Search NASA⌕ Search

SEARCH · Search NASA

Results for “Uranium concentration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Quantifying uncertainty in uranium concentration measurements via K-edge densitometry

This study quantifies the uncertainty in uranium concentration predictions of fluoride and chloride-based salts within a steel pipe using K-edge densitometry. Modeling and simulation was conducted with the Monte Carlo N-Particle Transport (MCNP) code. The quality of of this technique’s prediction in a pipe requires proper characterization of the pipe’s thickness, which is dependent on the source size and axial offset from the pipe centerline. The thickness was determined as either the center-line thickness seen by the X-ray source or an average value determined through random sampling. Generally, the predicted concentrations were slightly better at lower offset with the random sampling thickness and using the center-line thickness for the highest offsets. For a line-beam source and varying axial offsets, the relative error of concentration was within 1% of the true value but uncertainty increased by 2 orders of magnitude. Similarly, for no axial offset, the relative error was significantly less than 1% while no trend for uncertainty was found. However, at the largest possible offset for a given source size, the concentrations become erroneous and greater than the allowable 1% relative error. Furthermore, high offsets tended to increase the variance of the transmission spectra by 3 orders of magnitude.

Characterization and Analytical Technique↗

Characterizing microscale signatures in uranium ore concentrates using electron probe microanalyzer

Impurities in uranium ore concentrates (UOCs) serve as forensic signatures of processing history and origin. Here, this study utilizes Electron Probe Microanalyzer (EPMA) to characterize microscale compositional and textural features in individual UOC particles from both commercial and bench-scale production. At the particle scale, multiple internal phases with distinct morphologies, chemical signatures, and stoichiometries are documented. Our data shows that chemical impurities are heterogeneously distributed within single particles and among particles within a sample. These microscale heterogeneities correlate with known processing histories, indicating that microscale signatures of early fuel cycle materials can provide valuable information for nuclear forensic material analysis.

organic↗

Neutron capture signatures determined from gadolinium isotope compositions of uranium ore concentrates using MC-ICPMS

We present Gd isotope compositions on 25 well-characterized uranium ore concentrates (UOCs). About half the UOCs have isotope depletions in 157 Gd coupled with anticorrelated excesses in 158 Gd due to neutron capture effects. UOCs from older ore bodies and with higher U contents show larger neutron capture effects than UOCs from younger ore bodies with lower U contents. These Gd data are correlated with their previously measured Sm isotope compositions, and we use the Sm data to estimate the neutron fluence of these samples. In conclusion, this work demonstrates how Gd isotope signatures can be employed as a new tool for nuclear forensics.

Earth Sciences↗

Nuclear forensic analysis on uranium ore concentrates: A multi-laboratory intercomparison study

A collaboration between the United States and Japan performed nuclear forensic analyses on a set of 7 uranium ore concentrate (UOC) samples with known origins to improve methodologies and best practices in the field. Overall, good agreement between the 4 participating laboratories was achieved for uranium assay, uranium isotope composition, strontium isotope composition, and trace element analysis. In conclusion, the combination of these four signatures is sufficient to distinguish the different origins among these studied UOCs.

and nuclear chemistry↗

Application of Raman Spectroscopy to Determine Uranium Content in ADUN Solution

The work presented in this report is part of the ongoing efforts to address the nuclear material control and accounting needs for advanced reactor fuel fabrication facilities. This work was supported by the Materials Protection, Accounting, and Control Technologies (MPACT) program under the US Department of Energy Office of Nuclear Energy‘s Nuclear Fuel Cycle and Supply Chain program. The activities and engagements under the MPACT program are designed to support a robust US civilian nuclear energy enterprise. In the work described in this report, we supported MPACT objectives by developing measurement techniques that could be used for material accounting and process monitoring and by working with industry partners to identify existing gaps and areas for improvement. Oak Ridge National Laboratory has been working with commercial tristructural isotropic (TRISO) fuel fabricators such as Standard Nuclear to develop technology for rapid and cost-effective uranium content assessment. This work has focused on demonstrating advanced measurement techniques (e.g., Raman spectroscopy) that can be used for rapid, reliable, and cost-effective routine measurements of uranium content in feed solutions and liquid waste streams as well as for monitoring in-line process measurements and product streams. Specifically, this report explores techniques for accurately determining uranium content in acid-deficient uranyl nitrate (ADUN) solutions and detecting low uranium concentrations in ammonia solutions. Developing such measurement techniques will benefit TRISO fuel fabrication facilities, facilities involved in other parts of the fuel cycle that require online monitoring of aqueous solutions, and potentially molten salt fuel reactors. This work supports developing Raman spectroscopy procedures to determine uranium concentrations in ADUN solutions, which are used as feedstock in the sol–gel process for creating TRISO fuel. Some additional benefits of using Raman spectroscopy for uranium quantification in fabrication facilities include enabling online monitoring of the chemical process, which would provide near real-time feedback; eliminating the need for sample transfers, preparation, or dilution; providing nondestructive measurements; and user friendliness. In this fiscal year, FY25, we determined the identity of the unknown Raman band at approximately 853 cm−1 that was discovered in ADUN Raman spectra in FY24, created calibration curves and determined uranium concentrations of two ADUN solutions, and compared the Raman results to results obtained from inductively coupled plasma mass spectrometry and Davies–Gray titration. Furthermore, we have identified focus areas for experimentation in future fiscal years. A key result is that the accuracy of using Raman can provide accuracy comparable to destructive analysist techniques, With a well-developed calibration curve, using standards and a large number of samples (more than five samples), uncertainty on the order of 1%–3% is achievable. Given that the uncertainties achieved by Raman spectroscopy were on the order of the uncertainties achieved using ICP-MS, we conclude that with a well-developed procedure Raman spectroscopy can be used to determine uranium concentrations in ADUN solutions for NMC&A applications. The benefits of such an approach are that the time and effort will be less than that of comparable destructive analysis techniques, with approximately the same level of technical expertise. This will be attractive to operators of fuel fabrication facilities as it will lower costs and improve efficiencies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Progress Towards Synthesis of Uranium Chloride Fuel Salts Using Zinc Chloride

Reliable, scalable methods for producing high-purity actinide chloride salts are needed to support molten salt reactor fuel development and deployment. This report describes the continued development and demonstration of a bench-scale chlorination and purification apparatus using a zinc chloride-based method for synthesizing uranium chloride fuel salts. In this approach, uranium metal is chlorinated by ZnCl2 to produce LiCl-KCl-UCl3. Reaction with three aliquots of added uranium metal was used to generate a target uranium concentration of 30 wt %. While this concentration was chosen for initial testing of the apparatus and method, the final uranium concentration is not limited to 30 wt %. The zinc metal generated in the reaction forms an immiscible layer that was removed by volatilization at moderately high temperatures. Electrochemical measurements confirmed the removal of zinc and applied sensing methods indicated the uranium concentration to be approximately 25 wt %. These initial results demonstrate that the bench-scale chlorination apparatus is an effective platform for the synthesis and purification of uranium chloride salts using ZnCl2. This method shows promise for application to industry-relevant salt systems such as NaCl-UCl3. Further development is recommended to optimize reagent loading, zinc removal, and avoid possible U-Zn alloy formation.

Dulovic, Stephanie↗

Sample screening of uranium ore concentrates using portable spectrophotometers: investigating the correlation between visible colors and chemical signatures

A research collaboration between the Japan Atomic Energy Agency and the Department of Energy’s National Nuclear Security Administration examined nuclear forensic signatures and analytical methods for tracing the origins of uranium ore concentrates (UOCs). Here, this study focuses on utilizing portable spectrophotometers capable of reflectance measurements in the visible light spectrum as a potential rapid screening tool for nuclear forensics analysis. Unlike laboratory-based near-infrared spectroscopy or digital image analysis, this research investigated the potential to correlate visible color measurements with key nuclear forensics signatures using seven types of UOC samples with known origins and three UOC certified reference materials. Results demonstrated that distinct color groups, quantified using CIELAB values, correlated with major uranium compounds. Furthermore, the findings indicated that trace elements can influence the UOC colors, providing additional insights into material characteristics. Although this approach requires further validation across a broader range of UOC species, this study demonstrated that simple colorimetric analysis using visible spectrophotometry, which does not require complex sample preparation or data processing, can serve as a practical and novel rapid tool for preliminary screening and attribution in nuclear forensics investigations.

and nuclear chemistry↗

Rhenium Isotope Reconnaissance of Uranium Ore Concentrates

Exploration of natural isotopic variations of the element rhenium (Re) is in its infancy, with initial studies revealing isotopic fractionation in a variety of geological materials. Here, in this work, we investigate Re isotope variation as a new geochemical tool, given its redox-sensitive properties and affinity for organic matter and sulfides. In this work, Re abundance and isotope ratio data were collected from uranium ore concentrates (UOCs) across a variety of depositional ages, locations, geologic settings, and deposit types. Ore types from which the UOC were derived include sandstone, unconformity, and quartz-pebble (QP) conglomerate. To isolate Re from the U-rich matrix of UOCs, a new purification method utilizing DGA ion exchange resin was developed. We found that UOCs exhibit a wide range of Re isotope ratios, with sandstone ore-derived UOCs having the isotopically lightest values, QP conglomerate ore-derived UOCs having the heaviest, and unconformity ore-derived UOCs in between (with some overlap with sandstone UOCs). The Re isotope ratio range observed in UOCs extends previously reported values by more than a factor of two. Industrial processing (e.g., incomplete recovery of Re from ore, contamination, fractionation during processing) may play a role in the isotopic variability in the UOCs. However, systematic differences between ore types suggest that the depositional setting is a significant factor. For nuclear forensic investigations, Re isotopic compositions combined with data from other isotopic systems provide geochemical signatures that can aid in provenance assessment of UOCs. Regardless of the specific causes for the wide range of Re isotope ratios in UOCs, these initial data indicate Re is a promising tool for nuclear forensic investigations on samples from early in the nuclear fuel cycle.

58 GEOSCIENCES↗

A case study on the use of carbon sticky tabs for microbeam uranium isotope measurement with an emphasis on understanding the influence of subtle variations in substrate composition

In this paper we integrate laser induced breakdown spectroscopy (LIBS), large geometry secondary ion mass spectrometry (LG-SIMS), laser ablation—multi collector—inductively coupled plasma—mass spectrometry (LA-MC-ICP-MS), and trace elemental compositions obtained by bulk digestion from a suite of commercially available carbon sticky tabs to determine if subtle variations in the tab’s composition can be tied to shifts in the observed uranium isotopic composition of the IRMM-2020 standard relative to its ‘true’ value. The results suggest that, although clear differences exist in the relative abundances of carbon and hydrogen across the various carbon sticky tabs examined, as well as differences in their trace elemental and total uranium concentrations, these differences do not appear to influence the LG-SIMS or LA-MC-ICP-MS uranium isotope ratio measurements, or the appearance of the uranium mass spectrum scans. Instead, the quality (i.e., precision and accuracy) of the LG-SIMS and LA-MC-ICP-MS results are directly proportional to the observed signal intensity at the time of analysis. For the LG-SIMS measurements, there does appear to be a direct correlation between 235U1H hydride formation rates and vacuum conditions within the instrument’s analytical chamber. Furthermore, none of the carbon sticky tabs examined by LG-SIMS displayed evidence of elevated background uranium content. While a preliminary correlation was observed between the uranium isotope background signal during LA-MC-ICP-MS and the total uranium concentrations determined by isotope dilution, none of the tabs displayed a high enough analytical background to affect the isotope ratio measurements.

Zirakparvar, Alex [ORNL] (ORCID:0000000337797730)↗

Out-of-distribution detection with non-parametric density estimation for models predicting processing history of uranium ore concentrates

The rapid advancement in machine learning (ML) and computer vision (CV) coincides with the growth of interest in deploying these ML/CV models in numerous fields from medicine to social science. Similar to those areas, we have witnessed a great number of works in materials science employing ML/CV models – neural networks in particular – in their studies in recent years. These models have proven to obtain accurate performance in various tasks. However, these models struggle to attain a similar performance when encountering test samples coming from a distribution that is different from the training set. More importantly, they fail without providing any warning to the users. Therefore, we propose a framework for detecting out-of-distribution (OOD) samples to alert users when a human intervention might be necessary in this work. Specifically, we explore the use of a non-parametric density estimation method to detect OOD samples. Here, we assess OOD detection capability of the proposed framework on ML models developed for categorizing precipitation routes of U 3 O 8 when encountering OOD datasets that contain samples (1) undergone different imaging acquisition process, (2) undergone different material synthesis process, and (3) different materials than ID set. Through those experiments, we achieve an average area under the receiver operating characteristic (AUROC) of at least 91% on average in detecting OOD samples. With minimal overhead cost and superior performance, the proposed framework enables a reliable and safe system when deploying in real-world scenarios.

Convolutional neural networks↗

Optical vibrational spectroscopic signatures related to U 3 O 8 production processes

Uranium ore concentrates are materials found early within the nuclear fuel cycle and contain high concentrations of uranium in an easily transported form, making the concentrates a likely target for illegal diversion. These concentrates are typically converted to U 3 O 8 for further processing and, therefore, may lose specific physicochemical characteristics in determining the materials’ source and processing history. In this work, we explore the Raman spectra of eight oxide samples produced from various uranium ore concentrates and processing pathways to examine the presence of spectroscopic signatures relating to each sample's process history. Samples produced from amine extraction and dialkylphosphoric acid extraction processes show unique characteristics due to high concentrations of α-UO 3 , whereas samples calcinated from metallic diuranates do not form pure α-U 3 O 8 because of metallic ion inclusions. Pure α-U 3 O 8 oxide samples are obtained through calcination of ammonium diuranate, ammonium uranyl carbonate, and metastudtite intermediates. The Raman spectra of these oxide samples show close agreement with pristine α-U 3 O 8 spectra. However, deviations from the pristine spectra are observed in the 300–460 cm -1 spectral range. In conclusion, these deviations are unique identifying signatures that were likely created by lasting effects from the process history. Spectral center of mass calculations indicate grouping of samples based on processing history.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Synthesis and characterization of uranium trichloride in alkali-metal chloride media

Given a growing interest in uranium salts for pyrochemical processing of used fuel and uranium-fueled molten salt reactors, the synthesis of uranium trichloride in alkali-metal chloride media was investigated in a series of four experiments. Specifically, uranium metal powder and uranium hydride powder were prepared and separately blended with ammonium chloride and lithium chloride – potassium chloride eutectic in two runs, while the same powders were separately blended with ammonium chloride and sodium chloride in two additional runs. Each of the lithium chloride – potassium chloride containing blends was slowly heated to 923 K, while those containing sodium chloride were heated to 1123 K. During each heat up, the ammonium chloride sublimed into gaseous ammonia and hydrogen chloride, leading to the chlorination of uranium metal or uranium hydride and the formation of molten salt solutions of the respective chlorides. Experimental conditions were incorporated in the runs to promote formation of uranium trichloride over uranium tetrachloride in the respective media. Molten samples of each run product were taken and characterized via chemical analyses, diffractometry, and microscopy. The final products from each run were dark dense ingots of the respective salt systems with uranium concentrations ranging from 44 to 51 wt%. Chemical analyses and diffractometry identified the predominant presence of uranium trichloride in these systems; however, a possible minor presence of uranium tetrachloride could not be conclusively dismissed.

D Herrmann, Steven↗

Quantitative Voltammetry Measurements of High-Concentration Actinides in Molten Chloride Fuel Salts

Molten chloride mixtures containing high concentrations of UCl 3 (i.e., >70 wt%) are candidates for next-generation molten salt reactor (MSR) fuel salts that enable new plant optimization and fuel cycle strategies. MSR licensing, however, is contingent on the development of effective material control and accounting (MC&A) practices for these salts. To close this gap, we have developed an electroanalytical approach that enables accurate in situ measurements of uranium concentrations in these highly loaded fuel salts. This methodology uses a multielectrode array voltammetry sensor combined with digital simulations that account for non-idealities such as uncompensated resistance effects. The theory-based numerical simulations of voltammetry responses yielded correction factors that are agnostic of electrochemical cell geometry and produced consistent voltammetry peak current results when correcting for varying amounts of ohmic resistance. In doing so, we have demonstrated accurate concentration measurements for UCl 3 in LiCl-KCl-UCl 3 across a range of mass fractions between 55 and 72.3 wt% at 550 °C.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Adapting Nuclear Forensics from Light Water to Molten Salt Reactors: A Survey of Emerging Needs

Rising interest in molten salt reactors for commercial power production presents an opportunity to evaluate the techniques used to characterize materials of nuclear forensic interest. Since extensive research has been performed to identify and develop signatures of light water reactor (LWR) materials (e.g. uranium ore concentrates and uranium dioxide fuel pellets), we use this as a basis to explore possibilities for molten salt signature development. Through this comparative method, nuclear forensic signatures used today to identify the provenance of nuclear materials found out of regulatory control are adapted to molten salt reactor (MSR) fuel cycle materials. Radiological, elemental composition, isotopic composition, and model age signatures will likely not need large adaptations before being applied to MSR materials but may need to expand to be applicable to both thorium- and uranium-fueled systems. The liquid nature of molten salt fuel may erase signatures related to production and irradiation history that are informative for typical LWR materials. However, it may also lead to opportunities for new signatures, such as cooling rate–controlled morphology. Targets identified for further research include radiological attributes of fuel salts; elemental, chemical, and isotopic analysis of salts with differing production routes; morphological effects of various thermodynamic environments; and relevant fuel cycle radiochronometers. Additionally, the comparative nature of the proposed signatures implies a need for MSR-relevant databases and the production of salt standard reference materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Impact of dynamic Jahn-Teller effect on magnetic excitations, lattice vibration, and thermal conductivity in U 𝑥 ⁢T⁢h 1−𝑥 ⁡O 2 system

Vibrational and magnetic properties of single-crystal uranium-thorium dioxide (U 𝑥 ⁢T⁢h 1−𝑥⁡ O 2 ) with a full range of 0 < 𝑥 < 1 are investigated. Thorium dioxide is a diamagnet whose thermal properties are governed by lattice vibration. The addition of paramagnetic uranium ions leads to the emergence of magnetic effects that alter the thermophysical properties noticeably even at room temperature. The interaction of phonons with magnetic moments of uranium 5⁢𝑓 electrons mediated by magnetoelastic coupling results in an anomalous low-temperature thermal conductivity profile. Analysis of the magnetic susceptibility measurements indicates a departure from the Curie-Weiss relationship characteristic of noninteracting paramagnetic ions, previously associated with the dynamic Jahn-Teller (DJT) effect characterized by coupling between spin and the oxygen sublattice. The T 2⁢g Raman peak position follows a nonlinear trend as a function of uranium concentration and hints that these Raman active optical modes play a role in either DJT or in mediating quadrupole-quadrupole interactions. A first-principle-based thermal transport model is implemented to explain the low-temperature transport measurements, where the anomalous reduction is attributed to phonon-spin resonant scattering. The interplay between spins and phonons is also captured using high-resolution inelastic x-ray scattering (IXS) measurements of phonon linewidths. Our results provide insights into the phonon interactions with the magnetic excitations governing DJT effect and impacting the low-temperature thermal transport processes in this material system. Furthermore, these findings have implications for understanding low-temperature thermal transport and magnetic properties in advanced materials for information processing and energy applications.

36 - MATERIALS SCIENCE↗

Comparison of the sensitivity of 236 U measurements in environmental samples by MC-ICP-MS and ATONA based high precision U TIMS measurements

The ATONA project is focused upon exploring the improvements in uranium isotope ratio measurements by thermal ionization mass spectrometry (TIMS) provided by a new, capacitor-based, amplifier technology. These “ATONA” Faraday amplifiers (Isotopx Ltd, UK) promise accurate, low-noise measurements of very small signals (< 1 femto-amp) in a traditional Faraday cup, which was only previously possible using an ion counter. This report outlines a series of experiments that were performed to assess the performance of the system in samples that test our rapid analysis procedures, and then compare the results against other mass spectrometry techniques currently available for environmental analyses. The following major goals were achieved: (1) illustrated the importance of 236 U measurements for the screening and analysis of environmental samples; (2) improved sensitivity for 236 U, and then identified 236 U in the 4350B standard at ultra-trace levels (3) Provided comparison of the 236 U sensitivity to multi-collector inductively coupled mass spectrometry techniques (4) Illustrated high TRL for the ATONA based measurement technique. This completes the reporting requirements for task 4 in the project LCP and highlights the utility of the system to make highly sensitive 236 U measurements in programmatically relevant sample matrices and at relevant uranium concentrations.

07 ISOTOPE AND RADIATION SOURCES↗

Development of an L-Edge X-ray Absorbance Spectrometer for Monitoring Dissolver Solutions in H-Canyon

Savannah River National Laboratory has developed a monitor to measure plutonium and uranium concentrations in solutions of dissolved nuclear fuel. The monitor will be installed in the sample aisle location for the 6.3D Dissolver in the Savannah River Site’s H-Canyon and used in support of the electrolytic dissolution such as Fast Critical Assembly fuel. The monitor is based on the atomic absorbance of x-rays. Elements are differentiated by the appearance of absorbance features at specific energies of the x-ray spectrum that correspond to L-edge transitions of inner core electrons. Hence, the technique is called L-Edge X-Ray Absorbance Spectroscopy (L-XRAS). The technique is suitable for nuclear fuel processing due to its relative insensitivity to other components of the dissolver solution, such as nitric acid, transition metals (Fe, Cr, Ni, Mn) such as those from stainless steel, particulates, and catalysts and additives. The instrumentation consists of a commercially available x-ray source and detector, a sample cell designed to interface with the airlift sampler associated with H-Canyon Tank 6.3D, and a stainless steel enclosure. SRNL wrote instrument control software and developed chemometric models to interpret x-ray intensity spectra and estimate analyte concentrations and uncertainties in real time.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Method for Producing Hierarchical and Statistically Calibrated Predictions of Nuclear Material Properties from Existing Models

Computer vision-based analysis of micrographs of nuclear materials is an emerging technique for property prediction, synthetic route identification, and other material analysis tasks. These analysis tasks play a pivotal role in many material characterization applications such as signature development for treaty verification, process optimization, etc. The backbone in many of the recent computer vision-based techniques is a deep learning model, which takes a fixed-size set of pixels and provides a class prediction for that set of pixels. For example, previous work developed a deep convolutional neural network (CNN) to predict the synthetic route from a 256 px x 256 px patch taken from a larger image of uranium ore concentrates. In this work, we present several methods for first calibrating these models in a manner that they can provide accurate probabilities of their predictions’ veracity, and several methods of combining these probabilities. Overall, the combination of these two steps into a pipeline allows for full-image and even full-sample (where a sample has many images) predictions with associated confidence values. Finally, we show that one can also use the patch predictions and confidence to produce a visualization to map predicted constituents through the image. Results and examples for predicting and mapping uranium ore concentrates’ synthetic process from imagery will be presented.

artificial intelligence↗