Search NASA⌕ Search

SEARCH · Search NASA

Results for “Using Insulation and Windows Together”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Performance of Windows in Walls With Continuous Insulation

Window openings in walls are a significant contributor to poor thermal performance because of thermal bridging through the framing members (e.g., studs, joists, plates, bracing) and because windows lack the thermal properties of insulation. Window installation guidance for walls with continuous insulation (CI) is critical for continued market growth of this energy efficiency technology. This research project offers window manufacturers a starting point and a potential path toward developing installation instructions for windows over CI. The objectives of the research include evaluating the common method for installing windows in walls with CI, as well as establishing acceptance criteria for evaluating the performance of windows installed in walls with and without CI. The research measures: 1. The performance characteristics (e.g., water management, structural integrity) of windows in walls without CI. 2. The performance of different thicknesses and types of CI used in walls. 3. The performance of different types of window assemblies (e.g., double-hung windows, mulled double-hung windows, mulled casement windows, and slider windows) installed over CI. 4. The performance of window flange types (e.g., rigid mounting and less robust flanges) installed over CI. 5. Installing windows over CI using baseline installation instructions versus window manufacturer installation instructions. The project’s sequential testing protocol consists of the following: • A water penetration resistance testing adapted from two ASTM standards: E331 (uniform static air pressure in four steps) and E547 (cyclic static air pressure) • A temperature cycling adapted from ASTM E2264 Method B (convective hot air) • A service condition wind loading test adapted from ASTM E330 • A six-month vertical displacement observation phase prior to the structural performance testing • A final water penetration resistance test after vertical displacement observation • A structural performance test adapted from ASTM E330. Key research findings include: • The criterion for passing a water penetration resistance test is that there is no water overflowing at the interior face of the studs. If there is any bubbling or slight pooling of water at the sill, then it must recede after the pressure is removed. Excessive leakage and/or water leaking to the interior face of the framing around the window constitutes a failure. • All single double-hung windows installed directly to lumber or over oriented strand board passed all test protocols. • For most wall specimens, the test results showed that the use of foam sheathing did not affect the performance of the window for water leakage. • All wall specimens underwent temperature cycling. The results indicated that temperature cycling had little to no effect on windows installed over foam sheathing. • For wall specimens that underwent six-month vertical displacement monitoring, the results showed that windows installed over foam sheathing do not sag over time. • The single-hung and double-hung windows installed using window manufacturer installation instructions passed the structural performance test, compared to failures observed in windows that were installed using generic installation instructions. The generic and manufacturer installation methods differed on the following construction details: type of fasteners, fastening patterns on the flanges, and window shimming details. • Additional testing is required to determine methods to improve structural pressure performance of slider windows. Potential solutions that would require additional testing may include fastener spacing, different types of fasteners, masonry window clips, construction adhesive, foam sealant, stronger window flange material, and/or straps.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Two-Band, Low-Loss Microwave Window

A window for a high-sensitivity microwave receiving system allows microwave radiation to pass through to a cryogenically cooled microwave feed system in a vacuum chamber, while keeping ambient air out of the chamber and helping to keep the interior of the chamber cold. The microwave feed system comprises a feed horn and a low-noise amplifier, both of which are required to be cooled to a temperature of 15 K during operation. The window is designed to exhibit very little microwave attenuation in two frequency bands: 8 to 9 GHz and 30 to 40 GHz. The window is 15 cm in diameter. It includes three layers (see figure): 1) The outer layer is made of a poly(tetrafluoroethylene) film 0.025 mm thick. This layer serves primarily to reflect and absorb solar ultraviolet radiation to prolong the life of the underlying main window layer, which is made of a polyimide that becomes weakened when exposed to ultraviolet. The poly(tetrafluoroethylene) layer also protects the main window layer against abrasion. Moreover, the inherent hydrophobicity of poly(tetrafluoroethylene) helps to prevent the highly undesirable accumulation of water on the outer surface. 2) The polyimide main window layer is 0.08 mm thick. This layer provides the vacuum seal for the window. 3) A 20-mm-thick layer of ethylene/ propylene copolymer foam underlies the main polyimide window layer. This foam layer acts partly as a thermal insulator: it limits radiational heating of the microwave feed horn and, concomitantly, limits radiational cooling of the window. This layer has high compressive strength and provides some mechanical support for the main window layer, reducing the strength required of the main window layer. The ethylene/propylene copolymer foam layer is attached to an aluminum window ring by means of epoxy. The outer poly(tetrafluoroethylene) film and the main polyimide window layer are sandwiched together and pressed against the window ring by use of a bolted clamp ring. The window has been found to introduce a microwave loss of only about 0.4 percent. The contribution of the window to the noise temperature of the microwave feed system has been found to be less than 1 K at 32 GHz and 0.2 K at 8.4 GHz.

Britcliffe, Michael↗

Photonic ring resonator notch filters for astronomical OH line suppression

Photonic ring resonator arrays used as notch filters are a promising novel solution to improve the signal-to-noise ratio of ground-based astronomical observations by suppressing OH emission lines in the near-infrared (NIR) wavelength range (0.9-2.5 μm). We aim to fabricate a series of ring resonators connected by a waveguide, each with its resonance wavelength and full-width-half-maximum (FWHM) matched with one of the OH emission lines. The fundamental structure of ring resonator-based notch filters is a ring resonator evanescently coupled to a waveguide. Due to the optical loss of the ring resonator, the transmission of light through the waveguide will be suppressed at the resonance wavelength of the ring resonator. The degree of suppression can be controlled by varying the coupling strength between the waveguide and the ring resonator, while the resonance wavelength can be controlled by the geometry and size of the ring. However, since a single ring resonator has multiple modes each with a different wavelength separated by its free spectral range (FSR), the additional suppression at other wavelengths may undermine the signal. Therefore, the ideal FSR off the ring resonators needs to be larger than the measurement window. For this application, we aim the FSR to be 1 larger than 30 nm . Our initial measurement results revealed two major challenges for this application. First, the FSR of the ring resonators is limited by the bending loss of ring resonators. In a standard 220 nm silicon-on-insulator material platform, the FSR of ring resonators cannot exceed 30 nm; Second, due to the wafer thickness variation and fabrication inaccuracy, the achievable accuracy in the resonance wavelength of a fabricated single ring resonator is only ~1.5 nm. In this work, we report our novel solutions to the above two challenges. For the first one, we have developed a novel structure based on the Vernier effect to greatly raise the FSR of ring resonators. Serially coupled Vernier ring structures is a typical approach to increase the FSR without encountering bending loss, but it requires restrictive matching of the coupling and optical loss of the rings and any imperfect matching can result in even noisier signals. On the contrary, our structure, as shown in shown in Fig. 1, does not require the restrictive matching. The signals of two output ports in our structure marked in Fig. 1 will be added together to form the final output signal, and Fig. 2 shows the finite-difference time-domain (FDTD) simulation results of the final output signal. As can be seen, the FSR of the entire structure is well-beyond 60 nm with little noise at other wavelengths. For the second one, we have developed an easy-to-implement method to permanently tune the resonance wavelengths of ring resonators within 0.1 nm accuracy. The tuning mechanism is based on the property of hydrogen silsesquioxane (HSQ) resist. As a negative tone electron beam resist, HSQ upon exposure will cross-link and eventually form SiO2. The refractive 2 index of HSQ resist and formed SiO2 are slightly different , enabling the tuning. By having a thin layer of HSQ resist on top of ring resonator structures followed by SiO2 cladding, the resonance wavelengths of ring resonators can be post-tuned Advances in Optical Astronomical Instrumentation 2019, edited by Simon Ellis, Céline d'Orgeville, Downloaded From: https://www.spiedigitallibrary.org/conference-proceedings-of-spie on 23 Sep 2020 Terms of Use: https://www.spiedigitallibrary.org/terms-of-use through electron beam exposure. We have found that, within 5 nm tuning range, the resonance wavelength shift and dosage applied obeys a linear relationship. So a simple calibration beforehand can result in resonance wavelength tuning within 0.1 nm accuracy. The transmission spectra of a 3-ring device before and after tuning is shown in Fig. 3.

Astronomical optics↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗