Search NASA⌕ Search

SEARCH · Search NASA

Results for “Utilities Transfer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Multi-Gravity Docking and Utilities Transfer System for a Common Habitat Architecture

The Common Habitat architecture, a study architecture based on a large habitat derived from the SLS Core Stage Liquid Oxygen tank and designed to operate in microgravity, lunar surface, and Mars surface environments, requires a pressurized docking and berthing system that also works in all three domains. Prior flown docking systems have only been designed for microgravity, but a prototype suit port-derived docking system was developed under the Constellation program for the lunar surface. This system employed an active-active mating adapter approach consisting of a simplistic passive docking system on all spacecraft and a pressurized mating adapter with active systems on each end to form the docking connection. Derived from this approach, the Common Habitat architecture will use a multi-gravity active-active mating adapter (MGAAMA) to perform this function on the Moon, Mars, and in microgravity, connecting the various pressurized elements needed for surface base camps or deep space habitation. Design aspects and open trades of the MGAAMA system will be described. In addition to forming a structural connection and enabling the transfer of crew and equipment, the MGAAMA must also transfer utilities in the form of gases, fluids, power, and data. The MGAAMA is also designed with a degree of articulation in order to accommodate significant angular misalignment. Due to the environmental conditions the MGAAMA will experience, dust and thermal protection systems are discussed. Because the MGAAMA involves docking to spacecraft with different docking systems of different sizes, the MGAAMA is a family of docking systems with interfaces compatible with current and legacy spacecraft docking systems.

Docking↗

Electrical characterization of a Space Station Freedom alpha utility transfer assembly

Electrical testing of a utility transfer assembly (UTA) developmental unit performed from January 22 through February 25, 1992 at the NASA Lewis Research Center using the power management and distribution dc test bed. The dc resistance and steady state temperatures recorded are evidence of the UTA's high electrical transfer efficiency. The impedance test results suggest the total inductance of a UTA crossing pair is substantially higher than originally specified in the Space Station Electrical Power System Architectural Control Document.

Yenni, Edward J.↗

Electrical characterization of a Space Station Freedom alpha utility transfer assembly

Electrical power, command signals and data are transferred across the Space Station Freedom solar alpha rotary joint by roll rings, which are incorporated within the Utility Transfer Assembly (UTA) designed and manufactured by Honeywell Space Systems Operations. A developmental Model of the UTA was tested at the NASA Lewis Research Center using the Power Management and Distribution DC test bed. The objectives of these tests were to obtain data for calibrating system models and to support final design of qualification and flight units. This testing marked the first time the UTA was operated at high power levels and exposed to electrical conditions similar to that which it will encounter on the actual Space Station. Satisfactory UTA system performance was demonstrated within the scope of this testing.

Yenni, Edward J.↗

(abstract) Precision Time and Frequency Transfer Utilizing SONET OC-3

An innovative method of distributing precise time and reference frequency to users located several kilometers from a frequency standard and master clock has been developed by the Timing Solutions Corporation of Boulder, CO. The Optical Two-Way Time Transfer System (OTWTTS) utilizes a commercial SONET OC-3 facility interface to physically connect a master unit to multiple slave units at remote locations. Optical fiber is a viable alternative to standard copper cable and microwave transmission. This paper discusses measurements of frequency and timing stability over the OTWTTS.

optical fiber precision time standards frequency r↗

Advanced metal hydride heat transfer system utilizing an electrochemical hydrogen compressor

An electrochemical heat transfer device utilizes an electrochemical hydrogen compressor to pump hydrogen into and out of a reservoir having a metal hydride forming alloy therein. The absorption of hydrogen by the metal hydride forming alloy is exothermic, produces heat, and the desorption of the hydrogen from the metal hydride forming alloy is endothermic and draws heat in. An electrochemical hydrogen compressor may be configured between to reservoirs and pump hydrogen back and forth to form a heat transfer device. A heat exchange device may be coupled with the reservoir or may comprise the outer surface of the reservoir to transfer heat to an object or to the surroundings. A closed loop may be configured having two reservoirs and one or two electrochemical hydrogen compressors to pump the hydrogen in a loop around the system.

Bahar, Bamdad↗

Advanced metal hydride heat transfer system utilizing an electrochemical hydrogen compressor

An electrochemical heat transfer device utilizes an electrochemical hydrogen compressor to pump hydrogen into and out of a reservoir having a metal hydride forming alloy therein. The absorption of hydrogen by the metal hydride forming alloy is exothermic, produces heat, and the desorption of the hydrogen from the metal hydride forming alloy is endothermic and draws heat in. An electrochemical hydrogen compressor may be configured between to reservoirs and pump hydrogen back and forth to form a heat transfer device. A heat exchange device may be coupled with the reservoir or may comprise the outer surface of the reservoir to transfer heat to an object or to the surroundings. A closed loop may be configured having two reservoirs and one or two electrochemical hydrogen compressors to pump the hydrogen in a loop around the system.

Bahar, Bamdad↗

Data for The utility of transfer learning to improve the performance of deep learning in axon segmentation

The utility of transfer learning to improve the performance of deep learning in axon segmentation Data Data: All the input and labeled volumes tf-logs: Tensorflow logs, view with command "tensorboard --logdir [name of folder]" Model Weights: model_weights: the argument list under variable combo indicate 1) no oversampling, 2) no rotation, 3) no learn scheduler, and 4) flipping on all three dimensions, and the additional values indicate 5) elastic deformation percentage, 6) rotate deformation percentage, 7) layer setting , 8) learning rate, and 9) training/validation/test data division suffix (leave '' if not using suffix). Results: Output from inference segment_total_results_validation_final: All validation results and calculations segment_total_results: All test results and calculations Authors The modified code was created for a paper by: Marjolein Oostrom, Michael A. Muniak, Rogene Eichler West, Sarah Akers, Paritosh Pande, Moses Obiri, Wei Wang, Kasey Bowyer, Zhuhao Wu, Lisa Bramer, Tianyi Mao, Bobbie Jo Webb-Robertson The work is adapted from Github TrailMap, which was created by Albert Pun and Drew Friedmann Acknowledgments MO, RMEW, SA, MO, LB, BJWR were supported by the Laboratory Directed Research and Development at Pacific Northwest National Laboratory (PNNL), a Department of Energy facility operated by Battelle under contract DE-AC05-76RLO01830. WW, KB, and ZW were supported in part by a NIH/BRAIN Initiative Grant RF1MH128969. MAM and TM were supported by two NIH/BRAIN Initiative Grants R01NS104944, RF1MH120119 and NIH R01NS081071. This research is affiliated with the Pacific northwest bioMedical Innovation Co-laboratory (PMedIC) collaboration between OHSU and PNNL.

Oostrom, Marjolein T↗

Advanced metal hydride heat transfer system utilizing an electrochemical hydrogen compressor

An electrochemical heat transfer device for a hot water tank utilizes an electrochemical hydrogen compressor to pump hydrogen into and out of a tank having a metal hydride forming alloy therein. The absorption of hydrogen by the metal hydride forming alloy is exothermic, produces heat, and the desorption of the hydrogen from the metal hydride forming alloy is endothermic and draws heat in. An electrochemical hydrogen compressor may be configured between to tanks and pump hydrogen back and forth to form a heat transfer device, such as a hot water heater. A heat transfer device may be coupled with the tank or may comprise the outer surface of the tank to transfer heat to an object or to the surroundings. A closed loop may be configured having two tanks and one or two electrochemical hydrogen compressors to pump the hydrogen in a loop around the system.

Bahar, Bamdad↗

Enhanced carbon-transfer and -utilization efficiencies achieved using membrane carbonation with gas sources having a range of CO 2 concentrations

The economic viability of microalgal biofuels relies on increasing productivity in a cost-effective manner. As microalgal biomass contains > 50% carbon, a high rate of CO 2 delivery is required for high productivity, and inefficient CO 2 delivery amplifies operating costs. Membrane carbonation using non-porous hollow fiber membranes can ideally deliver CO 2 without bubble formation and high carbon transfer efficiency. Because CO 2 streams from industrial resources are not 100% CO 2 , the buildup of inert gasses can significantly lower the CO 2 delivery rate when the distal end of the membrane is closed. To overcome the buildup of inert gases, we managed the distal end of the membranes with three different approaches: fully open end, restricted bleed valve, and restricted bleed valve with pH-actuated venting. For all approaches, CO 2 was delivered to membranes ondemand based on a pH set point. Evaluating a wide range of CO 2 concentrations (10% to 100%), we found that all approaches eliminated the buildup of inert gases, could maintain target pH values and gave the same biomass productivities and carbon distributions. However, carbon transfer efficiency depended on the operation of the distal end. Fully open-end operation gave a poor carbon transfer efficiency because of excessive loss of CO 2 from the distal end. However, restricting the exit flow rate to ≤4 cm 3 /min mitigated the problems of excessive CO 2 loss, but without incurring a large loss of CO 2 -delivery flux. For the continuous cultivation, combining a restricted bleed valve with pH-actuated venting improved the carbon-transfer efficiency and -utilization efficiencies up to 85% and 67%, respectively, with a sufficient CO 2 delivery flux.

42 ENGINEERING↗

Fine-tuning TrailMap: The utility of transfer learning to improve the performance of deep learning in axon segmentation of light-sheet microscopy images

Light-sheet microscopy has made possible the 3D imaging of both fixed and live biological tissue, with samples as large as the entire mouse brain. However, segmentation and quantification of that data remains a time-consuming manual undertaking. Machine learning methods promise the possibility of automating this process. This study seeks to advance the performance of prior models through optimizing transfer learning. We fine-tuned the existing TrailMap model using expert-labeled data from noradrenergic axonal structures in the mouse brain. By changing the cross-entropy weights and using augmentation, we demonstrate a generally improved adjusted F1-score over using the originally trained TrailMap model within our test datasets.

97 MATHEMATICS AND COMPUTING↗

Data-driven Mapping of the Mouse Connectome: The utility of transfer learning to improve the performance of deep learning models performing axon segmentation on light-sheet microscopy images

Light sheet microscopy has made possible the high temporal and spatial 3D imaging of both fixed and live biological tissue, with samples as large as the entire mouse brain. However, segmentation and quantification of that data remains a time-consuming manual process. Machine learning methods promise the possibility of automating this process. This study seeks to advance the performance of prior models through the application of refinements such as transfer learning.

59 BASIC BIOLOGICAL SCIENCES↗

Results of phase change paint heat transfer tests utilizing 0.040 scale 50% forebody models (No. 82-0) of the Rockwell International space shuttle orbiter in AEDC VKF hypersonic tunnel B (test OH54A)

Results of aerodynamic heating tests conducted in October 1974 on a space shuttle orbiter model using the phase change paint technique are presented. The model was a 0.040 scale representation of the forward 50 percent of the orbiter. Surface roughness effects on boundary layer transition were investigated. Roughness was simulated by using steel balls varying in diameter from 0 (no balls) to 0.039 inch with 0.040 inch wide by 0.080 inch deep gaps. A nominal Mach number of 8 was tested with Reynolds number varying from 0.75 through 3.5 million per foot. Angle of attack was varied from 20 deg to 40 deg.

Dye, W. H.↗

Results of phase change paint heat transfer test utilizing 0.040-scale 50% forebody models (no. 82-0) of the Rockwell International Space Shuttle Orbiter in AEDC VKF hypersonic tunnel B (test OH54B)

Aerodynamic heating phase change paint tests for the space shuttle orbiter are reported. The model was a 0.040 scale representation of the forward 50% of the orbiter. Surface roughness effects on boundary layer transition were investigated. The roughness was simulated by steel balls 0.020 and 0.025 inch in diameter and a 0.25 in. diameter hole simulating the forward ET attach socket. A nominal Mach number of was tested with unit Reynolds number varying from 0.75 x 1 million ft through 3.5x 1 million ft. Angle of attack was varied from 20 degrees to 40 degrees.

Dye, W. H.↗