Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ultrasonic flowmeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evaluation of several ultrasonic flowmeter transducers in cryogenic environment

Eighteen piezoelectric ultrasonic flowmeter transducers were laboratory tested to determine their suitability and long range reliability for use by the National Transonic Facility (NTF) to measure the flow rate of 450 Kg/sec of liquid nitrogen (LN2). Tests included thermally cycling each transducer 50 to 150 times over a temperature range of 295 K (ambient) to 77 K (LN2). The transducers were submerged in liquid nitrogen for 1 to 4 hours and the signal strength and quality noted. Results disclose that the current state-of-the-art ultrasonic flow transducers are very reliable and will meet the stringent requirements of the NTF.

Moughon, W. C.↗

Space Shuttle Hypergol Load Determination Using Nonintrusive Ultrasonic Flowmeters

Space Shuttle preflight hypergol oxidizer and fuel loading were monitored using a nonintrusive flow measurement system (NFMS) during preflight operation. A pair of 4-megahertz ultrasonic transducers measured the flow rate using a transit-time flow measurement technique. Using wireless cellular phone technology, flow-rate data was monitored and recorded. Excellent correlation was observed between the flow profiles measured using the proposed nonintrusive ultrasonic flowmeters (UFM's) and those made from conventional intrusive turbine meters (TFM). Based on the preliminary tests, it is concluded that the nonintrusive method of flow measurement has the same or higher accuracy, is simpler, and costs less than the existing TFM. Benefits of UFM's include a highly flexible, cost-effective, reliable, hazard free, and streamlined hypergol operation. Redundant installation of ultrasonic flowmeters was recommended for a few more launches prior to the replacement of the existing TFM.

Werlink, Rudolph↗

An ultrasonic flowmeter for measuring dynamic liquid flow

A novel oscillating pipe system was developed to provide dynamic calibration wherein small sinusoidal signals with amplitudes of 0.5 to 10% of the steady-state flow were added to the steady-state flow by oscillating the flowmeter relative to the fixed pipes in the flow system. Excellent agreement was obtained between the dynamic velocities derived from an accelerometer mounted on the oscillating pipe system and those sensed by the flowmeter at frequencies of 7, 19, and 30 Hz. Also described were the signal processing techniques used to retrieve the small sinusoidal signals which were obscured by the fluid turbulence.

Carpini, T. D.↗

Evaluation of a pulsed ultrasonic Doppler flowmeter

The in vivo application of the pulsed ultrasound Doppler velocity meter (PUDVM) for measuring arterial velocity waveforms is reported. In particular, the performance of the PUDVM is compared with a hot film anemometer of proven accuracy.

Wells, M. K.↗

Low-g propellant gaging

A program to develop and demonstrate technology for low gravity propellant gaging on future geostationary satellites is described. Evaluations were performed to select four gaging concepts for ground tests and low gravity tests in the NASA KC-135 aircraft. The selected concepts were: (1) an ultrasonic point sensor system, (2) a nucleonic gaging system, (3) an ultrasonic torsional wave guide, and (4) an ultrasonic flowmeter. As a result of successful ground and KC-135 tests, two concepts (the ultrasonic point sensor and the nucleonic systems) were selected for orbital test in a shuttle Get-Away-Special experiment.

Orton, George↗

Ultrasonic Doppler measurement of renal artery blood flow

Implantable pulsed Doppler ultrasonic flowmeter development has resulted in designs for application to the aortas of dogs and humans, and to human renal and coronary arteries. A figure of merit was derived for each design, indicating the degree of its precision. An H-array design for transcutaneous observation of blood flow was developed and tested in vitro. Two other simplified designs for the same purpose obviate the need to determine vessel orientation. One of these will be developed in the next time period. Techniques for intraoperative use and for implantation have had mixed success. While satisfactory on large vessels, higher ultrasonic frequencies and alteration of transducer design are required for satisfactory operation of pulsed Doppler flowmeters with small vessels.

Source record↗

Implantable telemetry for small animals

A series of totally implantable telemetry devices for use in measuring deep body parameters in small animals were developed. Under a collaborative agreement with NASA, several of these systems; the continuous wave Doppler ultrasonic flowmeter, the multichannel telemetry system, and the inductively-powered dual channel cardiac pacer were evaluated in a series of ten mongrel dogs (15 to 20 kg.). These systems were used to measure ascending aortic and coronary blood flow, aortic pressure, and subcutaneous EKG.

Source record↗

Intrapericardial denervation - Radial artery blood flow and heart rate responses to LBNP

The effects of intrapericardial denervation on the radial artery blood flow velocity (RABFV) and heart rate (HR) responses to LBNP in rhesus monkeys were investigated by measuring the RABFV transcutaneously by a continuous-wave Doppler ultrasonic flowmeter in order to derive an index of forearm blood flow response to low (0 to -20 mm Hg) and high (0 to -60 mm Hg) ramp exposures during supine LBNP. Four of the eight subjects were subjected to efferent and afferent cardiac denervation. It was found that, during low levels of LBNP, monkeys with cardiac denervation exhibited no cardiopulmonary baroreceptor-mediated change in the RABFV or HR, unlike the intact animals, which showed steady decreases in RABFV during both high- and low-pressure protocols. It is suggested that forearm blood flow and HR responses to low-level LBNP, along with pharmacological challenge, are viable physiological tests for verifying the completeness of atrial and cardiopulmonary baroreceptor denervation.

Mckeever, Kenneth H.↗

Nonintrusive dynamic flowmeter

Description of some of the design and performance characteristics of an ultrasonic dynamic flowmeter which combines nonintrusiveness, fast response, high accuracy, and high resolution and is intended for use with cryogenic liquids and water. The flowmeter measures to 1% accuracy the dynamic as well as the steady flow velocity averaged over the pipe area.

Pedersen, N. E.↗

Sodium Hydrogen Sensor and Acoustic Flow Sensor Development

This report documents the development of diffusion-type hydrogen meters (DTHMs) as part of a steam generator leak detection system (SGLDS) of sodium-cooled fast reactors (SFR) and the demonstration of the capabilities of acoustic flowmeters, including a commercial UTFM (Flexim FLUXUS F721) and an Argonne HT acoustic flowmeter running on shear-to-longitudinal mode. It also evaluates two Argonne permanent magnet flowmeters (PMFMs).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Doppler instrumentation for measuring blood velocity and flow

Doppler ultrasonic blood flowmeters are reviewed in detail. The importance of measurement accuracy for transcutaneous flowmeters and their clinical application is stressed. Doppler imaging was combined with conventional pulse echo imaging, and diagnostic information was extracted from flow signals. The range and extent of applications of Doppler instruments was also presented.

Gill, R. W.↗

Analysis of the feedback system in a nonintrusive dynamic flowmeter for measuring Pogo oscillations

Equations were developed which describe the closed loop feedback system operation of a proposed ultrasonic, dynamic, nonintrusive flowmeter whose design is based on a constant phase, voltage controlled frequency feedback concept. These equations are based on linear feedback system theory. The time constant of a low pass filter is taken into account. The equations show that the larger the open loop gain, the smaller the error due to fluctuations in the speed of sound and the smaller the effective time constant.

Chapin, W. G.↗

Advanced Recording and Preprocessing of Physiological Signals

The measurement of the volume flow-rate of blood in an artery or vein requires both an estimate of the flow velocity and its spatial distribution and the corresponding cross-sectional area. Transcutaneous measurements of these parameters can be performed using ultrasonic techniques that are analogous to the measurement of moving objects by use of a radar. Modern digital data recording and preprocessing methods were applied to the measurement of blood-flow velocity by means of the CW Doppler ultrasonic technique. Only the average flow velocity was measured and no distribution or size information was obtained. Evaluations of current flowmeter design and performance, ultrasonic transducer fabrication methods, and other related items are given. The main thrust was the development of effective data-handling and processing methods by application of modern digital techniques. The evaluation resulted in useful improvements in both the flowmeter instrumentation and the ultrasonic transducers. Effective digital processing algorithms that provided enhanced blood-flow measurement accuracy and sensitivity were developed. Block diagrams illustrative of the equipment setup are included.

Bentley, P. B.↗

Flowmeter evaluation for on-orbit operations

Various flowmetering concepts were flow tested to characterize the relative capabilities and limitations for on-orbit fluid-transfer operations. Performance results and basic operating principles of each flowmetering concept tested are summarized, and basic considerations required to select the best flowmeter(s) for fluid system application are discussed. Concepts tested were clamp-on ultrasonic, area averaging ultrasonic, offset ultrasonic, coriolis mass, vortex shedding, universal venturi tube, turbine, bearingless turbine, turbine/turbine differential-pressure hybrid, dragbody, and dragbody/turbine hybrid flowmeters. Fluid system flowmeter selection considerations discussed are flowmeter performance, fluid operating conditions, systems operating environments, flowmeter packaging, flowmeter maintenance, and flowmeter technology. No one flowmetering concept tested was shown to be best for all on-orbit fluid systems.

Baird, R. S.↗

Development of ultrasonic methods of hemodynamic measurements

A pulsed ultrasonic Doppler velocity meter which can be used (by modifying transducers) as a flowmeter for blood circulation was experimentally studied. Calculations and profiles of turbulent and laminar flow within blood vessels are shown. Graphs and charts of transducers are included.

Histand, M. B.↗