Logical Approach to Tritium Vacuum Pump Selection

Introduction Vacuum pumps are essential to the operation of tritium purification and recovery processes. However, not all vacuum pumps sold meet the requirements for tritium service. Manufacturers routinely do not fully appreciate the hazards associated with tritium, or the complex materials interactions. Therefore, a decision tree was established detailing which pump types, and certain manufacturers, are either fully compatible, limited use, or to avoid at all costs to establish a more structured and uniform approach to tritium vacuum pumps.

ANGELETTE, LUCAS

Deployable Element Ultra High Vacuum Pump

Most existing vacuum pump technologies remain stationary, limiting their effectiveness in a molecular environment. In low vacuum environments, molecules move in a particular path towards the source of pumping. As the mean-free-path increases, the system’s ability to capture molecules diminishes and pump-down time increases. To address this, the team explored various designs that would deploy the pump surface closer to the molecules. After several iterations, a “windmill” shape for the final design. This design employs titanium sublimation technology in a deployable configuration, effectively reducing the distance between residual molecules and the pump surfaces, thereby minimizing randomness and improving particle capture.

Etayem, Brandon [Northern Illinois U.]

Logical approach to tritium vacuum pump selection for fusion applications

Vacuum pumps have been used for tritium processing since the 1940s following the isolation of pure tritium. The largest problem facing tritium vacuum pumps is the tritium radioactive decay. The beta particles, recoil energy, and subsequent radical formations are detrimental to most carbon-based materials. Carbon materials, such as plastics, elastomers, carbon fiber, activated carbon, etc., react with tritium to form methane and in the process strip material from the carbonbased material. Other reactions can be self-catalyzing, as is the case with nitrogen and tritium forming tritiated ammonia at room temperature and pressure. Tritium also readily isotopically exchanges with surface -OH groups, increasing the amount of protium in the gas stream while creating a tritium holdup on the surface. Metals are the preferred material when working with tritium, but tritium will permeate into and through almost all metals at some point. The entrapped tritium can decay inside the metal, creating local helium distortions that can impact the structural properties above and beyond the hydrogen embrittlement issue tritium can cause.

Angelette, Lucas M. [Savannah River National Labor

Deployable Element Ultra-High Vacuum Pump

Advancing Ultra High Vacuum (UHV) Pumping Technology: The deployable UHV pump team has designed a theoretical model to boost efficiency in high vacuum environments. Traditional systems face challenges with random molecular motion. The innovative windmill design, using titanium sublimation technology, reduces randomness by deploying a gettering surface that actively captures particles. This marks a notable advancement in UHV pumping technology.

43 PARTICLE ACCELERATORS

First operation and validation of simulations for the divertor cryo-vacuum pump in Wendelstein 7-X

Ten cryo-vacuum pumps (CVPs) were installed in the subdivertor region of each island divertor in the stellarator Wendelstein 7-X (W7-X) and operated for the first time during the recently completed plasma campaign OP2.1. A pumping speed of 70 ± 1 $\frac{m^3}{s}$ was measured during dedicated tests with known hydrogen gas injection. Based on a conductance model, the estimated pumping speed ranges from 86-93 $\frac{m^3}{s}$ for different sticking coefficients between 0.6 and 0.8. After completion of the initial tests the CVPs were operated successfully throughout the campaign, with regeneration performed once a week. Neutral gas pressures in the subdivertor in the range of 10 −4 mbar are well within the molecular flow regime and limit the particle exhaust capabilities of the CVPs. Simulations of the neutral gas pressure in the three-dimensional complex geometry of the subdivertor were performed using the DIVGAS code based on the direct simulation Monte Carlo method and a model implemented in the steady-state thermal package in ANSYS, which are in agreement with the measured values during plasma operation.

Cryo-vacuum pumping

High Insulating Vacuum Pump Cart Analysis

To maintain superconductive and cryogenic temperature, it is necessary to utilize high vacuum to eliminate convective heat transfer. To reach the desirable pressure of 10^-6 Torr at a reasonable time, the vacuum pumps and vessel geometry are evaluated for compatibility. Based on the analysis, a list of dry scroll pumps and turbomolecular pumps are recommended.

Chicas, Kelly [Illinois U., Urbana]

Evaluation of Vacuum Pumps for Low-Tritium Applications

As fusion and other applications that require tritium processing capabilities become more prominent worldwide, it begins to strain the supply of tritium compatible pumps. In order to help alleviate the supply chain bottleneck, alternatives need to be identified that can help reduce the required number of tritium compatible pumps to strictly the primary process loop where tritium concentrations are high. This research is aimed at identifying vacuum pumps that can be used in low tritium environments (e.g., glovebox stripper systems, adsorbent regeneration, flush gas/inert line evacuation, etc.)

Angelette, Lucas M. [Savannah River National Labor

Deployable Element Ultra-High Vacuum Pump

This poster briefly highlights the challenge the senior design team was tasked with, and the events that led up to the ultimate solution. Described within the poster are problem statements, the design tasks that were formed based on the problem statement, the design processes and deliverables of the project, as well as the project outcome/impact.

Etayem, Brandon [Northern Illinois U.]

Numerical analysis of gas exhaust in Wendelstein 7-X using the direct simulation Monte Carlo method

The present work is focused on a 3D numerical assessment of the Wendelstein 7-X (W7-X) particle exhaust. For all the numerical simulations the direct simulation Monte Carlo solver of the DIVGAS workflow, has been employed. The complex 3D geometry of the sub-divertor region includes the pumping gap panel, supporting structures, cooling pipes as well as the cryo-vacuum pump. All the considered flow simulations correspond to the Standard magnetic configuration of W7-X. The main conclusions, which can be extracted from the present numerical analysis could be summarized as follows; The coupling between EMC3-EIRENE and DIVGAS, which considers the fact that the incoming neutral particle flux at the sub-divertor is based on realistic plasma background, has been demonstrated. Three plasma scenarios have been considered, for which is clearly seen that by increasing the heating power, the neutral pressure as well as the resulting pumping efficiency is increased. The obtained numerical results of the neutral pressure in the sub-divertor lie within a more general scan matrix, which assumes a wider range of incoming particle flux, namely 10 19 –10 24 (s −1 ). It has been observed that, the sub-divertor neutral pressure is proportional to the incoming neutral particle flux, with the effective pumping speed to be a constant of proportionality. The influence of switching off the cryo-vacuum pump on the sub-divertor pressure is rather modest and a weak increase of the neutral pressure in the sub-divertor is expected. Correlations of the sub-divertor pressure with the total incoming particle flux as well as the individual pumped flux at each of the AEH and AEP sections have been deduced. Moreover, it has been demonstrated that the influence of the incoming neutral particle flux on the albedo coefficient at the AEH and AEP pumping gaps is rather weak. All the above numerical findings will actively support the optimization of the W7-X particle exhaust, in view of future experimental campaigns.

DSMC method

Exergy Analysis of a Convective Heat Pump Dryer Integrated with a Membrane Energy Recovery Ventilator

To increase energy efficiency, heat pump dryers and membrane dryers have been proposed to replace conventional fossil fuel dryers. Both conventional and heat pump dryers require substantial energy for condensing and reheating, while “active” membrane systems require vacuum pumps that are insufficiently developed. Lower temperature dehumidification systems make efficient use of membrane energy recovery ventilators (MERVs) that do not need vacuum pumps, but their high heat losses and lack of vapor selectivity have prevented their use in industrial drying. In this work, we propose an insulating membrane energy recovery ventilator for moisture removal from drying exhaust air, thereby reducing sensible heat loss from the dehumidification process and reheating energy. The second law analysis of the proposed system is carried out and compared with a baseline convective heat pump dryer. Irreversibilities in each component under different ambient temperatures (5–35 °C) and relative humidity (5–95%) are identified. At an ambient temperature of 35 °C, the proposed system substantially reduces sensible heat loss (47–60%) in the dehumidification process, resulting in a large reduction in condenser load (45–50%) compared to the baseline system. The evaporator in the proposed system accounts for up to 59% less irreversibility than the baseline system. A maximum of 24.5% reduction in overall exergy input is also observed. The highest exergy efficiency of 10.2% is obtained at an ambient condition of 35 °C and 5% relative humidity, which is more than twice the efficiency of the baseline system under the same operating condition.

Balaraman, Anand (ORCID:0000000218355788)

EM-Enhanced HyPOR Loop for Fast Fusion Cycles

Vacuum pumps are the heart of a fusion energy facility – fusion power cannot be generated without them. Nevertheless, the vacuum technology needed to operate a viable fuel cycle for a compact fusion power plant does not exist. Commercial vacuum technology offers the best solution to this challenge, but a pump oil recycling and detritiation system is necessary. Conventional oil detritiation processes have only been developed to deal with legacy waste and are too slow and destructive to the oil. Further, post hoc detritiation strategies are intrinsically inefficient. Our approach is to rethink the challenge holistically by designing the pumping fluid and tritium extraction system in an integrated manner to achieve an innovative solution. By selecting an oil for the specific task of pumping tritium and then designing our catalytic system to selectively target the tritium-bearing functional groups, an effective detritiation system (hydrocarbon pump oil recycling, HyPOR, loop) for fusion power plants can be obtained. The project demonstrated a HyPOR loop process that can selectively remove heavier hydrogen isotopes from pump oil, reaching the target of 99.5 % removal, with an uptake of less than 0.01% of tritium throughput, while also purifying the oil of radiation-induced damage. The recycled oil retained its pumping characteristics over 7 recycles and gamma irradiation over 30 MGy. By meeting these targets, the project enable a reduction in pump operational costs from $\$$14.5M/year to $\$$103k/year (>140× reduction), reducing pump electric power consumption from 2.8 MW to 0.25 MW (>10× reduction), and reducing in-process tritium inventory from 2.03 kg to 0.48 kg (>4× reduction).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Continued Testing and Modeling of the AirSquared All-Metal Tritium Scroll Pump

The implementation of fusion energy requires the processing of the deuterium-tritium mixture used to fuel the reaction. Many gas processing operations require either a gas-motive force or a pressure gradient across a system; both are achieved using vacuum pumps. However, because of the material challenges of working with tritium, specialized pumps are required that use only metal on wetted surfaces. This prevents tritium retention and degradation of materials such as oils and polymers and reduces the generation of tritiated waste. Typical gas handling systems for tritium operations involve metal bellows pumps, all-metal scroll pumps, and metal turbomolecular pumps, depending on the pressure requirements. With the industry standard Normetex Type 15 m 3 /h (typically referred to as the Normetex 15) pump no longer available, the fusion market requires viable alternatives. In this study, we test an American-made pump, the AirSquared V16H034A-C01, and compare its performance to the Normetex. A performance model of the AirSquared pump is also produced, which can be applied to general process models to generate an accurate description of pressures and flows through various unit operations.

08 HYDROGEN

Transformational Sorbent System for Post-Combustion Carbon Capture (Final Report)

As part of this DOE Contract (Transformational Sorbent System for Post-Combustion Carbon Capture, DE-FE0031734),TDA Research Inc. developed a transformational sorbent system for post combustion CO 2 capture process that captures more than 95% of CO 2 emissions from a coal fired power plant, recovering CO 2 at 95% purity with a cost of CO 2 capture significantly lower than with amine-based system (~$30 per tonne (MT) of CO 2 captured). TDA’s transformational sorbent system uses a novel, highly stable, high-capacity metal organic framework (MOF) based CO 2 sorbent in a new vacuum/concentration swing adsorption (VCSA) process that allows us to use high efficiency vacuum pumps with a low auxiliary load. A pulverized coal fired power plant equipped with TDA’s transformational sorbent system for post combustion CO 2 capture is expected to efficiently produce electricity with a low Cost of Electricity (COE) and capture greater than 95% of the CO 2 from the power plant exhaust.

01 COAL, LIGNITE, AND PEAT

Operational Experience of the NML Cryogenic Plant at the FAST Test Facility

The NML cryogenic plant cools two individually cryostated superconducting radio frequency (SRF) capture cavities and one prototype ILC cryomodule with eight SRF cavities. This complex accelerates electrons at 150 MeV for the Integrable Optics Test Accelerator (IOTA) ring, located at the Fermilab Accelerator Science and Technology (FAST) facility. The cryogenic plant is composed of two nitrogen precooled Tevatron satellite refrigerators, two Mycom 2016C compressors, a cryogenic distribution system, a Frick purifier compressor, two charcoal bed adsorber purifiers, and a liquid ring vacuum pump with a roots booster. The SRF cavities are immersed in a 2.0 K liquid helium bath, shielded with a 5 K gaseous helium shield and a liquid nitrogen cooled thermal shield. Since 2019, this R&D accelerator complex has gone through four science runs with an average duration of 12 months. Operational experience for each run, availability metrics, performance data and common outages are presented in this paper.

Wallace, Timothy [Fermilab] (ORCID:000900051589302

Deployable UHV Pump

This project presents an external motorized actuation system for a deployable ultra-high vacuum (UHV) pump, enabling internal motion without compromising vacuum conditions. All active components remain external due to environmental and space constraints. A motor-driven mechanical feedthrough transfers motion into the pump, supported by a modular, adjustable mounting system that maintains alignment and integrates with existing hardware. CAD modeling and iterative design were used to refine geometry and ensure proper fit. The final design reliably transfers motion while maintaining alignment and structural integrity. Its adjustability improves installation and maintenance, demonstrating a practical solution for actuation in UHV systems.

Remington, Austin [Northern Illinois U.]

Development of advanced vacuum technologies for extending plasma pulse duration on EAST

Advanced vacuum technologies, including pumping, fueling and wall conditioning, have been successfully developed or upgraded to efficiently control the fuel and impurity particles to extend the plasma pulse duration in the experimental advanced superconducting tokamak (EAST). To improve the particle exhaust rate cryopumps with a 60% increase in pumping speed and ∼2 times increase in saturation capacity have been developed, and molecular pumps with a ∼30% increase in pumping speed have been upgraded. In order to monitor the molecular pump status while avoiding bearing faults and overload accidents, a fault detection system has been built which can offer an early warning to avoid more losses within the fusion device. A series of fueling technologies have been developed including gas injection system, supersonic molecular beam injector, pellet injector (PI), massive gas injector and shattered pellet injector, installed at the midplane and divertor positions at different ports to improve fueling uniformity and efficiency. Meanwhile, routine wall conditioning such as electric and hot N 2 baking, ion cyclotron wall conditioning and glow discharge cleaning have been successfully developed to remove the impurity particles from the inner component and materials. The low Z material wall coating and real-time powder injection during plasma discharge are also designed and applied to further improve particle control capability. Finally, by using these advanced vacuum related technologies, good vacuum (<2 × 10 −6 Pa) and wall conditions are realized, and the fuel and impurity particles can be effectively and stably controlled, which promotes the achievement of the record plasma of ∼1056 s pulse duration with the line-averaged electron density of 1.8 × 10 19 m −3 on EAST. They provide a very important reference for vacuum system design and operation for future fusion devices.

EAST

An atomic beam of titanium for ultracold atom experiments

Here we generate an atomic beam of titanium (Ti) using a “Ti-ball” Ti-sublimation pump, which is a common getter pump used in ultrahigh vacuum systems. We show that the sublimated atomic beam can be optically pumped into the metastable 3d 3 ( 4 F)4s a 5 F 5 state, which is the lower energy level in a cycling optical transition that can be used for laser cooling. We measure the atomic density and transverse and longitudinal velocity distributions of the beam through laser fluorescence spectroscopy. We find a metastable atomic flux density of 4.3(2) × 10 9 s -1 cm -2 with a mean forward velocity of 773(8) m/s at 2.55 cm directly downstream of the center of the Ti-ball. Owing to the details of optical pumping, the beam is highly collimated along the transverse axis parallel to the optical pumping beam and the flux density falls off as 1/r. We discuss how this source can be used to load atoms into a magneto-optical trap.