Line spectrum and ion temperature measurements from tungsten ions at low ionization stages in large helical device based on vacuum ultraviolet spectroscopy in wavelength range of 500–2200 Å

Vacuum ultraviolet spectra of emissions released from tungsten ions at lower ionization stages were measured in the Large Helical Device (LHD) in the wavelength range of 500–2200 Å using a 3 m normal incidence spectrometer. Tungsten ions were distributed in the LHD plasma by injecting a pellet consisting of a small piece of tungsten metal and polyethylene tube. Many lines having different wavelengths from intrinsic impurity ions were observed just after the tungsten pellet injection. Doppler broadening of a tungsten candidate line was successfully measured and the ion temperature was obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In situ , in vivo , and in operando imaging and spectroscopy of liquids using microfluidics in vacuum

This review offers a succinct overview of the development of a vacuum-compatible microfluidic reactor system for analysis at the liquid vacuum interface (SALVI), and its diverse applications in in situ, in vivo, and in operando imaging of liquid surfaces as well as the air-liquid (a-l), liquid-liquid (l-l), and solid-liquid (s-l) interfaces in the past decade. SALVI is one of the first microfluidics-based reactors that has enabled direct analysis of volatile liquids in vacuum surface tools such as scanning electron microscopy (SEM) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). Its integration into ambient and vacuum spectroscopy and microscopy is illustrated. Several applications are highlighted including (1) imaging nanoparticles in liquid using in situ SEM; (2) mapping the evolving l-l interface using in situ x-ray absorption spectroscopy and ToF-SIMS; (3) following complex a-l interfacial oxidation reaction products using in situ ToF-SIMS; (4) capturing biological interfaces of cells and microbes via in vivo multimodal and correlative imaging; and (5) monitoring the dynamic solid electrode and liquid electrolyte interface using in operando molecular imaging. Finally, outlook and recommendations are presented. Besides showing the holistic information volume obtained by real-time multiplexed imaging, this review intends to convey the importance of tool development in revolutionizing surface and interface analysis using vacuum platforms previously limited to solid surfaces. Microfluidics is manifested to be not limited to ambient conditions in many examples in this review. Moreover, fundamental interfacial phenomena underpinning mass and charge transfer can now be pursued in real time via innovated chemical imaging and spectroscopy.

42 ENGINEERING↗

Quantitation of olefins in sustainable aviation fuel intermediates using principal component analysis coupled with vacuum ultraviolet spectroscopy

Olefins, a common intermediate from biomass conversion processes, are undesirable in jet fuel because of their poor thermal stability. This paper presents an approach for olefin quantitation using 2D gas chromatography coupled with vacuum ultraviolet spectroscopy. Principal component analysis was used to reduce the dimensionality of the spectroscopic data from a highly olefinic fuel intermediate. A principal component template was created that enabled olefin quantitation, which was compared to the existing GCxGC-VUV approach from the literature. The principal component method was able to identify and quantify trace amounts of cyclodienes, which were present at only 0.01 wt% in the fuel sample. The principal component approach also identifies species that fall outside of the GCxGC template. For instance, quantitation with the literature method resulted in an olefin concentration of 0.95 times that of the principal component method due to olefins falling outside of the expected GCxGC regions. The principal component results were compared with 13 C and 1 H NMR data, which confirmed that the fuel had a high concentration of olefins and alkanes with little aromatic content.

Kosir, Shane↗

Synthetic aromatic kerosene property prediction improvements with isomer specific characterization via GCxGC and vacuum ultraviolet spectroscopy

This research explores an advanced method of fuel composition determination and builds upon typical hydrocarbon group type analyses performed with two-dimensional gas chromatography (GCxGC). In this study, structural information of individual species within Virent’s Synthetic Aromatic Kerosene (SAK) is identified by vacuum ultraviolet (VUV) spectroscopy. By mass, 71.3% of the components elute within six peaks of the chromatogram, from which 12 unique species are identified through a novel deconvolution method. Overall, the identification of 93.6%m across 26 structural isomers is made by the methods described in this work. With 93.6%m ascribed to specific isomers, the precision of fuel property predictions improves dramatically. For example, the absolute error of the viscosity prediction is reduced by 90% because of this advancement in diagnostic capability, and its 95-percentile confidence interval (precision only) is reduced by 93%. Additionally, the properties of SAK, blended with hydro processed esters fatty acids (HEFA), are demonstrated to have blended properties consistent with conventional jet fuel.

10 SYNTHETIC FUELS↗

System for time-discretized vacuum ultraviolet spectroscopy of spark breakdown in air

A system for time-discretized spectroscopic measurements of the vacuum ultraviolet (VUV) emission from spark discharges in the 60-160 nm range has been developed for the study of early plasma-forming phenomena. The system induces a spark discharge in an environment close to atmospheric conditions created using a high speed puff value, but is otherwise kept at high vacuum to allow for the propagation of VUV light. Using a vertical slit placed 1.5 mm from the discharge the emission from a small cross section of the discharge is allowed to pass into the selection chamber consisting of a spherical grating, with 1200 grooves/mm, and an exit slit set to 100 μm. Following the exit slit is a photomultiplier tube with a sodium salicylate scintillator that is used for the time discretized measurement of the VUV signal with a temporal resolution limit of 10 ns. Results from discharges studied in dry air, Nitrogen, SF{sub 6}, and Argon indicate the emission of light with wavelengths shorter than 120 nm where the photon energy begins to approach the regime of direct photoionization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

REAL-TIME OPTICAL SPECTROSCOPY OF VACUUM ULTRAVIOLET IRRADIATED PYRENE:H{sub 2}O INTERSTELLAR ICE

This paper describes a near-UV/VIS study of a pyrene:H{sub 2}O interstellar ice analogue at 10 K using optical absorption spectroscopy. A new experimental approach makes it possible to irradiate the sample with vacuum ultraviolet (VUV) light (7-10.5 eV) while simultaneously recording spectra in the 240-1000 nm range with subsecond time resolution. Both spectroscopic and dynamic information on VUV processed ices are obtained in this way. This provides a powerful tool to follow, in situ and in real time, the photophysical and photochemical processes induced by VUV irradiation of a polycyclic aromatic hydrocarbon containing inter- and circumstellar ice analogue. Results on the VUV photolysis of a prototype sample-strongly diluted pyrene in H{sub 2}O ice-are presented. In addition to the pyrene cation (Py{sup +}), other products-hydroxypyrene (PyOH), possibly hydroxypyrene cation (PyOH{sup +}), and pyrene/pyrenolate anion (Py{sup -}/PyO{sup -})-are observed. It is found that the charge remains localized in the ice, also after the VUV irradiation is stopped. The astrochemical implications and observational constraints are discussed.

99 GENERAL AND MISCELLANEOUS↗

Ex situ elaborated proximity mesoscopic structures for ultrahigh vacuum scanning tunneling spectroscopy

We apply ultrahigh vacuum Scanning Tunneling Spectroscopy (STS) at ultra-low temperature to study proximity phenomena in metallic Cu in contact with superconducting Nb. In order to solve the problem of Cu-surface contamination, Cu(50 nm)/Nb(100 nm) structures are grown by respecting the inverted order of layers on SiO{sub 2}/Si substrate. Once transferred into vacuum, the samples are cleaved at the structure-substrate interface. As a result, a contamination-free Cu-surface is exposed in vacuum. It enables high-resolution STS of superconducting correlations induced by proximity from the underlying superconducting Nb layer. By applying magnetic field, we generate unusual proximity-induced superconducting vortices and map them with a high spatial and energy resolution. The suggested method opens a way to access local electronic properties of complex electronic mesoscopic devices by performing ex situ STS under ultrahigh vacuum.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Femtosecond spectroscopy with vacuum ultraviolet pulse pairs

We combine different wavelengths from an intense high-order harmonics source with variable delay at the focus of a split-mirror interferometer to conduct pump-probe experiments on gas-phase molecules. We report measurements of the time resolution (< 44fs) and spatial profiles (4 {micro}m x 12 {micro}m) at the focus of the apparatus. We demonstrate the utility of this two-color, high-order-harmonic technique by time resolving molecular hydrogen elimination from C{sub 2} H{sub 4} excited into its absorption band at 161nm.

08 HYDROGEN↗

Electronic excitation of furfural as probed by high-resolution vacuum ultraviolet spectroscopy, electron energy loss spectroscopy, and ab initio calculations

The electronic spectroscopy of isolated furfural (2-furaldehyde) in the gas phase has been investigated using high-resolution photoabsorption spectroscopy in the 3.5–10.8 eV energy-range, with absolute cross section measurements derived. Electron energy loss spectra are also measured over a range of kinematical conditions. Those energy loss spectra are used to derive differential cross sections and in turn generalised oscillator strengths. These experiments are supported by ab initio calculations in order to assign the excited states of the neutral molecule. The good agreement between the theoretical results and the measurements allows us to provide the first quantitative assignment of the electronic state spectroscopy of furfural over an extended energy range.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗