Search NASA⌕ Search

SEARCH · Search NASA

Results for “UPS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

City-level impacts of building tune-ups: Findings from Seattle's building tune-ups program

Many U.S. cities are implementing policies to reduce greenhouse gas (GHG) emissions of their buildings. These range from building energy benchmarking and disclosure to building performance standards (BPS) that require buildings to meet specific targets of energy use or emissions. The City of Seattle adopted a climate action plan in 2013 that set a goal of zero net GHG emissions in the road transportation, buildings, and waste sectors by 2050, with a number of near and long term actions. Seattle implemented mandatory building tune-ups in 2016, applying to commercial buildings larger than 50,000 sqft. Building tune-ups1 involve assessment and implementation of operational and maintenance (O + M) improvements to achieve energy and water efficiency, such as changes to thermostat set points or adjusting lighting or irrigation schedules. Seattle's tune-ups program covered 27 such improvements in HVAC, lighting, domestic hot water, and envelope systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The role of corporate investment in start-ups for climate-tech innovation

Enabling and accelerating the full potential of energy innovation is a critical component of the global policy response to climate change. Incentivizing start-ups advancing climate-tech (i.e., products and services related to clean energy and climate change), has become central to innovation policy because start-ups are nimble (compared to incumbents), can quickly focus on bringing new technologies to market, and simultaneously create new jobs and catalyze local industries. Public policies to support climate-tech start-ups and efforts such as Mission Innovation tend to focus on increasing government spending (e.g., grants for research and development) or on creating demand pull for new technologies (e.g., feed-in-tariffs). But to go from research and development to widespread adoption of new products and services, start-ups need to grow and scale, and this requires support from private investors. Yet, research on how different investors can shape the direction of climate innovation—and how public policy can incentivize private investment in climate-tech start-ups to support the public good—is surprisingly sparse.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

In-situ high-energy X-ray characterization of neutron irradiated HT-UPS stainless steel under tensile deformation

Here, the tensile deformation behavior of a high-temperature, ultrafine-precipitate strengthened (HT-UPS) stainless steel was characterized in-situ with high-energy X-ray diffraction at 20 and 400 °C. The HT-UPS samples were neutron irradiated to 3 dpa at 400 °C. Significant irradiation hardening and ductility loss were observed at both temperatures. Lattice strain evolutions of the irradiated samples showed a strong linear response up to near the onset of the macroscopic yield, in contrast to the unirradiated HT-UPS which showed a pronounced non-linear behavior well below the macroscopic yield. While the room temperature diffraction elastic moduli in the longitudinal direction increased after irradiation, the 400 degrees C moduli were similar before and after irradiation. The evolution of the {200} lattice strain parallel to the loading axis (ε L {200} ) showed unique characteristics: in the plastic regime, the evolution of (ε L {200} ) after yield is temperature-dependent in the unirradiated specimens but temperature-independent in the irradiated specimens; and the value of (ε L {200} ) at the yield is an irradiation-sensitive, temperature-independent . parameter. The evolution of (ε L {200} ) corresponds well with the dislocation density evolution, and is an effective probe of the deformation-induced long-range internal stresses in the HT-UPS steel.

36 MATERIALS SCIENCE↗

Economy and Emissions Impacts from Solazyme Fuel in UPS Delivery Vehicles

To improve understanding of the potential fuel economy and emissions impacts from switching a fleet of vehicles from conventional petroleum diesel to synthetic renewable diesel, the National Renewable Energy Laboratory (NREL) conducted fuel economy and emissions analyses at NREL's Renewable Fuels and Lubricants (ReFUEL) Laboratory. Representative test cycles were developed based on real-world data from six package delivery vehicles and six class 8 day-cab tractors operated by UPS in the Dallas, Texas, area. A three-week in-field data collection period yielded 170 days of real-world vehicle operations data that NREL used to select representative standard drive cycles for testing. Fuel economy and emissions tests at the ReFUEL Laboratory showed that, in general, when switching from conventional diesel to renewable diesel observed changes in tailpipe carbon dioxide (CO2), fuel consumption, and fuel economy are primarily driven by changes in fuel properties such as the hydrogen-to-carbon ratio, density, and lower heating value (LHV). The vehicles tested with the renewable diesel showed a consistent 4.2% reduction in tailpipe CO2 emissions, but a 3.5%-4.8% reduction in fuel economy compared with local pump diesel. This is consistent with the 4.2% lower volumetric LHV of the sourced renewable diesel compared to the pump diesel. The UPS package car tested on renewable diesel also demonstrated a 4.1% oxides of nitrogen (NOx) reduction. NOx emissions from the UPS selective-catalyst-reduction-equipped tractor were an order of magnitude lower than the package car but showed relatively higher variability in results from cycle to cycle.

33 ADVANCED PROPULSION SYSTEMS↗

Lithium-Ion UPS Battery Research and Commentary

Lithium-ion batteries are increasingly prevalent in a variety of devices both small and large. The high level of stored energy in UPS battery racks is closely scrutinized because sudden, uncontrolled release of chemical and electrical energy could be an ignition source. With this in mind, lithium-ion battery safety is the subject of several testing standards, including UL 1642, UL 1973, and UL 9540A.The motivation for this research and commentary is the potential installation of lithium-ion batteries in a Vertiv UPS assembly for one of the buildings on the ORNL campus. The battery modules Vertiv uses are compliant with abuse survival testing, demonstrating that cells and modules are rugged. The modules are further compliant with fire propagation requirements – in the event a failure does produce a fire, it doesn’t spread. Beyond these, the rack level assemblies Vertiv sources comply with UL requirements to contain a fire within the rack.This three-tiered approach to battery safety suggests Vertiv’s lithium-ion UPS battery racks can reasonably be considered for use in a facility with appropriate fire protection provisions and an informed emergency response team.

25 ENERGY STORAGE↗

Effects of neutron irradiation and post-irradiation annealing on the microstructure of HT-UPS stainless steel

Microstructural changes resulted from neutron irradiation and post-irradiation annealing in a high-temperature ultra-fine precipitate strengthened (HT-UPS) stainless steel were characterized using transmission electron microscopy (TEM) and atom probe tomography (APT). Three HT-UPS samples were neutron-irradiated to 3 dpa at 500 °C, and after irradiation, two of them were annealed for 1 h at 600 °C and 700 °C, respectively. Frank dislocation loops were the dominant defect structure in both the as-irradiated and 600 °C post-irradiation-annealed (PIAed) samples, and the loop sizes and densities were similar in these two samples. Unfaulted dislocation loops were observed in the 700 °C PIAed sample, and the loop density was greatly reduced in comparison with that in the as-irradiated sample. Nano-sized MX precipitates were observed under TEM in the 700 °C PIAed sample, but not in the 600 °C PIAed or the as-irradiated samples. The titanium-rich clusters were identified in all three samples using APT. The post-irradiation annealing (PIA) caused the growth of the Ti-rich clusters with a stronger effect at 700 °C than at 600 °C. The irradiation caused elemental segregations at the grain boundary and the grain interior, and the grain boundary segregation behavior is consistent with observations in other irradiated austenitic steels. Here, APT results showed that PIA reduced the magnitude of irradiation induced segregations.

36 MATERIALS SCIENCE↗

UPS: Unified PMU-Data Storage System to Enhance T+D PMU Data Usability

The emerging distribution-level phasor measurement unit (D-PMU) is expected to play an important role in enhancing distribution system observability and situational-awareness. It is a demanding yet challenging task to develop advanced D-PMU data management and analytics tools to improve D-PMU data usability and further promote D-PMU projects deployment. This paper focuses on D-PMU data processing and storage. It presents a brief review of existing D-PMU data storage systems and points out their limitations on high-performance, flexibility, and scalability. To overcome the limitations, a unified PMU-data storage system (UPS) is proposed. Specifically, a unified I/O interface between storage servers and computing jobs is developed to effectively reduce the overhead of managing various computing jobs and data analytics over multiple storage infrastructures; and PMUCache with PMUCache partitioning and PMUCache replacement algorithms are designed to support in-situ data processing and shared distributed data storage and further serve the computing jobs/queries with different Quality of Service (QoS) requirements. Through a series of experiments, it is demonstrated that UPS achieves high performance on fast and big data processing and storage, and efficiently increases the flexibility and scalability of PMU data management systems.

42 ENGINEERING↗

4D evolution of Cr 23 C 6 precipitates in neutron-irradiated and annealed HT-UPS steel observed via synchrotron micro-computed tomography

High-temperature-ultrafine precipitate strengthened (HT-UPS) steel is a potential structural material for advanced nuclear reactors; however, its irradiation response is not well understood. This research provides insight into irradiation-induced effects, such as precipitate evolution mechanisms and four-dimensional morphological evolution, in HT-UPS steel using synchrotron micro-computed tomography. Identical specimens were characterized pre-irradiation and post-irradiation following neutron exposure up to 0.3 displacements per atom at 600 °C. Irradiation effects were also differentiated from the annealing response of precipitates. Following neutron irradiation, the average Cr 23 C 6 precipitate size reduced, affected by the synergy of nucleation and growth, ballistic dissolution, and inverse coarsening, which was observed at fluences an order of magnitude lower than previously observed. Annealing at 600 °C for 32 h increased the average Cr 23 C 6 precipitate size and decreased the phase fraction, attributed to precipitate coarsening. The precipitate morphology evolution and resultant mechanisms can be utilized to parameterize and validate microstructural models simulating radiation damage or annealing.

36 MATERIALS SCIENCE↗

Materials Data on UPS by Materials Project

UPS is Matlockite structured and crystallizes in the tetragonal P4/nmm space group. The structure is three-dimensional. U5+ is bonded in a 9-coordinate geometry to four equivalent P3- and five equivalent S2- atoms. All U–P bond lengths are 2.90 Å. There are four shorter (2.75 Å) and one longer (2.86 Å) U–S bond lengths. P3- is bonded in a 8-coordinate geometry to four equivalent U5+ and four equivalent P3- atoms. All P–P bond lengths are 2.66 Å. S2- is bonded to five equivalent U5+ atoms to form a mixture of distorted edge and corner-sharing SU5 trigonal bipyramids.

36 MATERIALS SCIENCE↗

Eighteen-Month Final Evaluation of UPS Second Generation Diesel Hybrid-Electric Delivery Vans

A parallel hybrid-electric diesel delivery van propulsion system was evaluated at a UPS facility in Minneapolis using on-vehicle data logging, fueling, and maintenance records. Route and drive cycle analysis showed different duty cycles for hybrid vs. conventional delivery vans; routes were switched between the study groups to provide a valid comparison. The hybrids demonstrated greater advantage on the more urban routes; the initial conventional vans' routes had less dense delivery zones. The fuel economy of the hybrids on the original conventional group's routes was 10.4 mpg vs. 9.2 mpg for the conventional group on those routes a year earlier. The hybrid group's fuel economy on the original hybrid route assignments was 9.4 mpg vs. 7.9 mpg for the conventional group on those routes a year later. There was no statistically significant difference in total maintenance cost per mile or for the vehicle total cost of operation per mile. Propulsion-related maintenance cost per mile was 77% higher for the hybrids, but only 52% more on a cost-per-delivery-day basis. Laboratory dynamometer testing demonstrated 13%-36% hybrid fuel economy improvement, depending on duty cycle, and up toa 45% improvement in ton-mi/gal. NO x emissions increased 21%-49% for the hybrids in laboratory testing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling the Control Systems of Gas-Turbines to Ensure Their Reliable Parallel Operation in the UPS of Russia

Consideration is given to different approaches to modeling the control systems of gas turbines as a component of CCPP and GTPP to ensure their reliable parallel operation in the UPS of Russia. The disadvantages of the approaches to the modeling of combined-cycle units in studying long-term electromechanical transients accompanied by power imbalance are pointed out. Examples are presented to support the use of more detailed models of gas turbines in electromechanical transient calculations. It is shown that the modern speed control systems of gas turbines in combination with relatively low equivalent inertia have a considerable effect on electromechanical transients, including those caused by disturbances not related to power imbalance.

42 ENGINEERING↗

Engineering and manufacturing of ITER first mirror mock-ups

Most of the ITER optical diagnostics aiming at viewing and monitoring plasma facing components will use in-vessel metallic mirrors. These mirrors will be exposed to a severe plasma environment and lead to an important tradeoff on their design and manufacturing. As a consequence, investigations are carried out on diagnostic mirrors toward the development of optimal and reliable solutions. The goals are to assess the manufacturing feasibility of the mirror coatings, evaluate the manufacturing capability and associated performances for the mirrors cooling and polishing, and finally determine the costs and delivery time of the first prototypes with a diameter of 200 and 500 mm. Three kinds of ITER candidate mock-ups are being designed and manufactured: rhodium films on stainless steel substrate, molybdenum on TZM substrate, and silver films on stainless steel substrate. The status of the project is presented in this paper.

36 MATERIALS SCIENCE↗

Validation of the Electrical Properties of the ITER ICRF Antenna using Reduced-Scale Mock-Ups

Experimental measurements on reduced-scale mock-ups allow validating the electrical properties and RF numerical optimization of the ITER ICRF antenna. Frequency response in the different regions of the antenna is described and key parameters for performance improvement are given. Coupling is improved by acting on the front-face geometry (strap width, antenna box depth and vertical septa recess). The 4-port junction acts as a frequency filter and together with the service stub performs pre-matching in the whole frequency band. Influence of the Faraday screen on coupling is limited. The effect of voltage limitation on the maximum total radiated power is given. The importance of a good decoupling network and of grounding is emphasized. Finally the control of the antenna wave spectrum is performed by implementing feedback controlled load-resilient matching and decoupling options and control algorithms are tested.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

UPS XML Format and Data

This is the XML data and format for UPS supercomponent including subcomponents: Grid following inverter (GFL), Grid forming inverter (GFM), and dc-dc converter connected to the energy storage and the AI load.

Marthi, Phani Ratna Vanamali [ORNL] (ORCID:0000000↗