Search NASA⌕ Search

SEARCH · Search NASA

Results for “UV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Estimating UV-B, UV-Erithemic, and UV-A Irradiances From Global Horizontal Irradiance and MERRA-2 Ozone Column Information

The ground ultraviolet (UV) solar radiation is relevant due to its impacts on plastics degradation (mainly UVA) and on human health (UVB and erithemic UV (UVE)). UV ground measurements are not as ubiquitous as the relatively common global horizontal irradiance (GHI) measurements. Three simple models that estimate the UVA, UVB, and UVE components of solar irradiance from GHI and ozone column information are locally adjusted and validated. Five one-minute datasets from three sites in southeastern South America and two in the United States are used for simultaneous solar irradiance and UV data. All sites correspond to temperate mid-latitude regions. Simultaneous atmospheric total ozone column information is obtained from the reanalysis modern-era retrospective analysis for research and applications (MERRA-2) database for each site. Aside from locally adjusted models, average models with a single set of coefficients are also evaluated. For instance, the best average model is able to estimate UVE with a typical uncertainty below 12% and mean biases between +-3%, relative to the average of the measurements. Similar results are reported for the UVB and UVA components. These results, which can be useful in regions with similar climate and geography, provide a simple way to estimate UV irradiance under all-sky conditions with known uncertainty. This is an alternative to global satellite-based UV estimates, which can have high uncertainties at specific locations. Because MERRA-2 information has a global coverage, when coupled with good satellite-based estimates for GHI, UV irradiances can be estimated by this method over a large territory.

environmental UV radiation↗

UV-Resistant Microbes and UV-Blocking Microbial Extract

The present disclosure relates to a composition including an extract from an Acidithiobacillus bacteria or a yeast extracted after exposure of the bacteria to UV radiation. The disclosure further relates to a method of preparing a UV-blocking composition by exposing a culture of Acidithiobacillus or yeast to UV radiation and extracting UV-blocking cellular material produced in response to the UV radiation from the Acidithiobacillus or yeast. The disclosure further relates to a method of protecting an item from UV radiation damage by extracting UV-blocking cellular material from Acidithiobacillus or yeast exposed to UV radiation and covering the item with the UV-blocking cellular material. The disclosure further relates to a UV-resistant yeast cell and a UV-resistant bacterial cell.

Cuero, Raul G.↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report (DOE 2023) provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

42 ENGINEERING↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating efficacy of different UV-stabilizers/absorbers in reducing UV-degradation of lignin

Abstract Susceptibility of wood to UV degradation decreases the service life of wood products outdoors. Organic UV absorbers (UVAs) and hindered amine light stabilizers (HALSs), as well as inorganic UVAs, are added to coatings to improve the UV stability of coated-wood products. Although about 85% of UV radiation is absorbed by lignin in the wood, it is unclear which UV stabilizers can minimize lignin degradation. In this study, the photodegradation of softwood organosolv lignin was monitored over 35 days of UV exposure. Changes in lignin properties were assessed using Fourier transform infrared spectroscopy (FTIR), differential scanning calorimetry (DSC), gel permeation chromatography (GPC), and phosphorus-31 nuclear magnetic resonance spectroscopy ( 31 P NMR). It was found that the aromatic rings of lignin underwent significant degradation, resulting in increased glass transition temperature and molecular weight of lignin. Subsequently, 18 different additives were mixed with lignin and exposed to UV irradiation. The analysis of samples before and after UV exposure with FTIR revealed that inorganic UVAs (cerium oxide and zinc oxide) and a mixture of organic UVAs and HALSs (T-479/T-292, T-5248, and T-5333) were the most effective additives in reducing lignin degradation. This study can help coating scientists to formulate more durable transparent exterior wood coatings.

36 MATERIALS SCIENCE↗

Galaxy morphologies revealed with Subaru HSC and super-resolution techniques. I. Major merger fractions of L UV ∼ 3–15 L*UV dropout galaxies at z ∼ 4–7

Abstract We perform a super-resolution analysis of the Subaru Hyper Suprime-Cam (HSC) images to estimate the major merger fractions of z ∼ 4–7 dropout galaxies at the bright end of galaxy UV luminosity functions (LFs). Our super-resolution technique improves the spatial resolution of the ground-based HSC images, from ∼1″ to $\lesssim \!\!{0{^{\prime \prime }_{.}}1}$, which is comparable to that of the Hubble Space Telescope, allowing us to identify z ∼ 4–7 bright major mergers at a high completeness value of $\gtrsim \!\!90\%$. We apply the super-resolution technique to 6412, 16, 94, and 13 very bright dropout galaxies at z ∼ 4, 5, 6, and 7, respectively, in a UV luminosity range of LUV ∼ 3–$15\, L_{\rm UV}^*$ corresponding to −24 ≲ MUV ≲ −22. The major merger fractions are estimated to be $f_{\rm merger}\sim 10\%$–$20\%$ at z ∼ 4 and $\sim 50\%$–$70\%$ at z ∼ 5–7, which shows no fmerger difference compared to those of a control faint galaxy sample. Based on the fmerger estimates, we verify contributions of source blending effects and major mergers to the bright-end of double power-law (DPL) shape of z ∼ 4–7 galaxy UV LFs. While these two effects partly explain the DPL shape at LUV ∼ 3–$10\, L_{\rm UV}^*$, the DPL shape cannot be explained at the very bright end of $L_{\rm UV}\gtrsim 10\, L_{\rm UV}^*$, even after the AGN contribution is subtracted. The results support scenarios in which other additional mechanisms such as insignificant mass quenching and low dust obscuration contribute to the DPL shape of galaxy UV LFs.

Shibuya, Takatoshi↗

Comparisons Between Ground Measurements of Broadband UV Irradiance (300-380 nm) and TOMS UV Estimates at Moscow for 1979-2000

We show the comparisons between ground-based measurements of spectrally integrated (300 nm to 380 nm) ultraviolet (UV) irradiance with satellite estimates from the Total Ozone Mapping Spectrometer (TOMS) total ozone and reflectivity data for the whole period of TOMS measurements (1979-2000) over the Meteorological Observatory of Moscow State University (MO MSU), Moscow, Russia. Several aspects of the comparisons are analyzed, including effects of cloudiness, aerosol, and snow cover. Special emphasis is given to the effect of different spatial and temporal averaging of ground-based data when comparing with low-resolution satellite measurements (TOMS footprint area 50-200 sq km). The comparisons in cloudless scenes with different aerosol loading have revealed TOMS irradiance overestimates from +5% to +20%. A-posteriori correction of the TOMS data accounting for boundary layer aerosol absorption (single scattering albedo of 0.92) eliminates the bias for cloud-free conditions. The single scattering albedo was independently verified using CIMEL sun and sky-radiance measurements at MO MSU in September 2001. The mean relative difference between TOMS UV estimates and ground UV measurements mainly lies within 1 10% for both snow-free and snow period with a tendency to TOMS overestimation in snow-free period especially at overcast conditions when the positive bias reaches 15-17%. The analysis of interannual UV variations shows quite similar behavior for both TOMS and ground measurements (correlation coefficient r=0.8). No long-term trend in the annual mean bias was found for both clear-sky and all-sky conditions with snow and without snow. Both TOMS and ground data show positive trend in UV irradiance between 1979 and 2000. The UV trend is attributed to decreases in both cloudiness and aerosol optical thickness during the late 1990's over Moscow region. However, if the analyzed period is extended to include pre-TOMS era (1968-2000 period), no trend in ground UV irradiance is detected.

Yurova, Alla Y.↗

The solar UV environment and bacterial spore UV resistance: considerations for Earth-to-Mars transport by natural processes and human spaceflight

The environment in space and on planets such as Mars can be lethal to microorganisms because of the high vacuum and high solar radiation flux, in particular UV radiation, in such environments. Spores of various Bacillus species are among the organisms most resistant to the lethal effects of high vacuum and UV radiation, and as a consequence are of major concern for planetary contamination via unmanned spacecraft or even natural processes. This review focuses on the spores of various Bacillus species: (i) their mechanisms of UV resistance; (ii) their survival in unmanned spacecraft, space flight and simulated space flight and Martian conditions; (iii) the UV flux in space and on Mars; (iv) factors affecting spore survival in such high UV flux environments.

Review↗

UV-Enabled Defect Engineering in Multilayer GaSe and InSe and UV Writing of the Grating Pattern

III–VI post-transition-metal chalcogenides are layered semiconductor materials that exhibit direct band gaps in multilayers. Defect engineering is essential in 2D layered semiconductors for functional devices. Here, in this work, we report defect engineering in multilayer gallium selenide (GaSe) and indium selenide (InSe), where defects generated by ultraviolet (UV, 325 nm) laser irradiation result in an additional photoluminescence (PL) line. The additional PL line is due to defect-bound excitons. Characteristics of the defect emission are similar in GaSe and InSe samples subjected to UV irradiation, air annealing, and hydrostatic pressure. Two-beam UV interference was applied to create grating patterns with a periodic array of low and high densities of defects in GaSe. Density functional theory has identified the defect type in GaSe. The results provide valuable insights into defect generation and UV scribing of photonic circuits in 2D Se-based multilayers for optical integration in a 2D platform.

2D multilayered materials↗

Correlations between optical/near-infrared and UV extinction parameters and the prediction of UV extinction from ground-based photometry

An analysis of the variability of absolute UV extinction, A lambda derived through the ratio total-to-selective extinction, R Av/E(B-V), for 31 lines of sight for which UV extinction parameters were derived, is presented. For these data, which sample a wide range of environments and which are characterized by R = 2.5 to 6.0, differences in the shapes of UV extinction curves are largely due to variations in optical/near-UV extinction through changes in R. From this, it is found that UV extinction curves can be reproduced with reasonable accuracy by simply knowing R. Detection of an A2175/E(B-V) = 10 + or - 1 mag implies that the total extinction at 2175 A can be estimated from E(B-V) alone.

Cardelli, Jason A.↗

Simultaneous UV and X-ray Spectroscopy of the Seyfert 1 Galaxy NGC 5548. I: Physical Conditions in the UV Absorbers

We present new UV spectra of the nucleus of the Seyfert 1 galaxy NGC 5548, which we obtained with the Space Telescope Imaging Spectrograph at high spectral resolution, in conjunction with simultaneous Chandra X-ray Observatory spectra. Taking advantage of the low UV continuum and broad emission-line fluxes, we have determined that the deepest UV absorption component covers at least a portion of the inner, high-ionization narrow-line region (NLR). We find nonunity covering factors in the cores of several kinematic components, which increase the column density measurements of N V and C IV by factors of 1.2 to 1.9 over the full-covering case; however, the revised columns have only a minor effect on the parameters derived from our photoionization models. For the first time, we have simultaneous N V and C IV columns for component 1 (at -1040 km/s), and find that this component cannot be an X-ray warm absorber, contrary to our previous claim based on nonsimultaneous observations. We find that models of the absorbers based on solar abundances severely overpredict the O VI columns previously obtained with the Far Ultraviolet Spectrograph, and present arguments that this is not likely due to variability. However, models that include either enhanced nitrogen (twice solar) or dust, with strong depletion of carbon in either case, are successful in matching all of the observed ionic columns. These models result in substantially lower ionization parameters and total column densities compared to dust-free solar-abundance models, and produce little O VII or O VIII, indicating that none of the UV absorbers are X-ray warm absorbers.

Crenshaw, D. M.↗

GALEX Study of the UV Variability of Nearby Galaxies and a Deep Probe of the UV Luminosity Function

The proposal has two aims - a deep exposure of NGC 300, about a factor of 10 deeper than the GALEX all-sky survey; and an examination of the UV variability. The data were received just prior to a series of proposal deadlines in early spring. A subsequent analysis delay includes a move from SAO to the University of Texas - San Antonio. Nevertheless, we have merged the data into a single deep exposure as well as undertaking a preliminary examination of the variability. No UV halo is present as detected in the GALEX observation of M83. No UV bursts are visible; however a more stringent limit will only be obtained through a differencing of the sub-images. Papers: we expect 2 papers at about 12 pages/paper to flow from this project. The first paper will report on the time variability while the second will focus on the deep UV image obtained from stacking the individual observations.

Schlegel, Eric↗

Investigation of AlGaN-Delta–GaN-Based UV Photodiodes in a Metal–Semiconductor–Metal Configuration for Efficient and Fast Solar Blind UV Sensing

Metal–semiconductor–metal (MSM) configured UV photodiodes (PD’s) were designed and fabricated on an AlGaN/GaN–based substrate for efficient and ultrafast UV detection. The purpose was to investigate the feasibility of obtaining efficient and ultrafast temporal response from these devices in the UV given the challenges associated with the formation of Schottky contacts on laterally oriented AlGaN/GaN thin films. Two sets of devices were implemented using Pt and Au as metal contacts with 5-µm finger width, 5-µm finger spacing, and a 50-µm x 50-µm active area. Spectral and voltage bias studies were done to establish the spectral profile and the effect of bias voltage on the responsivity of the detectors at 265 nm. Here, the best vertical MSM PD’s produced 0.6-A/W responsivity under 10-V bias voltage at 265 nm. Peak spectral responsivities were recorded as 1.35 A/W and 1.25 A/W at 240 nm for Pt and Au PD’s, respectively.

42 ENGINEERING↗

UV testing of solar cells: Effects of antireflective coating, prior irradiation, and UV source

Short-circuit current degradation of electron irradiated double-layer antireflective-coated cells after 3000 hours ultraviolet (UV) exposure exceeds 3 percent; extrapolation of the data to 10(exp 5) hours (11.4 yrs.) gives a degradation that exceeds 10 percent. Significant qualitative and quantitative differences in degradation were observed in cells with double- and single-layer antireflective coatings. The effects of UV-source age were observed and corrections were made to the data. An additional degradation mechanism was identified that occurs only in previously electron-irradiated solar cells since identical unirradiated cells degrade to only 6 +/- 3 percent when extrapolated 10(exp 5) hours of UV illumination.

Meulenberg, A.↗