi sensor is being developed as a compact, rugged means of measuring wind vectors having magnitudes of as much as 300 mph (134 m/s). This sensor also incorporates auxiliary sensors for measuring temperature from -40 to +120 F (-40 to +49 C), relative humidity from 0 to 100 percent, and atmospheric pressure from 846 to 1,084 millibar (85 to 108 kPa). Conventional cup-and-vane anemometers are highly susceptible to damage by both high wind forces and debris, due to their moving parts and large profiles. In addition, they exhibit slow recovery times contributing to an inaccurately high average-speed reading. Ultrasonic and hot-wire anemometers overcome some of the disadvantages of the cup and-vane anemometers, but they have other disadvantageous features, including limited dynamic range and susceptibility to errors caused by external acoustic noise and rain. In contrast, the novel 3D Venturi sensor is less vulnerable to wind damage because of its smaller profile and ruggedness. Since the sensor has no moving parts, it provides increased reliability and lower maintenance costs. It has faster response and recovery times to changing wind conditions than traditional systems. In addition, it offers wide dynamic range and is expected to be relatively insensitive to rain and acoustic energy. The Venturi effect in this sensor is achieved by the mirrored double-inflection curve, which is then rotated 360 to create the desired detection surfaces. The curve is optimized to provide a good balance of pressure difference between sensor ports and overall maximum fluid velocity while in the shape. Four posts are used to separate the two shapes, and their size and location were chosen to minimize effects on the pressure measurements. The 3D Venturi sensor has smart software algorithms to map the wind pressure exerted on the surfaces of the design. Using Bernoulli's equation, the speed of the wind is calculated from the differences among the pressure readings at the various ports. The direction of the wind is calculated from the spatial distribution and magnitude of the pressure readings. All of the pressure port sizes and locations have been optimized to minimize measurement errors and to reside in areas demonstrating a stable pressure reading proportional to the velocity range.
Ultrasonic thickness measurement of mechanical structures is one of the most popular and commonly used nondestructive methods for various kinds of process control and corrosion monitoring. With ultrasonic propagation speed being temperature-dependent, the thickness measurement can be performed reliably only when the thermal profile is completely known. Most conventional techniques assume the temperature of the test structure is uniform and at room temperature across its thickness. Such assumptions may lead to large errors in the thickness measurement, especially when there are significant temperature variations across the thickness. State-of-the-art techniques use external temperature measurements or implement iterative methods to compensate for the unknown thermal profiles. However, such techniques produce unsatisfactory results when the heat distribution is complex or varies rapidly with time. In this work, we propose a two-sensors technique, using both compressive and shear excitations, with a non-iterative rapid data processing method for accurate thickness measurement under arbitrary time-variant thermal profile. The independent behavior of shear and compressive waves is used to formulate a real-time thickness estimation technique. The developed technique is experimentally validated on a steel plate with fixed acoustic sensors. Test results show that the error in thickness estimation can be reduced by up to 98% compared to conventional thickness gauging methods.
In this work, the Common Model of Multi-phase Strength and Equation of State (CMMP) model was applied to tin. Specifically, calibrations of the strength-specific elements of the CMMP foundation were developed with a combination of experiments and theory, and then the model was validated experimentally. The first element of the foundation is a multi-phase analytic treatment of the melt temperature and the shear modulus for the solid phases. These models were parameterized for each phase based on ab initio calculations using the software VASP (Vienna Ab initio Simulations Package) based on density functional theory. The shear modulus model for the ambient phase was validated with ultrasonic sound speed measurements as a function of pressure and temperature. The second element of the foundation is a viscoplastic strength model for the phase, upon which strength for inaccessible higher-pressure phases can be scaled as necessary. The stress–strain response of tin was measured at strain rates of 10 -3 to 3 x 10 3 s -1 and temperatures ranging from 87 to 373 K. The Preston–Tonks–Wallace (PTW) strength model was fit to that data using Bayesian model calibration. For validation, six forward and two reverse Taylor impact experiments were performed at different velocities to measure large plastic deformation of tin at strain rates up to 10 5 s -1 . The PTW model accurately predicted the deformed shapes of the cylinders, with modest discrepancies attributed to the inability of PTW to capture the effects of twinning and dynamic recrystallization. Some material in the simulations of higher velocity Taylor cylinders reached the melting temperature, thus testing the multiphase model because of the presence of a second phase, the liquid. In simulations using a traditional modeling approach, the abrupt reduction of strength upon melt resulted in poor predictions of the deformed shape and non-physical temperatures. With CMMP, the most deformed material points evolved gradually to a mixed solid–liquid but never a fully liquid state, never fully lost strength, stayed at the melt temperature as the latent heat of fusion was absorbed, and predicted the deformed shape well.
In this work, the Common Model of Multi-phase Strength and Equation of State (CMMP) model was applied to tin. Specifically, calibrations of the strength-specific elements of the CMMP foundation were developed with a combination of experiments and theory, and then the model was validated experimentally. The first element of the foundation is a 10 multi-phase analytic treatment of the melt temperature and the shear modulus for the solid phases. These models were parameterized for each phase based on ab initio calculations using the software VASP (Vienna Ab initio Simulations Package) based on density functional theory (DFT). The shear modulus model for the ambient β phase was validated with ultrasonic sound speed measurements as a function of pressure and temperature. The second element of the foundation is a viscoplastic strength model for the β phase, upon which strength for inaccessible higher-pressure phases can be scaled as necessary. The stress-strain response of tin was measured at strain rates of 10 -3 to 3 x 10 3 s -1 and temperatures ranging from 87 to 373 K. The Preston-Tonks-Wallace (PTW) strength model was fit to that data using Bayesian model calibration. For validation, six forward and two reverse Taylor impact experiments were performed at different velocities to measure large plastic deformation of tin at strain rates up to 10 5 s -1 . The PTW model accurately predicted the deformed shapes of the cylinders, with modest discrepancies attributed to the inability 20 of PTW to capture the effects of twinning and dynamic recrystallization. Some material in the simulations of higher velocity Taylor cylinders reached the melting temperature, thus testing the multiphase model because of the presence of a second phase, the liquid. In simulations using a traditional modeling approach, the abrupt reduction of strength upon melt resulted in poor predictions of the deformed shape and non-physical temperatures. With CMMP, the most deformed material points evolved gradually to a mixed solid-liquid but never fully liquid state, never fully lost strength, 25 stayed at the melt temperature as the latent heat of fusion was absorbed, and predicted the deformed shape well.
Ultrasonic interferometer for high-pressure research
Automated tow placement has become a widely used fabrication technique, especially for large aerospace structures. Robotic heads lay down strips (tows) of preimpregnated fiber along programmed paths. The intention is to lay adjacent tows abutted to one another, but sometimes a gap is left between a tow and the previously-placed tow. If a tow gap exists, it fills with resin during cure, forming a fiber-free volume. In immersion ultrasonic pulse-echo measurements of a cured laminate, the gap can be observed to produce a noticeable echo, without significantly attenuating the back-wall reflection of the laminate. To understand this behavior, we considered a one dimensional model of the composite laminate, with a thin layer having the ultrasonic sound speed and density of neat resin, sandwiched between two layers of material having the sound speed and density of fiber-reinforced composite and surrounded on both sides by water. Neglecting attenuation, we considered the transmission and reflection coefficients of each interface, as well as that of the thin resin layer. Using the initial water/composite reflection as a reference, we computed the relative magnitude of the back surface/water reflection in the presence and in the absence of a resin-only layer, as well as the relative magnitude of the reflection arising from a thin resin layer in composite. While the one-dimensional model did not fully match the measurements, it did qualitatively explain the observed behavior.
Ultrasonic techniques that have demonstrated potential for material characterization are reviewed. These techniques rely on physical acoustic properties of materials and the interaction of elastic stress waves with morphological factors in the ultrasonic regime. The speed of wave propagation and energy loss by interaction with material microstructure and geometrical factors underlie ultrasonic determination of material properties. Two categories of ultrasonic measurements are discussed: those related to material strengths (e.g., elastic moduli, tensile strength, and fracture toughness) and those related to morphology and material conditions that govern strength and performance (e.g., microstructure, void content, residual stress, fatigue damage). It is shown that large-scale industrial application of ultrasonic NDE will depend on advancement in such areas as theory development, instrumentation, system automation, standardization, and coordination with design.
Measurements of wind noise reduction were conducted on a box-shaped, subsurface windscreen made of closed cell polyurethane foam. The windscreen was installed in the ground with the lid flush with the ground surface. The wind was generated by means of a fan, situated on the ground, and the wind speed was measured at the center of the windscreen lid with an ultrasonic anemometer. The wind speed was controlled by moving the fan to selected distances from the windscreen. The wind noise was measured on a PCB Piezotronics 3†electret microphone. Wind noise spectra were measured with the microphone exposed directly to the wind (atop the windscreen lid) and with the microphone installed inside the windscreen. The difference between the two spectra comprises the wind noise reduction. At wind speeds of 3, 5, and 7 m/s, the wind noise reduction is typically 15 dB over the frequency range of 0.1-20 Hz.
The present collection of papers outlines advances in ultrasonography, scintigraphy, and commercialization of medical technology as applied to cardiovascular diagnosis in research and clinical practice. Particular attention is given to instrumentation, image processing and display. As necessary concomitants to mathematical analysis, recently improved magnetic recording methods using tape or disks and high-speed computers of large capacity are coming into use. Major topics include Doppler ultrasonic techniques, high-speed cineradiography, three-dimensional imaging of the myocardium with isotopes, sector-scanning echocardiography, and commercialization of the echocardioscope. Individual items are announced in this issue.