Search NASA⌕ Search

SEARCH · Search NASA

Results for “UPS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

City-level impacts of building tune-ups: Findings from Seattle's building tune-ups program

Many U.S. cities are implementing policies to reduce greenhouse gas (GHG) emissions of their buildings. These range from building energy benchmarking and disclosure to building performance standards (BPS) that require buildings to meet specific targets of energy use or emissions. The City of Seattle adopted a climate action plan in 2013 that set a goal of zero net GHG emissions in the road transportation, buildings, and waste sectors by 2050, with a number of near and long term actions. Seattle implemented mandatory building tune-ups in 2016, applying to commercial buildings larger than 50,000 sqft. Building tune-ups1 involve assessment and implementation of operational and maintenance (O + M) improvements to achieve energy and water efficiency, such as changes to thermostat set points or adjusting lighting or irrigation schedules. Seattle's tune-ups program covered 27 such improvements in HVAC, lighting, domestic hot water, and envelope systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Analytical investigation of the hygrothermal effects and parametric study of the Edge Crack Torsion (ECT) mode 3 test lay-ups

A shear deformation theory including residual thermal and moisture effects is developed for the analysis of either symmetric or unsymmetric laminates with mid-plane edge delamination under torsion loading. The theory is based on an assumed displacement field which includes shear deformation. The governing equations and boundary conditions are obtained from the principle of virtual work. The analysis of the (90/(+/- 45)(n)/(-/+ 45)(n)/90)(s) ECT mode 3 test lay-up indicates that there are no hygrothermal effects on the mode 3 strain energy release rate because the laminate, and both sublaminates above and below the delamination, are symmetric lay-ups. A further parametric study reveals that some other lay-ups can have negligible hygrothermal effects even when the sublaminates above and below the delamination are not symmetric about their own mid-planes. However, these lay-ups may suffer from distortion after the curing process. Another Interesting set of lay-ups investigated is a class of antisymmetric laminates with (+/-(theta/(theta -90)(2)/theta))(n) lay-ups. It is observed that when n takes on even numbers (2 and 4), both hygrothermal and mode 1 effects can be neglected. From this point of view, these lay-ups provide a way to determine the mode 3 toughness between two dissimilar layers. However, when n takes on odd numbers (1 and 3), both hygrothermal and mode 1 effects may be strong in these lay-ups. In particular, when theta equals 45 deg, the lay-ups are free from both hygrothermal and mode 1 effects irrespective of n.

Li, Jian↗

Common Cause Case Study: An Estimated Probability of Four Solid Rocket Booster Hold-down Post Stud Hang-ups

Until Solid Rocket Motor ignition, the Space Shuttle is mated to the Mobil Launch Platform in part via eight (8) Solid Rocket Booster (SRB) hold-down bolts. The bolts are fractured using redundant pyrotechnics, and are designed to drop through a hold-down post on the Mobile Launch Platform before the Space Shuttle begins movement. The Space Shuttle program has experienced numerous failures where a bolt has "hung-up." That is, it did not clear the hold-down post before liftoff and was caught by the SRBs. This places an additional structural load on the vehicle that was not included in the original certification requirements. The Space Shuttle is currently being certified to withstand the loads induced by up to three (3) of eight (8) SRB hold-down post studs experiencing a "hang-up." The results af loads analyses performed for four (4) stud-hang ups indicate that the internal vehicle loads exceed current structural certification limits at several locations. To determine the risk to the vehicle from four (4) stud hang-ups, the likelihood of the scenario occurring must first be evaluated. Prior to the analysis discussed in this paper, the likelihood of occurrence had been estimated assuming that the stud hang-ups were completely independent events. That is, it was assumed that no common causes or factors existed between the individual stud hang-up events. A review of the data associated with the hang-up events, showed that a common factor (timing skew) was present. This paper summarizes a revised likelihood evaluation performed for the four (4) stud hang-ups case considering that there are common factors associated with the stud hang-ups. The results show that explicitly (i.e. not using standard common cause methodologies such as beta factor or Multiple Greek Letter modeling) taking into account the common factor of timing skew results in an increase in the estimated likelihood of four (4) stud hang-ups of an order of magnitude over the independent failure case.

Cross, Robert↗

Common Cause Case Study: An Estimated Probability of Four Solid Rocket Booster Hold-Down Post Stud Hang-ups

Until Solid Rocket Motor ignition, the Space Shuttle is mated to the Mobil Launch Platform in part via eight (8) Solid Rocket Booster (SRB) hold-down bolts. The bolts are fractured using redundant pyrotechnics, and are designed to drop through a hold-down post on the Mobile Launch Platform before the Space Shuttle begins movement. The Space Shuttle program has experienced numerous failures where a bolt has hung up. That is, it did not clear the hold-down post before liftoff and was caught by the SRBs. This places an additional structural load on the vehicle that was not included in the original certification requirements. The Space Shuttle is currently being certified to withstand the loads induced by up to three (3) of eight (8) SRB hold-down experiencing a "hang-up". The results of loads analyses performed for (4) stud hang-ups indicate that the internal vehicle loads exceed current structural certification limits at several locations. To determine the risk to the vehicle from four (4) stud hang-ups, the likelihood of the scenario occurring must first be evaluated. Prior to the analysis discussed in this paper, the likelihood of occurrence had been estimated assuming that the stud hang-ups were completely independent events. That is, it was assumed that no common causes or factors existed between the individual stud hang-up events. A review of the data associated with the hang-up events, showed that a common factor (timing skew) was present. This paper summarizes a revised likelihood evaluation performed for the four (4) stud hang-ups case considering that there are common factors associated with the stud hang-ups. The results show that explicitly (i.e. not using standard common cause methodologies such as beta factor or Multiple Greek Letter modeling) taking into account the common factor of timing skew results in an increase in the estimated likelihood of four (4) stud hang-ups of an order of magnitude over the independent failure case.

Cross, Robert↗

Development and Testing of an Ultracapacitor Based Uninterruptible Power Supply (UPS) System

The NASA Glenn Research Center (GRC) initiated the development and testing of an ultracapacitor based uninterruptible power supply (UPS) system as a means to provide backup power for the many critical NASA applications. A UPS system typically utilizes batteries for energy storage. The battery is the most vulnerable part of the UPS system, requiring regular maintenance and replacement. Battery performance is also extremely temperature dependent. Ultracapacitors are ideal for UPS systems where long life, maintenance free operation, and excellent low temperature performance is essential. State of the art symmetric ultracapacitors were used for these tests. The ultracapacitors were interconnected in an innovative configuration to minimize interconnection impedance, and to provide voltage balancing. Ultracapacitors can be charged extremely rapidly and supply high current, which are essential characteristics for an effective UPS system. Charging ultracapacitors is significantly less complex than charging batteries since there is no chemical reaction occurring while charging ultracapacitors. The report concludes that the implementation of symmetric ultracapacitors in a UPS system can provide significant improvements in power system performance and reliability.

Eichenberg, Dennis J.↗

The role of corporate investment in start-ups for climate-tech innovation

Enabling and accelerating the full potential of energy innovation is a critical component of the global policy response to climate change. Incentivizing start-ups advancing climate-tech (i.e., products and services related to clean energy and climate change), has become central to innovation policy because start-ups are nimble (compared to incumbents), can quickly focus on bringing new technologies to market, and simultaneously create new jobs and catalyze local industries. Public policies to support climate-tech start-ups and efforts such as Mission Innovation tend to focus on increasing government spending (e.g., grants for research and development) or on creating demand pull for new technologies (e.g., feed-in-tariffs). But to go from research and development to widespread adoption of new products and services, start-ups need to grow and scale, and this requires support from private investors. Yet, research on how different investors can shape the direction of climate innovation—and how public policy can incentivize private investment in climate-tech start-ups to support the public good—is surprisingly sparse.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Network Control Center User Planning System (NCC UPS)

NCC UPS is presented in the form of the viewgraphs. The following subject areas are covered: UPS overview; NCC UPS role; major NCC UPS functional requirements; interactive user access levels; UPS interfaces; interactive user subsystem; interface navigation; scheduling screen hierarchy; interactive scheduling input panels; autogenerated schedule request panel; schedule data tabular display panel; schedule data graphic display panel; graphic scheduling aid design; and schedule data graphic display.

Dealy, Brian↗

Lithium-Ion UPS Battery Research and Commentary

Lithium-ion batteries are increasingly prevalent in a variety of devices both small and large. The high level of stored energy in UPS battery racks is closely scrutinized because sudden, uncontrolled release of chemical and electrical energy could be an ignition source. With this in mind, lithium-ion battery safety is the subject of several testing standards, including UL 1642, UL 1973, and UL 9540A.The motivation for this research and commentary is the potential installation of lithium-ion batteries in a Vertiv UPS assembly for one of the buildings on the ORNL campus. The battery modules Vertiv uses are compliant with abuse survival testing, demonstrating that cells and modules are rugged. The modules are further compliant with fire propagation requirements – in the event a failure does produce a fire, it doesn’t spread. Beyond these, the rack level assemblies Vertiv sources comply with UL requirements to contain a fire within the rack.This three-tiered approach to battery safety suggests Vertiv’s lithium-ion UPS battery racks can reasonably be considered for use in a facility with appropriate fire protection provisions and an informed emergency response team.

25 ENERGY STORAGE↗

Combined LAURA-UPS hypersonic solution procedure

A combined solution procedure for hypersonic flowfields around blunted slender bodies was implemented using a thin-layer Navier-Stokes code (LAURA) in the nose region and a parabolized Navier-Stokes code (UPS) on the after body region. Perfect gas, equilibrium air, and non-equilibrium air solutions to sharp cones and a sharp wedge were obtained using UPS alone as a preliminary step. Surface heating rates are presented for two slender bodies with blunted noses, having used LAURA to provide a starting solution to UPS downstream of the sonic line. These are an 8 deg sphere-cone in Mach 5, perfect gas, laminar flow at 0 and 4 deg angles of attack and the Reentry F body at Mach 20, 80,000 ft equilibrium gas conditions for 0 and 0.14 deg angles of attack. The results indicate that this procedure is a timely and accurate method for obtaining aerothermodynamic predictions on slender hypersonic vehicles.

Wood, William A.↗

Status Of The UPS Space-Marching Flow Solver

The status of the three-dimensional parabolized Navier-Stokes solver UPS is described. The UPS code, initiated at NASA Ames Research Center in 1986, continues to develop and evolve through application to supersonic and hypersonic flow fields. Hypersonic applications have motivated enhancement of the physical modeling capabilities of the code, specifically real gas modeling, boundary conditions, and turbulence and transition modeling. The UPS code has also been modified to enhance robustness and efficiency in order to be practically used in concert with an optimization code for supersonic transport design. These developments are briefly described along with some relevant results for generic test problems obtained during verification of the enhancements. Included developments and results have previously been published and widely disseminated domestically.

Lawerence, Scott L.↗

4D evolution of Cr 23 C 6 precipitates in neutron-irradiated and annealed HT-UPS steel observed via synchrotron micro-computed tomography

High-temperature-ultrafine precipitate strengthened (HT-UPS) steel is a potential structural material for advanced nuclear reactors; however, its irradiation response is not well understood. This research provides insight into irradiation-induced effects, such as precipitate evolution mechanisms and four-dimensional morphological evolution, in HT-UPS steel using synchrotron micro-computed tomography. Identical specimens were characterized pre-irradiation and post-irradiation following neutron exposure up to 0.3 displacements per atom at 600 °C. Irradiation effects were also differentiated from the annealing response of precipitates. Following neutron irradiation, the average Cr 23 C 6 precipitate size reduced, affected by the synergy of nucleation and growth, ballistic dissolution, and inverse coarsening, which was observed at fluences an order of magnitude lower than previously observed. Annealing at 600 °C for 32 h increased the average Cr 23 C 6 precipitate size and decreased the phase fraction, attributed to precipitate coarsening. The precipitate morphology evolution and resultant mechanisms can be utilized to parameterize and validate microstructural models simulating radiation damage or annealing.

36 MATERIALS SCIENCE↗

Analysis of GOES imagery and digitized data for the SEV-UPS period, August 1979

In support of the Southeastern Virginia Urban Plume Study (SEV-UPS), GOES satellite imagery was analyzed for the month of August 1979. The analyzed GOES images provide an additional source of meteorological input useful in the evaluation of air quality data collected during the month long period of the SEV-UPS experiment. In addition to the imagery analysis, GOES digitized data were analyzed for the period of August 6 to 11, during which a regional haze pattern was detectable in the imagery. The results of the study indicate that the observed haze patterns correspond closely with areas shown in surface based measurements to have reduced visibilities and elevated pollution levels. Moreover, the results of the analysis of digitized data indicate that digital reflectance counts can be directly related to haze intensity both over land and ocean. The model results agree closely with the observed GOES digital reflectance counts, providing further indication that satellite remote sensing can be a useful tool for monitoring regional elevated pollution episodes.

Bowley, C. J.↗

The equivalence between dislocation pile-ups and cracks

Cracks and dislocation pile-ups are equivalent to each other. In this paper, the physical equivalence between cracks and pile-ups is delineated, and the relationshps between crack-extension force, force on the leading dislocation, stress-intensity factor, and dislocation density are reviewed and summarized. These relations make it possible to extend quantitatively the recent advances in the concepts and practices of fracture mechanics to the studies of microfractures and microplastic deformations.

Liu, H. W.↗

Software for Start-Ups: Introducing the NASA in Silicon Valley

Ames is in the unique position to cater to tech companies and start-ups in California's Silicon Valley. The majority of Ames' technology transfer is software, which is very attractive to newly developing companies in the Valley as they create their business plans and develop their technology portfolio structures. Ames is collaborating with several "accelerators", "incubators" and academic technology transfer programs to connect start-ups with the space agency's technologies and software. The ultimate goal is to enable successful businesses by harnessing the unique resources of the Silicon Valley entrepreneurial ecosystem, AND beyond! Note: All info is in the public domain.

Williams, Kimberly↗

Materials Data on UPS by Materials Project

UPS is Matlockite structured and crystallizes in the tetragonal P4/nmm space group. The structure is three-dimensional. U5+ is bonded in a 9-coordinate geometry to four equivalent P3- and five equivalent S2- atoms. All U–P bond lengths are 2.90 Å. There are four shorter (2.75 Å) and one longer (2.86 Å) U–S bond lengths. P3- is bonded in a 8-coordinate geometry to four equivalent U5+ and four equivalent P3- atoms. All P–P bond lengths are 2.66 Å. S2- is bonded to five equivalent U5+ atoms to form a mixture of distorted edge and corner-sharing SU5 trigonal bipyramids.

36 MATERIALS SCIENCE↗

UPS XML Format and Data

This is the XML data and format for UPS supercomponent including subcomponents: Grid following inverter (GFL), Grid forming inverter (GFM), and dc-dc converter connected to the energy storage and the AI load.

Marthi, Phani Ratna Vanamali [ORNL] (ORCID:0000000↗

The study of high-frequency pick-ups for electron beam position measurements in the AWAKE common beamline

The common beamline of the AWAKE experiment at CERN involves the co-propagation of two particle beams: protons with 48 nC bunch charge and 250 ps bunch length, and electrons with up to 600 pC bunch charge and approximately 4 ps bunch length. The existing operational beam position monitors at AWAKE cannot measure the electron bunches whilst the more-intense proton bunches are present, due to their low operating frequency. In order to try to address this challenge, two different types of high-frequency pick-ups were studied, a conical-shaped button pick-up and a Cherenkov diffraction radiation-based pick-up designed to operate at around 30 GHz. Both devices were installed at AWAKE and were connected to two identical read-out systems designed by TRIUMF. This contribution presents and discusses the results obtained from beam-based measurements during the current experimental year.

43 PARTICLE ACCELERATORS↗