Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ultra-stable laser”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Progress toward ultra-stable lasers for use in space

This is a summary of a research project that has come to be known as SUNLITE, initially standing for Stanford University - NASA laser in space technology experiment. It involves scientists from the NASA Langley Research Center (LaRC), Stanford University, the National Institute of Standards and Technology (NIST), and the Joint Institute for Laboratory Astrophysics (JILA), and a growing number of other institutions. The long range objective of the SUNLITE effort is to examine the fundamental linewidth and frequency stability limits of an actively stabilized laser oscillator in the microgravity and vibration-free environment of space. The ground-based SUNLITE activities supporting that objective will develop a space-qualified, self-contained and completely automated terahertz oscillator stabilized to a linewidth of less than 3 Hz, along with a measurement system capable of determining laser linewidth to one part in 10(exp 16). The purpose of this paper is to discuss the critical technologies needed to place stabilized lasers in space and to describe the progress made by the SUNLITE project to develop these technologies.

Buoncristiani, A. M.↗

Noise in laser oscillator systems

The aim of the SUNLITE program is to demonstrate the performance of ultra-stable laser systems in the environment of space. The program uses Non-Planar Ring Oscillators (NPRO) which have shown great promise for time and frequency standards with unprecedented resolution and stability. An immediate goal is to test NPRO oscillators in orbital free fall by 1994. During the past year there was remarkable progress in the design and pre-flight testing of the SUNLITE test package. Current theoretical studies are investigating the possible effects of various noise sources on the linewidth and linecenter frequency stability of servocontrolled NPRO lasers. The frequency control system is reviewed and the potential impact on frequency stability of noise sources in the control system and in the environment is considered.

Hafele, Joseph C.↗

Laser Metrology for Ultra-Stable Space-Based Coronographs

Sensing starlight rejected from a coronagraph is essential in stabilizing the telescope pointing and wavefront drift, but performance is degraded for dim stars. Laser Metrology (MET) provides a different, complementary sensing method, one that can be used to measure changes in the alignment of the optics at high bandwidth, independent of the magnitude of the host star. Laser metrology measures changes in the separation of optical fiducial pairs, which can be separated by many meters. The principle of operations is similar to the laser metrology system used in LISA-Pathfinder to measure the in-orbit displacement between two test masses to a precision of ~10 picometers. In closed loop with actuators, MET actively maintains rigid body alignment of the front-end optics, thereby eliminating the dominant source of wavefront drift. In the case of a segmented, active primary mirror, MET provides six degrees of freedom sensing, replacing edge sensors. MET maintains wavefront control even during attitude maneuvers, such as slews between target stars, thereby avoiding the need to repeat time-consuming speckle suppression. These features can significantly improve the performance and observational efficiency of future large-aperture space telescopes equipped with internal coronagraphs. We evaluate MET trusses for various proposed monolithic and segmented space-based coronagraphs and present the performance requirements necessary to maintain contrast drift below 10^-11.

Moore, Dustin↗

Laser frequency stabilization for LISA

The requirement on laser frequency noise in the Laser Interferometer Space Antenna (LISA) depends on the velocity and our knowledge of the position of each spacecraft of the interferometer. Currently it is assumed that the lasers must have a pre-stabilized frequency stability of 30Hz/square root of Hz over LISA'S most sensitive frequency band (3 mHz - 30 mHz). The intrinsic frequency stability of even the most stable com- mercial lasers is several orders of magnitude above this level. Therefore it is necessary to stabilize the laser frequency to an ultra-stable frequency reference which meets the LISA requirements. The baseline frequency reference for the LISA lasers are high finesse optical cavities based on ULE spacers. We measured the stability of two ULE spacer cavities with respect to each other. Our current best results show a noise floor at, or below, 30 Hz/square root of Hz above 3 mHz. In this report we describe the experimental layout of the entire experiment and discuss the limiting noise sources.

Mueller, Guido↗

Thermal design and test results for SUNLITE ultra-stable reference cavity

SUNLITE (Stanford University-NASA Laser In-Space Technology Experiment) is a space-based experiment which uses a reference cavity to provide a stable frequency reference for a terahertz laser oscillator. Thermal stability of the cavity is a key factor in attaining a stable narrow-linewidth laser beam. The mount which is used to support and align the cavity will provide thermal isolation from the environment. The baseline requirement for thermal stability of the cavity is 0.025 C/min, but the design is directed toward achieving stability well beyond this requirement to improve the science data gained. A prototype of the cavity mount was fabricated and tested to characterize the thermal performance. The thermal vacuum test involved stable high-resolution temperature measurements and stable baseplate temperature control over long durations. Based on test data, the cavity mount design satisfies the severe requirement for the cavity thermal stability.

Amundsen, Ruth M.↗

Laser Frequency Stabilization for GRACE-II

The GRACE mission monitors changes in the Earth's gravity field by measuring changes in the distance between spacecraft induced by that changing field. The distance variation is measured with a microwave ranging system with sub-micron accuracy. The ranging measurement accuracy is limited by the signal-to-noise ratio and by the frequency stability of the microwave signal referenced to an ultra-stable oscillator (USO). For GRACE-2 a laser ranging system is envisioned with accuracy better than the GRACE microwave ranging system. A laser ranging system easily provides an improved signal-to-noise ratio over the microwave system. Laser frequency stability better than the GRACE USO stability has been demonstrated in several laboratories using thermally stabilized optical cavities. We are developing a space-qualifiable optical cavity and associated optics and electronics for use on GRACE-2 to provide a stable frequency reference for the laser ranging system. Two breadboard units have been developed and tested for performance and ability to survive launch and orbit environments. A prototype unit is being designed using lessons learned from tests of the breadboard units.

Earth gravity↗

Generation of 369.4 nm Radiation by Efficient Doubling of a Diode Laser

The trapped ytterbium ion frequency standard under development at JPL is designed to supply ultra-stable reference signals to be used in spacecraft tests of general relativity and other science experiments. Only diode lasers meet the requirements of low power comsumption and small size for use aboard spacecraft, but diode lasers are not currently available at 369.4 nm wavelength. It is therefore necessary to employ frequency doubling methods to reach this frequency with diode lasers. Here we present the characteristics of the resonant cavity doubling system we have designed and preliminary UV conversion results.

ultra-stable↗

Injection Locking of Gigahertz‐Frequency Surface Acoustic Wave Phononic Crystal Oscillator

Low-noise gigahertz (GHz) frequency sources are essential for applications in signal processing, sensing, and telecommunications. Surface acoustic wave (SAW) resonator-based oscillators offer compact form factors and low-phase noise due to their short mechanical wavelengths and high-quality (Q) factors. However, their small footprint makes them vulnerable to environmental variation, resulting in their poor long-term frequency stability. Injection locking is widely used to suppress frequency drift of lasers and oscillators by synchronizing to an ultra-stable reference. Here, injection locking of a 1-GHz SAW phononic-crystal oscillator is demonstrated, achieving 40-dB phase noise reduction at low offset frequencies and unperturbed low noise at large offset frequencies. Compared to a free-running SAW oscillator, which typically exhibits frequency drifts of several hundred hertz over minutes, the injection-locked oscillator reduces the frequency deviation to below 0.35 Hz. The locking range and oscillator dynamics is also investigated in the injection pulling region. The demonstrated injection-locked SAW oscillator could find applications in high-performance portable telecommunications and sensing systems.

injection locking↗

Ultra-Stable Beacon Source for Laboratory Testing of Optical Tracking

The ultra-stable beacon source (USBS) provides a laser-beam output with a very low angular jitter and can be used as an absolute angular reference to simulate a beacon in the laboratory. The laser is mounted on the top of a very short (approximately equal to 1 m) inverted pendulum (IP) with its optical axis parallel to the carbon fiber pendulum leg. The 85-cm, carbon fiber rods making up the leg are very lightweight and rigid, and are supported by a flex-joint at the bottom (see figure). The gimbal-mounted laser is a weight-adjustable load of about 1.5 kg with its center of rotation co-located with the center of percussion of the inverted pendulum. This reduces the coupling of transverse motion at the base of the pendulum to angular motion of the laser at the top. The inverted pendulum is mounted on a gimbal with its center of rotation coinciding with the pivot position of the inverted pendulum flexure joint. This reduces coupling of ground tilt at the inverted pendulum base to motion of the laser mounted at the top. The mass of the top gimbal is adjusted to give the pendulum a very low resonant frequency (approximately equal to 10 mHz) that filters transverse seismic disturbances from the ground where the base is attached. The motion of the IP is monitored by an optical-lever sensor. The laser light is reflected by the mirror on the IP, and then is detected by a quadrant photo-detector (QPD). The position of the beam spot on the QPD corresponds to the tilt of the IP. Damping of this motion is provided by two coil and magnet pairs. The bottom gimbal mount consists of two plates. The IP is mounted on the second plate. The first plate is supported by two posts through needles and can be rotated about the axis connecting the tips of the needles. The second plate hangs from the first plate and can be rotated about the axis perpendicular to the first plate. As a result, the second plate acts as a two-axis rotation stage. Its center of rotation is located at the effective bending point of the flex-joint. The second plate is pressed against two screw actuators by the weight of the IP. The screw actuators are orthogonal to each other and are used to adjust the inclination of the second plate. The actuators are driven by stepper motors. The whole IP system is housed in a box made of Lexan plastic plates to provide isolation from air currents and temperature variations. The signals from the sensors are processed and recorded with a PC using the xPC Target realtime environment of Math- Works. The control algorithms are written using the Simulink package from The MathWorks.

Aso, Yoichi↗

The role of time and speed in NASA's SUNLITE program

The SUNLITE program of NASA's LaRC aims to demonstrate lower noise and better frequency stability for continuous-wave (CW) solid-state lasers in the microgravity environment of space. The program will utilize laser-diode-pumped nonplanar-ring oscillators regulated by ultra-stable high-finesse Fabry-Perot Spectrometers to produce light beams with phase rate or frequency variations as low as 3 Hz. SUNLITE will use the period-method (P-method) to measure the phase rate and frequency stability of the lasers. The P-method was chosen because it requires less memory space for the raw data, because frequencies can be analyzed on-line in real-time simply by reciprocating the periods (fi = 1/pi), and because the mean and variance of the frequencies can be calculated as fast or faster than they can be with the fastest fast Fourier transformations. Furthermore, for a given signal-to-noise power ratio, the P-method requires less data and less computer time to extract the noise components. Although the P-method does require fast Time Interval Counters, the Fourier transformation method requires comparably fast Sampling Volt meters. For either method, however, time and computer speed play a critical role.

Hafele, Joseph C.↗

Prospects for Ultra-Stable Timekeeping with Sealed Vacuum Operation in Multi-Pole Linear Ion Trap Standards

A recent long-term comparison between the compensated multi-pole Linear Ion Trap Standard (LITS) and the laser-cooled primary standards via GPS carrier phase time transfer showed a deviation of less than 2.7x10(exp -17)/day. A subsequent evaluation of potential drift contributors in the LITS showed that the leading candidates are fluctuations in background gases and the neon buffer gas. The current vacuum system employs a "flow-through" turbomolecular pump and a diaphragm fore pump. Here we consider the viability of a "sealed" vacuum system pumped by a non-evaporable getter for long-term ultra-stable clock operation. Initial tests suggests that both further stability improvement and longer mean-time-between-maintenance can be achieved using this approach

timekeeping stability↗

Free-Flying Magnetometer Data System

The Free-Flying Magnetometer (FFM) is an autonomous "sensorcraft" developed at the Jet Propulsion Laboratory (JPL) for the Enstrophy sounding rocket mission. This mission was a collaborative project between the University of New Hampshire, Cornell University and JPL. The science goal of the mission was the study of current filamentation phenomena in the northern auroral region through multipoint measurements of magnetic field. The technical objective of the mission was the proof of concept of the JPL FFM design and the demonstration of an in-situ multipoint measurement technique employing many free-flying spacecraft. Four FFMs were successfully deployed from a sounding rocket launched from Poker Flats, Alaska on February 11, 1999. These hockey-puck-sized (80 mm diameter, 38 mm. height, 250 gram mass) free flyers each carry a miniature 3-axis flux-gate magnetometer that output +/- 2 V signals corresponding to a +/- 60,000 nT measurement range for each axis. The FFM uses a synchronized four-channel Sigma(Delta) Analog-to-Digital Converter (ADC) having a dynamic range of +/- 2.5V and converting at a rate of 279 samples/second/channel. Three channels are used to digitize the magnetometer signals to 17-bit (1.144 nT/bit) resolution. The fourth ADC channel is multiplexed for system monitoring of four temperature sensors and two battery voltages. The FFM also contains two sun sensors, a laser diode which emits a fan-shaped beam, a miniature S-band transmitter for direct communication to the ground station antennas, an ultra-stable Temperature Compensated Crystal Oscillator (TCXO) clock, an integrated data subsystem implemented in a Field-Programmable Gate Array (FPGA), a 4 Mbit Static Random Access Memory (SRAM) for data storage and Lithium Thionyl Chloride batteries for power. Communicating commands to the FFM prior to deployment is achieved with an infrared (IR) link. The FFM IR receiver responds to 9-bit pulse coded signals that are generated by an IR Light Emitting Diode (LED) in the payload for turning FFM power on or off and placing the FFM in a test mode or flight mode. The IR links are also used to synchronize (zero) the clocks onboard all the FFMs through a reset pulse originating from the payload GPS receiver that is issued when the FFMs are in flight mode. The FPGA based data subsystem manages continuous data collection from the four ADC channels and sun sensors, formatting and storing the data to SRAM, and controlling downlink transmission. The transmitter is powered only after a 2547 frame SRAM buffer has been filled (approx. 5 minutes of data). The data is Viterbi encoded and sent to the S-band transmitter via a First-In-First-Out (FIFO) buffer who's output is clocked at 100 bits/second. After the 26-second transmission, the transmitter is turned off to reduce noise coupling to the sensitive magnetometer. The data subsystem control consists of a master state machine that performs data flow management and is interfaced through a prioritized interrupt scheme to state machines that service the ADC, sun sensors and transmitter FIFO. Continuous data collection prevents the missing of data during transmission and provides implicit time tagging of the data acquired by the ADC because of synchronization with the TCXO clock.

Blaes, B.↗

Swept Frequency Laser Metrology System

A swept frequency laser ranging system having sub-micron accuracy that employs multiple common-path heterodyne interferometers, one coupled to a calibrated delay-line for use as an absolute reference for the ranging system. An exemplary embodiment uses two laser heterodyne interferometers to create two laser beams at two different frequencies to measure distance and motions of target(s). Heterodyne fringes generated from reflections off a reference fiducial X(sub R) and measurement (or target) fiducial X(sub M) are reflected back and are then detected by photodiodes. The measured phase changes Delta phi(sub R) and Delta phi (sub m) resulting from the laser frequency swept gives target position. The reference delay-line is the only absolute reference needed in the metrology system and this provides an ultra-stable reference and simple/economical system.

Zhao, Feng↗

NASA Astrophysics Technology Gaps, Prioritization, and Development

Physics of the Cosmos (PCOS) X-ray astrophysics: grazing-angle mirrors, optical blocking filters, fast event ID, gratings, micro-calorimeters, radiation-tolerant detectorsGravitational-wave astrophysics: phase measurement system, micro-Newton thrusters, non-contact charge-management system, stable laser system, low-stray-light telescope Cosmic Microwave Background (CMB): superconducting FPAs and optical elements (cryo filters and coatings)Cosmic Origins (COR)UV/Optical/IR: Next-gen detectors, ultra-stable high-precision telescope systems (including mirrors, thermal control, structures, metrology, etc.), and advanced UV coatingsFar-IR: Heterodyne detectors, advanced cooling systems, ultra-sensitive detectors and large arraysLarge Space Optics: As discussed earlier by Mario Perez, the Program Office supports HQ in monitoring/tracking the Segmented Mirror Technology Program (SMTP) and other technology development projects targeting large space telescopes

Ganel, Opher↗

Precision Cryogenic Dilatometer

A dilatometer based on a laser interferometer is being developed to measure mechanical creep and coefficients of thermal expansion (CTEs) of materials at temperatures ranging from ambient down to 15 K. This cryogenic dilatometer has been designed to minimize systematic errors that limit the best previously available dilatometers. At its prototype stage of development, this cryogenic dilatometer yields a strain measurement error of 35 ppb or 1.7 ppb/K CTE measurement error for a 20-K thermal load, for low-expansion materials in the temperature range from 310 down to 30 K. Planned further design refinements that include a provision for stabilization of the laser and addition of a high-precision sample-holding jig are expected to reduce the measurement error to 5-ppb strain error or 0.3-ppb/K CTE error for a 20-K thermal load. The dilatometer (see figure) includes a common-path, differential, heterodyne interferometer; a dual-frequency, stabilized source bench that serves as the light source for the interferometer; a cryogenic chamber in which one places the material sample to be studied; a cryogenic system for cooling the interior of the chamber to the measurement temperature; an ultra-stable alignment stage for positioning the chamber so that the sample is properly positioned with respect to the interferometer; and a data-acquisition and control system. The cryogenic chamber and the interferometer portion of the dilatometer are housed in a vacuum chamber on top of a vibration isolating optical table in a cleanroom. The sample consists of two pieces a pillar on a base both made of the same material. Using reflections of the interferometer beams from the base and the top of the pillar, what is measured is the change in length of the pillar as the temperature in the chamber is changed. In their fundamental optical and electronic principles of operation, the laser light source and the interferometer are similar to those described in Common-Path Heterodyne Interferometers (NPO-20786), NASA Tech Briefs, Vol. 25, No. 7 (July 2001), page 12a, and Interferometer for Measuring Displacement to Within 20 pm (NPO- 21221), NASA Tech Briefs, Vol. 27, No. 7 (July 2003), page 8a. However, the present designs incorporate a number of special geometric, optical, and mechanical features to minimize optical and thermal-expansion effects that contribute to measurement errors. These features include the use of low-thermal expansion materials for structural components, kinematic mounting and symmetrical placement of optical components, and several measures taken to minimize spurious reflections of laser beams.

Dudik, Matthew↗

Anticipated uncertainty budgets of PRARETIME and T2L2 techniques as applied to ExTRAS

The Experiment on Timing Ranging and Atmospheric Soundings, ExTRAS, was conceived jointly by the European Space Agency, ESA, and the Russian Space Agency, RSA. It is also designated the 'Hydrogen-maser in Space/Meteor-3M project'. The launch of the satellite is scheduled for early 1997. The package, to be flown on board a Russian meteorological satellite includes ultra-stable frequency and time sources, namely two active and auto-tuned hydrogen masers. Communication between the on-board hydrogen masers and the ground station clocks is effected by means of a microwave link using the modified version for time transfer of the Precise Range And Range-rate Equipment, PRARETIME, technique, and an optical link which uses the Time Transfer by Laser Link, T2L2, method. Both the PRARETIME and T2L2 techniques operate in a two-directional mode, which makes it possible to carry out accurate transmissions without precise knowledge of the satellite and station positions. Due to the exceptional quality of the on-board clocks and to the high performance of the communication techniques with the satellite, satellite clock monitoring and ground clocks synchronization are anticipated to be performed with uncertainties below 0.5 ns (1 sigma). Uncertainty budgets and related comments are presented.

Thomas, Claudine↗

Small Spacecraft for Planetary Atmospheric, Surface, and Interior Structure Using Radio Links

Scientific studies using spacecraft radio links have been conducted on almost every Solar System exploration mission in the past five decades and have led to numerous discoveries. Radio Science experiments have elucidated the thermal history of the Moon from high resolution gravitational field measurements, unveiled the interiors of Titan, Enceladus, Mercury, Phobos, Vesta and Ceres providing key evidence for identifying subsurface oceans on icy moons; sounded Titan, Saturn, and Pluto’s atmospheres, and refined models for the atmospheres, surfaces, and interior structure of Mars and Venus. A Juno experiment is in progress measuring the gravitational field of Jupiter to reveal its interior structures, as did a similar recent Cassini experiment with Saturn. Experiments at Mercury, the Jovian system, and other targets, are in development or planning phases. Over the next 30 years, significant advances in radio and laser link-science technologies, including nearly one order of magnitude improvement achievable in range-rate and range accuracy, could enable many new scientific breakthroughs. Future exploration concepts in many cases focus on applications of small spacecraft and can include spacecraft constellations for studies of atmospheric dynamics, interior structures, and surface properties. A set of science-enabling radio link technologies specific to small spacecraft instrumentation on future solar system missions are under study and development. Examples include field tests of radio scattering to determine soil properties, smallsat constellations for dense geographic and temporal atmospheric probing, small science-quality software-defined transponders, miniature ultra-stable oscillators, and advanced radio-metric calibrations at the Deep Space Network. This paper describes many of these technologies and their scientific applications.

Elliott, Harvey↗

Flight-Like Optical Reference Cavity for GRACE Follow-On Laser Frequency Stabilization

We describe a prototype optical cavity and associated optics that has been developed to provide a stable frequency reference for a future space-based laser ranging system. This instrument is being considered for inclusion as a technology demonstration on the recently announced GRACE follow-on mission, which will monitor variations in the Earth's gravity field.

Gravity Recovery and Climate Experiment (GRACE)↗