Combinatorial Sensor Design in Caulobacter crescentus for Selective Environmental Uranium Detection

The ability to detect uranium (U) through environmental monitoring is of critical importance for informing water resource protection and nonproliferation efforts. Although technologies exist for environmental U detection, wide-area environmental monitoring, i.e. sampling coverage over large areas not known to possess U contamination, remains a challenging prospect that necessitates the development of novel detection approaches. In this work, we describe the development of a whole-cell U sensor by integrating two functionally independent, native U-responsive two-component signaling systems (TCS), UzcRS and UrpRS, within an AND gate circuit in the bacterium Caulobacter crescentus. Through leverage of the distinct but imperfect selectivity profiles of both TCS, this combinatorial approach enabled greater selectivity relative to a prior biosensor developed with UzcRS alone; no cross-reactivity was observed with most common environmental metals (e.g, Fe, As, Cu, Ca, Mg, Cd, Cr, Al) or the U decay-chain product Th, and the selectivity against Zn and Pb was significantly improved. In addition, integration of the UzcRS signal amplifier protein UzcY within the AND gate circuit further enhanced overall sensitivity and selectivity for U. The functionality of the sensor in an environmental context was confirmed by detection of U concentrations as low as 1 μM in groundwater samples. The results illustrate the value of a combinatorial approach for constructing whole-cell sensors for the selective detection of analytes for which there are no known evolved regulators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical spectroscopic tools for standoff uranium detection

Rapid and standoff analysis of uranium is important for many applications. We present the recent advances in standoff detection of uranium using emission and laser-induced fluorescence spectroscopy in conjunction with ultrafast laser filament ablation-based solid sampling.

(020.3260) Isotope shifts, (140.3440) Laser-induce↗

Uranium Detection - Technique Validation Report

As a LANL activity for DOE/NNSA in support of SHINE Medical Technologies™ ‘Accelerator Technology’ we have been investigating the application of UV-vis spectroscopy for uranium analysis in solution. While the technique has been developed specifically for sulfate solutions, the proposed SHINE target solutions, it can be adapted to a range of different solution matrixes. The FY15 work scope incorporated technical development that would improve accuracy, specificity, linearity & range, precision & ruggedness, and comparative analysis. Significant progress was achieved throughout FY 15 addressing these technical challenges, as is summarized in this report. In addition, comparative analysis of unknown samples using the Davies-Gray titration technique highlighted the importance of controlling temperature during analysis (impacting both technique accuracy and linearity/range). To fully understand the impact of temperature, additional experimentation and data analyses were performed during FY16. The results from this FY15/FY16 work were presented in a detailed presentation, LA-UR-16-21310, and an update of this presentation is included with this short report summarizing the key findings. The technique is based on analysis of the most intense U(VI) absorbance band in the visible region of the uranium spectra in 1 M H 2 SO 4 , at λ max = 419.5 nm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultrafast laser filament-induced fluorescence for detecting uranium stress in Chlamydomonas reinhardtii

Abstract Plants and other photosynthetic organisms have been suggested as potential pervasive biosensors for nuclear nonproliferation monitoring. We demonstrate that ultrafast laser filament-induced fluorescence of chlorophyll in the green alga Chlamydomonas reinhardtii is a promising method for remote, in-field detection of stress from exposure to nuclear materials. This method holds an advantage over broad-area surveillance, such as solar-induced fluorescence monitoring, when targeting excitation of a specific plant would improve the detectability, for example when local biota density is low. After exposing C. reinhardtii to uranium, we find that the concentration of chlorophyll a, chlorophyll fluorescence lifetime, and carotenoid content increase. The increased fluorescence lifetime signifies a decrease in non-photochemical quenching. The simultaneous increase in carotenoid content implies oxidative stress, further confirmed by the production of radical oxygen species evidence in the steady-state absorption spectrum. This is potentially a unique signature of uranium, as previous work finds that heavy metal stress generally increases non-photochemical quenching. We identify the temporal profile of the chlorophyll fluorescence to be a distinguishing feature between uranium-exposed and unexposed algae. Discrimination of uranium-exposed samples is possible at a distance of $$\sim $$ ∼ 35 m with a single laser shot and a modest collection system, as determined through a combination of experiment and simulation of distance-scaled uncertainty in discriminating the temporal profiles. Illustrating the potential for remote detection, detection over 125 m would require 100 laser shots, commensurate with the detection time on the order of 1 s.

54 ENVIRONMENTAL SCIENCES↗

Use of an ion mobility spectrometer for detecting uranium compounds

The safeguards community currently lacks a method to rapidly determine the chemical form of radioactive and non-radioactive compounds in real time during inspection activities. Chemical speciation identification can provide important information on both the types of materials that are collected during environmental sampling and can inform inspectors as to where to focus efforts during inspections or complementary access visits. Ion Mobility Spectrometry (IMS) is an established field technique for the detection of explosives, narcotics, and other organic compounds. More recently, electrospray ionization (ESI) has been used to introduce inorganic compounds to IMS instruments for analysis. These techniques have shown the ability to supply chemical information about the compounds being analyzed. Although these laboratory based instruments use a liquid-based injection system, there is evidence in the literature of unaltered and intact pharmaceutical tablets being volatilized and ionized in open atmosphere using heat and a Ni-63 source. Lastly, this work determined that a commercial-off-the-shelf (COTS) IMS could be used for the identification of solid uranium compounds directly after sampling using a COTS sample swipe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity analysis towards trace-uranium detection with γ-γ coincidence NAA

An improved approach for detection of trace amounts of 238 U by means of neutron activation analysis (NAA) is presented. The analysis enhancement is obtained by utilizing γ-γ coincidence counting. An empirical method for evaluating the sensitivity gain in the presence of a large source-related background is presented. A comparison of detection limits is made between two counting schemes; namely, counting single gammas using one HPGe detector versus counting coincident gammas using two HPGe detectors placed face-to-face. Furthermore, a data-validated radiation transport model, created in GEANT4 for a single HPGe detector, is extended to handle the two detector setup. In this counting scheme, a 238 U-detection sensitivity enhancement of about a factor of 8 is predicted for a sample of Saint-Gobain G3 Sapphire when compared to the simpler singles counting approach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of hexavalent uranium with inline and field-portable immunosensors

An antibody that recognizes a chelated form of hexavalent uranium was used in the development of two different immunosensors for uranium detection. Specifically, these sensors were utilized for the analysis of groundwater samples collected during a 2007 field study of in situ bioremediation in a aquifer located at Rifle, CO. The antibody-based sensors provided data comparable to that obtained using Kinetic Phosphorescence Analysis (KPA). Thus, these novel instruments and associated reagents should provide field researchers and resource managers with valuable new tools for on-site data acquisition.

54 ENVIRONMENTAL SCIENCES↗

Single-shot, multi-signature remote detection of uranium by filament-induced breakdown spectroscopy

Filament-induced breakdown spectroscopy (FIBS) is an attractive remote detection approach that is potentially applicable to nuclear materials, such as uranium (U). Simultaneous detection of atomic U and uranium monoxide features is demonstrated in a single laser shot with detection probabilities of 52.2% and 39.0%, respectively, and with a 1% false-alarm probability. It is shown that a nearly 100% detection probability can be reached with 1% false alarm probability in .1 second when using an 80-Hz laser and data acquisition system. Atomic U and UO signal features are identifiable in the remote measurement with comparable signal-to-background ratios, suggesting that, despite being broader than the U I emission line, the UO band is also suitable for remote detection of uranium by FIBS.

(020.3260) Isotope shifts, (140.3440) Laser-induce↗

Colorimetric detection of uranium in water

Disclosed are methods, materials and systems that can be used to determine qualitatively or quantitatively the level of uranium contamination in water samples. Beneficially, disclosed systems are relatively simple and cost-effective. For example, disclosed systems can be utilized by consumers having little or no training in chemical analysis techniques. Methods generally include a concentration step and a complexation step. Uranium concentration can be carried out according to an extraction chromatographic process and complexation can chemically bind uranium with a detectable substance such that the formed substance is visually detectable. Methods can detect uranium contamination down to levels even below the MCL as established by the EPA.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Detection of uranyl fluoride and sand surface contamination on metal substrates by hand-held laser-induced breakdown spectroscopy

Here, a hand-held device for laser-induced breakdown spectroscopy has been investigated for the determination of uranyl fluoride surface contamination. This research demonstrates the ability to successfully detect uranium on surfaces when using a low resolving power (λ/Δλ=4000) spectrograph, with a 5 mJ energy per 1 ns pulsed laser radiation, available as a commercially packaged hand-held system. Sand/uranyl fluoride mixtures are prepared to simulate residue likely encountered during decontamination efforts at facilities that handle uranium hexafluoride. Detection limits are described for four uranium lines with one revealing the capability to detect uranium at a level of 250 parts per million. Lastly, advantages of the studied compact device include that location specific information can be obtained on-site to augment contamination identification.

36 MATERIALS SCIENCE↗

Monochromatic wavelength dispersive x-ray fluorescence providing sensitive and selective detection of uranium

Monochromatic wavelength dispersive X-ray fluorescence (MWDXRF) is a sensitive and selective method for elemental compositional analyses. The basis for this instrumental advance is the doubly curved crystal (DCC) optic. Previous work has demonstrated the feasibility of sensitive trace element detection for yttrium as a surrogate for curium in aqueous solutions. Additional measurements have demonstrated similar sensitivity in several different matrix environments which attests to the selectivity of the DCC optic as well as the capabilities of the MWDXRF concept. The objective of this effort is to develop an improved Pu characterization method for nuclear fuel reprocessing plants. The MWDXRF prototype instrument is the second step in a multi-year effort to achieve an improved Pu assay. This work will describe a prototype MWDXRF instrument designed for uranium detection and characterization. The prototype consists of an X-ray tube with a rhodium anode and a DCC excitation optic incorporated into the source. The DCC optic passes the RhK{alpha} line at 20.214 keV for monochromatic excitation of the sample. The source is capable of 50 W power at 50 kV and 1.0 mA operation. The x-ray emission from the sample is collected by a DCC optic set at the UL{alpha} line of 13.613 keV. The collection optic transmits the UL{alpha} x-rays to the silicon drift detector. The x-ray source, sample, collection optic and detector are all mounted on motion controlled stages for the critical alignment of these components. The sensitivity and selectivity of the instrument is obtained through the monochromatic excitation and the monochromatic detection. The prototype instrument performance has a demonstrated for sensitivity for uranium detection of around 2 ppm at the current state of development. Further improvement in sensitivity is expected with more detailed alignment.

47 OTHER INSTRUMENTATION↗

Prompt Photofission Neutron Detection in Depleted Uranium

The detection of prompt photofission neutrons during active interrogation is a strong indication of the presence of special nuclear materials. However, the high-energy photons used for interrogation create a very challenging radiation environment for the detection of prompt fission signatures. These challenges include detector saturation and pulse pile-up. Additionally, there is an elevated neutron background that further challenges the detection of prompt fission neutrons. This background is produced because of (γ, Xn) photonuclear reactions in the surrounding high-Z materials. Here, we demonstrate the detection of prompt photofission neutrons in these challenging environments. Depleted uranium (DU) and lead targets are interrogated with bremsstrahlung photons produced by a 9-MV electron linear accelerator. Fast neutrons are detected with trans-stilbene organic detectors, and scintillation pulses are analyzed using a previously developed and demonstrated artificial neural network system. We observe a 5 times higher photoneutron count rate when the lead target is replaced with the DU target. Additionally, we observe a difference in the photoneutron light-output distributions of lead and DU. Here, this difference in the measured distributions is due to the difference in the photoneutron-energy spectra; DU photoneutrons are emitted with (γ, n) and watt-energy spectra, whereas lead photoneutrons are emitted with only the (γ, n) spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Remote Detection of Uranium Using Self-Focusing Intense Femtosecond Laser Pulses

Optical measurement techniques can address certain important challenges associated with nuclear safety and security. Detection of uranium over long distances presents one such challenge that is difficult to realize with traditional ionizing radiation detection, but may benefit from the use of techniques based on intense femtosecond laser pulses. When a high-power laser pulse propagates in air, it experiences collapse and confinement into filaments over an extended distance even without external focusing. In our experiments, we varied the initial pulse chirp to optimize the emission signal from the laser-produced uranium plasma at an extended distance. While the ablation efficiency of filaments formed by self-focusing is known to be significantly lower when compared to filaments produced by external focusing, we show that filaments formed by self-focusing can still generate luminous spectroscopic signatures of uranium detectable within seconds over a 10-m range. The intensity of uranium emission varies periodically with laser chirp, which is attributed to the interplay among self-focusing, defocusing, and multi-filament fragmentation along the beam propagation axis. Grouping of multi-filaments incident on target is found to be correlated with the uranium emission intensity. The results show promise towards long-range detection, advancing the diagnostics and analytical capabilities in ultrafast laser-based spectroscopy of high-Z elements.

42 ENGINEERING↗

Detection of uranium in solids by using laser-induced breakdown spectroscopy combined with laser-induced fluorescence

Detection of uranium in solids by using laser-induced breakdown spectroscopy has been investigated in combination with laser-induced fluorescence. An optical parametric oscillator wavelength-tunable laser was used to resonantly excite the uranium atoms and ions within the plasma plumes generated by a Q-switched Nd:YAG laser. Both atomic and ionic lines can be selected to detect their fluorescence lines. A uranium concentration of 462 ppm in a glass sample can be detected by using this technique at an excitation wavelength of 385.96 nm for resonant excitation of U II and a fluorescence line wavelength of 409.0 nm from U II.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Parts per billion detection of uranium with a porphyrinoid-containing nanoparticle and in vivo photoacoustic imaging

Chemical tools that can report radioactive isotopes would be of interest to the defense community. Here in this paper we report –250 nm polymeric nanoparticles containing porphyrinoid macrocycles with and without pre-complexed depleted uranium and demonstrate that the latter species may be detected easily and with high sensitivity via photoacoustic imaging. The porphyrinoid macrocycles used in the present study are non-aromatic in the absence of the uranyl cation, but aromatic after cation complexation. We solubilized both the freebase and metalated forms of the macrocycles in poly(lactic-co-glycolic acid) and found a peak in the photoacoustic spectrum at 910 nm excitation in the case of the uranyl complex. The signal was stable for at least 15 minutes and allowed detection of uranium concentrations down to 6.2 ppb (5.7 nM) in vitro and 0.57 ppm (19 fCi; 0.52 μM) in vivo . Furthermore, to the best of our knowledge, this is the first report of a nanoparticle that detects an actinide cation via photoacoustic imaging.

36 MATERIALS SCIENCE↗

Standoff Detection of Uranium and its Isotopes by Femtosecond Filament Laser Ablation Molecular Isotopic Spectrometry

The ability to perform not only elementally but also isotopically sensitive detection and analysis at standoff distances is important for remote sensing applications in diverse ares, such as nuclear nonproliferation, environmental monitoring, geophysics, and planetary science. We demonstrate isotopically sensitive real-time standoff detection of uranium by the use of femtosecond filament-induced laser ablation molecular isotopic spectrometry. A uranium oxide molecular emission isotope shift of 0.05 ± 0.007 nm is reported at 593.6 nm. We implement both spectroscopic and acoustic diagnostics to characterize the properties of uranium plasma generated at different filament- uranium interaction points. The resulting uranium oxide emission exhibits a nearly constant signal-to-background ratio over the length of the filament, unlike the uranium atomic and ionic emission, for which the signal-to-background ratio varies significantly along the filament propagation. This is explained by the different rates of increase of plasma density and uranium oxide density along the filament length resulting from spectral and temporal evolution of the filament along its propagation. Lastly, the results provide a basis for the optimal use of filaments for standoff detection and analysis of uranium isotopes and indicate the potential of the technique for a wider range of remote sensing applications that require isotopic sensitivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Surface Modification of Silicon Pillar Arrays To Enhance Fluorescence Detection of Uranium and DNA

There is an ever-growing need for detection methods that are both sensitive and efficient, such that reagent and sample consumption is minimized. Nanopillar arrays offer an attractive option to fill this need by virtue of their small scale in conjunction with their field enhancement intensity gains. This work investigates the use of nanopillar substrates for the detection of the uranyl ion and DNA, two analytes unalike but for their low quantum efficiencies combined with the need for high-throughput analyses. Here in this paper, the adaptability of these platforms was explored, as methods for the successful surface immobilization of both analytes were developed and compared, resulting in a limit of detection for the uranyl ion of less than 1 ppm with a 0.2 μL sample volume. Moreover, differentiation between single-stranded and double-stranded DNA was possible, including qualitative identification between double-stranded DNA and DNA of the same sequence, but with a 10-base-pair mismatch.

36 MATERIALS SCIENCE↗