Search NASA⌕ Search

SEARCH · Search NASA

Results for “Urban ventilation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Data-driven model for cross ventilation potential in high-density cities based on coupled CFD simulation and machine learning

Effective urban ventilation through decent urban planning and building design can alleviate the deterioration of the urban built environment. Furthermore, natural ventilation requirements and guidelines in current building codes and standards are either qualitative or quantitative but subject to an absolute indoor airspeed threshold without considering the outdoor wind environment. To fill this gap, this paper develops an urban-scale coupled indoor and outdoor computational fluid dynamics (CFD) model and defines a novel ventilation index to assess natural ventilation potential. The index considers wind environments of both indoor and outdoor spaces.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of the impact of dipped guideways on urban rail transit systems: Ventilation and safety requirements

The ventilation and fire safety requirements for subway tunnels with dipped profiles between stations as compared to subway tunnels with level profiles were evaluated. This evaluation is based upon computer simulations of a train fire emergency condition. Each of the tunnel configurations evaluated was developed from characteristics that are representative of modern transit systems. The results of the study indicate that: (1) The level tunnel system required about 10% more station cooling than dipped tunnel systems in order to meet design requirements; and (2) The emergency ventilation requirements are greater with dipped tunnel systems than with level tunnel systems.

Source record↗

Embedding Climate Change in Urban Planning and Urban Design in New York City

Confronting the challenges of a rapidly urbanizing world threatened by climate change requires expanding the traditional influence and capabilities of urban planning and urban design, integrating climate science, natural systems and compact urban form to configure dynamic, desirable and healthy communities. Cost-effective planning and design measures that help mitigate emissions while bringing adaptive benefits should be prioritized. The chapter draws from the publication Climate Change and Cities (Cambridge University Press 2018) by the Urban Climate Change Research Network (UCCRN). The two-phase New York City case study by the Urban Design Climate Lab at the New York Institute of Technology and a team of international urban design climate experts illustrates how this emerging expertise can be replicated and implemented worldwide. Its focus on configuring people-centered public spaces that enhance energy efficiency and improve public health draws from four urban climate factors: improving efficiency of urban systems, both in energy and transportation; optimizing the form and layout of urban districts to enhance ventilation; promoting appropriate building materials with high reflectivity; and increasing green and blue urban infrastructure. The chapter highlights a set of tools and methods to measure success.

Resiliency↗

Observations of airflow around a supertall curved building and its impact on temperature and humidity in Houston's urban center

Characterization of realistically shaped skyscrapers embedded in non-uniform neighbourhoods experiencing intricate weather patterns remains inadequately investigated. Aiming to close this gap, the Center for Multiscale Applied Sensing team deployed its mobile observatory in the street canyons around the curved Wells Fargo Plaza skyscraper in downtown Houston, TX. Three deployments allowed airflow observations under different inflow wind and thermodynamic stability conditions. Doppler lidar measurements reveal that when inflow hits the curved wall of the skyscraper, perpendicular canyons experience similar vortex configurations creating two windward and two leeward circulations. Windsond measurements support that buoyancy within the deep street canyons can generate thermal updrafts as strong as 2 m s -1 which is sufficient to overturn the mechanical downwash under gentle wind conditions. Canyons experiencing venting during the daytime were observed to be more thermodynamically stable at night while thermodynamically stable canyons during the day were observed to be more thermodynamically unstable at night owing to the accumulation of heat near street-level. Fourier decomposition of the vertical velocity measurements shows that in all cases flow exhibited high Reynolds numbers and was composed of turbulent eddies of predominantly 6 and 15 min periods. Here, this observational dataset provides insights to assess wind load, pedestrian comfort, urban air mobility, and natural ventilation and may be used as a benchmark for numerical model and wind tunnel studies attempting to represent realistically complex urban conditions.

54 ENVIRONMENTAL SCIENCES↗

Regional difference and related cooling electricity savings of air pollutant affected natural ventilation in commercial buildings across the US

Maintaining indoor air pollutants under acceptable levels is significant to protect occupants from exposure to excessive air pollutants in natural ventilation. In this paper, using the representative air pollutant concentration data, we present the natural ventilation usability with associated cooling energy saving potentials in different location settings (urban and city center, suburban and rural) of the US under the influence of local weather conditions and major outdoor air pollutants, i.e. PM2.5, PM10 and ozone. It is found that the impacts of air pollutants on natural ventilation are usually higher in urban/suburban areas than rural areas (up to 25% difference) with the PM2.5 being the most significant outdoor air pollutant affecting natural ventilation usage. Furthermore, ozone could become increasingly influential on natural ventilation as moving from urban to suburban/rural areas. As to the cooling energy saving considering the impacts of outdoor air pollutants, natural ventilation is estimated to save approximately 10%–40% cooling energy (800–2600 kWh per small commercial building) annually in different location settings of investigated areas across the US. The following economic analysis demonstrates that these electricity savings lead to approximately 80–540 dollars annual savings of building operation cost per building. If the time of use rate is adopted, these cost savings could further increase by approximately 20% (Los Angeles) to more than 50% (Albuquerque) depending on different rate structures, which further demonstrates the potential of adopting natural ventilation as a sustainability measurement with benefits for building owners without compromising occupants health.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effects of Solar Photovoltaic Panels on Roof Heat Transfer

Building Heating, Ventilation and Air Conditioning (HVAC) is a major contributor to urban energy use. In single story buildings with large surface area such as warehouses most of the heat enters through the roof. A rooftop modification that has not been examined experimentally is solar photovoltaic (PV) arrays. In California alone, several GW in residential and commercial rooftop PV are approved or in the planning stages. With the PV solar conversion efficiency ranging from 5-20% and a typical installed PV solar reflectance of 16-27%, 53-79% of the solar energy heats the panel. Most of this heat is then either transferred to the atmosphere or the building underneath. Consequently solar PV has indirect effects on roof heat transfer. The effect of rooftop PV systems on the building roof and indoor energy balance as well as their economic impacts on building HVAC costs have not been investigated. Roof calculator models currently do not account for rooftop modifications such as PV arrays. In this study, we report extensive measurements of a building containing a flush mount and a tilted solar PV array as well as exposed reference roof. Exterior air and surface temperature, wind speed, and solar radiation were measured and thermal infrared (TIR) images of the interior ceiling were taken. We found that in daytime the ceiling surface temperature under the PV arrays was significantly cooler than under the exposed roof. The maximum difference of 2.5 C was observed at around 1800h, close to typical time of peak energy demand. Conversely at night, the ceiling temperature under the PV arrays was warmer, especially for the array mounted flat onto the roof. A one dimensional conductive heat flux model was used to calculate the temperature profile through the roof. The heat flux into the bottom layer was used as an estimate of the heat flux into the building. The mean daytime heat flux (1200-2000 PST) under the exposed roof in the model was 14.0 Watts per square meter larger than under the tilted PV array. The maximum downward heat flux was 18.7 Watts per square meters for the exposed roof and 7.0 Watts per square meters under the tilted PV array, a 63% reduction due to the PV array. This study is unique as the impact of tilted and flush PV arrays could be compared against a typical exposed roof at the same roof for a commercial uninhabited building with exposed ceiling and consisting only of the building envelope. Our results indicate a more comfortable indoor environment in PV covered buildings without HVAC both in hotter and cooler seasons.

Dominguez, A.↗

ISS Destiny Laboratory Smoke Detection Model

Smoke transport and detection were modeled numerically in the ISS Destiny module using the NIST, Fire Dynamics Simulator code. The airflows in Destiny were modeled using the existing flow conditions and the module geometry included obstructions that simulate the currently installed hardware on orbit. The smoke source was modeled as a 0.152 by 0.152 m region that emitted smoke particulate ranging from 1.46 to 8.47 mg/s. In the module domain, the smoke source was placed in the center of each Destiny rack location and the model was run to determine the time required for the two smoke detectors to alarm. Overall the detection times were dominated by the circumferential flow, the axial flow from the intermodule ventilation and the smoke source strength.

Brooker, John E.↗

Italian prototype building models for urban scale building performance simulation

Urban building energy modeling (UBEM) seeks to evaluate strategies to optimize building energy use at urban scale to support a city's building energy goals. Prototype building models are usually developed to represent typical urban building characteristics of a specific use type, construction year, and climate zone, as detailed characteristics of individual buildings at urban scale are difficult to obtain. This study investigated the Italian building stock, developing 46 building prototypes, based on construction year, for residential and office buildings. The study included 16 single-family buildings, 16 multi-family buildings, and 14 office buildings. Building envelope properties and heating, ventilation, and air conditioning system characteristics were defined according to existing building energy codes and standards for climatic zone E, which covers about half the Italian municipalities. Novel contributions of this study include (1) detailed specifications of prototype building energy models for Italian residential and office buildings that can be adopted by UBEM tools, and (2) a dataset in GeoJSON format of Italian urban buildings compiled from diverse data sources and national standards. Finally, the developed prototype building specifications, the building dataset, and the workflow can be applied to create other building prototypes and to support Italian national building energy efficiency and environmental goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using Residential and Office Building Archetypes for Energy Efficiency Building Solutions in an Urban Scale: A China Case Study

Building energy consumption accounts for 36% of the overall energy end use worldwide and is growing rapidly as developing countries continue to urbanize. Understanding the energy use at urban scale will lay the foundation for identification of energy efficiency opportunities to be deployed at speed. China has almost half of global new constructions and plays an important role in building suitability. However, an open source national building energy consumption database is not available in China. To provide data support for building energy consumptions, this paper used a simulation method to develop an urban building energy consumption database for a pilot city in Wuhan, China. First, residential, small, and large office building archetype energy models were created in EnergyPlus to represent typical building energy consumption in Wuhan. The baseline reference model simulation results were further validated using survey data from the literature. Second, stochastic simulations were conducted to consider different design parameters and occupants’ energy usage intensity scenarios, such as thermal properties of the building envelope, lighting power density, equipment power density, HVAC (heating, ventilation and air conditioning) schedule, etc. A building energy consumption database was generated for typical building archetypes. Third, data-driven regression analysis was conducted to support quick building energy consumption prediction using key high- level building information inputs. Finally, a web-based urban energy platform and an interface were developed to support further third-party application development. The research is expected to provide fast energy efficiency building design solutions for urban planning, new constructions as well as building retrofits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

IBPSA Project 2 BOPTEST: An update on the test cases available in the framework for testing advanced control strategies in buildings

Project 2 develops software infrastructure, test cases, and extensions for the Building Optimization Testing Framework (BOPTEST) to address the expanding needs of building and urban energy system controls through open international collaboration. This paper provides an overview of the new test cases available as of BOPTEST version 0.7.1. Each test case is developed using open-source Modelica libraries and Spawn of EnergyPlus, enabling the creation of high-fidelity building models that incorporate envelope dynamics, Heating Ventilation and Air Conditioning (HVAC) systems, and explicit control representations. Currently, eight test cases are available, with five additional cases under development. These test cases cover a wide range of climates, building types, and HVAC systems. This paper compiles and summarizes test case descriptions, cites original manuscripts that developed them for a more detailed description, and reports baseline control performance metrics. Furthermore, two example applications are presented: one illustrating different levels of control, from supervisory to low-level, and another demonstrating how Model Predictive Control (MPC) solutions must be adapted from continuous to integer to control some building actuators.

Zanetti, Ettore↗

Scenario Generation for Built Environment Decision Support under Uncertainty: Case Studies of Airflow Modeling and Climate-Resilient Infrastructure System Design

When confronted with unforeseen challenges, practicing informed decision making is crucial for enhancing resilience in the built environment. While scan-to-building information modeling (BIM) is a well-established approach for creating detailed digital representations of physical assets, its application in assessing and improving infrastructure resilience remains underexplored. This study addresses this gap by proposing a novel application of scan-to-BIM, namely, scan-to-BIM-to-digital twin (S-BIM-DT) workflow. By integrating reality capture and digital twin technologies, this workflow creates continuously updated and accurate digital representations of physical assets, enabling the generation of various scenarios. Unlike traditional methods, the S BIM-DT workflow facilitates continuous model refinement, supporting informed resilience strategies. By combining these technologies into a cohesive process, the workflow facilitates decision making under uncertainty, enabling stakeholders to evaluate and respond to various scenarios effectively. We demonstrate the implementation of the S-BIM-DT workflow through two use cases that highlight its capability to enhance resilience at different scales. The first use case involves the Combined Transportation, Emergency, and Communications Center (CTECC) in Austin, Texas. BIM-enriched computational fluid dynamics (CFD) modeling simulates airflow and develops alternative scenarios for optimizing the heating, ventilation, and air conditioning (HVAC) systems. This approach enhances resilience against airborne health threats in a postCOVID context. The second use case focuses on designated areas within Beaumont, Texas, as part of the Southeast Texas Urban Integrated Field Laboratory (SETx-UIFL) research. By developing inundation maps to assess extreme weather events, this modeling aids in preparedness efforts and informs the development of climate-resilient infrastructure in vulnerable neighborhoods. Results indicate that the S-BIM-DT workflow effectively generates scenarios that enhance resilience in the built environment by facilitating informed decision making. Furthermore, this study serves as a bridge between advanced scan-to-BIM methodologies and the practical strategies needed to improve built infrastructure resilience.

Built environment↗

UrbanScaping: Community Spatial Data Visualization & Analytics

Evaluating the electrification potential of buildings through retrofitting is crucial for reducing carbon emissions and the carbon footprint of built environments. This study leverages the Automatic Building Energy Modeling (AutoBEM) software, integrating the Model America database to create an urban context-based spatial analysis platform for community engagement and development. We selected Camp Hill Borough, PA, as a case study to analyze building-specific energy performance and evaluate the electrification potential of each building by switching to different Heating, Ventilation, and Air Conditioning (HVAC) systems and measurement components. The simulation results generated by the workflow provide retrofitting suggestions to help mitigate the carbon footprint as well as energy saving statistics of buildings. Additionally, the developed web-based interface serves as a community engagement platform, allowing residents to provide feedback and further develop interactive communication protocols. The outcomes of this project offer a baseline for community electrification planning and contribute to the design of low-carbon communities.

Chowdhury, Shovan [ORNL]↗

Cyclic Background Noise Variations on Infrasound Microbarometers From Micrometeorology and Human Activity

Infrasound microbarometers deployed on the Earth's surface capture pressure fluctuations and acoustic signatures, revealing trends in surface wind speed and cycles in ambient sound. Previous studies investigated wind noise trends at quarter day resolution and urban acoustic background variations on hourly to weekly scales. Cyclic variations at sub-hourly resolution over local distances remain unaddressed. We show that topography-driven micrometeorology impacts diurnal background noise levels below 10 Hz. Anthropogenic noise occurs over daily and weekly cycles, with inputs from traffic, ventilation systems, and power lines. These noise patterns vary at stations spaced less than a kilometer apart. We observe these phenomena by using a circular spectrogram to visualize frequency trends over a periodic temporal scale. This study demonstrates that infrasound microbarometer deployments can highlight localized wind patterns and time scales of human activity. The results suggest that future microbarometer deployments may benefit from site noise surveys before selecting final sensor locations.

Malach, Amrit Kaur [Sandia National Lab. (SNL-CA),↗

Progress in Fire Detection and Suppression Technology for Future Space Missions

Fire intervention technology (detection and suppression) is a critical part of the strategy of spacecraft fire safety. This paper reviews the status, trends, and issues in fire intervention, particularly the technology applied to the protection of the International Space Station and future missions beyond Earth orbit. An important contribution to improvements in spacecraft fire safety is the understanding of the behavior of fires in the non-convective (microgravity) environment of Earth-orbiting and planetary-transit spacecraft. A key finding is the strong influence of ventilation flow on flame characteristics, flammability limits and flame suppression in microgravity. Knowledge of these flow effects will aid the development of effective processes for fire response and technology for fire suppression.

Friedman, Robert↗

Prioritizing urban heat adaptation infrastructure based on multiple outcomes: Comfort, health, and energy

Globally, cities face increasing extreme heat, impacting comfort, health, and energy consumption. Infrastructure-based heat adaptation strategies can improve these outcomes, but each strategy has a unique mix of benefits and drawbacks. Here, we apply an urbanized meteorological model (WRF) with the newly integrated multilayer BEP-Tree street tree model to dynamically downscale Earth System Model projections and a 3-D microclimate model (TUF-Pedestrian) to simulate the street-scale radiation environment impacting pedestrians. We evaluate the performance of five heat adaptation strategies (street trees, cool roofs, green roofs, rooftop photovoltaics (PV), and reflective pavements) during extreme heat events in three cities with contrasting background climates (Toronto, Phoenix, and Miami), under contemporary and end-of-century projected climates, based on three metrics: outdoor heat stress, air conditioning (AC) energy use, and ventilation of vehicular air pollution. No single adaptation strategy improves all three outcomes. While street trees inhibit ventilation, they reduce outdoor heat stress four times more effectively than the next best strategy via shade provision, fully offsetting heat stress increases under a high-emissions end-of-century climate scenario in all cities studied. Cool roofs and green roofs moderately reduce heat stress and energy use. Alternatively, rooftop PV with energy storage can generate sufficient power for space cooling but have marginal effects on heat stress. Reflective pavements are the least effective across metrics. Where the ventilation of street-level emissions is of less concern, our results clearly support the combination of street trees and rooftop PV as a highly complementary and effective means of adaptive mitigation across different climates and neighborhood densities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Smart, Connected Manufactured Housing Solutions through High-Performance Design. Final CRADA report

This report focuses on HVAC, domestic hot water, and miscellaneous electric loads via voluntary opportunities that may arise from partnerships with utilities, as well as future US Environmental Protection Agency ENERGY STAR and DOE Zero Energy Ready Manufactured Home programs. Phase I of this project has begun the technical dialogue toward developing an implementation plan among DOE’s Oak Ridge National Laboratory, Clayton Manufactured Homes, and US Department of Housing and Urban Development Code manufactured housing stakeholders. These activities have focused on delivering high-performance design through integration of technology. Project tasks include the following: Identifying baseline energy analysis resources opportunities from a variety of DOE and utility stakeholders; Developing a smart home and business solution by leveraging existing utility programs working with Smart Homes Partners resources such as ACE IoT Solutions, Google Nest, and Ecobee; Developing improved smarter ventilation systems with industry ventilation partners such as the Madison Group; Developing improved building science QA/QC testing equipment with manufacturers such as The Energy Conservatory, and supporting other feasible concepts vetted under DOE’s Advanced Buildings Collaborative with Slipstream, reinventing HVAC in manufactured housing; and, Developing smart home short- and long-term viable technical solutions in coordination with Clayton Manufactured Homes in new and/or revitalized community scales for future Phase II prototype demonstrations, which may include design (and perhaps construction) of single-section homes targeting rental property developers and multi-section homes targeting low- to middle-income affordable housing community developers Given the ongoing US Department of Energy (DOE) rulemaking activities, baseline energy analysis assessments of envelope prescriptive and Uo (i.e., the overall thermal energy efficiency of the home in British thermal units per square foot of exterior heat loss/gain surfaces) measures were removed from the scope of Phase I of this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal electric-distribution-grid planning considering the demand-side flexibility of thermal building systems for a test case in Singapore

The planning of district-scale electric grids, i.e., distribution grids, has traditionally relied on finding the most cost-effective design such that they are able to supply the peak loads in a district. With the advent of electric demand side flexibility (DSF), there is the opportunity to reshape peak loads such that the investment cost of the electric grid decreases in exchange for a minor increase in the operation cost. This paper formulates an optimal planning approach for the electric grid at the district scale, which incorporates the DSF from thermal building systems, e.g., heating ventilation and air-conditioning (HVAC) systems. The problem is formulated as a mixed-integer linear program (MILP) and aims at minimizing the investment cost for the grid along with the operation cost of the flexible loads. This is subjected to the fixed electricity demand and thermal comfort constraints of building occupants. To this end, linear models for the thermal comfort in the buildings and the power flow in electric grid are considered. The approach is tested on a district planning test case based in Singapore, where the results show up to 30.9 % reductions in investment cost and up to 3.7 % reduction in total annualized cost. Urban planning authorities, developers and utility companies can all benefit from the presented approach to make optimized investment decisions. For building operators, the results point to the need of adopting their control systems for DSF.

Troitzsch, Sebastian↗