Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ultraviolet”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Photometric Redshifts with the LSST. II. The Impact of Near-infrared and Near-ultraviolet Photometry

Accurate photometric redshift (photo-z) estimates are essential to the cosmological science goals of the Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST). In this work, we use simulated photometry for mock galaxy catalogs to explore how LSST photo-z estimates can be improved by the addition of near-infrared (NIR) and/or ultraviolet (UV) photometry from the Euclid, Wide-Field InfrarRed Survey Telescope (WFIRST), and/or Cosmological Advanced Survey Telescope for Optical and ultraviolet Research (CASTOR) space telescopes. Generally, we find that deeper optical photometry can reduce the standard deviation of the photo-z estimates more than adding NIR or UV filters but that additional filters are the only way to significantly lower the fraction of galaxies with catastrophically under- or overestimated photo-z. For Euclid, we find that the addition of JH 5σ photometric detections can reduce the standard deviation for galaxies with z > 1 (z > 0.3) by ∼20% (∼10%), and the fraction of outliers by ∼40% (∼25%). For WFIRST, we show how the addition of deep YJHK photometry could reduce the standard deviation by ≳50% at z > 1.5 and drastically reduce the fraction of outliers to just ∼2% overall. For CASTOR, we find that the addition of its UV- and u-band photometry could reduce the standard deviation by ∼30% and the fraction of outliers by ∼50% for galaxies with z < 0.5. We also evaluate the photo-z results within sky areas that overlap with both the NIR and UV surveys and when spectroscopic training sets built from the surveys’ small-area deep fields are used.

79 ASTRONOMY AND ASTROPHYSICS↗

Generation of extreme-ultraviolet beams with time-varying orbital angular momentum

Light fields carrying orbital angular momentum (OAM) provide powerful capabilities for applications in optical communications, microscopy, quantum optics, and microparticle manipulation. We introduce a property of light beams, manifested as a temporal OAM variation along a pulse: the self-torque of light. Although self-torque is found in diverse physical systems (i.e., electrodynamics and general relativity), it was not realized that light could possess such a property. We demonstrate that extreme-ultraviolet self-torqued beams arise in high-harmonic generation driven by time-delayed pulses with different OAM. We monitor the self-torque of extreme-ultraviolet beams through their azimuthal frequency chirp. Lastly, this class of dynamic-OAM beams provides the ability for controlling magnetic, topological, and quantum excitations and for manipulating molecules and nanostructures on their natural time and length scales.

74 ATOMIC AND MOLECULAR PHYSICS↗

High power picosecond green and deep ultraviolet generations with an all-fiberized MOPA

We demonstrate high power picosecond green and deep ultraviolet (DUV) lasers based on an all-fiberized master oscillator power amplifier (MOPA). The main power amplifier is fabricated with a highly Yb-doped large mode area (LMA) silicate glass fiber. It delivers 75.2-W laser output at 1029 nm with a pulse repetition rate of 10 MHz and a pulse duration of 70 ps. With a lithium triborate (LBO) crystal, a 43.0-W green output at 514.5 nm has been achieved with a pulse duration of 55 ps. With a caesium lithium borate (CLBO) crystal, a 14.5-W picosecond DUV output at 257 nm has been generated, which is the highest power for the all-fiber based DUV laser, to the best of our knowledge.

Pan, Lei (ORCID:0000000288896117)↗

Extreme Ultraviolet and Beyond Extreme Ultraviolet Lithography Using Amorphous Zeolitic Imidazolate Resists Deposited by Atomic/Molecular Layer Deposition

Amorphous zinc-imidazolate (aZnMIm) resists show potential to meet the demands for next-generation high-numerical aperture (high-NA) metal-containing extreme ultraviolet (EUV) resist materials, given their ease of deposition by atomic/molecular layer deposition (ALD/MLD) at thicknesses of 20 nm and below. Here, this study demonstrates that aZnMIm thin films, previously identified as high-resolution electron beam resists, can also function as negative-tone EUV photoresists. Water development achieves high sensitivity (5 mJ/cm 2 ) but leaves significant residue, while acetic acid development results in poor contrast. A hybrid approach─water followed by acetic acid─enables residue-free development with a sensitivity of 181 mJ/cm 2 . Dry development using 1,1,1,5,5,5-hexafluoroacetylacetone (hfacH) is also possible but shows lower sensitivity (375 mJ/cm 2 ) compared to wet development methods. EUV photoelectron spectroscopy (PES), reflectometry/EUV absorption, total electron yield (TEY), residual gas analysis (RGA), and time-of-flight secondary ion mass spectrometry (TOF-SIMS) were used to investigate the effects of EUV irradiation on aZnMIm resists. Reflectometry experiments reveal an aZnMIm EUV absorption coefficient of 6.2 μm –1 , while PES and TEY analyses show that, compared to poly(4-hydroxystyrene) (PHS), a polymer-based reference resist, aZnMIm emits more primary and secondary electrons but generates fewer slow electrons relative to its primary electron emission; its total electron yield is similar to that of poly(methyl methacrylate) (PMMA) resists. When exposed to EUV, aZnMIm predominantly outgasses H 2 , as determined by RGA. TOF-SIMS measurements demonstrate that high-dose EUV exposure only partially fragments the 2-methylimidazole (2MIm) organic linkers, unlike high-dose electron beam exposure, which is known to completely degrade them. Additionally, aZnMIm resists show promise for potential beyond EUV lithography (BEUVL) due to the presence of Zn, which provides higher sensitivity at a wavelength of 6.7 nm compared to other metal ions, such as Sn, that are currently used in the best-performing EUV metal–organic resists. TEY measurements demonstrate that aZnMIm emits nearly twice as many electrons as PHS at 6.7 nm. The BEUV TEY of aZnMIm also surpasses that of PMMA, poly(pentafluorostyrene), and poly(4-iodostyrene), with the latter two being known for their high EUV TEYs. This work provides insight into zeolitic imidazolate framework (ZIF)-based EUV and BEUV resists and highlights their potential for both wet and dry development.

lithography↗

High-power ultraviolet (UV) and vacuum ultraviolet (VUV) lamps with micro-cavity plasma arrays

A plasma lamp includes plates that are approximately parallel, with at least one array of microcavities formed in a surface of at least one plate. When desirable, the plates are separated a fixed distance by spacers with at least one spacer being placed near the plate's edge to form a hermetic seal therewith. A gas makes contact with the microcavity array. Electrodes capable of delivering a time-varying voltage are located on the surface of each plate. At least one electrode is located on an exterior surface of at least one interior plate. Optionally, protective windows may be placed over the electrodes. The application of the time-varying voltage interacts with the gas to form a glow discharge plasma in the microcavities and the fixed volume between the plates (when present). The glow discharge plasma efficiently and uniformly emits UV/VUV radiation over the entire surface of the lamp.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-power ultraviolet (UV) and vacuum ultraviolet (VUV) lamps with micro-cavity plasma arrays

A product having at least one plasma lamp that includes plates that are approximately parallel, with at least one array of microcavities formed in a surface of at least one plate. When desirable, the plates are separated a fixed distance by spacers with at least one spacer being placed near the plate's edge to form a hermetic seal therewith. A gas makes contact with the microcavity array. Electrodes capable of delivering a time-varying voltage are located such that the application of the time-varying voltage interacts with the gas to form a glow discharge plasma in the microcavities and the fixed volume between the plates. The glow discharge plasma efficiently and uniformly emits radiation that is predominantly in the UV/VUV spectral range with at least a portion of the radiation being emitted from the plasma lamp.

Park, Sung-Jin↗

Effect of Prolonged Ultraviolet Radiation Exposure on the Blast Response of Fiber Reinforced Composite Plates

An experimental study with corresponding numerical simulations was conducted to evaluate the blast response of composite plates after prolonged exposure to ultraviolet radiation. Two composite materials were used in this study, namely carbon fiber/epoxy and glass fiber/vinyl ester. The composite materials consisted of four unidirectional fiber plies oriented in a [± 45°]s layup. The plates were placed in a QUV Accelerated Weathering Tester for 500 h of exposure on each face, totaling 1000 h of ultraviolet radiation exposure, equivalent to 2.5 MJ/m{sup 2} of energy. The QUV Accelerated Weathering Tester was equipped with eight UVA-340 lamps to provide real service life exposure conditions. Material characterization experiments were performed on virgin specimens, as well as specimens exposed to ultraviolet radiation for 1000 h to determine its effect on the mechanical properties of the composites. Blast experiments were conducted on the composite plates to investigate the dynamic response before and after exposure to ultraviolet radiation. The plates were clamped on all edges and subjected to an air blast using a shock tube apparatus. Three-dimensional digital image correlation was coupled with high-speed photography to obtain full-field displacements of the specimens during blast loading. Furthermore, three piezoelectric pressure transducers were mounted on the shock tube apparatus and utilized to measure the pressure history of the shock wave loading. The quasi-static material characterization showed that the tensile modulus E{sub 1} had minimal change after exposure to ultraviolet radiation for 1000 h. However, matrix-dominated properties such as the in-plane shear modulus G{sub 12} increased after exposure to ultraviolet light for both the carbon and glass fiber composites, which resulted in lower out-of-plane displacements during blast loading. For the carbon fiber plates, the forced vibration frequency induced by the transverse blast load was higher in plates exposed to ultraviolet radiation when compared to virgin specimens. However, for the glass fiber plates exposed to ultraviolet radiation, the forced vibration frequency decreased when compared to virgin specimens. Finally, the finite element simulations were in good agreement with the experimental results. The simulations revealed that the glass fiber plates exposed to ultraviolet radiation had higher failure strains at the boundary than virgin specimens, despite having higher stiffness. A parametric study in which higher loading was simulated also showed that the glass fiber plates experienced more damage after 1000 h of ultraviolet radiation exposure.

36 MATERIALS SCIENCE↗

Jupiter in the Ultraviolet: Acetylene and Ethane Abundances in the Stratosphere of Jupiter from Cassini Observations between 0.15 and 0.19 μm

At wavelengths between 0.15 and 0.19 μm, the far-ultraviolet spectrum of Jupiter is dominated by the scattered solar spectrum, attenuated by molecular absorptions primarily by acetylene and ethane, and to a lesser extent ammonia and phosphine. We describe the development of our radiative transfer code that enables the retrieval of abundances of these molecular species from ultraviolet reflectance spectra. As a proof-of-concept we present an analysis of Cassini Ultraviolet Imaging Spectrograph (UVIS) observations of the disk of Jupiter during the 2000/2001 flyby. The ultraviolet-retrieved acetylene abundances in the upper stratosphere are lower than those predicted by models based solely on infrared thermal emission from the mid-stratosphere observed by the Composite Infrared Spectrometer (CIRS), requiring an adjustment to the vertical profiles above 1 mbar. We produce a vertical acetylene abundance profile that is compatible with both CIRS and UVIS, with reduced abundances at pressures <1 mbar: the 0.1 mbar abundances are 1.21 ± 0.07 ppm for acetylene and 20.8 ± 5.1 ppm for ethane. Finally, we perform a sensitivity study for the JUICE ultraviolet spectrograph, which has extended wavelength coverage out to 0.21 μm, enabling the retrieval of ammonia and phosphine abundances, in addition to acetylene and ethane.

79 ASTRONOMY AND ASTROPHYSICS↗

Biocompatible Bi(OH)3 nanoparticles with reduced photocatalytic activity as possible ultraviolet filter in sunscreens

Highlights: • Facilesynthesis of inorganic Bi(OH){sub 3} nanoparticles. • High biocompatibility in human skin and dog kidney cells in vitro. • Ultraviolet filter capable of reducing the photocatalytic activity of TiO{sub 2} and ZnO. • Preparation of TiO{sub 2}/Bi(OH){sub 3} and classical TiO{sub 2}/ZnO sunscreen formulations. • Significantly improved photoprotection and photostability compared to TiO{sub 2}/ZnO. - Abstract: In this study we investigate readily synthesised Bi(OH){sub 3} nanoparticles as a novel, multifunctional ultraviolet filter for sunscreen. The absorbance of Bi(OH){sub 3} NPs in the ultraviolet region is comparable to that of both ZnO and TiO{sub 2} NPs used in commercial sunscreens. In vitro photoprotection results show that the combination of TiO{sub 2}/Bi(OH){sub 3} is more efficient than TiO{sub 2}/ZnO over the whole UV range, with an increase in sun protection factor of 28%. The emulsions show rheological properties comparable to those of commercial sunscreens. The combination of TiO{sub 2}/Bi(OH){sub 3} led to insignificant damage on pre-painted steel panels after exterior exposure for twelve weeks. We also demonstrate that the addition of Bi(OH){sub 3} NPs reduces the degradation of crystal violet by photocatalytically active TiO{sub 2} or ZnO NPs under ultraviolet exposure. Finally, assessment of the biocompatibility of Bi(OH){sub 3} with HaCaT keratinocytes and Madin-Darby Canine Kidney (MDCK) cells in vitro is described.

60 APPLIED LIFE SCIENCES↗

Evidence of excited-state lifetime enhancement in dimyristoyl-phosphocholine nanodiscs by ultraviolet absorption spectroscopy

Ultraviolet absorption spectroscopy is an analytical tool that is commonly utilized to determine protein concentrations, primarily due to characteristic absorption of tryptophan and tyrosine at 280 nm. Accurate concentration determination is essential to the accuracy of many biophysical techniques, and ultraviolet absorption provides a convenient and rapid method to assess protein concentration. However, the widespread usage of this method assumes that ultraviolet absorption is the same for individual amino acids in aqueous solution (where the molar extinction coefficient was measured) as for the amino acid in the conformational environment of the protein of interest. We demonstrate that additional considerations may be necessary for the membrane scaffold protein in dimyristoyl-phosphocholine nanodiscs through ultraviolet absorption spectroscopy of nanodiscs, liposomes, the membrane scaffold protein, and a mixture of liposomes and the non-nanodisc-associated protein. The aromatic amino acids of the membrane scaffold protein absorb significantly less light at 280 nm when associated with lipids in a lipoprotein assembly, which we plausibly attribute to an enhancement of chromophore excited-state lifetimes due to reduced intramolecular motion in the nanodisc. We caution that using the molar absorptivity of the membrane scaffold protein alone to determine nanodisc concentrations may not yield accurate results. Instead, the molar absorptivity of each nanodisc formulation should be explored independently to account for the unique conformational environment of each nanodisc.

59 BASIC BIOLOGICAL SCIENCES↗

In-Situ Nanoscale Focusing of Extreme Ultraviolet Solid-State High Harmonics

Extreme ultraviolet light delivering radiation with a wavelength shorter than approximately 100 nm is now available from solid-state sources. However, despite exceptional progress, efficient focusing of extreme ultraviolet photons to their ultimate diffraction limit remains a formidable challenge because of the precision of the focusing by curved, optical surfaces. Here we integrate coherent short-wavelength high-order harmonics from a MgO crystal, with a high-numerical-aperture, nanostructured, focusing element etched onto the surface of the crystal itself. We focus extreme ultraviolet light, seventh harmonic of an 800-nm laser, with a zone plate of numerical aperture 0.35, down to a waist radius of 150 nm, with 18% focusing efficiency. The estimated intensity approaches 10 7 W/cm 2 . Future developments may demonstrate nanoscale laser ablation and miniaturization of extreme ultraviolet coherent sources on a chip.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Red and Reddened: Ultraviolet through Near-infrared Observations of Type Ia Supernova 2017erp

We present space-based ultraviolet/optical photometry and spectroscopy with the Swift Ultra-Violet/Optical Telescope and Hubble Space Telescope (HST), respectively, along with ground-based optical photometry and spectroscopy and near-infrared spectroscopy of supernova SN 2017erp. The optical light curves and spectra are consistent with a normal SN Ia. Compared to previous photometric samples in the near-ultraviolet (NUV), SN 2017erp has UV colors that are redder than NUV-blue SNe Ia corrected to similar optical colors. The chromatic difference between SNe 2011fe and 2017erp is dominated by the intrinsic differences in the UV rather than the expected dust reddening. This chromatic difference is similar to the SALT2 color law, derived from rest-frame ultraviolet photometry of higher redshift SNe Ia. Differentiating between intrinsic UV diversity and dust reddening can have important consequences for determining cosmological distances with rest-frame ultraviolet photometry. This ultraviolet spectroscopic series is the first from HST of a normal, albeit reddened, NUV-red SN Ia and is important for analyzing SNe Ia with intrinsically redder NUV colors. We show model comparisons suggesting that metallicity could be the physical difference between NUV-blue and NUV-red SNe Ia, with emission peaks from reverse fluorescence near 3000 Å implying a factor of ~10 higher metallicity in the upper layers of SN 2017erp compared to SN 2011fe. Metallicity estimates are very model dependent, however, and there are multiple effects in the UV. Further models and UV spectra of SNe Ia are needed to explore the diversity of SNe Ia, which show seemingly independent differences in the near-UV peaks and mid-UV flux levels.

79 ASTRONOMY AND ASTROPHYSICS↗

In-flight Characterization and Calibration of the Juno-ultraviolet Spectrograph (Juno-UVS)

Juno is the first polar orbiter around Jupiter. Juno possesses a suite of instruments designed to measure the electron and ion populations in the Jupiter magnetosphere, leading to the powerful Jovian aurorae. The Ultraviolet Spectrograph onboard Juno (Juno-UVS) is a photon-counting imaging spectrograph (68–210 nm), designed to observe and characterize Jupiter’s far-ultraviolet aurorae. The instrument borrows heavily from previous Alice and UVS instruments led by Southwest Research Institute (New Horizons and Rosetta Alices, LRO-LAMP), with several major improvements. The pointing flexibility offered by the UVS scan mirror combined with Juno’s spin allows UVS access to half of the sky at any given moment. This paper describes how we leverage this extensive database to track the evolution of Juno-UVS calibration with time throughout the mission. UVS observes 7.2° × 360°-long swaths of the sky for each rotation of the spacecraft (nominally 2 rpm). This paper describes how the very substantial amount of stellar spectra has been used to monitor the health of the instrument over the mission. As of PJ14 (2018 July 16), more than 8700 spectra of O, A, and B stars have been extracted in the V-magnitude range of ∼0–7, and more than 99% of the sky was mapped. Selected stars among this list were used to calibrate the UVS bandpass, using observations from the International Ultraviolet Explorer and the Hubble Space Telescope. The retrieved effective area of the instrument is 0.30 ± 0.03 cm{sup 2} at 125 nm, 0.15 ± 0.02 cm{sup 2} at 140 nm, and 0.05 ± 0.01 cm{sup 2} at 160 nm.

79 ASTRONOMY AND ASTROPHYSICS↗

Tantalum pentoxide: a new material platform for high-performance dielectric metasurface optics in the ultraviolet and visible region

Dielectric metasurfaces, composed of planar arrays of subwavelength dielectric structures that collectively mimic the operation of conventional bulk optical elements, have revolutionized the field of optics by their potential in constructing high-efficiency and multi-functional optoelectronic systems on chip. The performance of a dielectric metasurface is largely determined by its constituent material, which is highly desired to have a high refractive index, low optical loss and wide bandgap, and at the same time, be fabrication friendly. Here, we present a new material platform based on tantalum pentoxide (Ta 2 O 5 ) for implementing high-performance dielectric metasurface optics over the ultraviolet and visible spectral region. This wide-bandgap dielectric, exhibiting a high refractive index exceeding 2.1 and negligible extinction coefficient across a broad spectrum, can be easily deposited over large areas with good quality using straightforward physical vapor deposition, and patterned into high-aspect-ratio subwavelength nanostructures through commonly-available fluorine-gas-based reactive ion etching. We implement a series of high-efficiency ultraviolet and visible metasurfaces with representative light-field modulation functionalities including polarization-independent high-numerical-aperture lensing, spin-selective hologram projection, and vivid structural color generation, and the devices exhibit operational efficiencies up to 80%. Our work overcomes limitations faced by scalability of commonly-employed metasurface dielectrics and their operation into the visible and ultraviolet spectral range, and provides a novel route towards realization of high-performance, robust and foundry-manufacturable metasurface optics.

36 MATERIALS SCIENCE↗

The ultraviolet upturn in field luminous red galaxies at 0.3 < z < 0.7

ABSTRACT We derive the evolution of the ultraviolet upturn colour from a sample of field luminous red galaxies at 0.3 < z < 0.7 with −24 < Mr < −21.5. No individual objects are securely detected, so we stack several hundred galaxies within absolute magnitude and redshift intervals. We find that the colour of the ultraviolet upturn (in observed NUV − i which is approximately equivalent to the classical FUV − V at the redshifts of our targets) does not change strongly with redshift to z = 0.7. This behaviour is similar to that observed in cluster ellipticals over this same mass range and at similar redshifts, and we speculate that the processes involved in the origin of the UV upturn are the same. The observations are most consistent with spectral synthesis models containing a fraction of a helium rich stellar population with abundances between 37 per cent and 42 per cent, although we cannot formally exclude a contribution due to residual star formation at the $\sim 0.5\, \mathrm{ per\,cent}$ level (however, this appears unlikely for cluster galaxies that are believed to be more quenched). This suggests that the ultraviolet upturn is a primordial characteristic of early-type galaxies at all redshifts and that an unexpected nucleosynthesis channel may lead to nearly complete chemical evolution at early times.

79 ASTRONOMY AND ASTROPHYSICS↗

Deep-ultraviolet ptychographic pocket-scope (DART): mesoscale lensless molecular imaging with label-free spectroscopic contrast

The mesoscale characterization of biological specimens has traditionally required compromises between resolution, field-of-view, depth-of-field, and molecular specificity, with most approaches relying on external labels. Here we present the Deep-ultrAviolet ptychogRaphic pockeT-scope (DART), a handheld platform that transforms label-free molecular imaging through intrinsic deep-ultraviolet spectroscopic contrast. By leveraging biomolecules’ natural absorption fingerprints and combining them with lensless ptychographic microscopy, DART resolves down to 308-nm linewidths across centimeter-scale areas while maintaining millimeter-scale depth-of-field. The system’s virtual error-bin methodology effectively eliminates artifacts from limited temporal coherence and other optical imperfections, enabling high-fidelity molecular imaging without lenses. Through differential spectroscopic imaging at deep-ultraviolet wavelengths, DART quantitatively maps nucleic acid and protein distributions with femtogram sensitivity, providing an intrinsic basis for explainable virtual staining. We demonstrate DART’s capabilities through imaging of tissue sections, cytopathology specimens, blood cells, and neural populations, revealing detailed molecular contrast without external labels. The combination of high-resolution molecular mapping and broad mesoscale imaging in a portable platform opens new possibilities from rapid clinical diagnostics, tissue analysis, to biological characterization in space exploration.

60 APPLIED LIFE SCIENCES↗