Search NASASearch

SEARCH · Search NASA

Results for “Ultrasonic Mixing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Ultrasonic Mixing of Epoxy Curing Agents

New ultrasonic mixing technique used to mix several curing agents/epoxy combinations. Major component of commercially available base epoxy resin used in tetraglycidylmethylenedianiline (TGMDA). In ultrasonic mixing system cup holds resin and curing agent during acoustic excitation. Samples placed in cup with top to ultrasonic horn forming bottom of cup. Ultrasonically treated until amber colored and transparent. Because ultrasonic agitation drives out entrapped air, degassing not necessary before cure.

Hodges, W. T.

Ultrasonic mixing of epoxy curing agents

A new technique for mixing solid curing agents into liquid epoxy resins using ultrasonic energy was developed. This procedure allows standard curing agents such as 4,4 prime-diaminodiphenyl sulfone (4,4 prime-DDS) and its 3,3 prime-isomer, (3,3 prime-DDS) to be mixed without prior melting of the curing agent. It also allows curing agents such as 4,4 prime-diaminodiphenyl sulfone (4,4 prime-DDS) and its 3,3 prime-isomer, (3,3 prime-DDS) to be mixed without prior melting of the curing agent. It also allows curing agents with very high melt temperatures such as 4,4 prime-diaminobenzophenone (4,4 prime-DABP) (242 C) to be mixed without premature curing. Four aromatic diamines were ultrasonically blended into MY-720 epoxy resin. These were 4,4 prime-DDS; 3,3 prime-DDA; 4,4 prime-DABP and 3,3 prime-DABP. Unfilled moldings were cast and cured for each system and their physical and mechanical properties compared.

Hodges, W. T.

Ultrasonic mixing of epoxy curing agents

A new technique for mixing solid curing agents into liquid epoxy resins using ultrasonic energy was developed. This procedure allows standard curing agents such as 4,4 prime-diaminodiphenyl sulfone (4,4 prime-DDS) and its 3,3 prime-isomer, (3,3 prime-DDS) to be mixed without prior melting of the curing agent. It also allows curing agents with very high melt temperatures such as 4,4 prime-diaminodiphenyl sulfone (4,4 prime-DDS) and its 3,3 prime-isomer, (3,3 prime-DDS) to be mixed without prior melting of the curing agent. It also allows curing agents with very high melt temperatures such as 4,4 prime-diaminobenzophenone (4,4 prime-DABP) (242 C) to be mixed without premature curing. Four aromatic diamines were ultrasonically blended into MY-720 epoxy resin. These were 4, 4 prime-DDS; 3,3 prime-DDA; 4, 4 prime-DABP and 3,3 prime-DABP. Unfilled moldings were cast and cured for each system and their physical and mechanical properties compared. Previously announced in STAR as N83-27018

Hodges, W. T.

Some Improvements in H-PDLCs

Some improvements have been made in the formulation of holographically formed polymer-dispersed liquid crystals (H-PDLCs) and in the fabrication of devices made from these materials, with resulting improvements in performance. H-PDLCs are essentially volume Bragg gratings. Devices made from H-PDLCs function as electrically switchable reflective filters. Heretofore, it has been necessary to apply undesirably high drive voltages in order to switch H-PDLC devices. Many scientific papers on H-PDLCs and on the potential utility of H-PDLC devices for display and telecommunication applications have been published. However, until now, little has been published about improving quality control in synthesis of H-PDLCs and fabrication of H-PDLC devices to minimize (1) spatial nonuniformities within individual devices, (2) nonuniformities among nominally identical devices, and (3) variations in performance among nominally identical devices. The improvements reported here are results of a research effort directed partly toward solving these quality-control problems and partly toward reducing switching voltages. The quality-control improvements include incorporation of a number of process controls to create a relatively robust process, such that the H-PDLC devices fabricated in this process are more nearly uniform than were those fabricated in a prior laboratory-type process. The improved process includes ultrasonic mixing, ultrasonic cleaning, the use of a micro dispensing technique, and the use of a bubble press.

Crawford, Gregory P.

INL_Intern_Poster_ColeBailey [Poster]

Understanding the thermophysical properties of molten salts is crucial for the advancement of nuclear fuels. This project presents the design of a custom differential thermal analyzer (DTA) that utilizes non-contact ultrasonic mixing to agitate samples and prevent supercooling. The supercooling effect occurs when a liquid is below its freezing point without solidifying. This can be observed when a liquid in a freezer instantly transitions to its solid phase upon disturbance. By avoiding this effect, accurate transition temperatures of molten salts can be gathered for future applications. Initial mixing results were promising, leading to further refinement of the waveguides using ABAQUS to maximize input energy into the fluid. Future work will focus on integrating both mixing and cooling in conjunctions to observe the avoided effect.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN

Nanoscale Subsurface Imaging of Nanocomposites via Resonant Difference-Frequency Atomic Force Ultrasonic Microscopy

A scanning probe microscope methodology, called resonant difference-frequency atomic force ultrasonic microscopy (RDF-AFUM), has been developed. The method employs an ultrasonic wave launched from the bottom of a sample while the cantilever of an atomic force microscope engages the sample top surface. The cantilever is driven at a frequency differing from the ultrasonic frequency by one of the contact resonance frequencies of the cantilever. The nonlinear mixing of the oscillating cantilever and the ultrasonic wave at the sample surface generates difference-frequency oscillations at the cantilever contact resonance. The resonance-enhanced difference-frequency signals are used to create amplitude and phase-generated images of nanoscale near-surface and subsurface features. RDF-AFUM phase images of LaRC-CP2 polyimide polymer containing embedded nanostructures are presented. A RDF-AFUM micrograph of a 12.7 micrometer thick film of LaRC-CP2 containing a monolayer of gold nanoparticles embedded 7 micrometers below the specimen surface reveals the occurrence of contiguous amorphous and crystalline phases within the bulk of the polymer and a preferential growth of the crystalline phase in the vicinity of the gold nanoparticles. A RDF-AFUM micrograph of LaRC-CP2 film containing randomly dispersed carbon nanotubes reveals the growth of an interphase region at certain nanotube-polymer interfaces.

Cantrell, Sean A.

Method and apparatus to characterize ultrasonically reflective contrast agents

A method and apparatus for characterizing the time and frequency response of an ultrasonically reflective contrast agent is disclosed. An ultrasonically reflective contrast agent is injected, under constant pressure, into a fluid flowing through a pump flow circuit. The fluid and the ultrasonically reflective contrast agent are uniformly mixed in a mixing chamber, and the uniform mixture is passed through a contrast agent chamber. The contrast agent chamber is acoustically and axially interposed between an ultrasonic transducer chamber and an acoustic isolation chamber. A pulse of ultrasonic energy is transmitted into the contrast agent chamber from the ultrasonic transducer chamber. An echo waveform is received from the ultrasonically reflective contrast agent, and it is analyzed to determine the time and frequency response of the ultrasonically reflective contrast agent.

Pretlow, Robert A., III

Species-specific acoustic responses by bats to ultrasonic stimuli used for reducing bat-wind turbine interactions

An unintended consequence of wind energy generation is bat fatalities caused by wind turbine blade strikes. One potential approach to reduce collision risk is to use ultrasound to create an uncomfortable or disorienting airspace around wind turbine blades. Ultrasonic deterrents (UDs) have produced mixed results in experimental field studies at commercial wind energy facilities, with effectiveness varying by species and location. It is possible that some species can alter their normal echolocation characteristics to counter the signal of UDs. Our broad objective was to maximize the effectiveness of a UD by comparing changes in echolocation characteristics during three UD frequency emissions among species, between seasons, and between sex. We hypothesized that UD emissions with frequencies most similar to each species’ echolocation characteristics would be more likely to alter the bats’ echolocation, and bat responses would vary between seasons and sex for each species. We released wild-captured bats into a 60 m × 10 m × 4.4 m (length × width × height) flight cage located in San Marcos, Texas, USA, from July to October 2020 and March to May 2021 and monitored echolocation frequencies with ultrasonic microphones. We conducted trials on Brazilian free-tailed bats ( Tadarida brasiliensis ; n = 54), cave myotis ( Myotis velifer ; n = 44), red bats ( Lasiurus blossevilli , Lasiurus borealis ; n = 41), evening bats ( Nycticeius humeralis ; n = 32), and tricolored bats ( Perimyotis subflavus ; n = 8). We found that species with high-frequency echolocation calls altered their echolocation signatures more commonly during high-frequency UD emissions, whereas low-frequency bats altered their echolocation signatures more commonly during low-frequency UD emissions. Additionally, echolocation responses varied between seasons and sexes for several species. Variations in responses may be dependent on species migratory status, differences in mating behavior and mating season, hormonal differences between sexes and seasons, and/or constraints on echolocation adaptability. Our results offer insights into the variable effectiveness of UDs at reducing bat fatalities at wind turbines and provide information for potential adjustments to UDs for improved success.

17 WIND ENERGY

Nanoscale Subsurface Imaging via Resonant Difference-Frequency Atomic Force Ultrasonic Microscopy

A novel scanning probe microscope methodology has been developed that employs an ultrasonic wave launched from the bottom of a sample while the cantilever of an atomic force microscope, driven at a frequency differing from the ultrasonic frequency by the fundamental resonance frequency of the cantilever, engages the sample top surface. The nonlinear mixing of the oscillating cantilever and the ultrasonic wave in the region defined by the cantilever tip-sample surface interaction force generates difference-frequency oscillations at the cantilever fundamental resonance. The resonance-enhanced difference-frequency signals are used to create images of embedded nanoscale features.

Cantrell, Sean A.

Resonant difference-frequency atomic force ultrasonic microscope

A scanning probe microscope and methodology called resonant difference-frequency atomic force ultrasonic microscopy (RDF-AFUM), employs an ultrasonic wave launched from the bottom of a sample while the cantilever of an atomic force microscope, driven at a frequency differing from the ultrasonic frequency by one of the contact resonance frequencies of the cantilever, engages the sample top surface. The nonlinear mixing of the oscillating cantilever and the ultrasonic wave in the region defined by the cantilever tip-sample surface interaction force generates difference-frequency oscillations at the cantilever contact resonance. The resonance-enhanced difference-frequency signals are used to create images of nanoscale near-surface and subsurface features.

Cantrell, John H.

Effects of ultrasonic fields in the phosphoric acid process

A process of apatite decomposition with sulfuric acid was studied under the influence of ultrasound in the phosphoric acid production process. The studies were carried out with and without ultrasonic fields in the reaction mixture, which resembled the mixing ratio used in technical production processes. Ultrasound with a frequency of 20 kHz and an intensity of 1 W/sq cm was used in the studies. A very favorable ultrasonic effect upon the degree of apatite decomposition was observed. The ultrasonic field affects the shape of byproduct gypsum crystals. In the H3PO4 production process without ultrasound, the byproduct gypsum crystallizes as long, thin needles which cause problems in filtration. In the trials involving the application of wound, gypsum crystallized in the form of small platelets possessing a favorable ratio of length to width.

Kowalska, E.

Evaluation of experimental epoxy monomers

Future generation aircraft need higher performance polymer matrices to fully achieve the weight savings possible with composite materials. New resins are being formulated in an effort to understand basic polymer behavior and to develop improved resins. Some polymer/curing agent combinations that could be useful are difficult to process. In the area of epoxies, a major problem is that some components have physical properties which make them difficult to utilize as matrix resins. A previous study showed that the use of ultrasonic energy can be advantageous in the mixing of curing agents into a standard epoxy resin, such as MY 720 (Ciba-Geigy designation). This work is expanded to include three novel epoxides.

Hodges, W. T.

Evaluation of experimental epoxy monomers

Future generation aircraft need higher performance polymer matrices to fully achieve the weight savings possible with composite materials. New resins are being formulated in an effort to understand basic polymer behavior and to develop improved resins. Some polymer/curing agent combinations that could be useful are difficult to process. In the area of epoxies, a major problem is that some components have physical properties which make them difficult to utilize as matrix resins. A previous study showed that the use of ultrasonic energy can be advantageous in the mixing of curing agents into a standard epoxy resin, such as MY 720 (Ciba-Geigy designation). This work is expanded to include three novel epoxides.

Hodges, W. T.

Ultrasonic Doppler measurement of renal artery blood flow

Implantable pulsed Doppler ultrasonic flowmeter development has resulted in designs for application to the aortas of dogs and humans, and to human renal and coronary arteries. A figure of merit was derived for each design, indicating the degree of its precision. An H-array design for transcutaneous observation of blood flow was developed and tested in vitro. Two other simplified designs for the same purpose obviate the need to determine vessel orientation. One of these will be developed in the next time period. Techniques for intraoperative use and for implantation have had mixed success. While satisfactory on large vessels, higher ultrasonic frequencies and alteration of transducer design are required for satisfactory operation of pulsed Doppler flowmeters with small vessels.

Source record

Stabilization and Low-Frequency Oscillation of Capillary Bridges with Modulated Acoustic Radiation Pressure

In the work reported here it is demonstrated that acoustic radiation pressure may be used in simulated low gravity to produce stable bridges significantly beyond the Rayleigh limit with S as large as 3.6. The bridge (PDMS mixed with a dense liquid) has the same density as the surrounding water bath containing an ultrasonic standing wave. Modulation was first used to excite specific bridge modes. In the most recent work reported here the shape of the bridge is optically sensed and the ultrasonic drive is electronically adjusted such that the radiation stress distribution dynamically quenches the most unstable mode. This active control simulates passive stabilization suggested for low gravity. Feedback increases the mode frequency in the naturally stable region since the effective stiffness of the mode is increased.

Marston, Philip L.